Job sheet · Project

Installation of a GREE Freematch R32 two-head wall-mounted heat pump on a plexiglass roof in Saint-Hyacinthe

Two outdoor units on the same flat roof: how to prevent air recirculation, why the mounting system never penetrates the membrane, and which electrical panel should power the unit. Details of a GREE Freematch R32 installation in Saint-Hyacinthe by AirGreen.

By AirGreen Climatisation & Chauffage Admin8 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
8 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a GREE Freematch R32 two-head wall-mounted heat pump on a plexiglass roof in Saint-Hyacinthe
Installation of a GREE Freematch R32 two-head wall-mounted heat pump on a plexiglass roof in Saint-Hyacinthe
The full story

The article, chapter by chapter

Two units, one roof: the question no one asks before ordering the equipment

In the photo taken at the end of the project de Saint-Hyacinthe, two GREE outdoor units can be seen aligned on a gravel roof, each on its own aluminum support. They do not belong to the same unit. One serves the Freematch R32 multi-zone system we had just installed for the owner of the ground-floor unit; the other was already serving the upstairs apartment.

This is a common situation in the plexes of Montérégie and the Island of Montreal, and it is also one of the main sources of poorly designed installations. Because a unit that works perfectly on its own can see its performance drop by 15 to 20% simply because a neighbor installed theirs three meters away, on the wrong axis.

The assignment: air-condition two zones without affecting the neighboring unit

The building is a two-unit stacked duplex, a few streets from downtown Saint-Hyacinthe. Flat roof, gravel-covered membrane, access through an interior hatch.

The owner occupied the downstairs unit and wanted to:

  • to air-condition the double living room facing the street;
  • to cool the rear bedroom, which had poor ventilation and where the summer temperature regularly exceeded 28°C;
  • to keep the electric baseboards as supplemental heating rather than replacing them;
  • to be able to add a third zone in two or three years, when finishing the basement.

This last point directly determined the choice of equipment.

Why the GREE Freematch R32 GWHD(24)ND6MO instead of the smaller model

We installed the GWHD(24)ND6MO, an outdoor unit that accepts 2 to 3 indoor units, connected here to 2 wall-mounted heads.

An 18,000 BTU system would have been sufficient for the immediate needs. It would also have made adding a third head impossible without completely replacing the outdoor unit — meaning redoing the roof support, refrigerant lines, and electrical circuit. The additional cost of the larger model at the time of installation represented a fraction of the cost of a complete reinstallation three years later.

Outdoor unit data
Feature GWHD(24)ND6MO
Connectable indoor units 2 to 3
Rated cooling capacity 24,000 BTU/h (7,030 W) — range 7,500 to 31,400 BTU/h
Rated heating capacity 24,000 BTU/h — range 7,500 to 31,400 BTU/h
SEER2 / HSPF2 21 / 10
EER2 12 — COP 3.9
Heating down to -30 °C
Refrigerant R32 (A2L), factory charge 1,700 g
Airflow 2,236 ft³/min — 58 dB(A)
Power supply 208/230 V — MCA 19.5 A — maximum protection 25 A
Dimensions / weight 964 × 660 × 402 mm — 51 kg
Piping 30 m precharge — 60 m maximum — 15 m elevation difference
Warranty 10 years + 2 years compressor and parts

The unit is ENERGY STAR certified, approved for cold climates, and incorporates the A2L leak detection sensor required for mildly flammable refrigerants—the orange label visible on the front of the unit.

Two outdoor units sharing the same roof

This is where the Saint-Hyacinthe project becomes instructive for anyone who owns a plex or is considering a HVAC installation on a shared roof.

The recirculation phenomenon

An outdoor unit in cooling mode discharges warm air through its front. In heating mode, it discharges cold air. If a second unit draws in this discharged air, it operates with a distorted ambient air temperature—warmer in summer, colder in winter—and its compressor compensates by consuming more energy.

On an unobstructed roof, nothing is visible. The customer only notices that their bill does not decrease as much as promised.

The clearances we systematically apply:

  • 60 cm minimum behind the unit (coil intake side);
  • 1.5 m minimum in front of the discharge outlet, clear of all obstructions;
  • never place two units facing each other, nor one unit blowing toward another unit's intake;
  • 30 cm minimum above the roof surface, or higher depending on the area's historical snow accumulation.

In Saint-Hyacinthe, we positioned our unit laterally offset from the existing unit, with both blowing in the same general direction, toward the unobstructed area of the roof. Neither unit draws in air discharged by the other.

The support: aluminum on timbers, without penetration

The assembly visible in the photo:

  1. Treated wood timbers laid flat on the gravel, distributing the load across the membrane.
  2. Aluminum support bolted to the timbers; aluminum has the advantage of not rusting—an inexpensive galvanized steel support stains the membrane within five to seven years and becomes a weak point.
  3. Unit mechanically secured to the support using its original feet, with anti-vibration pads.

No fastener penetrates the membrane. This is an exception-free rule for us: as soon as a screw punctures a roof, the roofer's warranty becomes questionable and infiltration is only a matter of time.

The mistake to avoid: placing the unit directly on gravel. Gravel shifts, the unit tilts, the compressor operates in an improper position, and defrost condensate accumulates beneath the unit instead of draining away.

The electrical aspect, specific to the plex

In a multi-unit building, a heat pump must be powered from the panel serving the dwelling it serves, on a dedicated circuit. Connecting the lower unit to the upper panel because the cable route was shorter is a mistake—and a source of disputes between co-owners or between tenant and landlord.

We therefore ran a dedicated circuit from the ground-floor panel, with a disconnect within sight of the unit, in accordance with the Quebec Electrical Code. 25 A protection, with conductors sized according to the unit's 19.5 A MCA.

Running the lines and commissioning

The refrigerant lines—1/4-inch liquid, 3/8-inch gas—run along the parapet in a UV-protected insulated conduit, then descend through an existing chase to the two wall-mounted heads. Total length: approximately 19 metres, well below the 30 metres factory-precharged for this model. No additional R32 was required, which we confirmed by weighing rather than estimating.

The commissioning procedure applied:

  1. Pressurization with dry nitrogen and verified hold on both branches.
  2. Evacuation to 500 microns, with an insulation test using an electronic vacuum gauge.
  3. Opening the valves and checking superheat and subcooling.
  4. Measurement of the compressor's actual amperage under load.
  5. Supply-air temperature readings at each indoor unit.
  6. Registration of the 10+2-year warranty in the owner's name.

Duration: one and a half days, including assembly of the support and running the electrical circuit.

Grant eligibility

The Freematch R32 is ENERGY STAR certified and has distinct AHRI numbers depending on the installed configuration. For an electrically heated dwelling in Montérégie, the efficient heat pump component of the LogisVert program from Hydro-Québec is generally the applicable option.

A plex has a specific requirement: eligibility is assessed per dwelling, and the electricity account in the applicant's name must correspond to the dwelling being served. A landlord installing a system for a tenant must verify this before submitting an application — this is the most common reason for rejection we see in this type of case.

Minimum performance criteria and grant amounts change from year to year. We verify eligibility when preparing the quotation, never based on documentation from the previous year.

What we have learned from shared roofs

Every year, we install dozens of wall-mounted heat pumps on plex roofs in Montreal, Laval, Longueuil, on the North Shore, the South Shore, and in Montérégie. The lessons are consistent:

  • Survey what is already there on the roof before choosing the location, including neighbouring units and plumbing vents.
  • Document the selected location with photos and measurements for the next contractor who climbs onto that roof.
  • Leave a clear access pathway: a technician who has to step over refrigerant lines to reach a unit will eventually crush one.
  • Plan for future changes — a third zone, a finished basement, or a change in the use of a room.

For a multi-zone heat pump, wall-mounted air conditioner, or HVAC maintenance project in a multi-unit residential building, our team surveys the roof before recommending a model, not the other way around.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).