Installation of a MIDEA EVOX G3 electric furnace in Brossard, on Montreal’s South Shore: horizontal configuration in the attic

In Kahnawake, AirGreen installs a MIDEA EVOX G3 electric furnace with organized refrigerant lines and an accessible transparent condensate trap, for a central system suited to Quebec heating and air conditioning.

By AirGreen Climatisation & Chauffage Admin14 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
14 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a MIDEA EVOX G3 electric furnace in Brossard, on Montreal’s South Shore: horizontal configuration in the attic
Installation of a MIDEA EVOX G3 electric furnace in Brossard, on Montreal’s South Shore: horizontal configuration in the attic
The full story

The article, chapter by chapter

In Kahnawake, the visible details around the furnace tell as much about the installation as the machine itself

This installation of a MIDEA EVOX G3 electric furnace in Kahnawake, on Montreal's South Shore, offers an excellent view of what distinguishes a carefully planned central installation from a simple equipment replacement. In our jobsite photo, the new MIDEA unit occupies a relatively compact mechanical room, surrounded by the existing duct network. But it is especially the connections on the side of the unit that deserve attention: copper refrigerant lines, an insulated line, PVC drainage, a transparent trap with cleaning access, and line organization to preserve service access.

The MIDEA EVOX G3 belongs to the family of inverter ducted central systems from MIDEA. This design makes it possible to combine a central indoor unit with an outdoor heat pump to provide heating and cooling through the property's duct network.

In Quebec, the indoor unit is commonly called electric furnace. In a configuration with an EVOX G3 heat pump, it does much more than heat air with electric elements: it circulates air, contains the indoor heat exchanger, distributes the heat produced by the heat pump, and can accommodate auxiliary electric heating when the building's needs require it.

A vertical installation in a mechanical room where space matters

In this installation at Kahnawake, the MIDEA EVOX G3 is installed in a vertical position.

To the left of the unit, the existing duct network occupies practically all the available depth. To the right, a wall also limits the clearance. We therefore had to arrange the connections compactly while avoiding turning the side of the furnace into a difficult-to-maintain tangle of pipes.

This constraint looks simple in a photograph, but it influences several decisions:

  • the route of the refrigerant lines;
  • the location of the fittings;
  • the drainage slope;
  • access to the coil;
  • the opening of the panels;
  • the clearance for future repairs;
  • the connection to the existing sheet metal.

A good HVAC installation must not only work when it is first turned on. It must remain understandable and accessible years later.

An EVOX G3 design suited to replacements and existing spaces

MIDEA designed this generation with particular attention to renovation projects. Depending on capacity, the documentation presents indoor units in relatively narrow formats, with widths corresponding to several common residential furnace dimensions. It also indicates a multivoltage design for the applicable indoor units, notably 115 V and 208/230 V depending on the application.

This is particularly relevant in properties where the ductwork and mechanical-room dimensions were established well before the arrival of modern inverter heat pumps.

The EVOX G3 is also designed for several installation orientations. MIDEA specifically documents the upflow, downflow, right horizontal, left horizontal, and certain low-boy applications, while highlighting its modular design to facilitate work in basements, attics, and other difficult spaces.

In the installation shown here, the vertical configuration corresponded to the layout of the existing network.

Refrigerant lines: a particularly visible detail in this installation

The right side of the unit provides a very clear view of the refrigerant circuit.

We can distinguish an uninsulated copper pipe and a larger-diameter pipe protected by black insulation. This insulation helps limit unwanted heat exchange and condensation on the pipe when operating conditions require it.

The lines follow the wall and are then neatly grouped together. Fasteners hold the bundle together without placing the connections directly in front of the main components that will need to be accessible during future HVAC service.

This type of arrangement has several practical advantages:

  • lower risk of accidental damage to the lines;
  • simpler inspection;
  • more logical access to the connections;
  • better organization in a small mechanical room;
  • reduced obstructions in front of the unit panels.

Once an installation is complete, the owner probably will not look at these pipes every day. However, for a technician who has to diagnose the system several years later, their arrangement becomes very important.

Drainage with a transparent trap: one of the most interesting details in the photo

The drain connection is particularly visible in this Kahnawake installation.

A white PVC pipe exits the unit and then connects to a transparent U-shaped trap. Two accesses with red caps are present on either side of the trap. A small cleaning brush is also visible nearby.

This setup offers a practical advantage: the condensate path can be inspected much more easily than with a completely opaque trap.

When the system operates in cooling mode, humid air from the home passes over the cold indoor coil. Water then forms on the coil and must be continuously drained.

The trap plays an important role in this drainage system. Depending on the unit’s pressure configuration, it helps allow condensate to drain properly while preventing airflow inside the unit from disrupting the drain’s operation.

Why cleaning access points are important

A condensate drain is not a component that we can simply install and forget about for twenty years.

Over time, deposits can accumulate in the line. Under certain conditions, biofilm can form. An obstruction can then slow or block the flow.

The visible caps on this setup provide much more convenient access to the trap for:

  • inspect the inside;
  • flush the line;
  • remove a buildup;
  • perform preventive cleaning;
  • ensure that the flow remains unobstructed.

This small detail can prevent a minor drainage problem from turning into water around the furnace or an air-conditioning shutdown in the middle of summer.

Drainage is a full-fledged HVAC component

When a homeowner compares two central heat pump quotes, their attention generally goes to the brand, BTUs, SEER2, warranty, and price.

The drainage rarely receives the same attention.

However, a central air-conditioning system can produce a significant amount of condensate during the hot, humid days of July and August in Greater Montreal.

A good drainage system should notably be:

  • properly sized;
  • supported;
  • installed with the necessary slope;
  • accessible;
  • cleanable;
  • connected to a suitable drain;
  • tested during commissioning.

The transparent trap visible on our Kahnawake installation makes this part of the system specifically easier to inspect and maintain.

A central R-454B system

In this generation of EVOX G3, MIDEA uses R-454B refrigerant. The manufacturer specifies that it is an A2L-classified refrigerant and indicates a global warming potential, or GWP, of 466.

For an HVAC company, this change means working with practices and equipment appropriate for this refrigerant category.

On the job site, this notably concerns:

  • the preparation of the connections;
  • the methods used on the refrigeration circuit;
  • vacuuming;
  • leak-tightness checks;
  • commissioning;
  • future refrigerant service work.

The A2L pictogram found on this generation of equipment is therefore not simply a new label. It accompanies a new generation of systems and work procedures.

A heat pump designed for Quebec’s cold climate

A central installation in Kahnawake must be capable of doing much more than cooling the house in July.

The main advantage of an EVOX G3 system is its pairing with an Inverter heat pump designed for cold-weather heating.

MIDEA documentation states that the heat pump can operate continuously down to approximately -30 °C. It also indicates, under certain test conditions, a high heating capacity at -25 °C, with a COP of approximately 1.9; MIDEA specifies that some of these figures come from a test conducted on a three-ton system.

This allows the heat pump to remain an active heating source during much of the Quebec winter, rather than automatically relying on electric elements as soon as the temperature drops below freezing.

The exact performance, however, remains linked to the precise matching of the indoor and outdoor models.

Auxiliary electric heating complements the heat pump’s work

The EVOX G3 can accommodate different auxiliary electric heating configurations.

MIDEA documentation mentions kits rated for up to 25 kW and multistage operation to adapt the supplemental heat to demand.

This certainly does not mean that a Kahnawake installation should automatically receive 25 kW.

At AirGreen, the appropriate capacity must be determined based on several factors:

  1. the electrical panel capacity;
  2. conductor gauge;
  3. electrical protection;
  4. the building’s heating load;
  5. the heat pump’s low-temperature capacity;
  6. the selected control strategy.

A properly sized auxiliary heater provides useful reserve capacity when needed without unnecessarily turning the system into an oversized resistance appliance.

Airflow, efficiency, and eligibility for financial incentives: the checks that complete the job

The duct system must be able to accommodate the new furnace

A modern electric furnace may have an excellent blower, but it still depends on the ductwork it is connected to.

The EVOX G3 uses Computational Constant Airflow 2.0, which allows the motor to adapt its operation to changes in system resistance. The documentation shows applications of up to 1.2 in. of external static pressure.

The manufacturer also provides an adjustment range of up to 60 airflow levels, giving the installer more flexibility during configuration.

This compensation capability nevertheless remains an adjustment tool, not permission to ignore an improperly sized duct system.

If the return airflow is insufficient or a duct has a significant restriction, we must identify it and determine whether a correction is necessary.

Filtration can also affect static pressure

MIDEA provides filtration solutions in 1-, 2-, and 4-inch, including configurations compatible with a MERV 13 filter.

We must always consider filtration together with airflow.

A more restrictive filter can capture more particles, but it also imposes additional resistance on the blower. The right solution therefore depends on the filter’s surface area, thickness, system airflow, and return-air network.

The highest MERV rating is not automatically the best choice if the system was not designed for that restriction.

Several capacities are available in the EVOX G3 range

MIDEA’s technical documentation shows that the EVOX G3 family covers several capacities. These include combinations around 18,000, 24,000, 30,000, 36,000, 48,000 and 54,000 BTU/h, with efficiency ratings that change from one pairing to another.

The corresponding indoor models include, among others, references from the MAUSE series, paired with different outdoor units in the product range.

In the photograph from our Kahnawake project, the exact model number is not clear enough to assign a specific capacity to this unit with certainty. We therefore prefer not to make up a BTU figure based solely on the cabinet’s apparent dimensions.

To compare a quote correctly, we always recommend requesting:

  • the complete indoor model;
  • the complete outdoor model;
  • the rated capacity;
  • the pairing’s efficiency rating;
  • the applicable AHRI reference.

Efficiency ratings that can reach high levels depending on the pairing

MIDEA’s technical table indicates, for example:

  • 19 SEER2 for an 18,000 BTU/h configuration;
  • 18.6 SEER2 for a 24,000 BTU/h configuration;
  • 17.2 SEER2 and 10.8 HSPF2 for a 30,000 BTU/h configuration;
  • 17.7 SEER2 for a 36,000 BTU/h configuration;
  • 17.5 SEER2 for certain 48,000 and 54,000 BTU/h configurations.

COP values at -15 °C also vary according to the documented combinations.

That is why we avoid presenting a single “EVOX G3” value as if it applied to all capacities.

Conventional thermostat or communicating system

The EVOX G3 also offers several control options.

MIDEA indicates that the platform can operate with 485 communication in certain configurations or with a conventional 24 V thermostat, including various scenarios involving EVOX or third-party components.

This flexibility is useful during a replacement, particularly when the existing wiring between the mechanical room and the thermostat is difficult to modify.

Precise compatibility must nevertheless be verified with the selected thermostat model and the desired functions.

LogisVert: what we can actually confirm for an installation in 2026

For heat pumps installed since November 26, 2025, Hydro-Québec currently requires them to be ENERGY STAR certified to qualify for LogisVert financial assistance. For a central heat pump, Hydro-Québec also indicates a minimum capacity of 24,000 BTU/h and considers the complete system, including the indoor and outdoor units.

This means it would be incorrect to claim that any furnace bearing the name MIDEA EVOX G3 automatically qualifies for a subsidy.

Eligibility must be verified against:

  • the exact indoor/outdoor match;
  • the installation date;
  • the required certification;
  • the LogisVert list applicable at the time of the work;
  • the home’s criteria.

Hydro-Québec also specifies that eligible models and amounts may change, and its search tool uses the installation date to determine the applicable list and financial assistance.

What we take away from this AirGreen installation in Kahnawake

This installation is a good example of a central system project in which quality is found in very concrete details.

The MIDEA EVOX G3 electric furnace naturally occupies the center of the installation, but it is not the only thing we consider.

We also need a well-organized refrigerant circuit, properly insulated piping, accessible drainage, a trap that can be inspected and cleaned, a duct network capable of delivering the required airflow, and sufficiently clear access for future service work.

This is exactly the approach we apply at AirGreen in our central heat pumps and electric furnaces in Kahnawake, Montréal, Laval, Longueuil, on the South Shore and the North Shore.

A successful central system installation is not merely a new machine that starts when we turn the power back on. It is a coherent system in which the heat pump, furnace, refrigerant piping, drainage, controls, and ductwork have all been integrated with the same level of care.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

    1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
    2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
    3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
    4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
    5. The outdoor unitOn a level base, raised above the snow, with free space all around.
    6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
    7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
    8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
    9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: central heat pump, indoor module and ducts

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

    2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

    3. A shut-off switch near the outdoor unit isolates it safely for service.

    4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

    5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

    6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

    7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

    8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment