The CCD cassette manual describes a drain pump built into the cassette, with a float switch.
ACD CCD cassette manual (X62410), p. 19AirGreen × ACD · Multi-zone · Cassette
A cassette in the ceiling, a pump for the water
Sold and installed by AirGreen. Montréal, Laval, Longueuil, the South Shore and the North Shore.
ACD · CCD ceiling cassette · 3 sizes
The ACD CCD cassette sits in a drop ceiling: only its square grille shows in the room. The 12,000 and 18,000 bodies are 231 mm tall, the 24,000 body 241 mm. A built-in pump lifts the condensate water. Enter the space you have: the “My drop ceiling” tool draws the cassette in your ceiling.
Updated November 5, 2026 · ACD multi-zone sheet (MPD-22) and the CCD cassette manual (X62410)
ACD multi-zone sheet
The two cassette grilles, seen from below
Drawn to scale, sizes in millimetres. Solid line: the grille seen below the ceiling. Dotted line: the body, above it.
This page answers
Will my ACD cassette fit in my ceiling, and where does the condensate water go?
On this page
The ACD shop · cassettes
CCD cassettes of 12,000, 18,000 and 24,000 BTU, paired with an MPD multi-zone outdoor unit. Price on quotation.
01 · My drop ceiling
Pick the size and enter the free space between the drop ceiling and the structure. The drawing and the margin follow your numbers.
Size (BTU)
Nominal capacities, heights, grilles and weights: ACD multi-zone sheet (MPD-22). Pump and lift: CCD cassette manual (X62410), pp. 19 and 20. The margin only compares the body height with your space; at the on-site assessment we also check the structure, the drain, the refrigerant lines and the clearances.
| Size | Cooling / heating | Body height / grille | Net weight |
|---|---|---|---|
| 12,000 cassette | 12,000 / 13,000 BTU/h | 231 / 648 mm | 18 kg |
| 18,000 cassette | 15,354 / 17,000 BTU/h | 231 / 648 mm | 18 kg |
| 24,000 cassette | 22,800 / 27,400 BTU/h | 241 / 950 mm | 28 kg |
Your ceiling, to scale
69 mmleft above the body
White line: the drop ceiling. Dotted line: the underside of the structure. Yellow line: your free space.
✓The 12,000 cassette body fits: 231 mm in 300 mm of space, 69 mm to spare.
02 · Cassette or ducted
Both hide in the ceiling and connect to the same MPD outdoor unit. Same nominal cooling, within 54 BTU/h; the rest differs.
Cassette · CCD18KCHVS-I
Ducted · SMD18KCHVS-I
Per the ACD multi-zone sheet, above the ceiling the 18,000 cassette needs 231 mm of height over 569 × 569 mm; the 18,000 ducted unit, 201 mm over 899 × 615 mm. The cassette lifts its own water (built-in pump, under 280 mm); the ducted unit’s manual keeps its drain lift under 850 mm. The ducted unit gives more heat (18,700 vs. 17,000 BTU/h).
03 · Did you know
Float
The CCD cassette manual describes a drain pump built into the cassette, with a float switch.
ACD CCD cassette manual (X62410), p. 19280 mm
Per the CCD manual, the cassette’s drain lift must stay under 280 mm (11 in.).
ACD CCD cassette manual (X62410), p. 20648 / 950
The 12,000 and 18,000 cassettes share a 648 mm square grille; the 24,000 takes a 950 mm grille.
ACD multi-zone sheet (MPD-22), p. 304 · Questions
The ACD cassette body is 231 mm tall in the 12,000 and 18,000 sizes, and 241 mm in the 24,000. That is the body alone; the installation clearances are checked on site. Below the ceiling, only the grille shows: 648 mm square and 48 mm thick, or 950 mm and 58 mm for the 24,000.
ACD multi-zone sheet (MPD-22), p. 3; ACD CCD cassette manual (X62410), p. 20The CCD cassette manual describes a built-in drain pump with a float switch. It lifts the water to the drain, with a lift under 280 mm (11 in.). The drain route is checked at the on-site assessment.
ACD CCD cassette manual (X62410), pp. 19 and 20The ACD cassette starts at 12,000 BTU: on the MPD 18,000, it only fits in the 09 + 12 pair. The 18,000 cassette, still on the 648 mm grille, needs at least an MPD 24,000; the 24,000, the only one with a 950 mm grille, an MPD 36,000 or 42,000 (the Multi-zone page compares them). In the ordering example of the MPD-22 sheet, the 18,000 cassette is the one that completes a five-head MPD 42,000.
Combinations printed in both ACD multi-zone sheetsThe ACD sheet prints 42 / 46 dB(A) for the 12,000 and 18,000 cassettes, and 35 / 39 dB(A) for the 24,000, even though it moves more air (500 to 694 cfm vs. 265 to 353). Both multi-zone sheets give the same values.
ACD multi-zone sheets (MPD-22, p. 3, and English edition)No, under the rules in force since November 26, 2025, neither alone nor with its MPD outdoor unit. Hydro-Québec excludes replacing a single indoor unit (guide 1.10, p. 14) and accepts ENERGY STAR heat pumps only; the MPD outdoor units AirGreen sells are not on the ENERGY STAR list read on November 5, 2026.
LogisVert guide 1.10, pp. 14 and 15; Hydro-Québec notice on the November 26, 2025 list update (ENERGY STAR only); ENERGY STAR listPricing for a 12,000 to 24,000 BTU CCD cassette is by quotation, installation included, with the MPD outdoor unit that runs it. The in-home estimate is free, with no obligation; we measure the space above your ceiling during the visit.
AirGreen · Heating and cooling
We measure the space above the drop ceiling, trace the drain and the refrigerant line route to the MPD outdoor unit, assess your heating needs on site, then send you the quote. The estimate is free.
Price on quotation; free home estimate.