Head to head · Wall-mounted heat pumps

2026 comparison: HAXXAIR V2D and ARCOAIRE Deluxe R-454B, what each kilowatt-hour gives you

10 min
Comparison · Wall heat pumps · 12,000 BTU/h · R-454B

For the same kilowatt-hour, how much heat? Two R-454B wall units, figure by figure

A heat pump is paid for twice: at purchase, then every winter on the Hydro-Québec bill. This comparison deals with the second part. The HAXXAIR V2D and the ARCOAIRE Deluxe, two 12,000 BTU R-454B wall units sold by AirGreen, do not have the same certified efficiencies, the same way of modulating, or the same end of range in deep cold. Here is what each one publishes; neither one is put ahead.

R-454B · 12,000 BTU/h2 AHRI certificatesNEEP records 203876 and 389201Data verified November 16, 2026
HAXXAIR V2D R-454B 12,000 BTU (AirGreen image)
HAXXAIR

V2D R-454B

HAHZ-12V2D / HVHZ-12V2D
AHRI 216012011 · NEEP 203876

ZEPHYR Series 25 (CB25) R-454B: same NEEP certified values.

See the product page
ARCOAIRE Deluxe R-454B 12,000 BTU (AirGreen image)
ARCOAIRE

Deluxe R-454B

D5FPHAH12XAK / D5CPRAH12AAK
AHRI 215413213 · NEEP 389201

The MIDEA35: same NEEP heating capacities and COPs; different SEER2, EER2 and HSPF2.

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room reaches the set temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how the unit is used; this amount is not a promise.

What 1 kWh gives

One kilowatt-hour, how much heat?

Electric baseboards turn 1 kWh into 3,412 BTU of heat. A heat pump gives more: the COP says how many times more. Choose a temperature and a step; each square is worth 1,000 BTU, and the bar below shows how far each unit slows down and how far it pushes at that temperature. All values come from the NEEP records.

Electric baseboards: 3,412 BTU per kWh (COP 1)
1,000 BTU of heat per kWhbaseboard referencerated capacity (yellow tick)

Read this before concluding. At the rated step, the HAXXAIR V2D publishes the higher COP at 8.3 °C (3.91 versus 3.59), and the two are level at −8.3 °C (2.40 and 2.41) and at −15 °C (2.00). At maximum, the ARCOAIRE Deluxe pushes further: 17,200 BTU/h versus 13,000 at 8.3 °C, 13,500 versus 11,000 at −15 °C. At minimum, it depends on the temperature: 3,000 versus 4,000 BTU/h at 8.3 °C, 2,000 versus 900 at −15 °C. HSPF2 Region V, used for the cost calculation, sums up the season: 9.0 and 9.3.
Deep cold

Below −15 °C, every published point, with nothing invented in between

Montréal's design temperature is −23.1 °C. HAXXAIR publishes one certified point at −25 °C, the end of its stated range. ARCOAIRE publishes a manufacturer table at 0, −4 and −13 °F, and one certified point at −30 °C.

A bracket is not an estimate: it is the two published values that frame the temperature, each with its source. Manufacturer values are outside the certificate; their COP is calculated from the published kW (BTU/h ÷ 3,412 ÷ kW).

Features

What each manufacturer writes, feature by feature

Only what the manufacturers' documents say. “Not specified” means the documents consulted do not mention it, not that the feature is missing.

Deep cold
  • HAXXAIR V2D R-454B Heating stated down to −25 °C; heating element in the outdoor unit's condensate pan, to prevent ice and help drainage (haxxair.com).
  • ARCOAIRE Deluxe R-454B Heating stated down to −30 °C; 150 W base pan heater declared to NEEP.
Compressor
  • HAXXAIR V2D R-454B Variable-speed (inverter) rotary compressor, according to HAXXAIR.
  • ARCOAIRE Deluxe R-454B Not specified in the documents consulted.
Fan speeds
  • HAXXAIR V2D R-454B Five speeds and an automatic mode; airflow from 253 to 383 cfm.
  • ARCOAIRE Deluxe R-454B Four published sound levels; 558 cfm airflow in the heating table.
Louver direction
  • HAXXAIR V2D R-454B Automatic horizontal and vertical.
  • ARCOAIRE Deluxe R-454B Not specified in the documents consulted.
Maintenance and cleaning
  • HAXXAIR V2D R-454B Washable air filter.
  • ARCOAIRE Deluxe R-454B “Active Clean” function.
Wi-Fi and app
  • HAXXAIR V2D R-454B Not specified in the documents consulted.
  • ARCOAIRE Deluxe R-454B Wi-Fi, according to sheet D5FPHA11-01PD.
Comfort sensors
  • HAXXAIR V2D R-454B Not specified in the documents consulted.
  • ARCOAIRE Deluxe R-454B “Follow Me”, humidity sensor and presence detector.
Operating modes
  • HAXXAIR V2D R-454B Not specified in the documents consulted.
  • ARCOAIRE Deluxe R-454B ECO, Turbo, Silence and Sleep.
Refrigerant leak detection
  • HAXXAIR V2D R-454B Not specified in the documents consulted.
  • ARCOAIRE Deluxe R-454B Leak detection, according to sheet D5FPHA11-01PD.
Dehumidification
  • HAXXAIR V2D R-454B 2.54 US pints/h, about 1.2 L/h.
  • ARCOAIRE Deluxe R-454B 0.5 L/h.
Installation

On the wall: 5 1/2 inches of difference

The HAXXAIR V2D indoor unit is 32 1/2 in wide; the ARCOAIRE Deluxe's is 37.99 in. At the same scale, then the available wall width, then the rest of the installation.

Indoor units, same scale

HAXXAIR V2D R-454B32 1/2 in · 826 mm
Indoor unit HAHZ-12V2D to scale
32 1/2 in · 826 mm
ARCOAIRE Deluxe R-454B37.99 in · 965 mm
Indoor unit D5FPHAH12XAK to scale
37.99 in · 965 mm

Widths according to the manufacturers. Cut-out photos, scaled to their published width.

Is your wall wide enough?

36 in
HAXXAIR V2D R-454B
ARCOAIRE Deluxe R-454B

Width of the unit alone; also allow for the side clearances required by the installation manual of the chosen model.

Installation and unitsHAXXAIRV2D R-454BARCOAIREDeluxe R-454B
Indoor unit W × H × D, weight32 1/2 × 12 × 8 in, 18.7 lbHAHZ-12V2D sheet (haxxair.com).37.99 × 12.56 × 9.41 in, 28.22 lbSheet D5FPHA11-01PD (03/25).
Outdoor unit W × H × D, weight31 7/8 × 23 × 11 in, 70.5 lbHAHZ-12V2D sheet (haxxair.com).35.04 × 26.50 × 13.46 in, 99.65 lbSheet D5CPRA11-01PD (03/25).
Maximum piping length65 ft20 m, combined length.82.02 ftMinimum 9.8 ft.
Pre-charged length25 ftRefrigerant to add beyond that: not stated on the sheet.24.6 ftAdd 0.16 oz/ft beyond that; R-454B charge 2.76 lb.
Maximum height difference49 ft15 m.49.21 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Electrical protectionRecommended fuse 10.2 A208-230 V. Value as published by HAXXAIR.MCA 16 A, MOP 20 A208-230 V.
Stated heating / cooling range−25 to 25 °C / 0 to 46 °C−30 to 24 °C / −30 to 50 °C
Base pan heaterYes, 150 WNEEP record 203876: based on outdoor temperature and during defrost.Yes, 150 WNEEP record 389201: below 3 °C, after 25 minutes of operation, for 5 minutes.
Published indoor sound levelNot stated by the manufacturerNo sound level on the HAHZ-12V2D sheet consulted.41.5 / 33 / 23 / 19 dB(A)Measurement method not stated. Outdoor: 57 dB(A).
Dehumidification2.54 US pints/h (1.2 L/h)0.5 L/hSheet D5FPHA11-01PD.
Certified data

All the certified values, side by side

AHRI certificates and NEEP records, read November 16, 2026.

Certified valueHAXXAIRV2D R-454BARCOAIREDeluxe R-454B
Seasonal efficiencies, same test conditions
SEER223.028.0
EER212.2513.50
HSPF2 Region IV10.012.7
HSPF2 Region V9.09.3
Cooling, same test conditions
35 °C: capacity min. / rated / max.BTU/h3,000 / 12,000 / 13,0003,100 / 12,000 / 16,500
27.8 °C: maximum capacity12,500 BTU/h15,100 BTU/h
Heating, same test conditions
8.3 °C: capacity min. / rated / max.BTU/h3,000 / 12,000 / 13,0004,000 / 12,000 / 17,200
8.3 °C: COP min. / rated / max.4.00 / 3.91 / 3.175.86 / 3.59 / 3.17
−8.3 °C: capacity min. / rated / max.BTU/h2,550 / 10,800 / 12,0001,600 / 11,000 / 14,600
−8.3 °C: COP min. / rated / max.3.74 / 2.40 / 2.511.88 / 2.41 / 2.26
−15 °C: capacity min. / rated / max.BTU/h2,000 / 11,000 / 11,000900 / 13,500 / 13,500
−15 °C: COP min. / rated / max.1.47 / 2.00 / 2.001.15 / 2.00 / 2.00
Coldest point of each NEEP record — different temperatures, no direct comparison
Test temperature−25 °C (−13 °F)−30 °C (−22 °F)
Capacity min. / max.1,000 / 6,100 BTU/h4,100 / 7,500 BTU/h
COP min. / at maximum capacity0.81 / 1.381.14 / 1.29
Certifications and refrigerant
ENERGY STAR / cold climateYes / YesNEEP record 203876; ENERGY STAR directory, ID 3723080Yes / YesNEEP record 389201
AHRI certificate · NEEP record216012011 · 203876215413213 · 389201
RefrigerantR-454B · GWP 466 · A2LGWP per IPCC (AR4); ASHRAE 34 classR-454B · GWP 466 · A2LGWP per IPCC (AR4); ASHRAE 34 class

Bar: span between minimum and maximum capacity; yellow tick: rated capacity. Same scale for both on each row.

Questions

Frequently asked questions

Which one gives more heat for each kWh?

It depends on the temperature and the step. At 8.3 °C and rated capacity, NEEP certifies a COP of 3.91 for the HAXXAIR V2D and 3.59 for the ARCOAIRE Deluxe; at −8.3 °C, 2.40 and 2.41; at −15 °C, 2.00 for both. Over a season, HSPF2 Region V sums these points up: 9.0 and 9.3. The “What 1 kWh gives” module above shows them one by one.

Why doesn't a 12,000 BTU/h unit have the same capacity at −15 °C?

“12,000” is the rated capacity. At −15 °C, NEEP certifies a maximum of 11,000 BTU/h for the HAXXAIR V2D and 13,500 BTU/h for the ARCOAIRE Deluxe. That is the figure that matters for a room with a high heat loss.

What does “minimum capacity” mean?

It is the lowest step at which the unit can run without stopping. At 8.3 °C, NEEP lists 3,000 BTU/h for the HAXXAIR V2D and 4,000 BTU/h for the ARCOAIRE Deluxe; at −15 °C, 2,000 and 900 BTU/h. A low step avoids frequent stops and restarts when demand is low.

Does the HAXXAIR V2D have twins?

The ZEPHYR Series 25 (CB25) R-454B has the same NEEP certified values. Our page ZEPHYR CB22 and CB25 presents it. On the ARCOAIRE side, the MIDEA35 has the same NEEP heating capacities and COPs, but different SEER2, EER2 and HSPF2.

Why R-454B?

Both use R-454B, an A2L-class refrigerant with a GWP of 466 (IPCC, AR4). Our page R-32 or R-454B compares the two refrigerants found in wall heat pumps today.

What size should I choose?

It is chosen from the room's heat loss at −23.1 °C, not the square footage. Our page Sizing a heat pump explains the calculation.

Are these models eligible for LogisVert?

Eligibility depends on Hydro-Québec's list in effect on the day of purchase, which can change. Each model's AHRI certificate number is shown above so you can check it.

What about warranties?

Terms vary by manufacturer, unit registration and dealer; they are not compared here. The warranty documents for the chosen model come with the quote.

Both are on AirGreen's website.

Our estimator comes to your home for free: he measures the room and the wall, looks at where the outdoor unit can go, and you receive a written quote within 24 hours.

Sources

Documents consulted

AHRI certificates 216012011 and 215413213SEER2, EER2, HSPF2, capacities · read from each model's NEEP record
NEEP, cold-climate heat pump list (ashp.neep.org)Records 203876 and 389201, heating, cooling and base pan heater · consulted November 16, 2026
HAXXAIR, HAHZ-12V2D sheet (haxxair.com)Min.-max. capacities, ranges, airflow, piping, dimensions, weights, electrical, features · consulted November 16, 2026
ARCOAIRE, sheet D5CPRA11-01PD03/25 · outdoor unit: heating table at 70 °F, dimensions, piping, charge, electrical, ranges, base pan heater
ARCOAIRE, sheet D5FPHA11-01PD03/25 · indoor unit: dimensions, sound, dehumidification, features
ENERGY STAR directory (data.energystar.gov)ID 3723080
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5
NRCan, HOT2000 climate map, Montréal IntlHeating degree-days and design temperature