ACD three-head heat pump: can the third room be a large one?

Four MPD outdoor units take three heads, from the MPD 24,000 to the MPD 42,000. Pick the size of each head: the tool reads ACD’s combination table and tells you which outdoor units ACD lists your trio for, and why a 24,000 head changes everything.

Updated November 5, 2026 · ACD MPD sheets and manual, AHRI certificates

ACD MPD-22 and English multi-zone sheets

Head trios published, outdoor unit by outdoor unit

MPD 24,0003 ports5
MPD 30,0004 ports7
MPD 36,0005 ports14
MPD 42,0005 ports15

Trios printed in both ACD sheets. The MPD 18,000 has only two ports.

4three-head ACD MPD systems in the shop, from the MPD 24,000 to the MPD 42,000
5trios published for the MPD 24,000, from 09 + 09 + 09 to 12 + 12 + 12 (ACD sheets)
15trios published for the MPD 42,000, the longest three-head list (ACD sheets)
25 mmax. per line on the MPD 30,000, 36,000 and 42,000, against 20 m on the MPD 24,000 (MPD-22 sheet)

This page answers

With three ACD heads, can my third room have a large head?

The ACD shop · 3 zones

The three-head ACD MPD systems, right below

Four outdoor units, from the MPD 24,000 to the MPD 42,000, each sold with three heads. Price on quotation.

01 · The 24,000 head

Three heads: which MPD outdoor units have my trio in their table?

Pick the three sizes. Add a 24,000 head and watch the list shrink to the MPD 36,000 and 42,000.

My three rooms

Head 1 (BTU)

Head 2 (BTU)

Head 3 (BTU)

Combinations: ACD’s table, trios printed in both the MPD-22 sheet and the English multi-zone sheet; the order of the heads does not matter. The table reads by size: a 09 + 09 + 18 trio stands for two 9,000 heads and one 18,000 BTU/h head, whatever their type. Line set: MPD-22 sheet and MPD manual (INS527), p. 14. Heating: AHRI certificates of August 9, 2022, at 8.3 °C; for the MPD 42,000, the nominal value of the MPD-22 sheet, with no test temperature printed (the same sheet gives 42,500 BTU/h for the MPD 36,000).

The four outdoor units for this trio

The four MPD outdoor units with three ports or more for this trio
Outdoor unitTrio publishedPorts leftLine setHeating at 8.3 °C
MPD 24,000MPD24KCH21S-OProduct pageyes060 m in total20 m max. per line26,000 BTU/hAHRI certificate 202110497
MPD 30,000MPD30KCH21S-OProduct pageyes170 m in total25 m max. per line30,000 BTU/hAHRI certificate 202110500
MPD 36,000MPD36KCH21S-OProduct pageyes275 m in total25 m max. per line36,000 BTU/hAHRI certificate 202110503
MPD 42,000MPD42KCH21S-OProduct pageyes275 m in total25 m max. per line45,000 BTU/hnominal per the MPD-22 sheet, no certificate

09 + 09 + 18: the MPD 24,000 is the smallest outdoor unit ACD lists this trio for, with 60 m of line set in total and 20 m max. per line.

02 · The fourth head

A fourth head on the MPD 30,000: from 7 trios down to 3 combinations

Same outdoor unit, same AHRI certificate 202110500: the fourth head shortens the list.

3 heads · AHRI certificate 202110500

MPD 30,000, 3 heads

Combinations published7 trios, from 09 + 09 + 09 to 12 + 12 + 18
Ports left1
Largest head published18,000
Line set70 m in total, 25 m max. per line
Heating at 8.3 °C30,000 BTU/h

4 heads · AHRI certificate 202110500

MPD 30,000, 4 heads

Combinations published3, from 09 + 09 + 09 + 09 to 09 + 09 + 12 + 12
Ports left0
Largest head published12,000
Line set70 m in total, 25 m max. per line
Heating at 8.3 °C30,000 BTU/h
The 4-zone page

With three heads, the MPD 30,000 has 7 published trios and takes an 18,000 head. With four, the MPD-22 sheet gives it only 3 combinations, all with 9,000 and 12,000 heads; ACD’s English sheet adds 09 + 09 + 09 + 18, which the MPD-22 sheet does not print.

03 · Did you know

Three details on three-head ACD systems, from the sheets and the manual

30 m

The MPD 24,000 is charged for 30 m of line set

The MPD 24,000 pre-charge covers 30 m: three 10 m lines already reach it. Beyond that, up to the 60 m published, the installer adds 0.2 oz of refrigerant per foot.

ACD MPD-22 sheet, p. 2; MPD manual (INS527), p. 15

24,000

A 24,000 head in a trio calls for the MPD 36,000 or 42,000

The trios published for the MPD 24,000 and 30,000 stop at 18,000 heads. For 09 + 09 + 24, 09 + 12 + 24 or 12 + 12 + 24, you need an MPD 36,000 or 42,000.

ACD MPD-22 sheet, p. 4; English ACD multi-zone sheet

12 + 18 + 18

One MPD 36,000 trio the MPD 42,000 does not have

Both ACD sheets publish the 12 + 18 + 18 trio for the MPD 36,000, but not for the larger MPD 42,000. The other way round, only the MPD 42,000 has 09 + 24 + 24 and 18 + 18 + 24.

ACD MPD-22 sheet, p. 4; English ACD multi-zone sheet

04 · Questions

Your questions about three-head ACD heat pumps

Which ACD outdoor unit for three rooms?

The MPD 24,000 is the smallest three-port MPD outdoor unit, with 5 published trios. The MPD 30,000 has 7 and adds 09 + 12 + 18 and 12 + 12 + 18; the MPD 36,000 and 42,000 have 14 and 15, and are the only ones to take a 24,000 head. The choice is made at the on-site assessment of your heating needs.

ACD MPD-22 and English multi-zone sheets
Can a 24,000 head go in a three-head system?

Yes, on an MPD 36,000 or 42,000: ACD lists 09 + 09 + 24, 09 + 12 + 24, 09 + 18 + 24 and 12 + 12 + 24 for both. No MPD outdoor unit has 12 + 18 + 24, or three 24,000 heads, in ACD’s sheets.

ACD MPD-22 sheet, p. 4; English ACD multi-zone sheet
How much line set for three heads?

On the MPD 24,000: 60 m in total, so 20 m on average for three lines, and 20 m at most for the longest. On the MPD 30,000 to 42,000: 70 or 75 m in total, 25 m max. per line.

ACD MPD-22 sheet, p. 2; MPD manual (INS527), p. 14
Three 12,000 heads: which MPD outdoor unit?

All four outdoor units with three ports or more have 12 + 12 + 12 on their list. The MPD 24,000 is therefore the smallest that takes it; it is also, with 09 + 09 + 18, one of the two largest trios on its list (36,000 BTU/h of heads).

ACD MPD-22 and English multi-zone sheets
What does a three-head ACD heat pump cost?

Pricing is by quotation, installation included: it depends on the MPD outdoor unit, the type and size of the three heads and the route of the three lines. The home estimate is free and without obligation.

AirGreen · Heating and cooling

Three rooms, one MPD outdoor unit: we choose it at your home

We look at the three rooms and the line-set route, assess your heating needs on site, then send you the quote. The estimate is free.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Sold and installed by AirGreen.Montréal, Laval, Longueuil, the South Shore and the North Shore
Free estimateAt home, no obligation
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville

Sources checked on November 5, 2026

  • ACD multi-zone sheet (code MPD-22, 4 pages, 2018) and the English ACD multi-zone sheet: ports, combination table, line lengths, pre-charge.
  • ACD MPD user manual (INS527), p. 14 and 15: line lengths and pre-charge.
  • AHRI certificates of the MPD units: 202110497, 202110500 and 202110503, issued August 9, 2022; no certificate published for the MPD42KCH21S-O.

Price on quotation; free home estimate.