CONFORTO Maximum · MHWAL wall units and MHSZ outdoor units
CONFORTO wall heat pump: 9,000 to 24,000 BTU/h, and why the 9,000 has no LogisVert amount
Four MHWAL wall units from the Maximum series, each paired with its MHSZ outdoor unit. For each size, the page gives the heat NEEP lists at −8.3 and −15 °C, and the indicative LogisVert amount. The 9,000 has none: its outdoor unit is rated below the 12,000 BTU/h of cooling that Hydro-Québec’s guide requires.
Heat at −8.3 and −15 °C, size by size, and the 12,000 BTU/h LogisVert threshold
Pick a size. The result shows the wall unit’s range of heat at −8.3 °C, from minimum to maximum speed, then checks one condition of the LogisVert guide: a rated cooling of at least 12,000 BTU/h for the outdoor unit. Below that, there is no amount.
Wall unit size
Reading the result
The band: heat at −8.3 °C, from minimum to maximum speed.
The mark (rated value): the heat at −8.3 °C our indicative amount is based on, at $120 per 1,000 BTU/h (LogisVert guide, version 1.10).
The threshold: 12,000 BTU/h of rated cooling for the outdoor unit, or no amount.
MHWAL12 · 10,000 BTU/h at −8.3 °C · 12,000 BTU/h at −15 °CSee the details
Minimum and maximum at −8.3 °C, rated cooling: NEEP list, entries for AHRI certificates 210605802 to 210605805, read October 28, 2026. Rated heat at −8.3 °C, heat at −15 °C, COP, SEER2, HSPF2, certificates and amounts: pulled live from our product pages. 12,000 BTU/h threshold and the amount rule: LogisVert participation guide, version 1.10 (September 15, 2026). Only Hydro-Québec confirms the amount granted.
MHWAL12 + MHSZ112
10,000BTU/h rated at −8.3 °C, per NEEP
025,000 BTU/h
Range at −8.3 °C, minimum to maximum speed3,268 to 13,112 BTU/h
Heat at −15 °C12,000 BTU/h
COP at −15 °C1.8
SEER2 · HSPF2 (region IV)25.5 · 10.4
Rated cooling, MHSZ11212,000 BTU/h12,000 minimum met
LogisVert, indicative amount$1,200Only Hydro-Québec confirms the amount granted.
AHRI certificate · ENERGY STAR210605803 · no. 2495084
What the tool does not tell you: the size your room needs. That is decided at your home, during the free estimate.
02 · Line sets
CONFORTO wall unit line sets: length, height and refrigerant to add
All four MHSZ outdoor units are factory-charged for 25 ft of line. Beyond that, each extra foot of line takes a little more R-410A, depending on the size. The allowed length and height grow with the unit: the 24,000 reaches twice as far as the 9,000.
Example: 40 ft of line on the 18,000 is 15 ft beyond the factory charge, so 2.4 oz of R-410A to add. On the 24,000, the same 15 ft take 4.8 oz.
Lengths, heights, factory charge and refrigerant to add: CONFORTO single-zone brochure, rev. 15/05/26. Lines, indoor sound and indoor unit size: pulled live from our product pages; the size is shown as listed there, with no axis order given.
03 · Wall unit or cassette
Wall unit or cassette, 12,000: the same MHSZ112 outdoor unit, different NEEP figures
The MHSZ112 is sold with a wall unit or with a ceiling cassette, under two AHRI certificates. NEEP lists more heat at −15 °C and a better SEER2 for the wall unit; only the cassette has a figure at −30 °C.
Wall unit 12,000 · MHWAL12
Cassette 12,000 · MHCAS12
Outdoor unit
MHSZ112
MHSZ112
AHRI certificate
210605803
210605807
Rated heat at −8.3 °C
10,000 BTU/h
9,900 BTU/h
Heat at −15 °C
12,000 BTU/h
11,300 BTU/h
Heat at −30 °C, maximum speed
no figure listed
5,800 BTU/h
SEER2
25.5
22.3
Indoor sound (min. / max.)
24 / 38 dB(A)
32 / 41 dB(A)
Indicative LogisVert amountOnly Hydro-Québec confirms the amount granted.
Certificates, heat, SEER2, sound and amounts: pulled live from the product pages of both units. NEEP list: a −30 °C figure for AHRI certificate 210605807 (cassette), none for certificate 210605803 (wall unit). Only Hydro-Québec confirms the amount granted.
04 · Did you know
Three details on the wall units, from the LogisVert guide, NEEP and the brochure
9,500
At −8.3 °C, the 9,000 heats almost as much as the 12,000
NEEP lists 9,500 BTU/h rated at −8.3 °C for the 9,000 and 10,000 for the 12,000: a 500 BTU/h gap. It is not the heat that keeps the 9,000 out of LogisVert. The guide requires an outdoor unit rated at least 12,000 BTU/h in cooling, and the MHSZ109 is rated 9,000.
NEEP list; LogisVert participation guide, version 1.10
150 W
A heater in the outdoor unit’s base pan
According to NEEP, the MHSZ outdoor unit’s base pan has a 150 W heater. When it has been below 3 °C for 30 seconds and the unit has been running for 25 minutes, the heater runs for 5 minutes.
NEEP list, AHRI certificates 210605802 to 210605805
−15 °C
No NEEP figure at −30 °C for the wall units
NEEP lists the four wall units down to −15 °C, with no test point at −30 °C. The −30 °C in the CONFORTO brochure is the limit of the heating operating range: the unit runs down to it, but no heat output is listed at that temperature.
NEEP list; single-zone brochure, rev. 15/05/26
05 · Questions
Your questions about CONFORTO wall heat pumps
What size of CONFORTO wall heat pump does my room need?
The size of a CONFORTO wall unit is chosen on site, during the free estimate: the room, its windows, its insulation and where the outdoor unit will go all count. What NEEP lists helps compare: at −15 °C, from 10,600 BTU/h for the 9,000 to 25,000 BTU/h for the 24,000.
NEEP list
Why does the CONFORTO 9,000 wall heat pump have no LogisVert amount?
The LogisVert participation guide requires an outdoor unit rated at least 12,000 BTU/h in cooling. The 9,000’s outdoor unit, the MHSZ109, is rated 9,000 BTU/h in cooling according to NEEP. The 12,000 sits right at the minimum: its MHSZ112 is rated 12,000 BTU/h. Only Hydro-Québec confirms the amount granted.
LogisVert participation guide, version 1.10; NEEP list
How much LogisVert aid for a CONFORTO wall heat pump?
The guide sets $120 per 1,000 BTU/h of heat at −8 °C (−8.3 °C, 17 °F, in the NEEP list) for an ENERGY STAR cold-climate heat pump, which all four wall units are. On the 12,000, 10,000 BTU/h give an indicative amount of $1,200; on the 18,000, 15,000 BTU/h give $1,800; on the 24,000, 21,200 BTU/h give $2,544. The aid is for owners. Only Hydro-Québec confirms the amount granted.
LogisVert participation guide, version 1.10; ENERGY STAR; NEEP list
Does the CONFORTO wall heat pump heat at −30 °C?
It runs in heating down to −30 °C, according to the brochure. For heat output, the coldest NEEP figure is at −15 °C: 10,600, 12,000, 18,000 and 25,000 BTU/h, from the 9,000 to the 24,000.
Single-zone brochure; NEEP list
How long can the line set of a CONFORTO wall heat pump be?
The factory charge covers 25 ft of line. The maximum length is 82 ft for the 9,000 and the 12,000, 98 ft for the 18,000 and 164 ft for the 24,000; the maximum height, 32.8, 32.8, 66 and 82 ft. Beyond 25 ft, 0.16 oz of R-410A is added per foot, 0.32 oz on the 24,000.
Single-zone brochure, rev. 15/05/26
How loud is a CONFORTO wall heat pump indoors?
For the indoor unit, our product pages give 24 to 38 dB(A) for the 9,000 and the 12,000, 24 to 46 dB(A) for the 18,000 and 34 to 46 dB(A) for the 24,000, from minimum to maximum.
AirGreen product pages
Can a CONFORTO wall heat pump slow down in mild weather?
Yes, down to a minimum NEEP lists at 8.3 °C (47 °F): 5,070, 3,920, 8,417 and 8,673 BTU/h, from the 9,000 to the 24,000. NEEP also lists a turndown ratio, the maximum heat at −15 °C divided by that minimum: 2.09, 3.06, 2.14 and 2.88. The 12,000 has the widest range; it even goes lower than the 9,000.
NEEP list, AHRI certificates 210605802 to 210605805
What does a CONFORTO wall heat pump cost?
Pricing is by quote. The in-home estimate is free, with no commitment.
AirGreen · Air conditioning & heating
Your CONFORTO wall unit, chosen at your home for the room
We look at the room, where the indoor unit and the outdoor unit will go, then give you a quote.
Authorized CONFORTO dealerSold and installed by AirGreen
Free estimateAt home, no commitment
Showroom1370 Joliot-Curie St., Suite 712, Boucherville
Sources checked on October 28, 2026
CONFORTO brochure “Thermopompes Maximum, monozones” (single-zone), 8 pages, rev. 15/05/26 (lengths and heights, factory charge, refrigerant to add, operating range, optional Wi-Fi): PDF, in French.
NEEP cold-climate heat pump list, AHRI certificates 210605802, 210605803, 210605804 and 210605805 (wall units) and 210605807 (12,000 cassette), read October 28, 2026.
ENERGY STAR Certified Air-Source Heat Pumps (dataset w7cv-9xjt), records 2495124, 2495084, 2495133 and 4480245, cold climate, Canadian market, read October 28, 2026.