Project

Installation of a GREE FreeMatch R32 2-head heat pump in Ormstown

GREE FreeMatch R32 2-head heat pump installed in Ormstown: refrigerant lines passing directly through the wall behind the unit, the head positioned near a window to counter the cold draft, with clearances maintained under the sloped ceiling. 24,000 BTU/h, SEER2 21.

By AirGreen Climatisation & Chauffage Admin11 min read
Installation of a GREE FreeMatch R32 2-head heat pump in Ormstown
Installation of a GREE FreeMatch R32 2-head heat pump in Ormstown
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The chosen wall determines everything else

A homeowner comparing heat pump quotes looks at the brand, capacity, and price. They almost never think about the one decision that will determine their daily comfort for fifteen years: which wall the indoor head will be mounted on.

Yet this is where everything is decided. The unit's performance, the installation's discretion, the piping length, drain reliability, and thermostat accuracy—all stem from this choice.

Here is how we did it on this project in Ormstown, in Haut-Saint-Laurent, where we installed a GREE FreeMatch R32 two-head configuration system.

The best possible scenario: exit directly behind the unit

Look at a wall-mounted heat pump installation in your area. In most cases, you will see a white plastic line set cover running along the wall, descending toward the floor, or crossing the room to a corner.

On this project, there isn't one. The refrigerant lines, interconnection cable, and condensate drain pass through the wall directly behind the cabinet, and emerge outside just a few centimeters from their starting point.

Why this is the ideal scenario
  • Nothing is visible indoors. The unit appears to be mounted on a bare wall.
  • The piping length is minimal, so pressure losses are minimal as well.
  • The number of bends is reduced to the strict minimum. Each bend adds resistance to the refrigeration circuit and creates a risk of crushing the tubing.
  • The condensate drain has a clear, short slope, eliminating the main cause of service calls for wall-mounted units.
  • A single hole, clean, sealed, and sloping outward.
What is needed to achieve it

This result is only possible if three conditions are met:

  1. The chosen wall is an exterior wall.
  2. The outdoor unit can be positioned on the correct side of this wall, in the immediate vicinity.
  3. The wall structure allows drilling at the desired height, without conflicting with a load-bearing element or a concealed utility.

These three conditions cannot be verified from a parking lot. They are verified during a technical visit, both indoors and outdoors, with a floor plan of the house in mind.

That is why a quote given over the phone is fiction. The locations of the head and the outdoor unit are linked; deciding them separately results in a six-meter cable duct.

The window: the best and most delicate location

On this job, the head is installed immediately beside a window. This choice deserves an explanation because it combines a real advantage with a trap.

The advantage: treating the problem at its source

In almost every home, the window is the room's thermal weak point.

In winter, the glass surface is colder than the walls. The air flowing along it cools, becomes denser, and descends along the wall to the floor. This is called a descending cold draft—the sensation of a “draft” that people often attribute to a poorly sealed window even when it is perfectly airtight.

In summer, the same window lets in solar radiation, which heats the floor, furniture, and surrounding air.

A head placed near the window addresses both of these phenomena where they originate, rather than waiting for the discomfort to spread throughout the room.

The trap: the temperature sensor

Here is the downside, and it is rarely explained.

The temperature sensor in a wall-mounted head is located inside the unit's housing. It measures the air drawn in through the intake at the top of the housing.

A unit placed near a window therefore measures the air in the most disturbed area of the room:

  • In summer, if the sun shines directly on the unit, the sensor reads a higher temperature than the actual temperature. The unit overcools the room.
  • In winter, cold air descending from the window can cause the sensor to read a lower temperature than the rest of the room. The unit overheats.
How we compensate

Three methods, in this order:

  1. Never place the unit in the path of direct sunlight. Moving it a few dozen centimeters, or choosing the side of the window, is generally enough.
  2. Use automatic louver sweeping rather than a fixed direction to even out the room temperature—and therefore what the sensor measures.
  3. Adjust the actual setpoint during commissioning, based on a few days of observation. If the unit displays 21 °C and the room is comfortable, the number does not matter much; comfort is what counts.

This explanation is part of our commissioning process. A customer who understands why their unit displays 21 °C while their thermometer reads 19.5 °C does not call us about a nonexistent fault.

The curtain, blind, and shelf: three discreet enemies

This is the consequence of installing the unit near a window, and it is something homeowners discover too late.

A wall-mounted unit draws air in from the top and discharges it from the bottom. Anything that obstructs either of these areas reduces performance.

The most common obstacles:

  • A long curtain or lowered blind that touches the side or underside of the unit. The discharged air is deflected, the curtain moves, and part of the airflow rises directly back toward the intake.
  • A curtain rod installed afterward, at the same height as the housing.
  • A shelf, frame, or tall wardrobe added nearby later.

We take existing window treatments into account when determining the position. And we warn the customer: if you change your curtains, make sure they do not touch the unit.

It is a trivial detail. Nevertheless, it explains some of the calls we receive two or three years after a perfectly executed installation: “my heat pump is less efficient than before.”

The sloped ceiling: working with the available height

Part of the room has a ceiling with a sloping line, a common configuration in village houses with converted attics or irregular spaces.

This imposes a simple but absolute requirement: the minimum clearance above the housing must be respected, regardless of the ceiling geometry.

The unit draws air in from the top. A housing installed too high beneath a slope restricts its intake, reducing airflow and impairing the discharge-air temperature. The result is a unit that seems to be working but fails to deliver.

In a room with a sloped ceiling, this sometimes means lowering the unit a few centimeters compared with what might seem most harmonious. We position it according to the technical constraint, then adjust the aesthetics—never the other way around.

Conversely, a sloped ceiling offers an advantage: it naturally channels airflow along the slope, improving reach in elongated rooms.

The five places where we never install an indoor unit

Summary of what the technical visit rules out immediately:

  1. Directly above a bed or reading chair. Continuous airflow over a stationary person becomes unbearable, and the occupant eventually turns the unit off.
  2. Facing an exterior door or in a vestibule. The unit continuously treats outdoor air and reads a distorted temperature.
  3. In a dead corner, behind a partition, or facing a nearby obstacle. Air distribution is restricted, leaving part of the room untreated.
  4. Above a heat source—fireplace, television, or nearby recessed lighting. The sensor reads a temperature unrelated to the room.
  5. On a wall where the drain would have to run upward. Water does not flow uphill. Without a condensate pump, it overflows through the front of the housing.

The installed equipment

The selected outdoor unit is the GREE FreeMatch R32, model GWHD(24)ND6MO, powering two indoor units.

  • Rated capacity of 7,030 W (24,000 BTU/h), for both heating and cooling.
  • Modulation range from 7,500 to 31,400 BTU/h, G10 inverter compressor.
  • Certified heating from -30 °C to 24 °C; cooling up to 48 °C.
  • SEER2 21 / HSPF2 10 / EER2 12, ENERGY STAR certified.
  • R32 refrigerant (A2L), 1,700 g precharged, integrated leak detection sensor.
  • 30 m precharged length, maximum 60 m, maximum elevation difference 15 m.
  • Indoor units powered by the outdoor unit: a single dedicated circuit for the entire system.
  • 19.5 A MCA, maximum 25 A protection at 208/230 V.
  • Intelligent defrosting, self-diagnostics, automatic voltage adjustment.
  • Standard 10-year warranty.
Why modulation changes how you feel near a window

Comfort near a glass surface depends less on the available capacity than on the continuity of the treatment.

An on-off unit heats strongly, stops, and then allows the descending cold draft to re-establish itself along the window until the next start-up. The occupant sitting near the window feels this alternation.

An inverter compressor that modulates between 7,500 and 31,400 BTU/h maintains continuous airflow at low speed. The descending cold draft is countered continuously rather than intermittently. This is exactly the kind of difference you do not see on a technical data sheet but feel every winter evening.

The A2L constraint

R32 is classified as mildly flammable and requires a minimum room volume for each indoor head, calculated according to the system charge. We perform this calculation during the design stage, before proposing a configuration—in Ormstown as well as Huntingdon, Saint-Chrysostome, Châteauguay, Longueuil, Montréal, Laval, on the North Shore and the South Shore.

Financial assistance

GREE documentation indicates that these systems are eligible for local rebates, and ENERGY STAR certification is among the common criteria for Quebec energy-efficiency programs.

Eligibility depends on your situation: replaced heating source, type of building, and program in effect when the work is carried out. We validate the file before installation and provide the required documentation rather than announcing an amount that might not apply to your case.

Maintenance

  • Filters cleaned every 4 to 6 weeks under heavy use. A clogged filter reduces airflow, causes the evaporator to freeze, and overloads the compressor.
  • Clear area around the unit, including curtains and blinds.
  • Outdoor unit free of snow and vegetation.
  • Professional deep cleaning of the indoor heat exchanger every two to three years: dust stuck to the blower wheel is invisible from the filter.
  • Annual HVAC maintenance: pressures, tightening, drain, condition of connections.

Are you considering a multi-zone wall-mounted heat pump in Ormstown or the Haut-Saint-Laurent area, and wondering where the unit could be installed in your home? Contact us. The technical visit starts with that question—because it determines everything else.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment