Climate 5000 MAX PERFORMANCE 18,000 BTU/h
Indoor BMS500-AAU018-1AHWXD
Outdoor BMS500-AAS018-1CSXHD
AHRI 215223286 · NEEP 392017
Montréal’s climate comes down to two numbers that heating calculations use: 4,167 degree-days per winter and a −23.1 °C design temperature. Here are five wall units of the same size offered by AirGreen, with what their certificates and manufacturers publish around those two numbers. No ranking: read the line that matters for your home.

Indoor BMS500-AAU018-1AHWXD
Outdoor BMS500-AAS018-1CSXHD
AHRI 215223286 · NEEP 392017

Indoor ASUH18KZAS
Outdoor AOUH18KZAH1
AHRI 215647921 · NEEP 385842

Indoor GWH18**EXF-D6DN***/I
Outdoor GWH18AVEXF-D6DNA1B/O
AHRI 215386340 · NEEP 389441

Indoor AR18DXDABWKNCV
Outdoor AR18DXDACWKXCV
AHRI 215222786 · NEEP 392031

Indoor AY-XP18ZU1
Outdoor AE-X18ZU1
AHRI 213246053 · NEEP 507396
NEEP certified values, except the last column (manufacturers’ documents). Tap a column heading to sort; the starting order is alphabetical.
| BOSCH | 21.4 | 8.5 | 18,000 BTU/h | −30 °C | 8,000 BTU/h | −30 °C |
|---|---|---|---|---|---|---|
| FUJITSU AIRSTAGE | 25.5 | 10.1 | 25,400 BTU/h | −26.1 °C | 19,110 BTU/h | −26 °C |
| GREE | 27.5 | 8.0 | 18,000 BTU/h | −30 °C | 10,800 BTU/h | −30 °C |
| SAMSUNG | 21.0 | 8.5 | 20,500 BTU/h | −30 °C | 11,000 BTU/h | −30 °C |
| SHARP | 24.0 | 9.0 | 18,000 BTU/h | −27.2 °C | 11,500 BTU/h | −27 °C |
Brands in alphabetical order. The cards are AirGreen product cards; the logos identify the products.
AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. The heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. The top panel shows both ends of the spread: the highest HSPF2 Region V (FUJITSU AIRSTAGE, 10.1) and the lowest (GREE, 8.0); the table below gives all five. The SAMSUNG is certified at 18,500 BTU/h in cooling; the calculation uses 18,000 for all five.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, insulation, settings and use; this amount is not a promise.
None of the five publishes a value at exactly −23.1 °C. For each, the page places the two published values on either side of that temperature, without drawing a line between them. Set your zone’s heat loss: the yellow mark moves, and each line only says whether that need is above, below or between the two published values.
Maximum published values. “Per the manufacturer” values do not come from the certificate and were sometimes measured with another indoor temperature, shown under each line.
Circles: certificates (NEEP). Diamonds: manufacturers’ documents. At each temperature in the table, each unit shows a published value, the range between two published values, or its last value with what the manufacturer says beyond it.
“Not stated” means the document consulted does not mention it. The function may exist elsewhere; ask for the document.
| Item | BOSCHClimate 5000 MAX PERFORMANCE | FUJITSU AIRSTAGEORION XLTH | GREEEXTRÊME R32 | SAMSUNGWindFree Max Heat | SHARPZU1 |
|---|---|---|---|---|---|
| Heating / cooling range stated | −30 to 24 °C / −30 to 50 °C | −26 to 24 °C / −10 to 50 °C | −30 to 30 °C / −29 to 50 °C | −30 to 24 °C / −18 to 46 °C | −27 to 24 °C / −10 to 46 °C |
| Automatic restart after a power failure | Not stated in the document consulted | “Auto-restart function” named | Not stated in the document consulted | Not stated in the document consulted | “Auto Restart” named |
| Wi-Fi | Not stated; wired wall thermostat as accessory | Built-in · AIRSTAGE Mobile | “Wi-Fi connectivity” | Marked in the accessories table | Built-in Wi-Fi |
| Base pan heater Wattage declared to NEEP | 150 W | 150 W | 96 W | 150 W | Not declared to NEEP the brochure describes a “Hot Gas Pipe” against frozen drain holes |
| Dehumidification | 2.2 L/h 4.64 pt/h | 3.6 L/h | 1.8 L/h | Not stated | 2.4 L/h 5.1 pt/h |
Outdoor units: BOSCH 59 dB(A) max., FUJITSU AIRSTAGE 50 dB(A) in heating, GREE 59 dB(A), SAMSUNG 51 dB(A) in cooling, SHARP 52 dB(A).
How to read these figures Each manufacturer measures its own way; the steps and their names change from brand to brand.
Why this is not a ranking A “silent” step at 19.5 dB(A) for one and a “low” step at 30 dB(A) for another do not describe the same airflow.
| Item | BOSCHClimate 5000 MAX PERFORMANCE | FUJITSU AIRSTAGEORION XLTH | GREEEXTRÊME R32 | SAMSUNGWindFree Max Heat | SHARPZU1 |
|---|---|---|---|---|---|
| Indoor unit W × H × D, weight | 38.0 × 12.56 × 9.8 in, 27.3 lb | 45 1/4 × 13 3/8 × 11 in, 36 lb | 43 45/64 × 13 21/32 × 10 1/8 in, 38.6 lb | 41 9/16 × 11 3/4 × 8 7/16 in, 27.3 lb | 41 27/64 × 12 7/16 × 9 51/64 in, 31 lb |
| Outdoor unit W × H × D, weight | 35.04 × 26.5 × 13.46 in, 99.9 lb | 37 × 31 × 12 5/8 in, 117 lb | 37 23/32 × 25 63/64 × 15 53/64 in, 94.8 lb | 37 × 39 5/16 × 13 in, 150.4 lb | 33 15/32 × 27 15/16 × 13 in, 95 lb |
| Max. piping length | 98.4 ft | 164 ft | 131.2 ft | 98 ft | 66 ft |
| Pre-charged length | 24.6 ft | 66 ft | Not stated | Not stated | Not stated |
| Max. height difference | 65.6 ft | 98 ft | 82 ft | 66 ft | 33 ft label not specified in the brochure |
| Liquid – gas diameters | 1/4 – 1/2 in | 3/8 – 5/8 in | 1/4 – 5/8 in | 1/4 – 1/2 in | 1/4 – 3/8 in |
| Electrical protection | MCA 19 A · fuse 20 A | 20 A breaker | MCA 21 A · MOP 25 A | MCA 21 A · MOP 30 A | 25 A fuse MCA not stated |
The original article named GREE, FUJITSU (AIRSTAGE), SHARP, BOSCH and Mitsubishi at different sizes, with a BOSCH central heat pump in the list. The page keeps one wall unit per brand, all at 18,000 BTU/h, to compare at equal size: GREE EXTRÊME R32, FUJITSU AIRSTAGE ORION XLTH, SHARP ZU1, and the BOSCH Climate 5000 MAX PERFORMANCE wall unit instead of the IDS central system. AirGreen does not sell Mitsubishi; the SAMSUNG WindFree Max Heat takes its place. One model’s values do not describe its whole brand.
It is the reference outdoor temperature NRCan (HOT2000) gives for the Montréal Intl station. It is used to estimate a home’s heat loss at the coldest expected time. It is not the lowest temperature ever seen in Montréal.
None of the five manufacturers publishes a value at −23.1 °C. Drawing a line between two published points would be an estimate; the page shows the two published values on either side instead, with their source.
It is worked out room by room from walls, windows, insulation and air leakage. The slider on the page shows how each unit sits for a given value; it does not replace that calculation.
The certificate’s NEEP record gives 8,000 BTU/h max. at −30 °C; the BOSCH submittal gives 9,356 BTU/h with 70 °F indoors. Test conditions differ; the page shows both and follows the certificate in comparisons.
A little. All our comparison pages use the Montréal Intl station so figures compare from one page to the next. Further north, degree-days rise and so does the bill, for the same house.
| Measure | BOSCHClimate 5000 MAX PERFORMANCE | FUJITSU AIRSTAGEORION XLTH | GREEEXTRÊME R32 | SAMSUNGWindFree Max Heat | SHARPZU1 |
|---|---|---|---|---|---|
| Season (AHRI certificate) | |||||
| SEER2 | 21.4 | 25.5 | 27.5 | 21.0 | 24.0 |
| EER2 | 12.5 | 14.0 | 14.3 | 13.2 | 13.0 |
| HSPF2 Region IV / V | 11.0 / 8.5 | 12.5 / 10.1 | 10.0 / 8.0 | 9.7 / 8.5 | 11.0 / 9.0 |
| Heating at 8.3 °C (47 °F) | |||||
| Capacity min. / rated / max. | 11,200 / 18,000 / 19,500 BTU/h | 8,000 / 21,600 / 31,800 BTU/h | 5,000 / 18,600 / 23,000 BTU/h | 7,500 / 20,000 / 25,500 BTU/h | 5,500 / 21,600 / 25,600 BTU/h |
| COP min. / rated / max. | 4.26 / 3.26 / 2.79 | 5.45 / 4.37 / 3.21 | 5.23 / 4.01 / 3.24 | 4.40 / 3.86 / 2.72 | 5.76 / 4.22 / 3.68 |
| Heating at −8.3 °C (17 °F) | |||||
| Capacity min. / rated / max. | 8,000 / 18,000 / 19,200 BTU/h | 5,200 / 13,600 / 27,200 BTU/h | 8,000 / 19,500 / 20,100 BTU/h | 4,100 / 17,500 / 25,000 BTU/h | 7,500 / 22,000 / 22,000 BTU/h |
| COP min. / rated / max. | 3.35 / 2.55 / 2.00 | 3.72 / 3.32 / 2.30 | 2.61 / 1.90 / 1.90 | 3.43 / 2.33 / 1.98 | 3.38 / 2.38 / 2.38 |
| Heating at −15 °C (5 °F) | |||||
| Capacity min. / rated / max. | 5,500 / 18,000 / 18,000 BTU/h | 5,000 / 24,800 / 25,400 BTU/h | 6,800 / 18,000 / 18,000 BTU/h | 6,000 / 14,300 / 20,500 BTU/h | 5,800 / 18,000 / 18,000 BTU/h |
| COP min. / rated / max. | 2.52 / 1.92 / 1.92 | 3.57 / 2.08 / 2.02 | 2.49 / 1.80 / 1.80 | 3.32 / 2.05 / 1.80 | 2.93 / 2.20 / 2.20 |
| Coldest point of each certificate | |||||
| Test temperature | −30 °C (−22 °F) | −26.1 °C (−15 °F) | −30 °C (−22 °F) | −30 °C (−22 °F) | −27.2 °C (−17 °F) |
| Capacity min. / max. | 4,200 / 8,000 BTU/h | 3,700 / 19,110 BTU/h | 5,100 / 10,800 BTU/h | 3,200 / 11,000 BTU/h | 3,200 / 11,500 BTU/h |
| COP min. / max. | 1.76 / 1.20 | 3.10 / 1.65 | 2.14 / 1.23 | 2.53 / 1.34 | 2.04 / 1.88 |
| Certificates | |||||
| Rated capacity at 35 °C | 18,000 BTU/h | 18,000 BTU/h | 18,000 BTU/h | 18,500 BTU/h | 18,000 BTU/h |
| AHRI certificate · NEEP record | 215223286 · 392017 | 215647921 · 385842 | 215386340 · 389441 | 215222786 · 392031 | 213246053 · 507396 |
| ENERGY STAR · cold climate | Yes · yes | Yes · yes | Yes · yes | Yes · yes | Yes · yes |
| Refrigerant | R-454B | R-32 | R-32 | R-32 | R-32 |
higher marks the highest value of the same measure, under the same conditions. It is not a recommendation.
For your home’s heat loss, piping and circuit, talk to AirGreen.
Data verified on November 17, 2026. Certified values come from the NEEP records of the AHRI certificates; the others come from the manufacturers’ documents cited. Documents can change.
BOSCH, FUJITSU AIRSTAGE, GREE, SAMSUNG, WindFree, Max Heat and SHARP are trademarks of their respective owners. Logos only identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.
1 comment
I would like to install a heat pump in a duplex on Laval Street on the Plateau Mont-Royal, with approx 930 square feet per floor. I am interested in the Fujitsu or Mitsubishi models as they are quiet and work in small spaces.