Project

Installation of a Fujitsu AIRSTAGE Orion XLTH wall-mounted heat pump in Ahuntsic-Cartierville, Montreal

Fujitsu Orion XLTH wall-mounted heat pump installed in Ahuntsic-Cartierville: compact installation near the ceiling, neat finish, Inverter technology, R-32, and heating for cold climates down to -26 °C.

By AirGreen Climatisation & Chauffage Admin16 min read
Installation of a Fujitsu AIRSTAGE Orion XLTH wall-mounted heat pump in Ahuntsic-Cartierville, Montreal
Installation of a Fujitsu AIRSTAGE Orion XLTH wall-mounted heat pump in Ahuntsic-Cartierville, Montreal
–chapters in this story
16 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

A high wall-mounted installation where positioning, finish, and airflow matter just as much as the equipment itself

In Ahuntsic-Cartierville, Montreal, this installation of a Fujitsu AIRSTAGE Orion XLTH wall-mounted heat pump presents a situation we regularly encounter in Montreal homes: the space available for the indoor unit is limited, the system must remain discreet, and the piping route must be integrated neatly without turning the wall into an assembly of visible pipes and fittings.

The photograph taken after our work clearly shows the result. The Fujitsu unit is installed very high on the wall, near the ceiling. On the right, a white line-set cover follows the unit’s profile and neatly incorporates the connections into a clean finish. The lower flap is open, revealing the air outlet across the full width of the unit—an important detail that clearly illustrates the importance of positioning: a wall-mounted heat pump needs sufficient space in front of it to distribute air effectively throughout the room.

In a house or apartment in Ahuntsic-Cartierville, this type of decision is never simply a matter of choosing “the wall that is still available.” We must consider the ceiling, the structure, the piping route, condensate drainage, airflow direction, accessibility for filter cleaning, and the relationship between the indoor unit and the outdoor condenser.

A constraint visible in the photo: working with limited clearance above

One of the most interesting aspects of this installation is how close the unit is to the ceiling.

In this type of configuration, a few centimetres matter. We must check that the unit can draw in enough air, that its front panel remains accessible, and that HVAC maintenance can be performed without having to dismantle part of the wall or ceiling.

We therefore avoid determining the height by eye alone. Before installation, we assess in particular:

  • the clearances required by the manufacturer;
  • the position of the wall bracket;
  • the possible presence of studs, wiring, or plumbing;
  • the actual ceiling height;
  • the clearance required to open the front panel;
  • the drain route;
  • the direction of the airflow toward the occupied area;
  • the routing of the copper lines and wiring to the outside.

The visible result of this installation is particularly compact: the unit uses the upper portion of the wall and leaves almost the entire lower surface available.

A pipe finish that is an integral part of the installation

On the right side of the indoor unit, the white line-hide runs horizontally along the wall. This detail is worth highlighting because the visual quality of a wall-mounted heat pump installation in Montreal often depends as much on the finish of the lines as on the unit itself.

A ductless installation nevertheless requires several connections between the indoor and outdoor units:

  • refrigerant copper lines;
  • interconnection cable;
  • power supply depending on the configuration;
  • condensate drainage.

When these components must run indoors before passing through the wall, we look for the most logical and discreet route possible. In a residential neighborhood such as Ahuntsic-Cartierville, where we work in houses as well as duplexes, triplexes, and older buildings, the walls do not always allow a direct passage behind the unit.

The line-hide then becomes an important finishing element rather than merely an accessory.

Fujitsu AIRSTAGE Orion XLTH: a range designed for cold climates

The installed unit belongs to the Fujitsu AIRSTAGE Orion XLTH family, identified in the manufacturer’s documentation as a single-zone H series of Orion CTEB wall-mounted systems. This range includes several capacities and is designed to provide heating down to -26 °C (-15 °F).

This minimum temperature is particularly relevant in Montreal. A heat pump used in Quebec must be evaluated not only on its ability to provide cooling in July, but also on how it performs when outdoor temperatures drop sharply in January or February.

Fujitsu’s stated heating operating range extends from -26 °C to 24 °C, while the air-conditioning range runs from -10 °C to 50 °C for all models presented in this series.

Multiple capacities for very different needs

The photograph does not allow us to reliably confirm the exact BTU capacity of the installed unit. We therefore prefer not to arbitrarily assign a specific model to this installation.

The official Fujitsu documentation presents the following variants:

Combination Nominal cooling Nominal heating
ASUH09KZAS / AOUH09KZAH1 9,000 BTU/h 12,000 BTU/h
ASUH12KZAS / AOUH12KZAH1 12,000 BTU/h 16,000 BTU/h
ASUH15KZAS / AOUH15KZAH1 14,500 BTU/h 18,000 BTU/h
ASUH18KZAS / AOUH18KZAH1 18,000 BTU/h 21,600 BTU/h
ASUH24KZAS / AOUH24KZAH1 22,000 BTU/h 25,200 BTU/h

These values come from the Fujitsu specifications for the Orion XLTH series.

At AirGreen, we emphasize the distinction between nominal cooling capacity and nominal heating capacity. A heat pump sold as “12,000 BTU,” for example, may offer a nominal heating capacity different from its cooling capacity.

This is another reason to avoid sizing a system based solely on a simple floor-area rule.

Efficiency, quiet operation, and winter performance: what the specifications really tell us

High seasonal efficiency depending on the selected capacity

The series’ efficiency ratings are particularly interesting.

Depending on the model, Fujitsu indicates a TRÈS2/SEER2 ranging from 24.0 to 33.1:

  • 09K : 33,1;
  • 12K : 30,5;
  • 15K : 27,5;
  • 18K : 25,5;
  • 24K : 24,0.

The CPSC2 Region V, which corresponds to the seasonal heating efficiency used in the documentation, ranges from 9.4 to 10.7.

These figures make it possible to compare heat pumps more meaningfully than by looking at BTU ratings alone. Two units capable of producing a similar amount of heat may have different seasonal energy consumption.

Significant heating capacity even as temperatures drop

The Fujitsu specifications also provide information that we find particularly useful when analyzing a cold-climate heat pump: the percentage of maximum capacity still available at different outdoor temperatures.

At -21 °C, the listed values range from 95% to 154% of the reference nominal capacity, depending on the model. At -26 °C, Fujitsu indicates 80% to 127%, depending on the capacity.

This demonstrates why two heat pumps, both with a published minimum temperature of -26 °C, are not necessarily equivalent. The important question is not only, “Does the machine still operate?” You must also consider how much capacity it can provide at that temperature.

For a residence in Ahuntsic-Cartierville, this can influence the choice of capacity and the building’s overall heating strategy.

Inverter technology: much more than simple on-off operation

The Orion XLTH series uses an Inverter compressor.

This technology allows the unit to adjust its output to the actual thermal demand instead of operating only at full capacity and then shutting off.

The 12K model, for example, can modulate in cooling between 3,100 and 16,000 BTU/h, while its heating range extends from 3,500 to 23,600 BTU/h. The 15K can reach up to 19,000 BTU/h in cooling and 25,000 BTU/h in heating.

This modulation range is particularly useful during the milder temperatures of spring and fall, when the building needs only a fraction of the unit’s maximum capacity.

As low as 23 dB(A) indoors

The location visible in the photo also leads us to discuss noise.

A wall-mounted unit installed in an occupied space must be quiet, especially when it is located near a bedroom, living room, or office.

Fujitsu indicates an indoor sound level as low as 23 dB(A) in quiet mode for the 9K and 12K models. The 15K reaches 26 dB(A), while the 18K and 24K models reach 30 dB(A) in quiet mode.

The unit offers six fan speeds, in addition to automatic mode. Airflow can therefore be adjusted as needed rather than remaining constantly at the maximum level.

A relatively compact indoor unit

The 9K, 12K, and 15K models use an indoor unit measuring just 280 mm high, 980 mm wide, and 240 mm deep. The 18K and 24K versions measure 340 mm high, 1,150 mm wide, and 280 mm deep.

These dimensions partly explain why this family of appliances is interesting when we have to work with a relatively limited wall section.

In the installation photographed in Ahuntsic-Cartierville, the unit’s low height allows it to be installed very close to the ceiling while retaining a wall-mounted appliance with discreet proportions.

R-32: the refrigerant used by this Orion XLTH generation

The series uses R-32 refrigerant.

In its brochure, Fujitsu compares a global warming potential of 675 for R-32 with 2,088 for R-410A, corresponding to an announced GWP reduction of 68 %. The manufacturer also specifies that R-32 systems require a smaller amount of refrigerant while maintaining the desired performance.

For our technicians, this also means that installation must be performed using procedures, tools, and practices suited to the refrigerant used by the unit.

ProCore coils and a design suited to extended use

Fujitsu documentation also mentions ProCore copper coils with high corrosion resistance on the indoor unit. It also indicates a base heater on the outdoor unit, designed for regions with extremely cold climates.

The base heater is particularly relevant during winter defrost cycles. When the outdoor unit extracts heat from the air in cold weather, frost can form on the heat exchanger. The system must periodically defrost it, producing water.

This is precisely why the outdoor unit’s placement must be properly planned: clearance beneath the unit, suitable support, space for drainage, and protection against excessive snow accumulation.

Piping diameters are not the same across the entire range

Another important technical detail appears in the Fujitsu table.

Refrigerant line sizes vary by capacity:

  • 9K and 12K: 1/4 in. liquid + 3/8 in. gas;
  • 15K: 1/4 in. liquid + 1/2 in. gas;
  • 18K and 24K: 3/8 in. liquid + 5/8 in. gas.

This information becomes especially important when a homeowner wants to replace an old heat pump while keeping the existing lines.

We never automatically assume that existing piping is compatible. We check its diameter, condition, length, routing, and the exact requirements of the new indoor-outdoor combination.

Piping lengths that offer true flexibility

The series also allows significant distances between the units.

The 9K and 12K models allow up to 82 feet of piping, the 15K up to 98 feet, while the 18K and 24K models can reach 164 feet. The maximum vertical difference can be up to 98 feet on the larger capacities.

This flexibility can be decisive in Montreal, where the indoor unit and condenser cannot always be placed directly on opposite sides of the same wall.

The electrical circuit must also match the capacity

All the models presented operate on a 208 to 230 V, 60 Hz, single-phase power supply.

However, the required circuit breaker varies: Fujitsu indicates 15 A for the 9K and 12K models and 20 A for the 15K, 18K, and 24K models.

During our installations in Ahuntsic-Cartierville, Laval, Longueuil, on the North Shore, or on the South Shore, we therefore verify the electrical supply before considering the project ready for installation.

The best unit on paper is not the right unit if the building cannot accommodate it properly without major modifications.

Integrated Wi-Fi and remote control

Fujitsu also indicates integrated Wi-Fi connectivity with remote monitoring through the AIRSTAGE mobile app. The series supports several control options and can also be integrated with certain BACnet and Modbus systems using compatible interfaces.

For a residential homeowner, the main benefit is the ability to manage the temperature without being directly in front of the unit.

In a more complex building, control options become useful for integrating the heat pump into a broader management strategy.

ENERGY STAR and subsidies: verify the exact combination before promising an amount

The technical sheet classifies the models in this series as ENERGY STAR, ENERGY STAR Cold Climate, and ENERGY STAR Most Efficient.

These classifications are relevant to homeowners looking for an efficient heat pump and wishing to verify their eligibility for financial assistance.

However, we avoid announcing a subsidy amount based solely on the name “Orion XLTH.” Programs may depend on the AHRI number, capacity, exact unit combination, and criteria in effect at the time of installation.

At AirGreen, the proper method is to verify the indoor model, outdoor model, and exact eligible reference before confirming the applicable financial assistance.

The mistakes this installation reminds us to avoid

A clean final installation like the one shown in the photo may give the impression that installing a wall-mounted heat pump is a simple operation. In reality, several mistakes can significantly reduce the quality of the result.

Installing the unit too close to an obstacle.

A shelf, ceiling, cabinet, or door can disrupt air intake or distribution. When space is tight, measurements must be precise.

Choosing the number of BTUs based solely on the area

Insulation, windows, solar exposure, the layout of the floors, and heat loss all change the actual requirement.

Neglecting the drain route

An indoor unit produces condensate in cooling mode. An improperly designed drain can lead to water, noise, or maintenance problems.

Reusing copper without checking its dimensions

As the Fujitsu specifications sheet shows, the piping changes between a 12K, a 15K, and an 18K.

Installing the outdoor condenser too low

In Montreal, snow and defrost water must be taken seriously. The unit must maintain its clearances even in the middle of winter.

Forgetting about future maintenance

The filters in the Orion XLTH range are washable. Users must therefore be able to access the indoor unit normally and open its front panel.

An AirGreen installation adapted to the realities of Ahuntsic-Cartierville

Ahuntsic-Cartierville features a mix of single-family homes, duplexes, triplexes, condos, and buildings where the space available for HVAC equipment varies greatly from one property to another.

This installation clearly illustrates our approach: we adapt the project to the building rather than trying to impose a standard configuration.

Here, the indoor unit occupies a very high area of the wall, the piping is integrated into a discreet cover, and the air outlet maintains a clear path into the room. This arrangement makes it possible to enjoy the comfort of a Fujitsu wall-mounted heat pump while limiting its visual impact in the living space.

We apply the same principles during our installations in Montreal, Laval, Longueuil, on the North Shore and the South Shore: correctly selecting the capacity, checking the structure, planning the refrigerant line route, protecting the drainage, validating the electrical system, and maintaining the access required for servicing.

A good HVAC installation is measured by more than whether the machine starts at the end of the work. It is also judged by the quality of air circulation, the cleanliness of the finishes, winter operation, noise level, accessibility, and the overall consistency of the system.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment