AirGreenCONFORTO

AirGreen × CONFORTO · Ceiling cassettes · 4 models

Clearance above the ceiling, body size, front panel: the brochure’s dimensions, size by size

Authorized CONFORTO dealer · sold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.

The whole CONFORTO space
  1. Home
  2. CONFORTO
  3. Cassettes

CONFORTO Maximum · MHCAS cassettes and MHSZ outdoor units

CONFORTO ceiling cassette: four sizes, and the space it needs above the ceiling

Four MHCAS cassettes from the Maximum series, 9,000 to 24,000 BTU/h, each paired with its MHSZ outdoor unit. A cassette sits in the ceiling: before choosing a size, you need to know whether its body fits. The page checks that from your measurement, and gives the part number of its front panel. NEEP also lists a figure at −30 °C for each of the four.

Updated October 29, 2026 · CONFORTO single-zone and multi-zone brochures (rev. 15/05/26), NEEP, ENERGY STAR and the LogisVert guide

Single-zone brochure · cassette body

What goes above the ceiling, to scale

10.2 in

9,000 to 18,000 · body 22.4 × 22.4 in

8.1 in

24,000 · body 32.7 × 32.7 in

The red line stands for the ceiling. The 24,000 is the widest, but the thinnest.

4MHCAS cassettes in the shop
8.1 to 10.2 inof body height: the 24,000 is the thinnest
4,400 to 20,000BTU/h at −30 °C, maximum speed, per NEEP
22.4 or 32.7 inper side: the square body that goes through the ceiling

This page answers

Can your ceiling take a CONFORTO cassette, which one, and how much heat does it deliver at −30 °C?

The CONFORTO shop · cassettes

All 4 cassettes, right below

MHCAS ceiling cassettes from the Maximum series, sold with their MHSZ outdoor units. Priced by quote.

01 · The ceiling check

The clearance above the ceiling, cassette by cassette

Enter the free space above your ceiling, in inches. Each cassette is compared by the height of its body: 10.2 in from the 9,000 to the 18,000, 8.1 in for the 24,000. The refrigerant lines also run inside that ceiling: that is how a cassette is designed.

Measure from the top of the ceiling to the first obstacle: joist, duct or slab. The body, 22.4 in per side or more, does not fit between joists 16 in apart; with a suspended ceiling or a bulkhead, measure below the joists. The in-home estimate confirms it.

Or try

12 in · 4 of 4 cassettes See the details

Body height and side, panel part numbers: CONFORTO single-zone brochure, rev. 15/05/26.

Free space above the ceiling · 12 in

4 of 4cassettes whose body fits

9,000 to 18,000Body 22.4 × 22.4 in · panel no. 240013566
24,000Body 32.7 × 32.7 in · panel no. 240013567

According to the brochure, the front panel is sold separately from the cassette; it is included in AirGreen’s quote.

What the tool does not check: it compares the body height with your measurement and adds no clearance. The joists, the exact clearance, the drain, the cut-out size and the route of the lines to the outside wall are looked at during the in-home estimate, before the quote.

02 · At −15 and −30 °C

The four cassettes at −8.3, −15 and −30 °C, per NEEP

NEEP lists a figure at −30 °C for each of the four cassettes, at maximum speed. The table also gives the rated heat at −8.3 °C and at −15 °C, SEER2 and the indicative LogisVert amount, pulled live from our product pages.

ModelRated at −8.3 °CAt −15 °CAt −30 °C, max. speedCOP at −30 °CSEER2Indicative LogisVert amountOnly Hydro-Québec confirms the amount granted.
MHCAS09 + MHSZ109AHRI 210605806 · ENERGY STAR 24950739,000 BTU/h10,000 BTU/h4,400 BTU/h1.0220.5no amountoutdoor unit under 12,000 BTU/h in cooling
MHCAS12 + MHSZ112AHRI 210605807 · ENERGY STAR 24950719,900 BTU/h11,300 BTU/h5,800 BTU/h1.1722.3$1,188
MHCAS18 + MHSZ118AHRI 210605808 · ENERGY STAR 249514015,600 BTU/h16,000 BTU/h8,800 BTU/h1.2720.0$1,872
MHCAS24 + MHSZ124AHRI 210605809 · ENERGY STAR 448024621,000 BTU/h25,800 BTU/h20,000 BTU/h1.520.5$2,520

The 24,000 stands out at −30 °C: 20,000 BTU/h, with a COP of 1.5, against 8,800 BTU/h for the 18,000.

NEEP list, AHRI certificates 210605806 to 210605809, read October 28, 2026; values pulled live from our product pages. The 9,000 has no amount: LogisVert guide version 1.10 requires an outdoor unit rated at least 12,000 BTU/h in cooling, and the wall unit page explains that threshold. Only Hydro-Québec confirms the amount granted.

03 · Cassette or wall unit

Cassette or wall unit, 24,000, on the MHSZ124: a figure at −30 °C on one side, none on the other

The MHSZ124 is sold with a ceiling cassette or with a wall unit. NEEP lists a figure at −30 °C for the cassette and none for the wall unit; at −15 °C, the cassette also gives a little more. The wall unit has the better SEER2 and, according to our product pages, the quieter indoor unit.

Cassette 24,000 · MHCAS24Wall unit 24,000 · MHWAL24
Outdoor unitMHSZ124MHSZ124
AHRI certificate210605809210605805
Rated heat at −8.3 °C21,000 BTU/h21,200 BTU/h
Heat at −15 °C25,800 BTU/h25,000 BTU/h
Heat at −30 °C, maximum speed20,000 BTU/hno figure listed
SEER220.521.5
Indoor sound (min. / max.)43 / 48 dB(A)34 / 46 dB(A)
Indicative LogisVert amountOnly Hydro-Québec confirms the amount granted.$2,520$2,544

See the CONFORTO wall heat pumps

Certificates, heat, SEER2, sound and amounts: pulled live from the product pages of both units. NEEP list: a −30 °C figure for AHRI certificate 210605809 (cassette), none for certificate 210605805 (wall unit). Only Hydro-Québec confirms the amount granted.

04 · Did you know

Three details on the cassettes from the single-zone brochure

8.1 in

The biggest cassette is the thinnest

The 24,000’s body is 8.1 in high, against 10.2 in for the 9,000, the 12,000 and the 18,000. It is wider, 32.7 in per side against 22.4 in, but in a shallow ceiling the 24,000 can fit where the other three cannot.

Single-zone brochure, rev. 15/05/26

2 panels

The front panel is sold separately

According to the brochure, the front panel is sold separately from the cassette: part no. 240013566 for the 9,000, the 12,000 and the 18,000, which share the same body, and part no. 240013567 for the 24,000. It is included in AirGreen’s quote.

Single-zone brochure, rev. 15/05/26; quote: AirGreen

16,000

The 18,000 cools at 16,000 BTU/h

According to the brochure, the 18,000 cassette is rated 16,000 BTU/h in cooling, and NEEP lists the same figure. On the same MHSZ118 outdoor unit, NEEP rates the 18,000 wall unit at 18,000 BTU/h.

Single-zone brochure; NEEP list, AHRI certificates 210605808 and 210605804

05 · Questions

Your questions about CONFORTO ceiling cassettes

How much space does a CONFORTO cassette need above the ceiling?

According to the brochure, the body is 10.2 in high for the 9,000, the 12,000 and the 18,000, and 8.1 in for the 24,000. That is the minimum free space to find above the ceiling; the exact clearance, the joists and the route of the lines are checked during the in-home estimate.

Single-zone brochure, rev. 15/05/26
How big an opening does a CONFORTO cassette need in the ceiling?

The body is square: 22.4 in per side for the 9,000 to the 18,000, 32.7 in for the 24,000. The opening has to let it through; the exact cut-out size is confirmed during the in-home estimate.

Single-zone brochure, rev. 15/05/26
Is the front panel included with a CONFORTO cassette?

According to the CONFORTO brochure, the front panel is sold separately from the cassette: part no. 240013566 fits the 9,000, the 12,000 and the 18,000; part no. 240013567, the larger one, fits the 24,000. At AirGreen, it is included in the quote.

Single-zone brochure, rev. 15/05/26; AirGreen
Does the CONFORTO cassette heat at −30 °C?

NEEP lists a figure at −30 °C, at maximum speed, for all four cassettes: 4,400, 5,800, 8,800 and 20,000 BTU/h, from the 9,000 to the 24,000. At −15 °C, NEEP lists 10,000, 11,300, 16,000 and 25,800 BTU/h.

NEEP list, AHRI certificates 210605806 to 210605809
Where do the lines of a CONFORTO ceiling cassette run?

Inside the ceiling: that is how a cassette is designed. The refrigerant lines run above the ceiling to the outside wall, then to the MHSZ outdoor unit. Their sizes, according to our product pages: 1/4 and 3/8 in for the 9,000, 1/4 and 1/2 in for the 12,000 and the 18,000, 3/8 and 5/8 in for the 24,000. The route is looked at during the in-home estimate.

AirGreen product pages
How much LogisVert aid for a CONFORTO cassette?

The indicative amount follows the guide’s rule for an ENERGY STAR cold-climate heat pump, $120 per 1,000 BTU/h of heat at −8 °C (−8.3 °C, 17 °F, in the NEEP list): $1,188 for the 12,000, $1,872 for the 18,000 and $2,520 for the 24,000. The 9,000 has none: its MHSZ109 outdoor unit is under the guide’s 12,000 BTU/h cooling minimum. The aid is for owners. Only Hydro-Québec confirms the amount granted.

LogisVert participation guide, version 1.10; ENERGY STAR
Can a CONFORTO cassette be a head on a multi-zone system?

Yes: the multi-zone brochure also lists cassettes among the heads. The ones on this page are sold with their MHSZ outdoor unit; on a multi-zone system, the heads are chosen during the in-home estimate. The CONFORTO multi-zone page shows the outdoor units.

Multi-zone brochure, rev. 15/05/26
What does a CONFORTO ceiling cassette cost?

Pricing is by quote. The in-home estimate is free, with no commitment.

AirGreen · Air conditioning & heating

The space above your ceiling, measured at your home before the quote

We measure the ceiling, locate the joists and the route of the lines to the outside wall, then give you a quote.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Authorized CONFORTO dealerSold and installed by AirGreen
Free estimateAt home, no commitment
Showroom1370 Joliot-Curie St., Suite 712, Boucherville

Sources checked on October 28, 2026

  • CONFORTO brochure “Thermopompes Maximum, monozones” (single-zone), 8 pages, rev. 15/05/26 (cassette bodies, front panels, cooling of the 18,000): PDF, in French.
  • CONFORTO “Maximum Heat” multi-zone brochure, 8 pages, rev. 15/05/26 (cassettes as heads): PDF.
  • NEEP cold-climate heat pump list, AHRI certificates 210605806, 210605807, 210605808 and 210605809 (cassettes), 210605804 and 210605805 (18,000 and 24,000 wall units), read October 28, 2026. NEEP’s entry for the MHCAS24 files it as “Wall Placement”; the CONFORTO brochure presents it as a ceiling cassette, like the other three.
  • ENERGY STAR Certified Air-Source Heat Pumps (dataset w7cv-9xjt), records 2495073, 2495071, 2495140 and 4480246, cold climate, Canadian market, read October 28, 2026.
  • Hydro-Québec, LogisVert participation guide, residential, version 1.10 (September 15, 2026), heat pump section.
  • AirGreen product pages (certificates, heat, COP, SEER2, sound, lines and LogisVert amounts), read live by this page.

LogisVert amounts are indicative: only Hydro-Québec confirms the amount granted. Priced by quote; free in-home estimate.