On the North Shore, from Laval to Terrebonne and from Blainville to Sainte-Thérèse, many homeowners look for a wall heat pump that costs little to run. This page puts side by side two 12,000 BTU models that the earlier article named and that AirGreen offers: their certified values, what they come to in dollars at Hydro-Québec’s Rate D, and what each manufacturer publishes when it gets very cold.

AY-XP12ZU1 / AE-X12ZU1 · AHRI 213194987
R-32 · 208-230 V · NEEP record 507399
View the product page
SENL-12CD220-ILL / SENL-12CD220-OL · AHRI 215735289
R-454B · 208-230 V · NEEP record 385692
View the product pageAirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point. The North Shore has a slightly longer winter than the Montréal station used here: the calculation is for comparing, not for predicting your bill.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.
A wall heat pump heats one zone; in extreme cold, the baseboards already in place often make up the difference. Pick a January night and the size of your zone: the dark line marks the zone’s estimated heat need, the coloured bar the maximum capacity each manufacturer publishes at that temperature, and the hatched part what would fall to the baseboards.
Estimated need: the chosen heat loss, proportional to the gap between 18 °C and the outdoor temperature (the same assumption as the cost calculation). Capacities: NEEP certified maximum (8.3, −8.3 and −15 °C; −27.2 °C for the SHARP) or the maximum SHARP publishes in its ZU/ZHU brochure (−20 and −25 °C). Nothing is calculated between two published points.
Inverter technology
Both compressors modulate. NEEP certifies a cooling range at 35 °C: 2,800 to 13,600 BTU/h for the SHARP ZU1, 1,700 to 13,300 BTU/h for the SENVILLE LETO. The LETO’s smallest cooling output is lower in summer; in heating at 8.3 °C, the SHARP goes down to 3,200 and the LETO to 3,500 BTU/h.
A SEER above 18
The pre-2023 SEER and today’s SEER2 do not compare: the SEER2 test adds a more realistic static pressure. The certificates give SEER2 22 and SEER2 21.3; that is the figure used in the summer calculation above.
Eligible for grants
Eligibility is checked in the program’s official list, on the date of the application, and its criteria can change. What NEEP shows today: SHARP ZU1 ENERGY STAR and cold climate: yes; SENVILLE LETO ENERGY STAR and cold climate: no.
A reliable unit
Reliability cannot be measured on a spec sheet. What can be checked: the stated operating range (down to −27 °C, down to −15 °C in heating), whether there is a base pan heater, and the technical documents available for each model, listed at the bottom of the page.
At −15 °C, both units have a certified point: it is the only common temperature. Lower down, SHARP publishes capacities to −27 °C; SENVILLE states heating down to −15 °C and publishes nothing colder.
SHARP: ZU/ZHU brochure (French version distributed by RBL A/C) and ZU/ZHU/BU installation manual. SENVILLE: SENL-12CD/220 sheet on senville.com and service manual SM_AB(GA)_R454B_3D INV_US_NA_2407. “Optional” is the manufacturer’s word.
SHARP ZU1 : built-in Wi-Fi.
SENVILLE LETO : Alexa control (app and voice) with the supplied USB kit; the service manual lists wireless control as optional.
SHARP ZU1 : automatic restart after a power outage.
SENVILLE LETO : auto-restart (service manual).
SHARP ZU1 : “Hot Gas Pipe”, named in the brochure.
SENVILLE LETO : defrost based on run time, coil temperature and outdoor temperature; the compressor keeps running (service manual).
SHARP ZU1 : not stated in the documents consulted.
SENVILLE LETO : 150 W base pan heater declared to NEEP; the service manual lists chassis and compressor heaters.
SHARP ZU1 : self-cleaning named in the brochure, with Plasmacluster technology.
SENVILLE LETO : “Active Clean” (service manual).
SHARP ZU1 : “Coanda” airflow and “Multi Space” named in the brochure.
SENVILLE LETO : timer, sleep, dry mode; Follow Me, 8 °C heating, Silence and ECO listed as optional.
How to read these figures. Each dot is a fan speed published by the manufacturer; the lower the number, the quieter the unit at that speed. Neither SHARP nor SENVILLE states the distance or the measurement method here.
Why this is not a ranking. Two measurements taken by unknown methods cannot be compared to the decibel: a 0.5 dB(A) gap between the two lowest speeds cannot be heard.
Measurements taken by each manufacturer by its own method: different or unstated method, not comparable to the decibel.
Scale drawing, from each indoor unit’s published width (SHARP: 34 39/64 in; SENVILLE: 31.57 in). Each manufacturer’s manual also sets the clearances to the ceiling and the sides: they add to this width.
| According to the manufacturer | SHARP ZU1 | SENVILLE LETO |
|---|---|---|
| Maximum piping length | 65.6 ftZU/ZHU/BU installation manual, EN-2 | 82.0 ftservice manual, 6k/9k/12k piping table |
| Pre-charged length | 25 ft | 24.6 ft (service manual); 25 ft per the sheet |
| Refrigerant to add beyond | 0.16 oz/ft, R-32 | 0.16 oz/ft, R-454B |
| Maximum height difference | 32.8 ft | 49.2 ft |
| Liquid – gas diameters | 1/4 – 3/8 in | not stated in the documents consulted |
| Indoor unit W × H × D, weight | 34 39/64 × 11 3/8 × 9 1/64 in, 22 lb | 31.57 × 11.69 × 7.44 in, 19.4 lb |
| Outdoor unit W × H × D, weight | 30 23/32 × 21 1/4 × 10 19/32 in, 67 lb | 30.12 × 21.85 × 11.93 in, 59.08 lb |
| Electrical protection | max. fuse 15 A, 208-230 V | MCA 13 A, max. fuse 15 A, 208-230 V |
| Stated heating / cooling range | −27 to 24 °C / −10 to 46 °C | heating down to −15 °C; cooling not stated on the sheet |
| Published outdoor sound | 50 dB(A) heating, 49 dB(A) cooling | 54,0 dB(A) |
| Dehumidification | 3.2 “Pt/h”, unit as printed in the brochure | 1.5 L/h |
higher marks the higher value of the same measure, under the same conditions. It is not a recommendation.
The earlier article named several series; these two are offered by AirGreen at 12,000 BTU with an A2L refrigerant (R-32 for the SHARP, R-454B for the LETO) and a recent AHRI certificate. The other series named were either R-410A in the store or already compared on other pages.
The running cost, calculated with the certified seasonal efficiencies and the same rate for both. The purchase price and installation are on the product page and in the quote: they depend on the job.
SENVILLE states heating down to −15 °C and publishes no capacity below that. The page does not invent a value: it shows the last certified value, 8,000 BTU/h at −15 °C, and leaves the rest to the home’s backup heat, as the HSPF2 Region V calculation does.
At the lowest speed, SHARP publishes 23 dB(A) and SENVILLE 22.5 dB(A), without stating the method. A gap this small, measured in unknown ways, does not allow a conclusion.
Amounts and criteria are read in Hydro-Québec’s official list on the date of the application; they can change. This page promises no amount.
Almost: 30 23/32 in wide for the SHARP, 30.12 in for the SENVILLE. The SHARP weighs 67 lb, the SENVILLE 59.08 lb. On a wall or a bracket, it is often the weight and the height above the snow that matter.
| Measure | SHARP ZU1 | SENVILLE LETO |
|---|---|---|
| Seasonal efficiency | ||
| SEER2 | 22 | 21.3 |
| EER2 | 12.5 | 10.8 |
| HSPF2 Region IV | 11 | 9.1 |
| HSPF2 Region V | 9.0 | 7.0 |
| Cooling at 35 °C | ||
| Capacity min. / rated / max. | 2,800 / 12,000 / 13,600 BTU/h | 1,700 / 12,000 / 13,300 BTU/h |
| Heating at 8.3 °C (47 °F) | ||
| Capacity min. / rated / max. | 3,200 / 14,000 / 17,100 BTU/h | 3,500 / 12,000 / 13,400 BTU/h |
| COP min. / rated / max. | 6.25 / 3.98 / 2.78 | 3.11 / 3.17 / 2.91 |
| Heating at −8.3 °C (17 °F) | ||
| Capacity min. / rated / max. | 3,800 / 14,500 / 14,500 BTU/h | 1,100 / 9,300 / 9,300 BTU/h |
| COP min. / rated / max. | 3.48 / 2.44 / 2.44 | 1.07 / 2.39 / 2.39 |
| Heating at −15 °C (5 °F) | ||
| Capacity min. / rated / max. | 2,950 / 12,000 / 12,000 BTU/h | 700 / 8,000 / 8,000 BTU/h |
| COP min. / rated / max. | 2.88 / 2.11 / 2.11 | 0.76 / 1.91 / 1.91 |
| Coldest certified point | ||
| Test temperature | −27.2 °C (−17 °F) | −15 °C (5 °F) |
| Capacity min. / max. | 1,500 / 7,200 BTU/h, max. COP 1.80 | 700 / 8,000 BTU/h, max. COP 1.91 |
| Certificate | ||
| Refrigerant | R-32 (GWP 675, IPCC AR4; class A2L) | R-454B (GWP 466, IPCC AR4; class A2L) |
| ENERGY STAR | Yes; cold climate: yes (NEEP) | no; cold climate: no (NEEP) |
| AHRI certificate · NEEP record | 213194987 · 507399 | 215735289 · 385692 |
higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. NEEP values read on November 17, 2026.
An assessment visit at your home, on the North Shore or elsewhere in the region, and a quote for the unit that suits your zone.
Data verified on November 17, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, sound, piping, electrical and features: according to the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails. The cost is an estimate whose method is shown above.
Trademarks. SHARP, ZU1, Plasmacluster, SENVILLE and LETO are trademarks of their respective owners. The logos only identify the products compared. AirGreen is a dealer of these brands; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us: every reported figure is checked again.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.