SHARP BU dual-zone
Outdoor AE-X3M24BU · heads AY-XPC9BU + AY-XPC18BU
AHRI 213927543 · NEEP 507394
The SHARP BU job in Lorraine (9,000 and 18,000 BTU heads) and the ZEPHYR Hi MULTI Xtreme R-454B: one room at a time, NEEP, extreme cold, cost.

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp BU 24 0002 Zones (Dual Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
| Sharp BU 24 0003 Zones (Triple Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
In Lorraine, AirGreen installed a SHARP BU heat pump: a 24,000 BTU/h outdoor unit, a 9,000 BTU head in a small room and an 18,000 BTU head in the living room. Here is that job, then the ZEPHYR Hi MULTI Xtreme R-454B, sold by AirGreen in the same class, certified value by certified value. One question guides the page: what happens when only one of the two rooms calls for air, in summer as in winter? No ranking.

Outdoor AE-X3M24BU · heads AY-XPC9BU + AY-XPC18BU
AHRI 213927543 · NEEP 507394

Outdoor ZE-527M325 · heads ZE09CB25I, ZE12CB25I, ZE18CB25I
AHRI 216684164 · NEEP 424265
Both AHRI certificates cover a multi-zone system with non-ducted indoor units; certified values belong to the whole system. AirGreen sells the ZEPHYR in its 24,000 BTU/h class; its NEEP certificate gives it 27,000 BTU/h rated, in cooling as in heating at 8.3 °C. The page follows the certificate.
AirGreen estimate for a one-storey Lorraine house whose heat loss reaches 24,000 BTU/h, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated the same way, with the same method as on all our comparison pages, at the common size of 24,000 BTU/h; only their certified efficiencies change. Since both calculation houses are identical, the difference comes from HSPF2 Region V (9.0 and 7.7) in winter and from SEER2 (24.0 and 23.0) in summer. Degree-days are Montréal’s, the nearest reference station published by Natural Resources Canada. Electric baseboards serve as the point of reference.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
A closed office on a summer afternoon: only the 9,000 head calls for air, the living room is at the right temperature. The outdoor unit, though, is built for 24,000 BTU/h and more. The NEEP certificate publishes, at each test temperature, the smallest measured output of each system. Pick the season and the room that calls: the page sets the head’s rated output against each outdoor unit’s certified range.
Schematic plan of a one-storey house, not to scale. Heads on the job: AY-XPC9BU in the small room, AY-XPC18BU in the living room.
Bar: range certified by NEEP at this temperature, from minimum to maximum; yellow mark: rated value. Dashed line: rated output of the heads calling, per each manufacturer (SHARP: 2025 brochure, p. 13; ZEPHYR: CB25 brochure BRO_2606, single-zone version). It is a reference point, not the room’s actual load.
What the numbers show. At 35 °C, NEEP certifies a minimum of 5,500 BTU/h for the SHARP BU and 9,500 for the ZEPHYR. At 8.3 °C, in heating, the minimums are 8,800 and 12,870 BTU/h. Higher up the range, the ZEPHYR certifies more: 31,300 BTU/h at most at 35 °C and 38,167 at 8.3 °C, against 27,000 and 30,000 for the SHARP.
What the page does not say. These minimums are measured on the complete certified system. What each unit does when a single head calls and demand drops below that minimum is not described in the documents consulted. At −15 °C, the ZEPHYR’s certified minimum (3,500 BTU/h) is far lower than at 8.3 °C and at −25 °C: the page shows the value as published.
At −15 °C, both certificates give a value at the same temperature: 21,200 BTU/h for the SHARP, 27,000 for the ZEPHYR. Further down, NEEP publishes each system’s coldest point: −27.2 °C for the SHARP, −25 °C for the ZEPHYR. At −25 °C, both have a value, but not from the same source: 19,177 BTU/h certified for the ZEPHYR, 15,700 printed in the SHARP brochure, without test conditions.
Only what the documents consulted name: the SHARP 2025 brochure, the ZEPHYR CB25 brochure (BRO_2606) for the heads and the NEEP records. No ZEPHYR document specific to the ZE-527M325 outdoor unit was found.
SHARP 2 or 3 heads, per the AE-X3M24BU combination table.
ZEPHYR Not stated in a ZEPHYR document consulted; AirGreen sells the ZE-527M325 in two and three zones.
SHARP Not stated in the brochure; the NEEP field is blank.
ZEPHYR 300 W, controlled by outdoor temperature and defrost (NEEP).
SHARP Heating range advertised down to −27 °C.
ZEPHYR Outdoor unit range not found; coldest certified point at −25 °C.
SHARP Wi-Fi built into all units, per the SHARP 2025 brochure.
ZEPHYR Not mentioned in the CB25 brochure; AirGreen’s product page lists it as an option.
SHARP Not recorded on the brochure page consulted.
ZEPHYR Night, silent, “ifeel”, Turbo, 8 °C heating, five fan speeds (CB25 brochure).
SHARP Yes, after a power outage (brochure).
ZEPHYR Not recorded in the CB25 brochure.
“Not recorded” or “not found” means the document consulted does not mention it, not that the feature is absent.
How to read these numbers. The lower the number, the quieter the head; each dot is a published fan speed. SHARP publishes the lowest and highest speed; ZEPHYR publishes five speeds, from Silent to Ultra-high.
Why this is not a ranking. Method not stated in either brochure; the ZEPHYR values come from the single-zone version of the heads. Outside, SHARP publishes 49 dB(A) in cooling and 50 in heating; no ZEPHYR document consulted gives the sound of the ZE-527M325.
Values published by each manufacturer, by its own method: they read side by side, without ranking.
| Item | SHARP BU | ZEPHYR Hi MULTI Xtreme |
|---|---|---|
| 9,000 head dimensions | 34 39/64 × 11 3/8 × 9 1/64 in (W × H × D)SHARP 2025 brochure, AY-XPC9BU | 33 7/16 × 11 9/16 × 8 1/16 in (W × H × D)CB25 brochure (BRO_2606), ZE-09CB25 |
| 18,000 head dimensions | 41 27/64 × 12 7/16 × 9 51/64 inSHARP 2025 brochure, AY-XPC18BU | 42 1/16 × 12 5/8 × 9 1/16 inCB25 brochure (BRO_2606), ZE-18CB25 |
| Head airflow, min. to max. | 9BU: 145 to 438 cfm; 18BU: 290 to 752 cfmSHARP 2025 brochure | 9k: 253 to 383 cfm; 18k: 383 to 647 cfmCB25 brochure, single-zone version |
| Maximum piping length | 230 ft (70 m) in totalSHARP 2025 brochure; length per head not stated | Not found in a ZEPHYR document for the ZE-527M325 |
| Maximum height difference | 33 ft (10 m)SHARP 2025 brochure | Not found for the ZE-527M325 |
| Liquid – gas diameters | 1/4 – 3/8 in, ports A, B, CSHARP 2025 brochure | Heads in single zone: 1/4 – 3/8 in (9k), 1/4 – 1/2 in (18k)CB25 brochure; ZE-527M325 ports not found |
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 115 lbSHARP 2025 brochure | Not found in a ZEPHYR document |
| Electrical protection | 208-230 V; max. fuse 25 ASHARP 2025 brochure | Not found for the ZE-527M325 |
| Refrigerant | R-32 · GWP 675 (IPCC AR4) · class A2L | R-454B · GWP 466 (IPCC AR4) · class A2L |
For the ZEPHYR, the outdoor unit’s piping limits, height difference and electrical protection are confirmed in the ZE-527M325 installation manual before the work. In a one-storey house like the one in Lorraine, height difference matters little; the length to the furthest head matters more.
Both are two-head multi-zone systems sold by AirGreen in the 24,000 BTU/h class, certified with non-ducted wall units, ENERGY STAR and cold climate per NEEP. The SHARP BU runs on R-32, the ZEPHYR on R-454B. The page makes no ranking.
Yes. NEEP publishes 27,000 BTU/h rated for the ZE-527M325 system (AHRI 216684164), in cooling at 35 °C as in heating at 8.3 °C. The SHARP BU is certified at 24,000 BTU/h in cooling and 26,000 in heating at 8.3 °C. The page compares the certified values as they are.
The documents consulted do not say. They give the complete system’s smallest certified output at each temperature, which the “One room at a time” section sets against the head calling. Heads and their size are chosen room by room during the estimate visit.
At −15 °C, NEEP certifies 21,200 BTU/h for the SHARP BU and 27,000 BTU/h for the ZEPHYR. Further down, the certified points are at different temperatures (−27.2 °C and −25 °C): the Extreme cold section shows them with their source.
Eligibility is checked with the AHRI number in the program’s current official list (for example Hydro-Québec’s LogisVert), which can change. The numbers are 213927543 for the SHARP BU and 216684164 for the ZEPHYR. This page announces no amount.
The page does not compare warranties. Each manufacturer’s warranty documents come with the quote.
| Value (NEEP, read Nov. 17, 2026) | SHARP BU | ZEPHYR Hi MULTI Xtreme |
|---|---|---|
| Seasonal efficiency | ||
| SEER2 | 24,0 | 23,0 |
| EER2 | 14,0 | 12,85 |
| HSPF2 Region IV | 11,5 | 10,0 |
| HSPF2 Region V | 9,0 | 7,7 |
| Cooling, min. / rated / max. | ||
| Capacity min. / rated / max. at 35 °C | 5 500 / 24 000 / 27 000 BTU/h | 9 500 / 27 000 / 31 300 BTU/h |
| COP min. / rated / max. at 35 °C | 5,37 / 4,11 / 3,84 | 3,76 / 3,77 / 3,16 |
| Capacity min. / max. at 27.8 °C | 6 500 / 29 000 BTU/h | 9 800 / 31 400 BTU/h |
| Heating, min. / rated / max. | ||
| Capacity min. / rated / max. at 8.3 °C | 8 800 / 26 000 / 30 000 BTU/h | 12 870 / 27 000 / 38 167 BTU/h |
| COP min. / rated / max. at 8.3 °C | 4,69 / 4,35 / 4,19 | 2,79 / 3,60 / 2,80 |
| Capacity min. / rated / max. at −8.3 °C | 7 600 / 25 000 / 25 000 BTU/h | 12 130 / 17 600 / 29 100 BTU/h |
| COP min. / rated / max. at −8.3 °C | 2,93 / 2,53 / 2,53 | 2,69 / 2,70 / 2,40 |
| Capacity min. / rated / max. at −15 °C | 8 400 / 21 200 / 21 200 BTU/h | 3 500 / 27 000 / 27 000 BTU/h |
| COP min. / rated / max. at −15 °C | 2,46 / 2,30 / 2,30 | 1,86 / 1,82 / 1,80 |
| Coldest published point (different temperatures) | ||
| Test temperature | −27,2 °C (−17 °F) | −25 °C (−13 °F) |
| Capacity min. / max. | 5 100 / 14 600 BTU/h | 10 500 / 19 177 BTU/h |
| COP at min. / at max. | 1,74 / 1,84 | 1,40 / 1,40 |
| Certification | ||
| ENERGY STAR | Yes | Yes |
| ENERGY STAR cold climate | Yes | Yes |
| Base pan heater (NEEP) | Field blank | 300 W |
| AHRI certificate · NEEP record | 213927543 · 507394 | 216684164 · 424265 |
| Refrigerant | R-32 | R-454B |
“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation. Capacities are not marked: the ZEPHYR is certified at a larger rated size (27,000 against 24,000 BTU/h in cooling).
An estimate visit lets you choose the size of each head room by room, from the office to the living room.
Data verified on November 17, 2026. Certified values come from the AHRI certificates published by NEEP; the others come from the manufacturers’ documents, named under each value. When two sources differ, the page follows the certificate.
The SHARP and ZEPHYR marks belong to their owners. Logos and images identify the products. AirGreen is a dealer; this article is not produced, sponsored or approved by the manufacturers. Photos: AirGreen and manufacturers, for identification.
Does a value look wrong? Write to us at sales@airgreen.ca.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Six simple habits that keep the unit going. Your list stays on this device.
Three habits per season for this unit. They take a few minutes and prevent many calls.
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).