See the product pageA heat pump is paid for twice: at purchase, then every winter on the Hydro-Québec bill. This comparison deals with the second part. The HAXXAIR V2D and the ARCOAIRE Deluxe, two 12,000 BTU R-454B wall units sold by AirGreen, do not have the same certified efficiencies, the same way of modulating, or the same end of range in deep cold. Here is what each one publishes; neither one is put ahead.

HAHZ-12V2D / HVHZ-12V2D
AHRI 216012011 · NEEP 203876
ZEPHYR Series 25 (CB25) R-454B: same NEEP certified values.
See the product page
D5FPHAH12XAK / D5CPRAH12AAK
AHRI 215413213 · NEEP 389201
The MIDEA35: same NEEP heating capacities and COPs; different SEER2, EER2 and HSPF2.
See the product pageAirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how the unit is used; this amount is not a promise.
Electric baseboards turn 1 kWh into 3,412 BTU of heat. A heat pump gives more: the COP says how many times more. Choose a temperature and a step; each square is worth 1,000 BTU, and the bar below shows how far each unit slows down and how far it pushes at that temperature. All values come from the NEEP records.
Montréal's design temperature is −23.1 °C. HAXXAIR publishes one certified point at −25 °C, the end of its stated range. ARCOAIRE publishes a manufacturer table at 0, −4 and −13 °F, and one certified point at −30 °C.
A bracket is not an estimate: it is the two published values that frame the temperature, each with its source. Manufacturer values are outside the certificate; their COP is calculated from the published kW (BTU/h ÷ 3,412 ÷ kW).
Only what the manufacturers' documents say. “Not specified” means the documents consulted do not mention it, not that the feature is missing.
The HAXXAIR V2D indoor unit is 32 1/2 in wide; the ARCOAIRE Deluxe's is 37.99 in. At the same scale, then the available wall width, then the rest of the installation.


Widths according to the manufacturers. Cut-out photos, scaled to their published width.


Width of the unit alone; also allow for the side clearances required by the installation manual of the chosen model.
| Installation and units | HAXXAIRV2D R-454B | ARCOAIREDeluxe R-454B |
|---|---|---|
| Indoor unit W × H × D, weight | 32 1/2 × 12 × 8 in, 18.7 lbHAHZ-12V2D sheet (haxxair.com). | 37.99 × 12.56 × 9.41 in, 28.22 lbSheet D5FPHA11-01PD (03/25). |
| Outdoor unit W × H × D, weight | 31 7/8 × 23 × 11 in, 70.5 lbHAHZ-12V2D sheet (haxxair.com). | 35.04 × 26.50 × 13.46 in, 99.65 lbSheet D5CPRA11-01PD (03/25). |
| Maximum piping length | 65 ft20 m, combined length. | 82.02 ftMinimum 9.8 ft. |
| Pre-charged length | 25 ftRefrigerant to add beyond that: not stated on the sheet. | 24.6 ftAdd 0.16 oz/ft beyond that; R-454B charge 2.76 lb. |
| Maximum height difference | 49 ft15 m. | 49.21 ft |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Electrical protection | Recommended fuse 10.2 A208-230 V. Value as published by HAXXAIR. | MCA 16 A, MOP 20 A208-230 V. |
| Stated heating / cooling range | −25 to 25 °C / 0 to 46 °C | −30 to 24 °C / −30 to 50 °C |
| Base pan heater | Yes, 150 WNEEP record 203876: based on outdoor temperature and during defrost. | Yes, 150 WNEEP record 389201: below 3 °C, after 25 minutes of operation, for 5 minutes. |
| Published indoor sound level | Not stated by the manufacturerNo sound level on the HAHZ-12V2D sheet consulted. | 41.5 / 33 / 23 / 19 dB(A)Measurement method not stated. Outdoor: 57 dB(A). |
| Dehumidification | 2.54 US pints/h (1.2 L/h) | 0.5 L/hSheet D5FPHA11-01PD. |
AHRI certificates and NEEP records, read November 16, 2026.
| Certified value | HAXXAIRV2D R-454B | ARCOAIREDeluxe R-454B |
|---|---|---|
| Seasonal efficiencies, same test conditions | ||
| SEER2 | 23.0 | 28.0 |
| EER2 | 12.25 | 13.50 |
| HSPF2 Region IV | 10.0 | 12.7 |
| HSPF2 Region V | 9.0 | 9.3 |
| Cooling, same test conditions | ||
| 35 °C: capacity min. / rated / max.BTU/h | 3,000 / 12,000 / 13,000 | 3,100 / 12,000 / 16,500 |
| 27.8 °C: maximum capacity | 12,500 BTU/h | 15,100 BTU/h |
| Heating, same test conditions | ||
| 8.3 °C: capacity min. / rated / max.BTU/h | 3,000 / 12,000 / 13,000 | 4,000 / 12,000 / 17,200 |
| 8.3 °C: COP min. / rated / max. | 4.00 / 3.91 / 3.17 | 5.86 / 3.59 / 3.17 |
| −8.3 °C: capacity min. / rated / max.BTU/h | 2,550 / 10,800 / 12,000 | 1,600 / 11,000 / 14,600 |
| −8.3 °C: COP min. / rated / max. | 3.74 / 2.40 / 2.51 | 1.88 / 2.41 / 2.26 |
| −15 °C: capacity min. / rated / max.BTU/h | 2,000 / 11,000 / 11,000 | 900 / 13,500 / 13,500 |
| −15 °C: COP min. / rated / max. | 1.47 / 2.00 / 2.00 | 1.15 / 2.00 / 2.00 |
| Coldest point of each NEEP record — different temperatures, no direct comparison | ||
| Test temperature | −25 °C (−13 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 1,000 / 6,100 BTU/h | 4,100 / 7,500 BTU/h |
| COP min. / at maximum capacity | 0.81 / 1.38 | 1.14 / 1.29 |
| Certifications and refrigerant | ||
| ENERGY STAR / cold climate | Yes / YesNEEP record 203876; ENERGY STAR directory, ID 3723080 | Yes / YesNEEP record 389201 |
| AHRI certificate · NEEP record | 216012011 · 203876 | 215413213 · 389201 |
| Refrigerant | R-454B · GWP 466 · A2LGWP per IPCC (AR4); ASHRAE 34 class | R-454B · GWP 466 · A2LGWP per IPCC (AR4); ASHRAE 34 class |
Bar: span between minimum and maximum capacity; yellow tick: rated capacity. Same scale for both on each row.
It depends on the temperature and the step. At 8.3 °C and rated capacity, NEEP certifies a COP of 3.91 for the HAXXAIR V2D and 3.59 for the ARCOAIRE Deluxe; at −8.3 °C, 2.40 and 2.41; at −15 °C, 2.00 for both. Over a season, HSPF2 Region V sums these points up: 9.0 and 9.3. The “What 1 kWh gives” module above shows them one by one.
“12,000” is the rated capacity. At −15 °C, NEEP certifies a maximum of 11,000 BTU/h for the HAXXAIR V2D and 13,500 BTU/h for the ARCOAIRE Deluxe. That is the figure that matters for a room with a high heat loss.
It is the lowest step at which the unit can run without stopping. At 8.3 °C, NEEP lists 3,000 BTU/h for the HAXXAIR V2D and 4,000 BTU/h for the ARCOAIRE Deluxe; at −15 °C, 2,000 and 900 BTU/h. A low step avoids frequent stops and restarts when demand is low.
The ZEPHYR Series 25 (CB25) R-454B has the same NEEP certified values. Our page ZEPHYR CB22 and CB25 presents it. On the ARCOAIRE side, the MIDEA35 has the same NEEP heating capacities and COPs, but different SEER2, EER2 and HSPF2.
Both use R-454B, an A2L-class refrigerant with a GWP of 466 (IPCC, AR4). Our page R-32 or R-454B compares the two refrigerants found in wall heat pumps today.
It is chosen from the room's heat loss at −23.1 °C, not the square footage. Our page Sizing a heat pump explains the calculation.
Eligibility depends on Hydro-Québec's list in effect on the day of purchase, which can change. Each model's AHRI certificate number is shown above so you can check it.
Terms vary by manufacturer, unit registration and dealer; they are not compared here. The warranty documents for the chosen model come with the quote.
Our estimator comes to your home for free: he measures the room and the wall, looks at where the outdoor unit can go, and you receive a written quote within 24 hours.
Data verified November 16, 2026. Certified values: AHRI certificates read from the NEEP records; declared values: manufacturers' documents, cited line by line. Cost: AirGreen estimate, method v1.1 described above.
HAXXAIR, ARCOAIRE, ZEPHYR, MIDEA and the model names are trademarks of their respective owners. The logos identify the products only. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca and we will check it.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.