Climate 5000 MAX PERFORMANCE 9,000 BTU/h
Indoor BMS500-AAU009-1AHWXD
Outdoor BMS500-AAS009-1CSXHD
AHRI 215223278 · NEEP 392025
Wall-mounted heat pumps
Four 9,000 BTU/h wall heat pumps compared for a single room: certified minimum capacity against the room’s need, published extreme-cold values, sound, dimensions and electricity cost, side by side with no ranking.
Bedroom, office, finished basement: a single room asks for little heat most of the winter, and a lot only on the coldest days. Here are four 9,000 BTU/h wall units offered by AirGreen, with what their certificates publish at both ends: the smallest capacity each can run at continuously, and what remains in extreme cold. No ranking; every figure has its source.

Indoor BMS500-AAU009-1AHWXD
Outdoor BMS500-AAS009-1CSXHD
AHRI 215223278 · NEEP 392025

Indoor ASUH09KZAS
Outdoor AOUH09KZAH1
AHRI 214888800 · NEEP 392123

Indoor GWH09AVDXE-D6DN***/I
Outdoor GWH09AVDXE-D6DNA1B/O
AHRI 215385452 · NEEP 389445

Indoor MSEHU-H09B-2A
Outdoor MO1ES-H09B-2A
AHRI 215471375 · NEEP 387364
NEEP certified values, except the last column (manufacturers’ documents). Tap a column heading to sort; the starting order is alphabetical.
| BOSCH | 27.4 | 9.5 | 3,800 BTU/h | 5,300 BTU/h | 11,500 BTU/h | −30 °C |
|---|---|---|---|---|---|---|
| FUJITSU AIRSTAGE | 33.1 | 10.7 | 3,500 BTU/h | 2,200 BTU/h | 15,400 BTU/h | −26 °C |
| GREE | 30.0 | 8.5 | 2,700 BTU/h | 2,800 BTU/h | 11,500 BTU/h | −30 °C |
| MIDEA | 25.8 | 9.2 | 4,000 BTU/h | 5,000 BTU/h | 8,000 BTU/h | −25 °C |
Brands in alphabetical order. The cards are AirGreen product cards; the logos identify the products.
The NEEP records give, at three temperatures, each unit’s minimum, rated and maximum capacity. Enter your room’s heat loss at −23.1 °C and pick a temperature: the page estimates the room’s need at that moment and places it on each unit’s range. Below the minimum, the unit cannot slow down further; inside the range, it can modulate.
Certified values from the NEEP records; no value between two temperatures is calculated. The room’s need is an estimate: loss at −23.1 °C × (18 − T) ÷ 41.1.
AirGreen estimate for the same 9,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. The heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. The top panel shows both ends of the spread: the highest HSPF2 Region V (FUJITSU AIRSTAGE, 10.7) and the lowest (GREE, 8.5); the table below gives all four. The GREE is certified at 9,100 BTU/h in cooling; the calculation uses 9,000 for all four.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, insulation, settings and use; this amount is not a promise.
Circles: certificates (NEEP). Diamonds: manufacturers’ documents. At each temperature in the table, each unit shows a published value, the range between two published values, or its last value with what the manufacturer says beyond it.
“Not stated” means the document consulted does not mention it. The function may exist elsewhere; ask for the document.
| Item | BOSCHClimate 5000 MAX PERFORMANCE | FUJITSU AIRSTAGEORION XLTH | GREEEXTRÊME R32 | MIDEAMIDEA25 |
|---|---|---|---|---|
| Heating / cooling range stated | −30 to 24 °C / −30 to 50 °C | −26 to 24 °C / −10 to 50 °C | −30 to 30 °C / −29 to 50 °C | −25 to 24 °C / −25 to 50 °C |
| Minimum heat for an unoccupied room | Not stated in the document consulted | “Minimum Heat Mode” named set point not stated | Not stated in the document consulted | Heating set point down to 8 °C |
| Automatic restart after a power failure | Not stated in the document consulted | “Auto-restart function” named | Not stated in the document consulted | Not stated in the document consulted |
| Wi-Fi | Not stated; wired wall thermostat as accessory | Built-in · AIRSTAGE Mobile | “Wi-Fi connectivity” | SmartHome app |
| Modes named | Not stated in the document consulted | Economy, Energy Saving, Occupancy | Self-cleaning, G-AI | Sleep, ECO, Silent, Follow Me, Self Clean |
| Base pan heater Wattage declared to NEEP | 150 W | 150 W | 72 W | 150 W |
| Dehumidification | 0.30 L/h 0.63 pt/h | 1.1 L/h 2.3 pt/h | 0.8 L/h 1.69 pt/h | Not stated |
In a bedroom, the indoor unit runs mostly at its lowest steps. Here are all the steps each document publishes, from lowest to highest.
Outdoor units: BOSCH 56 dB(A) max., FUJITSU AIRSTAGE 47 dB(A) in heating, GREE 55 dB(A), MIDEA 52.5 dB(A) at high step.
How to read these figures Each manufacturer measures its own way; the steps and their names change from brand to brand.
Why this is not a ranking A “silent” step for one and a “low” step for another do not describe the same airflow.
The four indoor units, drawn to the same scale, front and side, with a 40-inch ruler. Dimensions come from the manufacturers’ documents.
| Item | BOSCHClimate 5000 MAX PERFORMANCE | FUJITSU AIRSTAGEORION XLTH | GREEEXTRÊME R32 | MIDEAMIDEA25 |
|---|---|---|---|---|
| Indoor unit W × H × D, weight | 33.74 × 11.81 × 9.09 in, 23.4 lb | 38 9/16 × 11 × 9 7/16 in, 28 lb | 38 3/16 × 13 21/32 × 10 1/8 in, 33.1 lb | 31.30 × 11.61 × 8.86 in, 23.4 lb |
| Outdoor unit W × H × D, weight | 31.69 × 21.81 × 12.99 in, 72.8 lb | 31 7/16 × 24 7/8 × 11 7/16 in, 86 lb | 34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb | 30.12 × 21.85 × 11.93 in, 62.2 lb |
| Max. piping length | 82 ft | 82 ft | 131.2 ft | 82 ft |
| Pre-charged length | 24.6 ft | 49 ft | Not stated | 24.6 ft |
| Max. height difference | 49.2 ft | 66 ft | 82 ft | 49.2 ft |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in | 1/4 – 1/2 in | 1/4 – 3/8 in |
| Electrical protection | MCA 15 A · fuse 15 A | 15 A breaker | MCA 11 A · MOP 15 A | MCA 12 A · MOP 15 A |
The earlier article at this address named FUJITSU AIRSTAGE, GREE (twice, under two names), SHARP and MIDEA wall units at different sizes, plus a BOSCH central heat pump. The page keeps one wall unit per brand, all at 9,000 BTU/h, to compare at equal size: BOSCH Climate 5000 MAX PERFORMANCE (instead of the central system), FUJITSU AIRSTAGE ORION XLTH, GREE EXTRÊME R32 and MIDEA MIDEA25. AirGreen does not offer a 9,000 BTU/h SHARP wall unit; the SHARP ZU1 appears in other comparisons, in a larger size. One model’s values do not describe its whole brand.
The number in the name is the certified cooling capacity at 35 °C. In heating, each test gives its own values: at 8.3 °C (47 °F), the certified maximum capacity ranges from 13,800 to 23,000 BTU/h depending on the unit. It then drops with the cold; the Extreme cold section shows how far.
A well-insulated room asks for little heat most of the winter. When that need is smaller than a variable-speed heat pump’s minimum capacity, the unit cannot slow down further and runs in on-off cycles. The certified minimum capacity at each temperature is published in the NEEP records; the Small room section places it next to your room’s need.
You give the room’s heat loss at −23.1 °C, Montréal’s design temperature. The page scales it to the other temperature in proportion to the gap from 18 °C, the degree-day base: need = loss × (18 − T) ÷ 41.1. It is a simple estimate that ignores sun, occupants and appliances; a room-by-room calculation remains the reference.
No. Each manufacturer measures with its own method, at steps that have neither the same name nor the same airflow. The page shows them side by side so you know what each document states, not to rank them.
That is what NEEP record 389445 shows: 2,600 BTU/h and COP 4.23 at minimum at both temperatures. The page reproduces the record as is; the maximum value drops from 11,500 to 7,400 BTU/h.
Only a heat-loss calculation can tell, because the answer depends on walls, windows, insulation and floor level. With that figure in hand, the page’s slider shows where it sits against each unit’s certified capacities.
| Measure | BOSCHClimate 5000 MAX PERFORMANCE | FUJITSU AIRSTAGEORION XLTH | GREEEXTRÊME R32 | MIDEAMIDEA25 |
|---|---|---|---|---|
| Season (AHRI certificate) | ||||
| SEER2 | 27.4 | 33.1 | 30.0 | 25.8 |
| EER2 | 15.4 | 18.8 | 16.8 | 14.9 |
| HSPF2 Region IV / V | 12.5 / 9.5 | 13.3 / 10.7 | 11.2 / 8.5 | 12.5 / 9.2 |
| Heating at 8.3 °C (47 °F) | ||||
| Capacity min. / rated / max. | 3,800 / 12,000 / 16,000 BTU/h | 3,500 / 12,000 / 23,000 BTU/h | 2,700 / 10,600 / 16,000 BTU/h | 4,000 / 10,000 / 13,800 BTU/h |
| COP min. / rated / max. | 5.06 / 3.74 / 3.35 | 5.13 / 5.33 / 3.08 | 5.28 / 4.38 / 3.75 | 5.10 / 3.91 / 3.58 |
| Heating at −8.3 °C (17 °F) | ||||
| Capacity min. / rated / max. | 5,300 / 12,000 / 12,800 BTU/h | 2,200 / 7,500 / 17,500 BTU/h | 2,800 / 12,000 / 13,000 BTU/h | 5,000 / 8,100 / 9,400 BTU/h |
| COP min. / rated / max. | 2.22 / 2.49 / 1.75 | 3.39 / 3.60 / 2.49 | 4.32 / 2.30 / 2.06 | 2.62 / 2.83 / 2.37 |
| Heating at −15 °C (5 °F) | ||||
| Capacity min. / rated / max. | 4,100 / 11,500 / 11,500 BTU/h | 1,900 / 15,400 / 15,400 BTU/h | 2,600 / 11,500 / 11,500 BTU/h | 3,700 / 8,000 / 8,000 BTU/h |
| COP min. / rated / max. | 1.72 / 1.80 / 1.80 | 3.09 / 2.26 / 2.26 | 4.23 / 2.11 / 2.11 | 2.09 / 2.37 / 2.37 |
| Coldest point of each certificate | ||||
| Test temperature | −30 °C (−22 °F) | −26.1 °C (−15 °F) | −30 °C (−22 °F) | −25 °C (−13 °F) |
| Capacity min. / max. | 2,000 / 5,100 BTU/h | 1,370 / 11,400 BTU/h | 2,600 / 7,400 BTU/h | 3,600 / 5,700 BTU/h |
| COP min. / max. | 1.17 / 1.11 | 2.23 / 1.70 | 4.23 / 1.64 | 1.65 / 1.64 |
| Certificates | ||||
| Rated capacity at 35 °C | 9,000 BTU/h | 9,000 BTU/h | 9,100 BTU/h | 9,000 BTU/h |
| AHRI certificate · NEEP record | 215223278 · 392025 | 214888800 · 392123 | 215385452 · 389445 | 215471375 · 387364 |
| ENERGY STAR · cold climate | Yes · yes | Yes · yes | Yes · yes | Yes · yes |
| Refrigerant | R-454B | R-32 | R-32 | R-454B |
higher marks the highest value of the same measure, under the same conditions. It is not a recommendation.
For your room’s heat loss, placement and circuit, talk to AirGreen.
Data verified on November 17, 2026. Certified values come from the NEEP records of the AHRI certificates; the others come from the manufacturers’ documents cited. Documents can change.
BOSCH, FUJITSU AIRSTAGE, GREE and MIDEA are trademarks of their respective owners. Logos only identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.