ACD MPD multi-zone: five outdoor units to compare before you choose the heads

The shop carries five ACD MPD multi-zone outdoor units, from the 2-port MPD 18,000 to the 5-port MPD 42,000. Pick two: our comparison lines up ports, line set, heights, pre-charge, heating, breaker, sound and weight, with the source of every figure.

Updated November 5, 2026 · ACD MPD sheets and manual, AHRI certificates, NEEP, ENERGY STAR and LogisVert

ACD MPD-22 sheet and MPD manual

Total line set published, outdoor unit by outdoor unit

MPD 18,0002 ports20 m
MPD 24,0003 ports60 m
MPD 30,0004 ports70 m
MPD 36,0005 ports75 m
MPD 42,0005 ports75 m

Bars to scale on 75 m, the maximum published for the MPD 36,000 and 42,000. The MPD 18,000 stops at 20 m.

14ACD MPD multi-zone systems in the shop
5MPD outdoor units in the shop, from 18,000 to 42,000 BTU (ACD sheets)
−20 °Cheating limit published for the five MPD outdoor units (ACD sheets)
75 mof line set in total, published for the MPD 36,000 and 42,000 (MPD-22 sheet)

This page answers

Before choosing the heads, which of the five ACD MPD outdoor units fits my number of rooms?

The ACD shop · multi-zone

The ACD MPD multi-zone systems in the shop, right below

Each system pairs one MPD outdoor unit, from 18,000 to 42,000, with its number of heads. Price on quotation.

01 · Two outdoor units side by side

The five MPD outdoor units side by side, two at a time

The outdoor unit sets the number of ports, the line set and the published heights. The heads come next, room by room, on the 2, 3, 4 and 5-zone pages.

Two MPD outdoor units

Outdoor unit A

Outdoor unit B

Ports, maximum breaker and sound: ACD sheets (MPD-22 and the English sheet). Line set, heights and pre-charge: MPD-22 sheet and MPD manual (INS527), p. 14 and 15. Heating at 8.3 °C: AHRI certificates of August 9, 2022; for the MPD 42,000, the nominal value of the MPD-22 sheet, with no test temperature printed. Weight: MPD-22 sheet.

The two outdoor units, row by row

Two MPD outdoor units side by side
RowMPD 24,000MPD24KCH21S-OMPD 30,000MPD30KCH21S-O
PortsACD sheets34
Total line set, at mostMPD-22 sheet and MPD manual60 m70 m
Longest line, at mostMPD-22 sheet and MPD manual20 m25 m
Height, outdoor unit to a headMPD-22 sheet and MPD manual10 m15 m
Height, between two headsMPD-22 sheet and MPD manual10 m7.5 m
Line set covered by the pre-chargeMPD-22 sheet and MPD manual30 m40 m
Heating at 8.3 °C26,000 BTU/hAHRI certificate 20211049730,000 BTU/hAHRI certificate 202110500
Maximum breaker (MOCP)ACD sheets30 A30 A
Outdoor unit soundACD sheets59 dB(A)59 dB(A)
Net weightMPD-22 sheet69 kg66 kg
In the shop2 heads3 heads2 heads3 heads4 heads

From the MPD 24,000 to the MPD 30,000.
Up: ports, from 3 to 4; total line set, from 60 to 70 m; longest line, from 20 to 25 m; height from the outdoor unit to a head, from 10 to 15 m; pre-charge, from 30 to 40 m; heating at 8.3 °C, from 26,000 to 30,000 BTU/h.
Down: height between heads, from 10 to 7.5 m; weight, from 69 to 66 kg.
Same: maximum breaker (30 A); outdoor sound (59 dB(A)).

MPD 30,000: 66 kg per the MPD-22 sheet; the English sheet prints 198.4 lb.

02 · Multi-zone or wall unit

At 24,000 BTU: one MPD outdoor unit or one Commodore23 wall unit

Same size, two uses: several rooms on one outdoor unit, or one large room.

Multi-zone · AHRI certificate 202110497

MPD 24,000

Heads2 or 3
Heating at 8.3 °C26,000 BTU/h
SEER / HSPF21 / 11
Published limit−20 °C
Outdoor sound59 dB(A)
Line set60 m in total, 20 m max. per line
The 3-zone page

Wall unit · AHRI certificate 201863353

Commodore23 24,000

Heads1
Heating at 8.3 °C23,000 BTU/h
SEER / HSPF20 / 10
Published limit−25 °C
Outdoor sound59 dB(A)
Line setup to 25 m
The Commodore23 page

Per the two AHRI certificates, the MPD 24,000 gives more heat at 8.3 °C (26,000 against 23,000 BTU/h), with a SEER of 21 against 20 and an HSPF of 11 against 10. The Commodore23 24,000 has the lower published limit (−25 against −20 °C; the table of the French sheet prints −20 °C) and the same published outdoor sound, 59 dB(A). Its line set can run 25 m to its single head; on the MPD 24,000 each line is limited to 20 m, for 60 m in total. Neither the MPD24KCH21S-O nor the Commodore23 OCD24KCH20S is on the NEEP and ENERGY STAR lists read on November 5, 2026.

03 · Did you know

Three details on the MPD outdoor units, from ACD’s sheets and manuals

40 m

The MPD pre-charge covers 10, 30 or 40 m of line set

The MPD 18,000 comes charged for 10 m of line set, the MPD 24,000 for 30 m, and the MPD 30,000, 36,000 and 42,000 for 40 m. Beyond that, the installer adds 0.2 oz of refrigerant per foot.

ACD MPD-22 sheet, p. 2; MPD manual (INS527), p. 15

1/4 · 3/8

On the outdoor side, each MPD port connects in 1/4 in and 3/8 in

From the MPD 18,000 to the MPD 42,000, the MPD-22 sheet gives the same sizes at the outdoor unit: 1/4 in liquid, 3/8 in gas. On the wall heads, only the gas line grows with size: 1/2 in on the 12,000, 5/8 in on the 18,000 and 24,000.

ACD MPD-22 sheet, p. 2 and 3

150 %

Heads running at once must stay within 150% of the MPD outdoor unit

ACD’s SMD ducted and CCD cassette manuals spell it out: the capacity of the heads running at the same time must not exceed 150% of the MPD outdoor unit’s capacity.

ACD SMD (X62411) and CCD (X62410) manuals, p. 4

04 · Questions

Your questions about ACD MPD multi-zone systems

How many heads can an ACD MPD outdoor unit run?

The MPD 18,000 has 2 ports, the MPD 24,000 has 3, the MPD 30,000 has 4, and the MPD 36,000 and 42,000 have 5. For the MPD 36,000, however, ACD’s sheets publish no five-head combination. The 2-zone and 3-zone pages check your pair or trio of heads against ACD’s table; the 4-zone and 5-zone pages cover heights and line lengths.

ACD MPD-22 and English multi-zone sheets
Which heads connect to an MPD outdoor unit?

Five types: the OCD wall head, from 9,000 to 24,000 BTU, the CCD ceiling cassette, the SMD ducted unit, the CMD floor console and the FCD floor-ceiling unit. The wall heads are the OCD09KCH23S-I, OCD12KCH22S-I, OCD18KCH20S-I and OCD24KCH20S-I. ACD’s combination table reads by size (09, 12, 18, 24), not by type.

ACD MPD-22 sheet, p. 3 and 4
What is the lowest outdoor temperature an MPD outdoor unit heats at?

ACD’s sheets publish a heating limit of −20 °C for the five MPD outdoor units, from the MPD18KCH22S-O to the MPD42KCH21S-O. At AirGreen, backup heat for colder days is planned at the on-site assessment of your heating needs.

ACD MPD-22 sheet; English ACD multi-zone sheet
Why does the MPD 42,000 have no AHRI certificate?

No AHRI certificate is published for the MPD42KCH21S-O, while the MPD 18,000 to 36,000 have theirs (202110494, 202110497, 202110500 and 202110503). For the MPD 42,000, we therefore use the MPD-22 sheet: 45,000 BTU/h of nominal heating (the sheet prints no test temperature), SEER 21 and HSPF 10.2. ACD’s English sheet prints 43,000 BTU/h.

AHRI certificates of the MPD units (August 9, 2022); MPD-22 sheet; English multi-zone sheet
Are ACD MPD multi-zone systems eligible for LogisVert?

No, under the rule in force since November 26, 2025: Hydro-Québec’s LogisVert program covers ENERGY STAR heat pumps only, and none of the five outdoor units sold here (MPD18KCH22S-O to MPD42KCH21S-O) is on the ENERGY STAR list read on November 5, 2026. Only Hydro-Québec confirms the assistance granted.

Hydro-Québec, LogisVert guide 1.10 and the November 26, 2025 list update; ENERGY STAR list (Canadian market), read on November 5, 2026
What does an ACD MPD multi-zone system cost?

Pricing is by quotation, installation included: it depends on which of the five MPD outdoor units is chosen, the number and type of heads, and the line-set route. The home estimate is free and without obligation.

AirGreen · Heating and cooling

Five MPD outdoor units: we pick the right one at your home

We count the rooms, measure the line-set route and the heights to the outdoor unit, assess your heating needs on site, then send you the quote. The estimate is free.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Sold and installed by AirGreen.Montréal, Laval, Longueuil, the South Shore and the North Shore
Free estimateAt home, no obligation
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville

Sources checked on November 5, 2026

  • ACD multi-zone sheet (code MPD-22, 4 pages, 2018): ports, capacities, breaker, sound, weight, pre-charge, line lengths, heights and line sizes. English ACD multi-zone sheet: ports, breaker, sound and the values that differ (MPD 30,000, MPD 42,000).
  • ACD MPD user manual (INS527), p. 14 and 15: line lengths, heights and pre-charge.
  • AHRI certificates of the MPD units: 202110494, 202110497, 202110500 and 202110503, issued August 9, 2022; no certificate published for the MPD42KCH21S-O.
  • ACD SMD ducted unit (X62411) and CCD cassette (X62410) manuals, p. 4: capacity of the heads running at once.
  • AHRI certificate 201863353 of the Commodore23 24,000 (issued March 3, 2022), ACD Commodore23 technical sheet and ACD Commodore23 9,000 to 24,000 manual (INS515): the 24,000 comparison.
  • NEEP cold-climate heat pump list, read on November 5, 2026 by AHRI number: ashp.neep.org; ENERGY STAR list of certified air-source heat pumps (Canadian market), read on November 5, 2026: no record for the MPD18KCH22S-O to MPD42KCH21S-O.
  • Hydro-Québec, LogisVert residential participation guide, version 1.10 (September 15, 2026), and the Hydro-Québec notice on the November 26, 2025 list update (ENERGY STAR only): hydroquebec.com.