The list · Wall-mounted heat pumps

Wall heat pumps for Greater Montréal’s climate: five 18,000 BTU/h models compared (BOSCH, FUJITSU AIRSTAGE, GREE, SAMSUNG, SHARP)

10 min
Comparison · Wall-mounted heat pumps · 18,000 BTU/h

Five 18,000 BTU/h wall heat pumps and Greater Montréal’s climate, figure by figure

Montréal’s climate comes down to two numbers that heating calculations use: 4,167 degree-days per winter and a −23.1 °C design temperature. Here are five wall units of the same size offered by AirGreen, with what their certificates and manufacturers publish around those two numbers. No ranking: read the line that matters for your home.

5 wall units18,000 BTU/h, A2L refrigerant4,167degree-days, Montréal Intl (NRCan)−23.1 °Cdesign temperature8.0 to 10.1certified HSPF2 Region V
BOSCH Climate 5000 MAX PERFORMANCE 18,000 BTU/h, AirGreen product card
BOSCH

Climate 5000 MAX PERFORMANCE 18,000 BTU/h

Indoor BMS500-AAU018-1AHWXD
Outdoor BMS500-AAS018-1CSXHD
AHRI 215223286 · NEEP 392017

See the product page
FUJITSU AIRSTAGE ORION XLTH 18,000 BTU/h, AirGreen product card
FUJITSU AIRSTAGE

ORION XLTH 18,000 BTU/h

Indoor ASUH18KZAS
Outdoor AOUH18KZAH1
AHRI 215647921 · NEEP 385842

See the product page
GREE EXTRÊME R32 18,000 BTU/h, AirGreen product card
GREE

EXTRÊME R32 18,000 BTU/h

Indoor GWH18**EXF-D6DN***/I
Outdoor GWH18AVEXF-D6DNA1B/O
AHRI 215386340 · NEEP 389441

See the product page
SAMSUNG WindFree Max Heat 18,000 BTU/h, AirGreen product card
SAMSUNG

WindFree Max Heat 18,000 BTU/h

Indoor AR18DXDABWKNCV
Outdoor AR18DXDACWKXCV
AHRI 215222786 · NEEP 392031

See the product page
SHARP ZU1 18,000 BTU/h, AirGreen product card
SHARP

ZU1 18,000 BTU/h

Indoor AY-XP18ZU1
Outdoor AE-X18ZU1
AHRI 213246053 · NEEP 507396

See the product page

Overview

NEEP certified values, except the last column (manufacturers’ documents). Tap a column heading to sort; the starting order is alphabetical.

BOSCH21.48.518,000 BTU/h−30 °C8,000 BTU/h−30 °C
FUJITSU AIRSTAGE25.510.125,400 BTU/h−26.1 °C19,110 BTU/h−26 °C
GREE27.58.018,000 BTU/h−30 °C10,800 BTU/h−30 °C
SAMSUNG21.08.520,500 BTU/h−30 °C11,000 BTU/h−30 °C
SHARP24.09.018,000 BTU/h−27.2 °C11,500 BTU/h−27 °C

Brands in alphabetical order. The cards are AirGreen product cards; the logos identify the products.

Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. The heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. The top panel shows both ends of the spread: the highest HSPF2 Region V (FUJITSU AIRSTAGE, 10.1) and the lowest (GREE, 8.0); the table below gives all five. The SAMSUNG is certified at 18,500 BTU/h in cooling; the calculation uses 18,000 for all five.

How this amount is calculated
  1. Heat to supply. A zone whose heat loss reaches 18,000 BTU/h ( kW) at Montréal’s design temperature (−23.1 °C) needs about kWh of heat per winter, based on the 4,167 degree-days (base 18 °C) of NRCan’s Montréal Intl station (HOT2000).
  2. Electricity, heat pump. Heat × 3.412 ÷ HSPF2 Region V from the AHRI certificate (NEEP record).
  3. Electricity, baseboards. 1 kWh of electricity per kWh of heat.
  4. Cooling. Capacity ÷ SEER2 × hours per day × 60 days ÷ 1,000.
  5. Price. Hydro-Québec Rate D in force April 1, 2026: 7.065¢ up to 40 kWh a day, 11.142¢ above, 9.104¢ on average; × 1.14975 for GST and QST. Access charges are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, insulation, settings and use; this amount is not a promise.

The design-cold day

At −23.1 °C, what each manufacturer publishes on either side

None of the five publishes a value at exactly −23.1 °C. For each, the page places the two published values on either side of that temperature, without drawing a line between them. Set your zone’s heat loss: the yellow mark moves, and each line only says whether that need is above, below or between the two published values.

Maximum published values. “Per the manufacturer” values do not come from the certificate and were sometimes measured with another indoor temperature, shown under each line.

Extreme cold

Every published value from −15 to −30 °C, for all five

Circles: certificates (NEEP). Diamonds: manufacturers’ documents. At each temperature in the table, each unit shows a published value, the range between two published values, or its last value with what the manufacturer says beyond it.

What the documents name

Ranges, restart, Wi-Fi and the outdoor unit’s pan

“Not stated” means the document consulted does not mention it. The function may exist elsewhere; ask for the document.

ItemBOSCHClimate 5000 MAX PERFORMANCEFUJITSU AIRSTAGEORION XLTHGREEEXTRÊME R32SAMSUNGWindFree Max HeatSHARPZU1
Heating / cooling range stated−30 to 24 °C / −30 to 50 °C−26 to 24 °C / −10 to 50 °C−30 to 30 °C / −29 to 50 °C−30 to 24 °C / −18 to 46 °C−27 to 24 °C / −10 to 46 °C
Automatic restart after a power failureNot stated in the document consulted“Auto-restart function” namedNot stated in the document consultedNot stated in the document consulted“Auto Restart” named
Wi-FiNot stated; wired wall thermostat as accessoryBuilt-in · AIRSTAGE Mobile“Wi-Fi connectivity”Marked in the accessories tableBuilt-in Wi-Fi
Base pan heater Wattage declared to NEEP150 W150 W96 W150 WNot declared to NEEP the brochure describes a “Hot Gas Pipe” against frozen drain holes
Dehumidification2.2 L/h 4.64 pt/h3.6 L/h1.8 L/hNot stated2.4 L/h 5.1 pt/h
Sound

Indoor unit sound, per each document

Outdoor units: BOSCH 59 dB(A) max., FUJITSU AIRSTAGE 50 dB(A) in heating, GREE 59 dB(A), SAMSUNG 51 dB(A) in cooling, SHARP 52 dB(A).

dB

How to read these figures Each manufacturer measures its own way; the steps and their names change from brand to brand.

Why this is not a ranking A “silent” step at 19.5 dB(A) for one and a “low” step at 30 dB(A) for another do not describe the same airflow.

Measurements taken by each manufacturer with its own method; different method — not comparable.
Installation

Dimensions, piping and electrical

ItemBOSCHClimate 5000 MAX PERFORMANCEFUJITSU AIRSTAGEORION XLTHGREEEXTRÊME R32SAMSUNGWindFree Max HeatSHARPZU1
Indoor unit W × H × D, weight38.0 × 12.56 × 9.8 in, 27.3 lb45 1/4 × 13 3/8 × 11 in, 36 lb43 45/64 × 13 21/32 × 10 1/8 in, 38.6 lb41 9/16 × 11 3/4 × 8 7/16 in, 27.3 lb41 27/64 × 12 7/16 × 9 51/64 in, 31 lb
Outdoor unit W × H × D, weight35.04 × 26.5 × 13.46 in, 99.9 lb37 × 31 × 12 5/8 in, 117 lb37 23/32 × 25 63/64 × 15 53/64 in, 94.8 lb37 × 39 5/16 × 13 in, 150.4 lb33 15/32 × 27 15/16 × 13 in, 95 lb
Max. piping length98.4 ft164 ft131.2 ft98 ft66 ft
Pre-charged length24.6 ft66 ftNot statedNot statedNot stated
Max. height difference65.6 ft98 ft82 ft66 ft33 ft label not specified in the brochure
Liquid – gas diameters1/4 – 1/2 in3/8 – 5/8 in1/4 – 5/8 in1/4 – 1/2 in1/4 – 3/8 in
Electrical protectionMCA 19 A · fuse 20 A20 A breakerMCA 21 A · MOP 25 AMCA 21 A · MOP 30 A25 A fuse MCA not stated
FAQ

Frequently asked questions

Why these five heat pumps, and why 18,000 BTU/h?

The original article named GREE, FUJITSU (AIRSTAGE), SHARP, BOSCH and Mitsubishi at different sizes, with a BOSCH central heat pump in the list. The page keeps one wall unit per brand, all at 18,000 BTU/h, to compare at equal size: GREE EXTRÊME R32, FUJITSU AIRSTAGE ORION XLTH, SHARP ZU1, and the BOSCH Climate 5000 MAX PERFORMANCE wall unit instead of the IDS central system. AirGreen does not sell Mitsubishi; the SAMSUNG WindFree Max Heat takes its place. One model’s values do not describe its whole brand.

What is the −23.1 °C design temperature?

It is the reference outdoor temperature NRCan (HOT2000) gives for the Montréal Intl station. It is used to estimate a home’s heat loss at the coldest expected time. It is not the lowest temperature ever seen in Montréal.

Why doesn’t the page calculate the exact capacity at −23.1 °C?

None of the five manufacturers publishes a value at −23.1 °C. Drawing a line between two published points would be an estimate; the page shows the two published values on either side instead, with their source.

How do I find out my room’s heat loss?

It is worked out room by room from walls, windows, insulation and air leakage. The slider on the page shows how each unit sits for a given value; it does not replace that calculation.

Why two BOSCH values at −30 °C?

The certificate’s NEEP record gives 8,000 BTU/h max. at −30 °C; the BOSCH submittal gives 9,356 BTU/h with 70 °F indoors. Test conditions differ; the page shows both and follows the certificate in comparisons.

Does the climate change across Greater Montréal?

A little. All our comparison pages use the Montréal Intl station so figures compare from one page to the next. Further north, degree-days rise and so does the bill, for the same house.

Certified data

The values of the five certificates

MeasureBOSCHClimate 5000 MAX PERFORMANCEFUJITSU AIRSTAGEORION XLTHGREEEXTRÊME R32SAMSUNGWindFree Max HeatSHARPZU1
Season (AHRI certificate)
SEER221.425.527.521.024.0
EER212.514.014.313.213.0
HSPF2 Region IV / V11.0 / 8.512.5 / 10.110.0 / 8.09.7 / 8.511.0 / 9.0
Heating at 8.3 °C (47 °F)
Capacity min. / rated / max.11,200 / 18,000 / 19,500 BTU/h8,000 / 21,600 / 31,800 BTU/h5,000 / 18,600 / 23,000 BTU/h7,500 / 20,000 / 25,500 BTU/h5,500 / 21,600 / 25,600 BTU/h
COP min. / rated / max.4.26 / 3.26 / 2.795.45 / 4.37 / 3.215.23 / 4.01 / 3.244.40 / 3.86 / 2.725.76 / 4.22 / 3.68
Heating at −8.3 °C (17 °F)
Capacity min. / rated / max.8,000 / 18,000 / 19,200 BTU/h5,200 / 13,600 / 27,200 BTU/h8,000 / 19,500 / 20,100 BTU/h4,100 / 17,500 / 25,000 BTU/h7,500 / 22,000 / 22,000 BTU/h
COP min. / rated / max.3.35 / 2.55 / 2.003.72 / 3.32 / 2.302.61 / 1.90 / 1.903.43 / 2.33 / 1.983.38 / 2.38 / 2.38
Heating at −15 °C (5 °F)
Capacity min. / rated / max.5,500 / 18,000 / 18,000 BTU/h5,000 / 24,800 / 25,400 BTU/h6,800 / 18,000 / 18,000 BTU/h6,000 / 14,300 / 20,500 BTU/h5,800 / 18,000 / 18,000 BTU/h
COP min. / rated / max.2.52 / 1.92 / 1.923.57 / 2.08 / 2.022.49 / 1.80 / 1.803.32 / 2.05 / 1.802.93 / 2.20 / 2.20
Coldest point of each certificate
Test temperature−30 °C (−22 °F)−26.1 °C (−15 °F)−30 °C (−22 °F)−30 °C (−22 °F)−27.2 °C (−17 °F)
Capacity min. / max.4,200 / 8,000 BTU/h3,700 / 19,110 BTU/h5,100 / 10,800 BTU/h3,200 / 11,000 BTU/h3,200 / 11,500 BTU/h
COP min. / max.1.76 / 1.203.10 / 1.652.14 / 1.232.53 / 1.342.04 / 1.88
Certificates
Rated capacity at 35 °C18,000 BTU/h18,000 BTU/h18,000 BTU/h18,500 BTU/h18,000 BTU/h
AHRI certificate · NEEP record215223286 · 392017215647921 · 385842215386340 · 389441215222786 · 392031213246053 · 507396
ENERGY STAR · cold climateYes · yesYes · yesYes · yesYes · yesYes · yes
RefrigerantR-454BR-32R-32R-32R-32

higher marks the highest value of the same measure, under the same conditions. It is not a recommendation.

All five are on AirGreen’s site.

For your home’s heat loss, piping and circuit, talk to AirGreen.

Sources

Documents consulted

BOSCH, 18K MAX Performance wall submittal, BTC 769208311 B (01.2026)Ranges, capacities at −20/−25/−30 °C (70 °F indoor), dimensions, sound, piping, MCA. Consulted Nov. 17, 2026.
FUJITSU AIRSTAGE, ORION XLTH KZAH brochure, FG8153C rev. 4/2025Ranges, “no lockout”, 127% at −21 °C, functions, dimensions, sound, piping. Consulted Nov. 17, 2026.
GREE Canada, EXTREME R32 brochure, document 062025Ranges, Wi-Fi, dimensions, sound, piping. Consulted Nov. 17, 2026.
SAMSUNG, RAC R32 Technical Data Book (AR**DXD), ver. 1.2, June 27, 2025Ranges, capacity at −20 °C (75 °F indoor), dimensions, sound, piping, MCA/MOP. Consulted Nov. 17, 2026.
SHARP (RBL), ZU/ZHU brochure, AY-XPC18ZU column, undatedRanges, capacities at −20/−25/−27 °C, Auto Restart, Hot Gas Pipe, dimensions, sound. Prints model AY-XPC18ZU; same values as the ZU1 certificate at shared points. Consulted Nov. 17, 2026.
NEEP, Cold Climate Air Source Heat Pump ListRecords 392017, 385842, 389441, 392031 and 507396. Consulted Nov. 17, 2026.
Hydro-Québec, Electricity Rates (April 1, 2026, Rate D, sec. 2.5)7.065¢ and 11.142¢ per kWh. Consulted Nov. 17, 2026.
NRCan, HOT2000 climate map, Montréal Intl4,167 degree-days (base 18 °C), design temperature −23.1 °C. Consulted Nov. 9, 2026.
You made it to the end.Share it with someone it could help.

1 comment

Barbara Hutchison
Barbara Hutchison

I would like to install a heat pump in a duplex on Laval Street on the Plateau Mont-Royal, with approx 930 square feet per floor. I am interested in the Fujitsu or Mitsubishi models as they are quiet and work in small spaces.

Leave a comment