ACD · electric furnace · AH224 to AH260 units

ACD electric furnace: the right AH for your FXD central

In the shop, the ACD electric furnace is the AH indoor unit of the ACD FXD central: a high-static-pressure air handler that takes an electric element: 10 or 15 kW (15 kW to be confirmed) for the AH224 and AH236, 20 kW for the AH248 and AH260. Each AH has a single AHRI-certified pairing with an FXD outdoor unit. Pick a size: the “The right AH” tool gives the AH, its outdoor unit, its airflow and the elements listed.

Updated November 5, 2026 · ACD FXD + AH sheet, AHRI certificates, NEEP, ENERGY STAR and the LogisVert guide

ACD FXD + AH sheet

Airflow of the four AHs, in cfm

AH224960
AH2361,000
AH2481,380
AH2601,600

The AH224 and AH236 pair with the FXD-ACD36 outdoor unit; the AH248 and AH260 with the FXD-ACD60 (AHRI certificates 207497901 to 207497904).

4ACD electric furnaces in the shop: the 2- to 5-ton AH units
250 Pahighest published static pressure for all four AHs (1 in. w.c.)
1,600 cfmairflow of the AH260, the highest of the four
24 Vthermostat control, for all four AHs

This page answers

Which AH goes with which FXD outdoor unit, and with which electric element?

The ACD shop · furnaces

The ACD electric furnaces in the shop, right below

AH224, AH236, AH248 and AH260 indoor units, for the 2- to 5-ton ACD FXD centrals. Price on quotation.

01 · The right AH

One AH per size, one FXD outdoor unit per AH

Pick the central’s size. “The right AH” gives the matching AH, its outdoor unit, its published figures, the electric elements listed and how the AH alone compares with the full system.

Central size

AH models, airflow, static pressure, sound, MCA and MOP, line connections and thermostat: ACD FXD + AH sheet. Pairs: AHRI certificates. Elements: elements listed for ACD AH units, 15 kW to be confirmed; no ACD sheet publishes the electrical current with the element.

The pairing

AH236with the FXD-ACD36 · ACD FXD central, 3-ton

The AH236 pairs with the FXD-ACD36 outdoor unit: together they hold AHRI certificate 207497902 and make the 3-ton ACD FXD central.

FXD outdoor unitFXD-ACD36 (also with the AH224)
Airflow1,000 cfm
Static pressure0 to 250 Pa (0 to 1 in. w.c.)
AH sound57 dB(A)
MCA / MOP printed in the 3-ton column (the sheet does not say which unit they apply to, or whether they include the element)24 / 35 A
Electric elements listed10 kW (34,120 BTU/h) or 15 kW (51,180 BTU/h, to be confirmed)
Controlthermostat 24 V
Line connectionsliquid 3/8 in., gas 3/4 in.

AH236 alone

NEEP: no record

ENERGY STAR: no record

LogisVert: not eligible alone

FXD-ACD36 + AH236

NEEP: record 406033

ENERGY STAR: cold climate, record 2415274

LogisVert: the system can be eligible

NEEP and ENERGY STAR records name the outdoor + AH pair. An AH alone has none, and Hydro-Québec excludes replacing a single indoor unit (LogisVert guide 1.10, p. 14).

The four AHs and their FXD outdoor unit
AHOutdoorAirflowElement listed
AH224FXD-ACD36960 cfm10 or 15 kW (15 to be confirmed)
AH236FXD-ACD361,000 cfm10 or 15 kW (15 to be confirmed)
AH248FXD-ACD601,380 cfm20 kW
AH260FXD-ACD601,600 cfm20 kW

What the ACD sheet does not publish for the AHs. Neither the filter size, nor the electrical current with the element, nor the sound test conditions (55 to 61 dB(A)). These points are confirmed at the on-site assessment.

02 · AH alone or system

The AH236 alone, or the FXD-ACD36 + AH236 central?

Same indoor unit, two statuses. The registries and Hydro-Québec look at the pair, not the AH alone.

Electric furnace · 3 tons

AH236 alone

What it isthe central’s indoor unit
Electric element listed10 or 15 kW (15 kW to be confirmed)
AHRI certificateonly with the FXD-ACD36
NEEP recordnone
ENERGY STARno record
LogisVertnot eligible alone

ACD FXD central · 3 tons

FXD-ACD36 + AH236

What it isthe complete central heat pump
Heat pump output35,000 BTU/h at most listed on NEEP at 8.3 °C, 19,100 at −30 °C
AHRI certificate207497902
NEEP record406033
ENERGY STAR2415274, cold climate
LogisVertcan be eligible
The Central page
The four AHs alone and their FXD + AH systems in the registries read on November 5, 2026
AH aloneSystemAHRI certificateNEEP recordENERGY STAR cold climate
AH224: no recordFXD-ACD36 + AH2242074979014060342416733
AH236: no recordFXD-ACD36 + AH2362074979024060332415274
AH248: no recordFXD-ACD60 + AH2482074979034060322415275
AH260: no recordFXD-ACD60 + AH2602074979044060312415276

Hydro-Québec excludes from LogisVert the replacement of a single coil or a single indoor or outdoor unit (guide 1.10, p. 14). NEEP record 406033 and ENERGY STAR record 2415274 belong to the FXD-ACD36 + AH236 pair; the AH236 alone has no record. Only Hydro-Québec confirms the assistance granted.

03 · Did you know

Three details on the AH units of the ACD FXD central

10, 15, 20 kW

The electric element depends on the size

Elements of 10 or 15 kW are listed for the 2- and 3-ton AHs, and 20 kW for the 4- and 5-ton. The 15 kW appears only in the product page text: it is still to be confirmed.

Product page for the elements listed for ACD AH units

960 to 1,600

The airflow rises with the AH

The ACD sheet gives 960 cfm for the AH224, 1,000 for the AH236, 1,380 for the AH248 and 1,600 for the AH260, one value per model.

ACD FXD + AH technical sheet

0 to 250 Pa

A high-static-pressure air handler

The ACD sheet gives all four AHs a static pressure of 0 to 250 Pa (0 to 1 in. w.c.) and files them under “air handler, high static pressure”.

ACD FXD + AH technical sheet

04 · Questions

Your questions about the ACD electric furnace

Which AH goes with which FXD outdoor unit?

The AH224 (2 tons) and AH236 (3 tons) pair with the FXD-ACD36 outdoor unit; the AH248 (4 tons) and AH260 (5 tons) with the FXD-ACD60. Each pair has its own AHRI certificate, from 207497901 to 207497904.

AHRI certificates 207497901 to 207497904
How much heat does the electric element of an ACD AH give?

The elements listed for ACD AH units are 10 or 15 kW (15 kW to be confirmed) for 2 and 3 tons, and 20 kW for 4 and 5 tons, that is 34,120, 51,180 or 68,240 BTU/h at their rated power (1 kW = 3,412 BTU/h). No ACD document we read describes the AH without its FXD outdoor unit, or the electrical current with the element: these points are covered at the on-site assessment.

Product page for the elements listed for ACD AH units; 1 kW = 3,412 BTU/h
Is an ACD AH alone eligible for LogisVert?

No. The LogisVert guide excludes replacing a single indoor unit, and an AH has no NEEP or ENERGY STAR record of its own. It is the FXD + AH pairs that are on those lists, as cold-climate systems. Only Hydro-Québec confirms the assistance granted.

LogisVert guide 1.10, p. 14; NEEP; ENERGY STAR
Why don’t we give the dimensions of an ACD AH?

The ACD FXD + AH sheet prints two sizes (21 ¼ × 48 ¼ × 21 ¼ in. and 24 ¾ × 57 × 21 ¼ in.) and two weights for four models, without saying which goes with which AH. So we do not assign them to any AH: the space for the unit is measured at the on-site assessment.

ACD FXD + AH technical sheet
Which thermostat for an ACD AH?

The ACD FXD + AH sheet gives a 24 V thermostat control.

ACD FXD + AH technical sheet
What does an ACD electric furnace cost?

Pricing for an ACD AH is by quotation, installation included; the electric element is chosen and priced at the on-site assessment. The in-home estimate is free, with no obligation.

AirGreen · Heating and cooling

The right AH, the right element: we choose it at your home

We look at your ducts, where the AH will go and your electrical service, assess your heating needs on site, then send you the quote. The estimate is free.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Sold and installed by AirGreen.Montréal, Laval, Longueuil, the South Shore and the North Shore
Free estimateAt home, no obligation
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville

Sources checked on November 5, 2026

  • ACD FXD + AH technical sheet (FR and EN): AH models, airflow, static pressure, sound levels, MCA and MOP per column, line connections and 24 V thermostat.
  • AHRI certificates 207497901 to 207497904 (FXD + AH, issued March 3, 2022): outdoor and AH pairs.
  • Product page for the electric elements listed for ACD AH units, read on November 5, 2026: 10 and 20 kW offered, 15 kW mentioned in the text only (to be confirmed).
  • NEEP cold-climate heat pump list, records 406031 to 406034 (FXD + AH systems), read on November 5, 2026: ashp.neep.org.
  • ENERGY STAR certified air-source heat pumps (Canadian market), records 2416733, 2415274, 2415275 and 2415276 (FXD + AH systems), read on November 5, 2026: energystar.gov.
  • Hydro-Québec, LogisVert participation guide, residential, version 1.10 (September 15, 2026), p. 14: hydroquebec.com.

Price on quotation; free home estimate.