AirGreen lexiconWall-mounted heat pumps

Wall heat pumps in 2026 in Montréal: five brands compared on their certificates

17 min
Comparison · Wall heat pumps · 12,000 BTU/h

Five names, five certificates: what each one proves on paper

In Montréal quotes, you see names that are less familiar, the ones sometimes called “emerging brands”. Before you rely on one of them, you can check for yourself what it has had certified. Here are five 12,000 BTU/h wall heat pumps sold by AirGreen, side by side and in alphabetical order: their AHRI certificates, their NEEP and ENERGY STAR records, what each manufacturer publishes, and what the electricity costs to heat the same room.

5 models · 12,000 BTU/hA2L refrigerants: R-32 and R-454BENERGY STAR cold climate: all fiveAlphabetical order, no ranking

This article was rebuilt on November 17, 2026. It used to present five brands as a ranked list. It now compares specific models, with their published values. The ACD and TOSOT wall heat pumps offered by AirGreen run on R-410A; our comparisons only include A2L refrigerants, so ELIOS and KINGHOME replace them, at the same capacity.

Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. All five heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. The cards detail the first two in alphabetical order; the table below gives all five, with the same settings.

All five, with the same settings

How this amount is calculated
  1. Heat to supply over the winter. A zone with a heat loss of 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: this is a maximum, since a variable-speed unit slows down when the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one used by Hydro-Québec's calculators. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Behind the name

Who signs each certificate, and since when the model has been on the market

A brand you know little about is not a brand without a trail. Every certified heat pump carries an AHRI number, and the NEEP and ENERGY STAR directories name the company that registered it, the series and the dates. Tap a row to follow it on the timeline.

market date declared to ENERGY STAR ENERGY STAR certification of this model

Two names, the same certified values

The NEEP record of the HAXXAIR V2D and that of the ZEPHYR Series 25 (CB25) show exactly the same values, field by field. The two certificates were registered by two different companies, under two series names. Certificates do not say who builds the unit; they only show that the measured values are identical.

What differs on paper. The registered company (RBL A/C INC. and TTI Climatisation Chauffage), the series name (Hi UNI and HiULTRA), the advertised heating range (−25 °C for HAXXAIR, −30 °C for ZEPHYR) and the published documents.
Why it helps. If you are torn between two names, compare their NEEP records: when every certified value is the same, the difference lies elsewhere, in the documents, the installation and the service.

Sources: NEEP directory (records 383644, 203876, 426104, 387363, 418302) and ENERGY STAR directory, dataset 83eb-xbyy (fields energy_star_partner, series_name, date_available_on_market, date_certified), viewed November 17, 2026.

Overview

All five on the same starting line

Alphabetical order to start. Tap a header to sort it yourself; sorting does not say which unit to choose, it only orders the numbers.

SEER2, HSPF2, −15 °C and coldest point: AHRI certificates read through NEEP. Advertised range: each manufacturer's document. “On the market since”: date declared to the ENERGY STAR directory. The coldest point is not measured at the same temperature for all: compare each capacity with its temperature.

Extreme cold

Below −15 °C, what is published for each

At −15 °C, all five are certified at the same temperature. Colder, each certificate stops at its own point: −25 °C for three of them, −30 °C for two. Between two published values, the page shows the range, without inventing a number in between.

A filled shape: NEEP-certified value. A hollow shape: manufacturer's value, not certified. When both exist at the same temperature, the certificate prevails in comparisons.

Features

What each document names, feature by feature

A feature missing from a document is not necessarily missing from the unit: it is simply not written down. The dotted pill points this out.

Quiet

The published sound of the indoor unit

Each manufacturer publishes its levels its own way: five steps for one, a minimum and a maximum for another, nothing at all on the HAXXAIR sheet consulted.

dB

How to read these numbers. The A-weighted decibel follows the human ear; the lower the number, the quieter. Each dot is a published fan speed.

Why this is not a ranking. None of the documents consulted states the distance or the measurement method, except KINGHOME, which refers to sound pressure. Numbers taken in different ways do not compare directly.

Measurements taken by each manufacturer with its own method: they place a unit within its own range, they do not separate the five.
Installation

On your wall and out to the outdoor unit

Two questions people ask before even choosing: does the indoor unit fit on the planned wall, and does the distance to the outdoor unit stay within what the manufacturer allows?

Is your wall wide enough?

34 in

Scale diagram of each indoor unit's published width. Each installation manual also requires clearances on the sides and to the ceiling: check them before drilling.

Piping length

25 ft

Pre-charged and maximum lengths published by each manufacturer. Beyond the pre-charged length, the installer adds refrigerant according to the manual.

Spec sheets

Each model's sheet, with the source of every line

All five sheets have the same lines, in the same order. Choose a model.

MeasureELIOS EMC R-454BSource
Certificate and directories
AHRI certificate · NEEP recordAHRI 216046614 · NEEP 383644NEEP directory, viewed November 17, 2026
Company registered on the certificateLe Groupe Master“manufacturer” field of the NEEP record; ENERGY STAR: Le Groupe Master Inc.
ENERGY STAR and ENERGY STAR cold climateYes; cold climate: yesENERGY STAR directory, ID 3799005
RefrigerantR-454B · GWP 466 · A2L classNEEP; GWP: IPCC AR4; class: ASHRAE 34
Seasonal ratings, same test conditions
SEER224NEEP 383644
EER213.2NEEP 383644
HSPF2 Region IV / V10.5 / 8.0NEEP 383644
Certified heating
8.3 °C: min. / rated / max. capacity3,800 / 12,000 / 16,000 BTU/hNEEP 383644, 47 °F
−8.3 °C: min. / rated / max. capacity5,200 / 12,000 / 12,800 BTU/hNEEP 383644, 17 °F
−15 °C: min. / rated / max. capacity4,000 / 11,500 / 11,500 BTU/hNEEP 383644, 5 °F
COP at −15 °C, min. / rated / max.1.80 / 1.80 / 1.80NEEP 383644, 5 °F
Coldest point published by NEEP
Test temperature−30 °C (−22 °F)NEEP 383644
Min. / max. capacity at the coldest point2,000 / 5,900 BTU/hNEEP 383644
COP at the coldest point, min. / max.1.07 / 1.25NEEP 383644
Certified cooling
Min. / rated / max. capacity at 35 °C3,600 / 12,000 / 13,500 BTU/hNEEP 383644, 95 °F
Installation and electrical
Advertised heating / cooling range−30 to 24 °C / −30 to 50 °CELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Heated base panYes, 150 WNEEP 383644 (pan heater field)
Maximum piping length82 ftELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Pre-charged lengthFactory charge 1 kg; pre-charged length not statedELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Maximum height difference49.2 ftELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Liquid – gas diameters1/4 – 3/8 inELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Indoor unit W × H × D, weight802 × 295 × 200 mm (31.6 × 11.6 × 7.9 in), 18.96 lbELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Outdoor unit W × H × D, weight805 × 554 × 330 mm (31.7 × 21.8 × 13.0 in), 72.75 lbELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Electrical protection15 A fuseELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Dehumidification1.4 L/hELIOS, EMC sheet (Elios_EMC_202509_FR_V01)
Questions

What people ask us about these five brands

Why does the article no longer rank the brands?

Because a ranking depends on what you value, and that choice is yours. The page puts the same numbers side by side, with their source; the table sorts by whatever matters to you.

Is a brand you see less often less reliable?

No public data measures a brand's reliability in Québec. What you can check: the AHRI certificate, the NEEP and ENERGY STAR listings, the advertised operating range and the manufacturer's documents. All five models on this page have these four elements.

Why are ACD and TOSOT no longer in the article?

The ACD and TOSOT wall heat pumps offered by AirGreen use R-410A. Our comparisons only put A2L-refrigerant units side by side (R-32 or R-454B). ELIOS and KINGHOME, sold by AirGreen in 12,000 BTU/h and A2L, replace them.

Are the HAXXAIR V2D and the ZEPHYR CB25 the same thing?

Their NEEP records show the same certified values, field by field, but they are registered by two different companies, under two series names. The advertised heating ranges also differ: −25 °C for HAXXAIR, −30 °C for ZEPHYR. Certificates do not say who builds what.

What does “coldest certified point” mean?

It is the coldest temperature at which NEEP publishes a capacity for that model: −25 °C for HAXXAIR, MIDEA and ZEPHYR, −30 °C for ELIOS and KINGHOME. A capacity at −25 °C and another at −30 °C do not compare directly.

Are these heat pumps eligible for rebate programs?

Eligibility depends on the program's official list on the date of your application and on your situation. Check the current Hydro-Québec (LogisVert) or Rénoclimat list; programs can change.

All five are on the AirGreen website.

To choose for your room, talk it over with our team: bring the room dimensions, the planned wall, the outdoor location and your current heating.

Sources and documents

Where each number comes from

NEEP, record 383644 (ELIOS EMC R-454B 12,000 BTU)AHRI 216046614 · viewed November 17, 2026 NEEP, record 203876 (HAXXAIR V2D R-454B 12,000 BTU)AHRI 216012011 · viewed November 17, 2026 NEEP, record 426104 (KINGHOME POLARIS R32 12,000 BTU)AHRI 218451122 · viewed November 17, 2026 NEEP, record 387363 (MIDEA MIDEA25 12,000 BTU)AHRI 215471376 · viewed November 17, 2026 NEEP, record 418302 (ZEPHYR Series 25 R-454B 12,000 BTU)AHRI 215414830 · viewed November 17, 2026
ENERGY STAR directory (data.energystar.gov, dataset 83eb-xbyy)ID 3799005, 3723080, 4617797, 3627409 and 3624587 · company, series, market and certification dates, cold climate · viewed November 17, 2026
ELIOS, EMC sheet (French)Elios_EMC_202509_FR_V01 · ranges, dimensions, sound, piping, electrical · viewed November 17, 2026
HAXXAIR, HAHZ-12V2D sheet (haxxair.com)Ranges, dimensions, weights, piping, fuse, dehumidification · read November 16, 2026; the site showed a certificate error on November 17
KINGHOME, POLARIS R32 technical sheetManufacturer documentation distributed by AirGreen, undated · ranges, sound, dimensions, piping, electrical · viewed November 17, 2026 MIDEA, wall heat pump brochure (French)2025-08-20 · p. 12 (MIDEA25), pp. 7 and 8 (features) · viewed November 17, 2026 ZEPHYR, CB25 sheetBRO_2606 · capacities at −8.3, −15, −20 and −25 °C, ranges, sound, dimensions, piping · viewed November 17, 2026 Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, section 2.5 · estimated operating cost Natural Resources Canada, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C), −23.1 °C design · viewed November 17, 2026
IPCC Fourth Assessment Report (AR4) and ASHRAE Standard 34100-year GWP: R-32 675, R-454B 466 · A2L safety class
You made it to the end.Share it with someone it could help.

Leave a comment