FUJITSU AIRSTAGE, GREE and LG, each in 2 zones with two wall heads, at the same certified 18,000 BTU/h size. Rather than a home-made test, here is what the AHRI certificates and each manufacturer’s documents publish, degree by degree, down to −30 °C, with the estimated cost for Montréal.
FUJITSU AIRSTAGEAOUH18KWAH2 + 2 × ASUH09KPAS · AHRI 215447691
View the product page
GREEGWHD(18)ND6MO + ductless indoor units · AHRI 214931586
View the product page
LGKUMXA181A + ductless indoor units · AHRI 214848473
View the product pageShown in alphabetical order of brand. All three use R-32, are certified with ductless indoor units and are ENERGY STAR cold climate certified.
AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec rate D, taxes included. All three heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. The coin panel shows the first two in alphabetical order; the “All three, same calculation” table gives all three.
Follows the sliders and price chosen above. Display order is up to you.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
At −15 °C, all three certificates give a value at the same temperature. Further down, each stops somewhere else: −25 °C for the LG, −26.1 °C for the FUJITSU AIRSTAGE, −30 °C for the GREE. Between two published values, the page shows the range that links them, each end with its temperature; below the last value, it shows that point and what the manufacturer says beyond it.
| Outdoor temperature | AQUILA XLTH | FREEMATCH R32 | Multi F LGRED |
|---|
Nothing is calculated between two published points. Maximum capacities, outdoor unit at full speed, 21.1 °C indoors for the manufacturers’ tables. LG’s heating range is given in wet bulb (−13 °F).
AQUILA XLTH: yes, heats below 2 °C (36 °F). FREEMATCH R32: yes, included, 72 W. Multi F LGRED: yes, standard.
FUJITSU AIRSTAGE brochure FG2057B; GREE Canada GWHD(18)ND6MO submittal; LG engineering manual.AQUILA XLTH: “no lockout”, heating stated down to −26 °C. FREEMATCH R32: heating stated down to −30 °C. Multi F LGRED: heating stated down to −13 °F wet bulb.
FG2057B p. 18; GREE brochure X610068B; LG KUMXA181A submittal.AQUILA XLTH: down to −10 °C. FREEMATCH R32: down to −30 °C. Multi F LGRED: down to −10 °C, or −20 °C with the optional ZLABGP04A/B wind baffle.
Same documents.AQUILA XLTH: 14,000 to 24,000 BTU/h. FREEMATCH R32: 10,000 to 24,000 BTU/h. Multi F LGRED: LG combination tables; the certificate covers ductless wall heads.
FG2057B; GREE Canada combination table; LG performance data manual.Each published step, in cooling.
Cooling and heating when the manufacturer publishes both.
How to read these figures. dB(A) measures a noise level; the lower the number, the quieter. Each dot is a speed published by the manufacturer.
Why this is not a ranking. Each manufacturer measures its own way, at a distance it does not always publish; two figures from two documents cannot be compared to the decibel.
Measurements taken by each manufacturer with its own method: read them separately, not as a ranking.
| Installation | AQUILA XLTH | FREEMATCH R32 | Multi F LGRED |
|---|---|---|---|
| Maximum piping lengthTotal for both heads | 164 ft82 ft per head | 131 ft65.6 ft per head | 164 ft82 ft per head |
| Pre-charged length | 98 ft | 33 ftthen 0.2 oz per foot | 82 ftthen 0.22 oz per foot |
| Maximum height difference | 49 ft33 ft between heads | 49 ftsame value between heads | 49.2 ft24.6 ft between heads |
| Liquid – gas diametersPer head | 1/4 – 3/8 in | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 32 5/16 × 34 13/16 × 12 3/8 in, 117 lb | 32 3/8 × 21 11/16 × 13 7/8 in, 78.3 lbThe GREE Canada submittal gives 75 lb. | 37 13/32 × 32 27/32 × 13 in, 147.7 lb |
| Indoor unit, weight9,000 BTU/h wall head | 21 lbASUH09KPAS | 19.8 lbCHARMO GWH09ATCXB | 19.7 lbKNUAB091A |
| Electrical protectionPer the manufacturer | 20 A breakerMCA 19.9 A | MOCP 20 AMCA 14.5 A; 18.5 A per the GREE Canada submittal | MOP 30 AMCA 22.7 A |
| Stated heating / cooling range | −26 to 24 °C / −10 to 50 °C | −30 to 24 °C / −30 to 48 °C | −25 to 18 °C / −10 to 48 °CHeating in wet bulb |
The bars compare the three values of one row, on one scale. Clearances around the outdoor unit: figure in each model’s installation manual.
All three heat below −25 °C according to their manufacturers, but only one has a certified value at −30 °C: the GREE FREEMATCH R32, 10,200 BTU/h maximum (NEEP, AHRI 214931586). The FUJITSU AIRSTAGE AQUILA XLTH has its last certified point at −26.1 °C (12,060 BTU/h), and FUJITSU AIRSTAGE writes that it has no lockout. The LG Multi F LGRED has its last point at −25 °C (17,830 BTU/h) and a stated range down to −13 °F wet bulb. Three different temperatures: none of them reads as a ranking.
No. They are the AHRI certificate values published by NEEP and those from the manufacturers’ documents, cited at the end of the page. A test in a house depends on the house; a certificate is measured under the same conditions for everyone.
The 18,000 BTU/h is the rated cooling capacity at 35 °C, the same in all three certificates. In heating during extreme cold, each outdoor unit delivers what it can: at −15 °C, 22,000 BTU/h maximum for the AQUILA XLTH and the Multi F LGRED, 13,800 for the FREEMATCH R32.
When a manufacturer publishes nothing at a temperature, the page shows the two published values on either side, each with its own temperature and source. The actual value is not published, and it is not calculated either.
No. It is an estimate made with the same method for all three systems, for an 18,000 BTU/h zone in Montréal. It is for comparing; the actual bill depends on the house, the settings and the use.
It depends on the house’s heat loss, not only on the heat pump. The HSPF2 Region V method already includes electric backup when the heat pump is no longer enough. An on-site assessment gives the actual heat loss.
| Certified value | AQUILA XLTH | FREEMATCH R32 | Multi F LGRED |
|---|---|---|---|
| Rated capacity at 35 °C | 18,000 BTU/h | 18,000 BTU/h | 18,000 BTU/h |
| SEER2 | 22.0 | 21.0 | 20.0 |
| EER2 | 13.5 | 12.0 | 13.5 |
| HSPF2 Region IV | 11.0 | 10.0 | 9.8 |
| HSPF2 Region V | 9.3 | 8.0 | 8.1 |
| Heating at 8.3 °C (47 °F) | |||
| Min. / rated / max. capacity | 6,800 / 22,000 / 25,000 BTU/h | 7,000 / 18,000 / 18,100 BTU/h | 10,248 / 22,000 / 24,000 BTU/h |
| COP min. / rated / max. | 4.53 / 4.39 / 4.39 | 3.95 / 3.91 / 3.21 | 3.00 / 3.60 / 2.80 |
| Heating at −8.3 °C (17 °F) | |||
| Min. / rated / max. capacity | 4,700 / 14,800 / 22,800 BTU/h | 7,200 / 17,600 / 17,600 BTU/h | 7,511 / 13,900 / 23,600 BTU/h |
| COP min. / rated / max. | 3.28 / 3.24 / 2.58 | 3.25 / 2.36 / 2.36 | 2.50 / 2.59 / 2.56 |
| Heating at −15 °C (5 °F) | |||
| Min. / rated / max. capacity | 3,900 / 22,000 / 22,000 BTU/h | 7,200 / 13,800 / 13,800 BTU/h | 6,262 / 19,800 / 22,000 BTU/h |
| COP min. / rated / max. | 2.79 / 2.18 / 2.18 | 2.45 / 2.00 / 2.00 | 2.16 / 1.85 / 2.25 |
| Coldest point on the certificate | |||
| Test temperature | −26.1 °C (−15 °F) | −30 °C (−22 °F) | −25 °C (−13 °F) |
| Min. / max. capacity | 2,500 / 12,060 BTU/h | 7,000 / 10,200 BTU/h | 4,636 / 17,830 BTU/h |
| COP min. / max. | 1.83 / 2.02 | 1.55 / 1.51 | 2.00 / 2.31 |
| Certification | |||
| Refrigerant | R-32GWP 675 (IPCC, Fourth Assessment Report) · A2L (ASHRAE 34) | R-32GWP 675 (IPCC, Fourth Assessment Report) · A2L (ASHRAE 34) | R-32GWP 675 (IPCC, Fourth Assessment Report) · A2L (ASHRAE 34) |
| ENERGY STAR, cold climate | Yes; cold climate: yes | Yes; cold climate: yes | Yes; cold climate: yes |
| AHRI certificate · NEEP record | 215447691 · 455168 | 214931586 · 392112 | 214848473 · 392659 |
“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities at the three coldest points are measured at three different temperatures: nothing is highlighted.
A question about the size, the number of heads or the piping for your house? Write or call us.
Data verified on November 16, 2026. Certified values: AHRI certificates published by NEEP. Declared values: manufacturer documents cited above. Cost: AirGreen estimate, method v1.1, not a promise.
FUJITSU AIRSTAGE, AQUILA, GREE, FREEMATCH, LG, Multi F and LGRED are trademarks of their owners. Logos and images are used only to identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.