Project

Installation of a MIDEA 28 triple-zone heat pump in Mont-Saint-Hilaire, on Montreal’s South Shore

MIDEA 28 triple-zone heat pump installed in Mont-Saint-Hilaire: outdoor unit on wall brackets, three comfort zones, meticulous HVAC installation, MIDEA technical data, and key considerations for a durable system.

By AirGreen Climatisation & Chauffage Admin15 min read
Installation of a MIDEA 28 triple-zone heat pump in Mont-Saint-Hilaire, on Montreal’s South Shore
Installation of a MIDEA 28 triple-zone heat pump in Mont-Saint-Hilaire, on Montreal’s South Shore
–chapters in this story
15 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

A multi-zone installation in which positioning the outdoor unit was an integral part of the work

At Mont-Saint-Hilaire, this installation of a MIDEA 28 triple-zone heat pump shows an aspect of HVAC work that directly affects system durability: the location of the outdoor unit. In the final construction-site photo, the single-fan MIDEA unit is installed on two metal brackets secured to the foundation, between a large ground-floor window and a small basement window. The lines are grouped within a white finish that runs horizontally along the building, while access to the existing installations, including the outdoor faucet on the right, remains unobstructed.

This type of configuration seems simple once completed. However, before securing a multi-zone heat pump, we must check several constraints at the same time: the height above the ground, the presence of windows, the route of the refrigerant lines, service clearance, the proximity of other building elements, and the amount of unobstructed air available in front of and around the condenser.

In Mont-Saint-Hilaire, where a heat pump must contend not only with the hot periods of summer but also with snow, ice, and defrost cycles in winter, the outdoor installation deserves as much attention as the choice of indoor units.

A single outdoor unit for three separate zones

The principle behind the installed system is particularly interesting for a house with several spaces having different needs. One triple-zone heat pump uses a single outdoor condenser to power three indoor units.

MIDEA describes its multi-zone architecture as a system in which one outdoor unit is connected to several indoor units, each of which can be adjusted and programmed individually according to the desired temperature in its space.

In practical terms, such a configuration makes it possible to condition, for example, a living room and two bedrooms without having to install three independent outdoor units.

Page 2 of the MIDEA 28 brochure also highlights two advantages directly associated with this architecture: individual control of the indoor units and the reduction of the outdoor space required when several zones are grouped on a single condenser.

For a property in Mont-Saint-Hilaire, which can be a significant advantage when the side façade, yard, or space between two houses needs to remain as clear as possible.

The photo reveals an important detail: the heat pump is not placed on the ground

One of the most visible elements of this HVAC installation is the wall-mounted installation of the outdoor unit.

Here, we have a unit supported by two metal brackets anchored in the concrete portion of the foundation. It is therefore significantly elevated above the slabs in the exterior passage.

This method offers several benefits in our climate:

  • it keeps the unit higher than the immediate ground level;
  • it reduces exposure to certain snow accumulations;
  • it frees up the ground space beneath the condenser;
  • it facilitates inspection of the lower part of the unit;
  • it makes it possible to work around the constraints already present on the façade;
  • it avoids adding a ground-level slab in a relatively narrow passage.

The height cannot be chosen at random, however. On this property, a small basement window is located directly below the available area, while a much larger window occupies the upper part of the façade.

The condenser therefore had to be positioned between these two openings, without obstructing the basement window or encroaching on the one on the upper level.

This is precisely the kind of detail we assess when preparing a heat pump in Mont-Saint-Hilaire, Beloeil, Longueuil, or elsewhere on the South Shore.

A piping route designed to follow the building

The photo also shows a white finish running horizontally along the bottom of the exterior siding before reaching the MIDEA outdoor unit.

These protections group and protect the components required for the system to operate, including the refrigerant lines and the wiring associated with the installation.

With a single-zone heat pump, the route can sometimes be very short. With a triple-zone heat pump, the work becomes more complex because several indoor units communicate with the same outdoor unit.

This specifically requires coordinating:

  • the various refrigerant line sets;
  • the electrical and communication connections;
  • the routes coming from the three zones;
  • changes in direction;
  • the building entry points;
  • future access to the connections.

A quality exterior finish is therefore not merely aesthetic. It also protects the installations and helps maintain an organized layout that remains easy to understand during future HVAC maintenance or diagnosis.

MIDEA 28: a multi-zone architecture designed for multiple configurations

The MIDEA documentation provided with this installation shows that the range is not limited to a single combination.

The brochure specifically lists condensers capable of handling 1 to 3 zones, 1 to 4 zones, 1 to 5 zones, and up to 6 zones, depending on the selected capacity and model.

This is important information when a homeowner compares a triple-zone installation with another quote.

The term “triple-zone” indicates that three spaces will be served, but it does not by itself reveal:

  • the exact capacity of the condenser;
  • the capacity of each of the three indoor units;
  • the type of indoor unit;
  • the certified efficiency of the combination;
  • the AHRI number for the system.

Since the exact nameplate of the installed outdoor unit is not legible in the provided photo, we do not artificially assign it a model number or capacity that cannot be visually confirmed. The project is identified as a MIDEA 28 triple-zone, but the exact combination must always be verified against the invoice and the model numbers actually installed.

Why the combination of BTUs is more important than simply adding them

The MIDEA brochure contains several pages devoted to the combination rules for indoor units.

For a three-zone configuration, several capacities may be permitted depending on the outdoor unit selected. The documentation shows, for example, combinations such as 6 + 6 + 6, 6 + 6 + 9, 6 + 9 + 12, 9 + 9 + 9, 9 + 12 + 12 and other configurations depending on the condenser model.

These figures represent nominal thousands of BTUs per hour for each indoor unit.

But here is the technical point we always insist on explaining: adding the nominal capacity of the three indoor units does not guarantee that each one will be able to deliver its full capacity simultaneously.

MIDEA itself specifies that when the total load of the indoor units exceeds the nominal capacity of the outdoor unit, the actual capacity available to each unit may be reduced. The manufacturer notes that this effect is particularly noticeable in heating mode.

That is why we size a multi-zone installation as a complete system.

The correct calculation is done room by room

When selecting the three zones, we do not simply estimate the requirements based on the total area of the house.

Each room has its own heating and cooling load.

We look at, among other things:

  • its area;
  • its solar exposure;
  • the quantity and quality of the glazing;
  • insulation level;
  • ceiling height;
  • its location in the house;
  • whether there is a floor above or below;
  • airflow to neighboring rooms;
  • the actual use of the space;
  • heat loss in winter.

A relatively small bedroom does not necessarily need the same unit as a large living-dining area.

The goal is not to install the highest possible number of BTUs. Instead, we look for a combination that allows the Inverter compressor to modulate efficiently and allow the indoor units to maintain a stable temperature.

Inverter technology is especially valuable across three zones

The MIDEA multi-zone system uses inverter technology to adjust capacity according to demand.

According to the brochure, the system modulates compressor and fan motor operation as the temperature changes. When all rooms do not require cooling simultaneously, the system can operate at partial load with reduced energy consumption.

In a triple-zone home, this modulation capability is particularly useful.

Consider a common situation: a north-facing bedroom has already reached its setpoint, while a sun-exposed space still requires cooling. The system does not need to treat both rooms in exactly the same way.

In winter, the situation may be reversed. Some areas may lose more heat because of their glazing or exposure.

This flexibility explains why the indoor unit sizing is also as important as the capacity of the outdoor unit.

A range of indoor units that is not limited to wall-mounted models

The MIDEA 28 also has an interesting feature for more complex projects: the variety of compatible indoor units.

Page 4 of the brochure features wall-mounted units, consoles, cassettes, slim ducted units, and air handlers. MIDEA indicates that its range supports different applications with or without ducts.

This flexibility can be useful in a home where, for example, you want to use a wall-mounted unit in an open-plan area while choosing a more discreet solution in another area.

For the units All Easy Pro wall-mounted units, the brochure lists different capacities ranging from 6,000 BTU/h to significantly larger sizes depending on the model. The units shown are powered by 208/230 V, single-phase, 60 Hz.

What this installation in Mont-Saint-Hilaire shows before choosing a triple-zone heat pump

Outdoor clearance must be planned before making the connections

The photographed façade has several constraints: two windows, a ventilation outlet, an outdoor valve, a ground-level walkway, and various existing installations.

We therefore could not consider the entire façade as available space.

The selected position keeps access to the valve on the right, keeps the small basement window visible, and places the unit at a practical height.

This is something we recommend checking before signing an HVAC quote ask where exactly the condenser will be installed.

A very attractive quote can become much less appealing if the unit ends up in front of a window, in a passageway, too close to the ground, or in a place that is difficult to maintain.

Service access must remain possible several years after installation

A heat pump is not equipment that you install and then forget about.

At some point, a technician must be able to inspect:

  • the electrical connections;
  • the refrigerant valves;
  • the outdoor heat exchanger;
  • the fan;
  • the electronic components;
  • the connections associated with the different zones.

In the photo of this installation in Mont-Saint-Hilaire, the technical connections remain grouped on the right side of the unit, with a reasonable amount of working space around the condenser.

This detail becomes very important when heat pump maintenance or a diagnosis must be performed without dismantling building elements.

SynchroConnect and the particular complexity of a multi-zone system

In a three-zone installation, each indoor unit must be correctly associated with its circuit and wiring.

MIDEA's brochure describes its technology SynchroConnect, designed to verify the connections after the installer has connected the lines and conductors. MIDEA also indicates that, under certain conditions, the system can synchronize the correspondence between the refrigerant and electrical connections.

It is an interesting tool, but it never replaces the fundamental commissioning steps.

We must always ensure:

  1. compliant refrigerant connections;
  2. a leak test;
  3. proper vacuum pumping;
  4. safe electrical connections;
  5. validation of the three zones;
  6. testing operation in heating and cooling;
  7. verification of the indoor units' drainage.

Energy efficiency: do not use a SEER2 without verifying the combination

MIDEA's published performance varies depending on the outdoor unit and indoor units with which it is certified.

For reference, the brochure lists for a configuration Extreme Heat three-zone All Easy Pro 6K + 6K + 6K the system MO3HX-H18B-2A and the number AHRI 215471457.

For this specific combination, MIDEA publishes, among other things:

  • 19,000 BTU/h in cooling;
  • 20,000 BTU/h in heating;
  • SEER2 of 25;
  • EER2 of 15;
  • HSPF4 of 10.4;
  • power supply of 208/230 V, 1 phase, 60 Hz;
  • stated heating capacity of 19,000 BTU/h at 5 °F, or approximately -15 °C.

This data is an excellent example of why we always verify the exact AHRI number. If the three indoor units or the condenser change, the certified performance may also change.

LogisVert: the project's actual AHRI number must be verified

The MIDEA brochure contains tables specifically dedicated to combinations ENERGY STAR. This provides a useful technical basis for identifying certified combinations, but this document alone does not determine final eligibility or the amount of a Québec financial incentive.

For a LogisVert, we therefore recommend checking the combination actually installed based on:

  • the condenser model;
  • the three indoor-unit models;
  • the corresponding AHRI number;
  • the Hydro-Québec criteria in effect at the time of the application.

You should not conclude that a heat pump qualifies simply because it bears the name MIDEA 28 or because another similar MIDEA system appears in a table.

Mistakes to avoid with a triple-zone heat pump

Choosing three heads without checking the condenser

The total capacity of the indoor units must be analyzed against the outdoor unit's limits.

Putting the condenser wherever there happens to be room

In Mont-Saint-Hilaire, the presence of the windows and outdoor faucet shows why the location must be planned. A heat pump must remain accessible without obstructing the property's normal use.

Installing the unit too close to the ground

On the South Shore, snow and ice cannot be ignored. The wall-mounted setup shown here keeps the unit clearly elevated above the walkway.

Neglecting the finish of the lines

Several zones mean more connections. A structured outdoor cover helps create a neater installation that is easier to follow during future service work.

Comparing only the final price

Two so-called “triple-zone” installations may use very different condensers, indoor capacities, AHRI combinations, and installation methods.

A result that shows what we seek in our AirGreen projects

The final photo of this MIDEA 28 heat pump in Mont-Saint-Hilaire well summarizes our approach.

The condenser is elevated, the existing windows remain unobstructed, the connection route follows the building, and the existing outdoor installations remain accessible. Nothing was positioned in isolation: every element had to work with what was already present on the façade.

This level of preparation is what we apply to our heat pumps in Montreal, Laval, Longueuil, the North Shore, and the South Shore, whether it is a single-zone system or a more complex multizone installation.

With a MIDEA 28 triple-zone heat pumpthe quality of the result depends just as much on equipment selection as on how the three zones, lines, outdoor unit, and building are brought together into one coherent system.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment