The AirGreen magazineAugust 2026

Wall-mounted heat pumps

9,000 BTU/h wall heat pumps for a single room: BOSCH, FUJITSU AIRSTAGE, GREE and MIDEA compared

Four 9,000 BTU/h wall heat pumps compared for a single room: certified minimum capacity against the room’s need, published extreme-cold values, sound, dimensions and electricity cost, side by side with no ranking.

By the AirGreen team10 min read
Thermopompe murale, comparatif de quatre modèles de 9 000 BTU/h
Comparison · Wall-mounted heat pumps · 9,000 BTU/h

Four 9,000 BTU/h wall units for a single room: what matters when the need is small

Bedroom, office, finished basement: a single room asks for little heat most of the winter, and a lot only on the coldest days. Here are four 9,000 BTU/h wall units offered by AirGreen, with what their certificates publish at both ends: the smallest capacity each can run at continuously, and what remains in extreme cold. No ranking; every figure has its source.

4 wall units9,000 BTU/h, A2L refrigerant2,200 to 5,300BTU/h, certified minimum capacities at 8.3 and −8.3 °C−25 to −30 °Cstated heating limits8.5 to 10.7certified HSPF2 Region V
BOSCH Climate 5000 MAX PERFORMANCE 9,000 BTU/h, AirGreen product card
BOSCH

Climate 5000 MAX PERFORMANCE 9,000 BTU/h

Indoor BMS500-AAU009-1AHWXD
Outdoor BMS500-AAS009-1CSXHD
AHRI 215223278 · NEEP 392025

See the product page
FUJITSU AIRSTAGE ORION XLTH 9,000 BTU/h, AirGreen product card
FUJITSU AIRSTAGE

ORION XLTH 9,000 BTU/h

Indoor ASUH09KZAS
Outdoor AOUH09KZAH1
AHRI 214888800 · NEEP 392123

See the product page
GREE EXTRÊME R32 9,000 BTU/h, AirGreen product card
GREE

EXTRÊME R32 9,000 BTU/h

Indoor GWH09AVDXE-D6DN***/I
Outdoor GWH09AVDXE-D6DNA1B/O
AHRI 215385452 · NEEP 389445

See the product page
MIDEA MIDEA25 9,000 BTU/h, AirGreen product card
MIDEA

MIDEA25 9,000 BTU/h

Indoor MSEHU-H09B-2A
Outdoor MO1ES-H09B-2A
AHRI 215471375 · NEEP 387364

See the product page

Overview

NEEP certified values, except the last column (manufacturers’ documents). Tap a column heading to sort; the starting order is alphabetical.

BOSCH27.49.53,800 BTU/h5,300 BTU/h11,500 BTU/h−30 °C
FUJITSU AIRSTAGE33.110.73,500 BTU/h2,200 BTU/h15,400 BTU/h−26 °C
GREE30.08.52,700 BTU/h2,800 BTU/h11,500 BTU/h−30 °C
MIDEA25.89.24,000 BTU/h5,000 BTU/h8,000 BTU/h−25 °C

Brands in alphabetical order. The cards are AirGreen product cards; the logos identify the products.

Small room, shoulder season

Your room’s need against each unit’s certified range

The NEEP records give, at three temperatures, each unit’s minimum, rated and maximum capacity. Enter your room’s heat loss at −23.1 °C and pick a temperature: the page estimates the room’s need at that moment and places it on each unit’s range. Below the minimum, the unit cannot slow down further; inside the range, it can modulate.

Certified values from the NEEP records; no value between two temperatures is calculated. The room’s need is an estimate: loss at −23.1 °C × (18 − T) ÷ 41.1.

Estimated running cost

What a room’s electricity costs, winter and summer

AirGreen estimate for the same 9,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. The heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. The top panel shows both ends of the spread: the highest HSPF2 Region V (FUJITSU AIRSTAGE, 10.7) and the lowest (GREE, 8.5); the table below gives all four. The GREE is certified at 9,100 BTU/h in cooling; the calculation uses 9,000 for all four.

How this amount is calculated
  1. Heat to supply. A zone whose heat loss reaches 18,000 BTU/h ( kW) at Montréal’s design temperature (−23.1 °C) needs about kWh of heat per winter, based on the 4,167 degree-days (base 18 °C) of NRCan’s Montréal Intl station (HOT2000).
  2. Electricity, heat pump. Heat × 3.412 ÷ HSPF2 Region V from the AHRI certificate (NEEP record).
  3. Electricity, baseboards. 1 kWh of electricity per kWh of heat.
  4. Cooling. Capacity ÷ SEER2 × hours per day × 60 days ÷ 1,000.
  5. Price. Hydro-Québec Rate D in force April 1, 2026: 7.065¢ up to 40 kWh a day, 11.142¢ above, 9.104¢ on average; × 1.14975 for GST and QST. Access charges are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, insulation, settings and use; this amount is not a promise.

Extreme cold

Every published value from −15 to −30 °C, for all four

Circles: certificates (NEEP). Diamonds: manufacturers’ documents. At each temperature in the table, each unit shows a published value, the range between two published values, or its last value with what the manufacturer says beyond it.

What the documents name

Ranges, unoccupied room, Wi-Fi and modes

“Not stated” means the document consulted does not mention it. The function may exist elsewhere; ask for the document.

ItemBOSCHClimate 5000 MAX PERFORMANCEFUJITSU AIRSTAGEORION XLTHGREEEXTRÊME R32MIDEAMIDEA25
Heating / cooling range stated−30 to 24 °C / −30 to 50 °C−26 to 24 °C / −10 to 50 °C−30 to 30 °C / −29 to 50 °C−25 to 24 °C / −25 to 50 °C
Minimum heat for an unoccupied roomNot stated in the document consulted“Minimum Heat Mode” named set point not statedNot stated in the document consultedHeating set point down to 8 °C
Automatic restart after a power failureNot stated in the document consulted“Auto-restart function” namedNot stated in the document consultedNot stated in the document consulted
Wi-FiNot stated; wired wall thermostat as accessoryBuilt-in · AIRSTAGE Mobile“Wi-Fi connectivity”SmartHome app
Modes namedNot stated in the document consultedEconomy, Energy Saving, OccupancySelf-cleaning, G-AISleep, ECO, Silent, Follow Me, Self Clean
Base pan heater Wattage declared to NEEP150 W150 W72 W150 W
Dehumidification0.30 L/h 0.63 pt/h1.1 L/h 2.3 pt/h0.8 L/h 1.69 pt/hNot stated
Sound

Indoor unit sound, per each document

In a bedroom, the indoor unit runs mostly at its lowest steps. Here are all the steps each document publishes, from lowest to highest.

Outdoor units: BOSCH 56 dB(A) max., FUJITSU AIRSTAGE 47 dB(A) in heating, GREE 55 dB(A), MIDEA 52.5 dB(A) at high step.

dB

How to read these figures Each manufacturer measures its own way; the steps and their names change from brand to brand.

Why this is not a ranking A “silent” step for one and a “low” step for another do not describe the same airflow.

Measurements taken by each manufacturer with its own method; different method — not comparable.
Installation

On the room’s wall, then outside

The four indoor units, drawn to the same scale, front and side, with a 40-inch ruler. Dimensions come from the manufacturers’ documents.

ItemBOSCHClimate 5000 MAX PERFORMANCEFUJITSU AIRSTAGEORION XLTHGREEEXTRÊME R32MIDEAMIDEA25
Indoor unit W × H × D, weight33.74 × 11.81 × 9.09 in, 23.4 lb38 9/16 × 11 × 9 7/16 in, 28 lb38 3/16 × 13 21/32 × 10 1/8 in, 33.1 lb31.30 × 11.61 × 8.86 in, 23.4 lb
Outdoor unit W × H × D, weight31.69 × 21.81 × 12.99 in, 72.8 lb31 7/16 × 24 7/8 × 11 7/16 in, 86 lb34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb30.12 × 21.85 × 11.93 in, 62.2 lb
Max. piping length82 ft82 ft131.2 ft82 ft
Pre-charged length24.6 ft49 ftNot stated24.6 ft
Max. height difference49.2 ft66 ft82 ft49.2 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in1/4 – 1/2 in1/4 – 3/8 in
Electrical protectionMCA 15 A · fuse 15 A15 A breakerMCA 11 A · MOP 15 AMCA 12 A · MOP 15 A
FAQ

Frequently asked questions

Why these four heat pumps, and why 9,000 BTU/h?

The earlier article at this address named FUJITSU AIRSTAGE, GREE (twice, under two names), SHARP and MIDEA wall units at different sizes, plus a BOSCH central heat pump. The page keeps one wall unit per brand, all at 9,000 BTU/h, to compare at equal size: BOSCH Climate 5000 MAX PERFORMANCE (instead of the central system), FUJITSU AIRSTAGE ORION XLTH, GREE EXTRÊME R32 and MIDEA MIDEA25. AirGreen does not offer a 9,000 BTU/h SHARP wall unit; the SHARP ZU1 appears in other comparisons, in a larger size. One model’s values do not describe its whole brand.

Why does a “9,000 BTU/h” unit heat at up to 12,000 BTU/h or more at 8.3 °C?

The number in the name is the certified cooling capacity at 35 °C. In heating, each test gives its own values: at 8.3 °C (47 °F), the certified maximum capacity ranges from 13,800 to 23,000 BTU/h depending on the unit. It then drops with the cold; the Extreme cold section shows how far.

Why look at minimum capacity in a small room?

A well-insulated room asks for little heat most of the winter. When that need is smaller than a variable-speed heat pump’s minimum capacity, the unit cannot slow down further and runs in on-off cycles. The certified minimum capacity at each temperature is published in the NEEP records; the Small room section places it next to your room’s need.

How does the page estimate the room’s need at 8.3 °C or −8.3 °C?

You give the room’s heat loss at −23.1 °C, Montréal’s design temperature. The page scales it to the other temperature in proportion to the gap from 18 °C, the degree-day base: need = loss × (18 − T) ÷ 41.1. It is a simple estimate that ignores sun, occupants and appliances; a room-by-room calculation remains the reference.

Can the stated decibels be compared from brand to brand?

No. Each manufacturer measures with its own method, at steps that have neither the same name nor the same airflow. The page shows them side by side so you know what each document states, not to rank them.

Does the GREE really have the same minimum COP at 5 °F and −22 °F?

That is what NEEP record 389445 shows: 2,600 BTU/h and COP 4.23 at minimum at both temperatures. The page reproduces the record as is; the maximum value drops from 11,500 to 7,400 BTU/h.

Is a 9,000 BTU/h unit enough for my room?

Only a heat-loss calculation can tell, because the answer depends on walls, windows, insulation and floor level. With that figure in hand, the page’s slider shows where it sits against each unit’s certified capacities.

Certified data

The values of the four certificates

MeasureBOSCHClimate 5000 MAX PERFORMANCEFUJITSU AIRSTAGEORION XLTHGREEEXTRÊME R32MIDEAMIDEA25
Season (AHRI certificate)
SEER227.433.130.025.8
EER215.418.816.814.9
HSPF2 Region IV / V12.5 / 9.513.3 / 10.711.2 / 8.512.5 / 9.2
Heating at 8.3 °C (47 °F)
Capacity min. / rated / max.3,800 / 12,000 / 16,000 BTU/h3,500 / 12,000 / 23,000 BTU/h2,700 / 10,600 / 16,000 BTU/h4,000 / 10,000 / 13,800 BTU/h
COP min. / rated / max.5.06 / 3.74 / 3.355.13 / 5.33 / 3.085.28 / 4.38 / 3.755.10 / 3.91 / 3.58
Heating at −8.3 °C (17 °F)
Capacity min. / rated / max.5,300 / 12,000 / 12,800 BTU/h2,200 / 7,500 / 17,500 BTU/h2,800 / 12,000 / 13,000 BTU/h5,000 / 8,100 / 9,400 BTU/h
COP min. / rated / max.2.22 / 2.49 / 1.753.39 / 3.60 / 2.494.32 / 2.30 / 2.062.62 / 2.83 / 2.37
Heating at −15 °C (5 °F)
Capacity min. / rated / max.4,100 / 11,500 / 11,500 BTU/h1,900 / 15,400 / 15,400 BTU/h2,600 / 11,500 / 11,500 BTU/h3,700 / 8,000 / 8,000 BTU/h
COP min. / rated / max.1.72 / 1.80 / 1.803.09 / 2.26 / 2.264.23 / 2.11 / 2.112.09 / 2.37 / 2.37
Coldest point of each certificate
Test temperature−30 °C (−22 °F)−26.1 °C (−15 °F)−30 °C (−22 °F)−25 °C (−13 °F)
Capacity min. / max.2,000 / 5,100 BTU/h1,370 / 11,400 BTU/h2,600 / 7,400 BTU/h3,600 / 5,700 BTU/h
COP min. / max.1.17 / 1.112.23 / 1.704.23 / 1.641.65 / 1.64
Certificates
Rated capacity at 35 °C9,000 BTU/h9,000 BTU/h9,100 BTU/h9,000 BTU/h
AHRI certificate · NEEP record215223278 · 392025214888800 · 392123215385452 · 389445215471375 · 387364
ENERGY STAR · cold climateYes · yesYes · yesYes · yesYes · yes
RefrigerantR-454BR-32R-32R-454B

higher marks the highest value of the same measure, under the same conditions. It is not a recommendation.

All four are on AirGreen’s site.

For your room’s heat loss, placement and circuit, talk to AirGreen.

Sources

Documents consulted

BOSCH, 9K MAX Performance wall submittal, BTC 769208305 B (01.2026)Ranges, capacities from 5 to −22 °F (70 °F indoor), dimensions, sound, piping, MCA, accessories. Consulted Nov. 17, 2026.
FUJITSU AIRSTAGE, ORION XLTH KZAH brochure, FG8153C rev. 4/20259,000 column: ranges, 171 / 154 / 127% at −15 / −21 / −26 °C, functions, dimensions, sound, piping. Consulted Nov. 17, 2026.
GREE Canada, EXTREME R32 single-zone brochure, document 0620259,000 column: ranges, functions, dimensions, sound, piping, MCA/MOP. Consulted Nov. 17, 2026.
MIDEA, Ductless Split Systems brochure (MIDEA35/28/25/22), August 20, 2025MIDEA25 9,000 column: ranges, functions, dimensions, sound, piping, MCA/MOP. Consulted Nov. 17, 2026.
NEEP, Cold Climate Air Source Heat Pump ListRecords 392025, 392123, 389445 and 387364. Consulted Nov. 17, 2026.
Hydro-Québec, Electricity Rates (April 1, 2026, Rate D, sec. 2.5)7.065¢ and 11.142¢ per kWh. Consulted Nov. 17, 2026.
NRCan, HOT2000 climate map, Montréal Intl4,167 degree-days (base 18 °C), design temperature −23.1 °C. Consulted Nov. 9, 2026.
You made it to the end.Share it with someone it could help.

Leave a comment