AirGreen lexiconMulti-zone heat pumps

Multi-zone heat pump at −30 °C in Montréal: FUJITSU AIRSTAGE, GREE and LG in 2 zones, figure by figure

10 min
Comparison · Multi-zone · 3 systems, 2 zones, 18,000 BTU

Three 18,000 BTU multi-zones, one night at −30 °C: what each one publishes

FUJITSU AIRSTAGE, GREE and LG, each in 2 zones with two wall heads, at the same certified 18,000 BTU/h size. Rather than a home-made test, here is what the AHRI certificates and each manufacturer’s documents publish, degree by degree, down to −30 °C, with the estimated cost for Montréal.

FUJITSU AIRSTAGE AQUILA XLTH, outdoor unit and two wall heads FUJITSU AIRSTAGE

AQUILA XLTH · 2 zones

AOUH18KWAH2 + 2 × ASUH09KPAS · AHRI 215447691

View the product page
GREE FREEMATCH R32, outdoor unit and two wall heads GREE

FREEMATCH R32 · 2 zones

GWHD(18)ND6MO + ductless indoor units · AHRI 214931586

View the product page

Shown in alphabetical order of brand. All three use R-32, are certified with ductless indoor units and are ENERGY STAR cold climate certified.

Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec rate D, taxes included. All three heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. The coin panel shows the first two in alphabetical order; the “All three, same calculation” table gives all three.

All three, same calculation

Follows the sliders and price chosen above. Display order is up to you.

WinterSummerYear
How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 18,000 BTU/h (0 kW) at −23.1 °C, the Montréal design temperature: 0 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 0 kWh of heat for 24-hour heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), heat is reduced in the same proportion, for the heat pump as for the baseboards: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec rate D in force on April 1, 2026: 7.065 ¢ per kWh up to 40 kWh per day, 11.142 ¢ beyond; the average price, 9.104 ¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Down to −30 °C

Degree by degree, what each manufacturer publishes

At −15 °C, all three certificates give a value at the same temperature. Further down, each stops somewhere else: −25 °C for the LG, −26.1 °C for the FUJITSU AIRSTAGE, −30 °C for the GREE. Between two published values, the page shows the range that links them, each end with its temperature; below the last value, it shows that point and what the manufacturer says beyond it.

−15 °C

NEEP certified per the manufacturer, not certifiedHatching: range between two published values · dotted outline: last published value
Outdoor temperatureAQUILA XLTHFREEMATCH R32Multi F LGRED

Nothing is calculated between two published points. Maximum capacities, outdoor unit at full speed, 21.1 °C indoors for the manufacturers’ tables. LG’s heating range is given in wet bulb (−13 °F).

Features

What each manufacturer writes about extreme cold

Outdoor unit base pan heater

AQUILA XLTH: yes, heats below 2 °C (36 °F). FREEMATCH R32: yes, included, 72 W. Multi F LGRED: yes, standard.

FUJITSU AIRSTAGE brochure FG2057B; GREE Canada GWHD(18)ND6MO submittal; LG engineering manual.
Cut-off in extreme cold

AQUILA XLTH: “no lockout”, heating stated down to −26 °C. FREEMATCH R32: heating stated down to −30 °C. Multi F LGRED: heating stated down to −13 °F wet bulb.

FG2057B p. 18; GREE brochure X610068B; LG KUMXA181A submittal.
Low-ambient cooling

AQUILA XLTH: down to −10 °C. FREEMATCH R32: down to −30 °C. Multi F LGRED: down to −10 °C, or −20 °C with the optional ZLABGP04A/B wind baffle.

Same documents.
Connectable capacity, two heads

AQUILA XLTH: 14,000 to 24,000 BTU/h. FREEMATCH R32: 10,000 to 24,000 BTU/h. Multi F LGRED: LG combination tables; the certificate covers ductless wall heads.

FG2057B; GREE Canada combination table; LG performance data manual.
Sound

Three heads, three outdoor units

9,000 BTU/h wall head, in the room

Each published step, in cooling.

Outdoor unit, outside

Cooling and heating when the manufacturer publishes both.

dB

How to read these figures. dB(A) measures a noise level; the lower the number, the quieter. Each dot is a speed published by the manufacturer.

Why this is not a ranking. Each manufacturer measures its own way, at a distance it does not always publish; two figures from two documents cannot be compared to the decibel.

Measurements taken by each manufacturer with its own method: read them separately, not as a ranking.

Installation

Piping, weight and electrical

InstallationAQUILA XLTHFREEMATCH R32Multi F LGRED
Maximum piping lengthTotal for both heads164 ft82 ft per head131 ft65.6 ft per head164 ft82 ft per head
Pre-charged length98 ft33 ftthen 0.2 oz per foot82 ftthen 0.22 oz per foot
Maximum height difference49 ft33 ft between heads49 ftsame value between heads49.2 ft24.6 ft between heads
Liquid – gas diametersPer head1/4 – 3/8 in1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight32 5/16 × 34 13/16 × 12 3/8 in, 117 lb32 3/8 × 21 11/16 × 13 7/8 in, 78.3 lbThe GREE Canada submittal gives 75 lb.37 13/32 × 32 27/32 × 13 in, 147.7 lb
Indoor unit, weight9,000 BTU/h wall head21 lbASUH09KPAS19.8 lbCHARMO GWH09ATCXB19.7 lbKNUAB091A
Electrical protectionPer the manufacturer20 A breakerMCA 19.9 AMOCP 20 AMCA 14.5 A; 18.5 A per the GREE Canada submittalMOP 30 AMCA 22.7 A
Stated heating / cooling range−26 to 24 °C / −10 to 50 °C−30 to 24 °C / −30 to 48 °C−25 to 18 °C / −10 to 48 °CHeating in wet bulb

The bars compare the three values of one row, on one scale. Clearances around the outdoor unit: figure in each model’s installation manual.

Questions

What people ask us about heating at −30 °C

Which one heats at −30 °C?

All three heat below −25 °C according to their manufacturers, but only one has a certified value at −30 °C: the GREE FREEMATCH R32, 10,200 BTU/h maximum (NEEP, AHRI 214931586). The FUJITSU AIRSTAGE AQUILA XLTH has its last certified point at −26.1 °C (12,060 BTU/h), and FUJITSU AIRSTAGE writes that it has no lockout. The LG Multi F LGRED has its last point at −25 °C (17,830 BTU/h) and a stated range down to −13 °F wet bulb. Three different temperatures: none of them reads as a ranking.

Do these figures come from an AirGreen test?

No. They are the AHRI certificate values published by NEEP and those from the manufacturers’ documents, cited at the end of the page. A test in a house depends on the house; a certificate is measured under the same conditions for everyone.

Why different capacities when all three are 18,000 BTU?

The 18,000 BTU/h is the rated cooling capacity at 35 °C, the same in all three certificates. In heating during extreme cold, each outdoor unit delivers what it can: at −15 °C, 22,000 BTU/h maximum for the AQUILA XLTH and the Multi F LGRED, 13,800 for the FREEMATCH R32.

What does “range” mean here?

When a manufacturer publishes nothing at a temperature, the page shows the two published values on either side, each with its own temperature and source. The actual value is not published, and it is not calculated either.

Is the estimated cost my bill?

No. It is an estimate made with the same method for all three systems, for an 18,000 BTU/h zone in Montréal. It is for comparing; the actual bill depends on the house, the settings and the use.

Do I need another heat source in extreme cold?

It depends on the house’s heat loss, not only on the heat pump. The HSPF2 Region V method already includes electric backup when the heat pump is no longer enough. An on-site assessment gives the actual heat loss.

Certified data

The values of the three certificates, line by line

Certified valueAQUILA XLTHFREEMATCH R32Multi F LGRED
Rated capacity at 35 °C18,000 BTU/h18,000 BTU/h18,000 BTU/h
SEER222.021.020.0
EER213.512.013.5
HSPF2 Region IV11.010.09.8
HSPF2 Region V9.38.08.1
Heating at 8.3 °C (47 °F)
Min. / rated / max. capacity6,800 / 22,000 / 25,000 BTU/h7,000 / 18,000 / 18,100 BTU/h10,248 / 22,000 / 24,000 BTU/h
COP min. / rated / max.4.53 / 4.39 / 4.393.95 / 3.91 / 3.213.00 / 3.60 / 2.80
Heating at −8.3 °C (17 °F)
Min. / rated / max. capacity4,700 / 14,800 / 22,800 BTU/h7,200 / 17,600 / 17,600 BTU/h7,511 / 13,900 / 23,600 BTU/h
COP min. / rated / max.3.28 / 3.24 / 2.583.25 / 2.36 / 2.362.50 / 2.59 / 2.56
Heating at −15 °C (5 °F)
Min. / rated / max. capacity3,900 / 22,000 / 22,000 BTU/h7,200 / 13,800 / 13,800 BTU/h6,262 / 19,800 / 22,000 BTU/h
COP min. / rated / max.2.79 / 2.18 / 2.182.45 / 2.00 / 2.002.16 / 1.85 / 2.25
Coldest point on the certificate
Test temperature−26.1 °C (−15 °F)−30 °C (−22 °F)−25 °C (−13 °F)
Min. / max. capacity2,500 / 12,060 BTU/h7,000 / 10,200 BTU/h4,636 / 17,830 BTU/h
COP min. / max.1.83 / 2.021.55 / 1.512.00 / 2.31
Certification
RefrigerantR-32GWP 675 (IPCC, Fourth Assessment Report) · A2L (ASHRAE 34)R-32GWP 675 (IPCC, Fourth Assessment Report) · A2L (ASHRAE 34)R-32GWP 675 (IPCC, Fourth Assessment Report) · A2L (ASHRAE 34)
ENERGY STAR, cold climateYes; cold climate: yesYes; cold climate: yesYes; cold climate: yes
AHRI certificate · NEEP record215447691 · 455168214931586 · 392112214848473 · 392659

“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities at the three coldest points are measured at three different temperatures: nothing is highlighted.

All three are on the AirGreen website.

A question about the size, the number of heads or the piping for your house? Write or call us.

(514) 316-2973Request a quote
Sources

Documents consulted

NEEP, record 455168 (FUJITSU AIRSTAGE, AOUH18KWAH2)AHRI 215447691 · accessed November 16, 2026
NEEP, record 392112 (GREE, GWHD(18)ND6MO)AHRI 214931586 · accessed November 16, 2026
NEEP, record 392659 (LG, KUMXA181A)AHRI 214848473 · accessed November 16, 2026
ENERGY STAR, heat pump databaseCold climate: yes for all three (certified June 23, 2026, March 17, 2026 and March 4, 2025) · accessed November 16, 2026
FUJITSU AIRSTAGE, H Series Multi-Zone / AQUILA XLTH brochureFG2057B, rev. 8/2025 (FR) · ranges, “no lockout” (p. 18), piping, dimensions, sound, electrical
GREE, FREEMATCH R32 brochureDocument X610068B · piping, electrical, ranges
GREE Canada, GWHD(18)ND6MO submittalUndated · combination table, base pan heater, weight, MCA · accessed November 9, 2026
GREE, Multi R32 and CHARMO R32 service manualsOutdoor units pp. 2 and 3; GWH09ATCXB head p. 9 (sound, weight) · accessed November 9, 2026
LG, Multi F and Multi F MAX with LGRED performance data manualPD_Multi_F-MAX_LGRED_ODU_R32_01_26 · p. 759, maximum capacity, 9 + 9 combination · accessed November 9, 2026
LG, KUMXA181A engineering manual and submittalSB_Multi_F_LGRED_ODU_R32_KUMXA181A_1_26A · dimensions, weight, piping, ranges, sound, MOP and MCA
LG, KNUAB091A wall unit submittalSB_MultiF_HiEff_WallMounted_IDU_R32_KNUAB091A (January 10, 2025) · sound, weight
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · accessed November 16, 2026
NRCan, HOT2000 climate dataMontréal Intl: 4,167 degree-days (base 18 °C), design temperature −23.1 °C