By the numbers · Air conditioning service

Wall air conditioner on the North Shore: what the SHARP ZU1 and the SENVILLE LETO cost, from summer to extreme cold

11 min
Comparison · Wall heat pump · 12,000 BTU · North Shore

SHARP ZU1 and SENVILLE LETO: what each season costs, from summer to extreme cold

On the North Shore, from Laval to Terrebonne and from Blainville to Sainte-Thérèse, many homeowners look for a wall heat pump that costs little to run. This page puts side by side two 12,000 BTU models that the earlier article named and that AirGreen offers: their certified values, what they come to in dollars at Hydro-Québec’s Rate D, and what each manufacturer publishes when it gets very cold.

SEER2 : 22 and 21.3HSPF2 Region V : 9.0 and 7.0Heating stated down to −27 °C and −15 °C
SHARP ZU1 12,000 BTU wall heat pump (AirGreen image)
SHARP

ZU1 · 12,000 BTU

AY-XP12ZU1 / AE-X12ZU1 · AHRI 213194987

R-32 · 208-230 V · NEEP record 507399

View the product page
SENVILLE LETO 12,000 BTU wall heat pump (AirGreen image)
SENVILLE

LETO · 12,000 BTU

SENL-12CD220-ILL / SENL-12CD220-OL · AHRI 215735289

R-454B · 208-230 V · NEEP record 385692

View the product page
Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point. The North Shore has a slightly longer winter than the Montréal station used here: the calculation is for comparing, not for predicting your bill.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.

The baseboard backup

When the heat pump is no longer enough, what heats the rest?

A wall heat pump heats one zone; in extreme cold, the baseboards already in place often make up the difference. Pick a January night and the size of your zone: the dark line marks the zone’s estimated heat need, the coloured bar the maximum capacity each manufacturer publishes at that temperature, and the hatched part what would fall to the baseboards.

Outdoor temperature

estimated zone needbaseboard sharerange between two published valueslast published value, at a warmer temperature

Estimated need: the chosen heat loss, proportional to the gap between 18 °C and the outdoor temperature (the same assumption as the cost calculation). Capacities: NEEP certified maximum (8.3, −8.3 and −15 °C; −27.2 °C for the SHARP) or the maximum SHARP publishes in its ZU/ZHU brochure (−20 and −25 °C). Nothing is calculated between two published points.

The earlier article’s criteria, checked

Four common claims, and what the documents actually say

Inverter technology

Both compressors modulate. NEEP certifies a cooling range at 35 °C: 2,800 to 13,600 BTU/h for the SHARP ZU1, 1,700 to 13,300 BTU/h for the SENVILLE LETO. The LETO’s smallest cooling output is lower in summer; in heating at 8.3 °C, the SHARP goes down to 3,200 and the LETO to 3,500 BTU/h.

A SEER above 18

The pre-2023 SEER and today’s SEER2 do not compare: the SEER2 test adds a more realistic static pressure. The certificates give SEER2 22 and SEER2 21.3; that is the figure used in the summer calculation above.

Eligible for grants

Eligibility is checked in the program’s official list, on the date of the application, and its criteria can change. What NEEP shows today: SHARP ZU1 ENERGY STAR and cold climate: yes; SENVILLE LETO ENERGY STAR and cold climate: no.

A reliable unit

Reliability cannot be measured on a spec sheet. What can be checked: the stated operating range (down to −27 °C, down to −15 °C in heating), whether there is a base pan heater, and the technical documents available for each model, listed at the bottom of the page.

Extreme cold

Below −15 °C, what each manufacturer publishes

At −15 °C, both units have a certified point: it is the only common temperature. Lower down, SHARP publishes capacities to −27 °C; SENVILLE states heating down to −15 °C and publishes nothing colder.

Documented features

What each manufacturer writes, group by group

SHARP: ZU/ZHU brochure (French version distributed by RBL A/C) and ZU/ZHU/BU installation manual. SENVILLE: SENL-12CD/220 sheet on senville.com and service manual SM_AB(GA)_R454B_3D INV_US_NA_2407. “Optional” is the manufacturer’s word.

Wi-Fi and app

SHARP ZU1 : built-in Wi-Fi.

SENVILLE LETO : Alexa control (app and voice) with the supplied USB kit; the service manual lists wireless control as optional.

Auto restart

SHARP ZU1 : automatic restart after a power outage.

SENVILLE LETO : auto-restart (service manual).

Defrost

SHARP ZU1 : “Hot Gas Pipe”, named in the brochure.

SENVILLE LETO : defrost based on run time, coil temperature and outdoor temperature; the compressor keeps running (service manual).

Base pan heater

SHARP ZU1 : not stated in the documents consulted.

SENVILLE LETO : 150 W base pan heater declared to NEEP; the service manual lists chassis and compressor heaters.

Indoor unit cleaning

SHARP ZU1 : self-cleaning named in the brochure, with Plasmacluster technology.

SENVILLE LETO : “Active Clean” (service manual).

Modes and comfort

SHARP ZU1 : “Coanda” airflow and “Multi Space” named in the brochure.

SENVILLE LETO : timer, sleep, dry mode; Follow Me, 8 °C heating, Silence and ECO listed as optional.

Sound

The published sound level, speed by speed

dB(A)

How to read these figures. Each dot is a fan speed published by the manufacturer; the lower the number, the quieter the unit at that speed. Neither SHARP nor SENVILLE states the distance or the measurement method here.

Why this is not a ranking. Two measurements taken by unknown methods cannot be compared to the decibel: a 0.5 dB(A) gap between the two lowest speeds cannot be heard.

Measurements taken by each manufacturer by its own method: different or unstated method, not comparable to the decibel.

Installation

On your wall and outside

Scale drawing, from each indoor unit’s published width (SHARP: 34 39/64 in; SENVILLE: 31.57 in). Each manufacturer’s manual also sets the clearances to the ceiling and the sides: they add to this width.

According to the manufacturerSHARP ZU1SENVILLE LETO
Maximum piping length65.6 ftZU/ZHU/BU installation manual, EN-282.0 ftservice manual, 6k/9k/12k piping table
Pre-charged length25 ft24.6 ft (service manual); 25 ft per the sheet
Refrigerant to add beyond0.16 oz/ft, R-320.16 oz/ft, R-454B
Maximum height difference32.8 ft49.2 ft
Liquid – gas diameters1/4 – 3/8 innot stated in the documents consulted
Indoor unit W × H × D, weight34 39/64 × 11 3/8 × 9 1/64 in, 22 lb31.57 × 11.69 × 7.44 in, 19.4 lb
Outdoor unit W × H × D, weight30 23/32 × 21 1/4 × 10 19/32 in, 67 lb30.12 × 21.85 × 11.93 in, 59.08 lb
Electrical protectionmax. fuse 15 A, 208-230 VMCA 13 A, max. fuse 15 A, 208-230 V
Stated heating / cooling range−27 to 24 °C / −10 to 46 °Cheating down to −15 °C; cooling not stated on the sheet
Published outdoor sound50 dB(A) heating, 49 dB(A) cooling54,0 dB(A)
Dehumidification3.2 “Pt/h”, unit as printed in the brochure1.5 L/h

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation.

Frequently asked questions

What we get asked about these two wall units

Why the SHARP ZU1 and the SENVILLE LETO?

The earlier article named several series; these two are offered by AirGreen at 12,000 BTU with an A2L refrigerant (R-32 for the SHARP, R-454B for the LETO) and a recent AHRI certificate. The other series named were either R-410A in the store or already compared on other pages.

“Economical”: what does this page compare?

The running cost, calculated with the certified seasonal efficiencies and the same rate for both. The purchase price and installation are on the product page and in the quote: they depend on the job.

And below −15 °C with the SENVILLE LETO?

SENVILLE states heating down to −15 °C and publishes no capacity below that. The page does not invent a value: it shows the last certified value, 8,000 BTU/h at −15 °C, and leaves the rest to the home’s backup heat, as the HSPF2 Region V calculation does.

Which one is the quietest?

At the lowest speed, SHARP publishes 23 dB(A) and SENVILLE 22.5 dB(A), without stating the method. A gap this small, measured in unknown ways, does not allow a conclusion.

LogisVert and other programs

Amounts and criteria are read in Hydro-Québec’s official list on the date of the application; they can change. This page promises no amount.

Do the two outdoor units take the same space?

Almost: 30 23/32 in wide for the SHARP, 30.12 in for the SENVILLE. The SHARP weighs 67 lb, the SENVILLE 59.08 lb. On a wall or a bracket, it is often the weight and the height above the snow that matter.

Certified data

The values of both certificates, line by line

MeasureSHARP ZU1SENVILLE LETO
Seasonal efficiency
SEER22221.3
EER212.510.8
HSPF2 Region IV119.1
HSPF2 Region V9.07.0
Cooling at 35 °C
Capacity min. / rated / max.2,800 / 12,000 / 13,600 BTU/h1,700 / 12,000 / 13,300 BTU/h
Heating at 8.3 °C (47 °F)
Capacity min. / rated / max.3,200 / 14,000 / 17,100 BTU/h3,500 / 12,000 / 13,400 BTU/h
COP min. / rated / max.6.25 / 3.98 / 2.783.11 / 3.17 / 2.91
Heating at −8.3 °C (17 °F)
Capacity min. / rated / max.3,800 / 14,500 / 14,500 BTU/h1,100 / 9,300 / 9,300 BTU/h
COP min. / rated / max.3.48 / 2.44 / 2.441.07 / 2.39 / 2.39
Heating at −15 °C (5 °F)
Capacity min. / rated / max.2,950 / 12,000 / 12,000 BTU/h700 / 8,000 / 8,000 BTU/h
COP min. / rated / max.2.88 / 2.11 / 2.110.76 / 1.91 / 1.91
Coldest certified point
Test temperature−27.2 °C (−17 °F)−15 °C (5 °F)
Capacity min. / max.1,500 / 7,200 BTU/h, max. COP 1.80700 / 8,000 BTU/h, max. COP 1.91
Certificate
RefrigerantR-32 (GWP 675, IPCC AR4; class A2L)R-454B (GWP 466, IPCC AR4; class A2L)
ENERGY STARYes; cold climate: yes (NEEP)no; cold climate: no (NEEP)
AHRI certificate · NEEP record213194987 · 507399215735289 · 385692

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. NEEP values read on November 17, 2026.

Both are on the AirGreen site.

An assessment visit at your home, on the North Shore or elsewhere in the region, and a quote for the unit that suits your zone.

Sources

Documents consulted

NEEP, record 507399SHARP AY-XP12ZU1 / AE-X12ZU1, AHRI 213194987; consulted November 17, 2026.
NEEP, record 385692SENVILLE SENL-12CD220-ILL / -OL, AHRI 215735289; consulted November 17, 2026.
SHARP, ZU/ZHU brochure (French)Distributed by RBL A/C, undated; 12,000 BTU column printed AY-XPC12ZU / AE-X12ZU (values identical to the ZU1 certificate at the common points); consulted November 17, 2026.
SHARP, ZU/ZHU/BU installation manualglobal.sharp, no printed code, p. EN-2 (piping); consulted November 17, 2026.
SENVILLE, SENL-12CD/220 sheetsenville.com, product technical sheet; consulted November 17, 2026.
SENVILLE, LETO service manualSM_AB(GA)_R454B_3D INV_US_NA_2407 (senville.com); consulted November 17, 2026.
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5; consulted November 9, 2026. Rates change every April 1.
NRCan, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C base), design temperature −23.1 °C; consulted November 9, 2026.
You made it to the end.Share it with someone it could help.

Leave a comment