FUJITSU AIRSTAGEAQUILA XLTH · 2 zones
AOUH24KWAH3 + ductless indoor units · AHRI 215447693
View the product pageThe gist
In Longueuil, what “the brand” changes on a multi-zone heat pump can be checked: FUJITSU AIRSTAGE AQUILA XLTH and GREE FREEMATCH R32 at 24,000 BTU in 2 zones, compared by their AHRI certificates, capacity in extreme cold, estimated cost and six facts you can check yourself.
In Longueuil as elsewhere, “the brand” comes down to facts anyone can check: a certificate, a capacity in extreme cold, a stated range, documents. Here are those facts for two 24,000 BTU multi-zones in 2 zones, with the estimated cost and how to check them yourself.
FUJITSU AIRSTAGEAOUH24KWAH3 + ductless indoor units · AHRI 215447693
View the product page
GREEGWHD(24)ND6MO + ductless indoor units · AHRI 214931587
View the product pageAirGreen cards for each series. Two R-32 outdoor units, ENERGY STAR cold climate certified.
AirGreen estimate for the same 24,000 BTU/h zone in Longueuil, using Montréal climate data, at Hydro-Québec rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. The certificates give 22,000 BTU/h (FUJITSU AIRSTAGE) and 24,000 BTU/h (GREE) of cooling at 35 °C: the calculation uses the common 24,000 BTU/h size.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
A reputation cannot be checked; a certificate can. Go through the six points: each shows the value for both systems and where to find it.
At −15 °C, both certificates give a value at the same temperature: 25,200 and 21,600 BTU/h maximum. Further down, the FUJITSU AIRSTAGE has its last certified point at −26.1 °C, the GREE at −30 °C. Between two published values, the page shows the range, each end with its temperature.
AQUILA XLTH: yes, it heats below 2 °C (36 °F). FREEMATCH R32: brochure X610068B does not mention one for this model.
FG2057B; X610068B.AQUILA XLTH: “no lockout”, heating stated down to −26 °C. FREEMATCH R32: heating stated down to −30 °C.
FG2057B; X610068B.AQUILA XLTH: down to −10 °C. FREEMATCH R32: down to −30 °C.
Same documents.Head noise depends on the wall series chosen; see each head’s submittal.
How to read these figures. dB(A) measures a noise level; the lower the number, the quieter.
Why this is not a ranking. FUJITSU AIRSTAGE publishes cooling and heating; GREE publishes a single figure at high speed. Two methods, two documents.
Measurements taken by each manufacturer with its own method: read them separately, not as a ranking.
| Installation | AQUILA XLTH | FREEMATCH R32 |
|---|---|---|
| Maximum piping length | 230 ft82 ft per head; at least 33 ft in total | 197 ftMaximum per head not given in the brochure |
| Pre-charged length | 98 ftExtra charge per foot not given in the brochure | 98 ftthen 0.2 oz per foot |
| Maximum height difference | 49 ft33 ft between heads | 49 ft |
| Liquid – gas diameters | 1/4 – 3/8 inor 1/4 – 1/2 in on one port | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 32 5/16 × 34 13/16 × 12 3/8 in, 119 lb | 37 15/16 × 26 × 15 13/16 in, 112.5 lb |
| Electrical protectionPer the manufacturer | 25 A breakerMCA 13.6 A | MOCP 25 AMCA 19.5 A |
| Connectable capacityTotal of the heads | 14,000 to 31,000 BTU/h | 7,500 to 31,400 BTU/h |
| Maximum number of indoor units | 3 | 2Per brochure X610068B |
| Stated heating / cooling range | −26 to 24 °C / −10 to 50 °C | −30 to 24 °C / −30 to 48 °C |
Clearances around the outdoor unit: figure in each model’s installation manual. The exact piping length is measured on site.
What counts are the values of the exact model, not the name on the box. These two 24,000 BTU/h systems have different certificates: HSPF2 Region V of 9.0 and 8.0, SEER2 of 23.5 and 21.0, last certified point at −26.1 °C and at −30 °C. The “Check it yourself” panel shows where to find each figure.
GREE brochure X610068B gives at most 2 indoor units for the GWHD(24)ND6MO, so the page compares both systems in 2 zones. The 24,000 BTU/h AQUILA XLTH accepts up to 3 heads per FUJITSU AIRSTAGE.
No. They are the AHRI certificate values published by NEEP and those from the manufacturers’ brochures. They apply in Longueuil as in Montréal; the cost uses Montréal climate data, the closest reference station.
Eligibility depends on Hydro-Québec’s official list on the date of the application; this page promises no amount. Each system’s AHRI number lets you look it up in the list.
No. It is an estimate made with the same method for both systems. The actual bill depends on the house, the settings and the use.
| Certified value | AQUILA XLTH | FREEMATCH R32 |
|---|---|---|
| Rated capacity at 35 °C | 22,000 BTU/h | 24,000 BTU/h |
| SEER2 | 23.5 | 21.0 |
| EER2 | 13.5 | 13.3 |
| HSPF2 Region IV | 11.5 | 10.0 |
| HSPF2 Region V | 9.0 | 8.0 |
| Heating at 8.3 °C (47 °F) | ||
| Min. / rated / max. capacity | 6,800 / 25,000 / 31,000 BTU/h | 7,500 / 24,000 / 28,800 BTU/h |
| COP min. / rated / max. | 5.54 / 4.70 / 4.41 | 3.93 / 3.91 / 3.22 |
| Heating at −8.3 °C (17 °F) | ||
| Min. / rated / max. capacity | 4,700 / 16,200 / 26,800 BTU/h | 8,200 / 23,600 / 26,600 BTU/h |
| COP min. / rated / max. | 3.83 / 3.34 / 2.53 | 3.20 / 2.45 / 2.30 |
| Heating at −15 °C (5 °F) | ||
| Min. / rated / max. capacity | 3,900 / 25,200 / 25,200 BTU/h | 8,200 / 21,600 / 21,600 BTU/h |
| COP min. / rated / max. | 3.17 / 2.10 / 2.10 | 2.50 / 2.00 / 2.00 |
| Coldest point on the certificate | ||
| Test temperature | −26.1 °C (−15 °F) | −30 °C (−22 °F) |
| Min. / max. capacity | 2,500 / 14,000 BTU/h | 7,000 / 17,400 BTU/h |
| COP min. / max. | 2.04 / 1.68 | 1.51 / 1.50 |
| Certification | ||
| Refrigerant | R-32GWP 675 (IPCC, Fourth Assessment Report) · A2L (ASHRAE 34) | R-32GWP 675 (IPCC, Fourth Assessment Report) · A2L (ASHRAE 34) |
| ENERGY STAR, cold climate | Yes; cold climate: yes | Yes; cold climate: yes |
| AHRI certificate · NEEP record | 215447693 · 455167 | 214931587 · 392111 |
“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Coldest points: two different temperatures, nothing highlighted.
A question about the number of heads, the piping or where the outdoor unit goes in Longueuil? Write or call us.
Data verified on November 16, 2026. Certified values: AHRI certificates published by NEEP. Declared values: manufacturer brochures cited above. Cost: AirGreen estimate, method v1.1, not a promise.
FUJITSU AIRSTAGE, AQUILA, GREE and FREEMATCH are trademarks of their owners. Logos and images are used only to identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen cards for each series, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.