ACD wall heat pump: three series, three published limits

ACD offers three wall series. Their sheets publish a heating limit of −20 °C for the Éclypse, −25 °C for the Commodore23 from 9,000 to 24,000 and −30 °C for the Révolution. Pick a size: the three series line up on the same rows, each figure with its source.

Updated November 5, 2026 · ACD sheets and manuals, AHRI certificates, NEEP, ENERGY STAR and the LogisVert guide

ACD sheets

Published heating limit, series by series

Éclypse−20 °C
Commodore23−25 °C
Révolution−30 °C

Sizes from 9,000 to 24,000 BTU. The Commodore23 also comes in 30,000 and 36,000: their manual gives −20 °C.

14ACD wall heat pumps in the shop
3series: Éclypse, Commodore23 and Révolution
−30 °Clowest published heating limit, the Révolution’s
36,000BTU, the largest ACD wall size, Commodore23 only

This page answers

At my size, which of the three ACD wall series fits my winter and my wall?

The ACD shop · wall units

The ACD wall units in the shop, right below

Éclypse, Commodore23 and Révolution, from 9,000 to 36,000 BTU. Price on quotation.

01 · Same size, three series

At the same size, what changes from one ACD wall unit to the next

The rows are the same for the three series. A row with no figure means the source does not publish it, not that the value is zero.

Size (BTU)

Nominal heating: AHRI certificates (Commodore23) and NEEP records (Révolution 12,000 to 24,000), at 8.3 °C; the Éclypse and Révolution 9,000 sheets do not print the conditions. SEER and HSPF: ACD sheet for the Éclypse and Révolution, AHRI certificate (2017 standard) for the Commodore23; SEER2 and HSPF2: NEEP list. Width: ACD sheets. Line length: ACD manuals (for the Révolution the sheet claims more; we keep the manual).

The three series at the same size

Éclypse

Published heating limit−20 °C
Nominal heating24,000 BTU/hACD sheet, conditions not printed
SEER / HSPF19 / 10ACD sheet
Indoor unit, lowest sound level47 dB(A)
Indoor unit, width42.4 in (108 cm)ACD sheet
Longest refrigerant line25 m
Wi-Fioptional key
NEEP / ENERGY STARno / nono record
LogisVertnot eligibleno ENERGY STAR record

Commodore23

Published heating limit−25 °C
Nominal heating23,000 BTU/hAHRI certificate 201863353, at 8.3 °C
SEER / HSPF20 / 10AHRI certificate
Indoor unit, lowest sound level36 dB(A)
Indoor unit, width42.4 in (108 cm)ACD sheet
Longest refrigerant line25 m
Wi-Fioptional key
NEEP / ENERGY STARno / nono record
LogisVertnot eligibleno ENERGY STAR record

Révolution

Published heating limit−30 °C
Nominal heating24,000 BTU/hNEEP 406804, at 8.3 °C
SEER / HSPF21.5 / 12ACD sheet · SEER2 21.5 / HSPF2 9.5 listed on NEEP
Indoor unit, lowest sound level34 dB(A)
Indoor unit, width43.3 in (110 cm)ACD sheet
Longest refrigerant line25 m
Wi-Fibuilt in
NEEP / ENERGY STARyes / yesNEEP 406804 · ENERGY STAR 2415080
LogisVert$2,400indicative amount

Published heating limit

−20 °C−25 °C−30 °C

Nominal heating

24,000 BTU/hACD sheet, conditions not printed23,000 BTU/hAHRI certificate 201863353, at 8.3 °C24,000 BTU/hNEEP 406804, at 8.3 °C

SEER / HSPF

19 / 10ACD sheet20 / 10AHRI certificate21.5 / 12ACD sheet · SEER2 21.5 / HSPF2 9.5 listed on NEEP

Indoor unit, lowest sound level

47 dB(A)36 dB(A)34 dB(A)

Indoor unit, width

42.4 in (108 cm)ACD sheet42.4 in (108 cm)ACD sheet43.3 in (110 cm)ACD sheet

Longest refrigerant line

25 m25 m25 m

Wi-Fi

optional keyoptional keybuilt in

NEEP / ENERGY STAR

no / nono recordno / nono recordyes / yesNEEP 406804 · ENERGY STAR 2415080

LogisVert

not eligibleno ENERGY STAR recordnot eligibleno ENERGY STAR record$2,400indicative amount

At 24,000 BTU: lowest published limit, Révolution (−30 °C); highest nominal heating, Éclypse and Révolution (24,000 BTU/h); quietest indoor unit, Révolution (34 dB(A)); narrowest, Éclypse and Commodore23 (42.4 in); longest line, all three series (25 m).

LogisVert: indicative amount calculated by AirGreen under Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C) on the nominal 17 °F (−8.3 °C) capacity of the cold-climate ENERGY STAR record. Only Hydro-Québec confirms the assistance granted.

02 · Wall unit or multi-zone

At 18,000 BTU: one Commodore23 wall unit or a two-head MPD

Same nominal cooling capacity, two uses: one large room, or two rooms on a single outdoor unit.

Wall unit · AHRI certificate 201863352

Commodore23 18,000

Rooms served1
Heating at 8.3 °C19,800 BTU/h
SEER / HSPF20 / 10.5
Published limit−25 °C
Outdoor sound55 dB(A)
Lineup to 25 m
The Commodore23 page

Multi-zone · AHRI certificate 202110494

MPD 18,000

Rooms served2
Heating at 8.3 °C19,000 BTU/h
SEER / HSPF22 / 11
Published limit−20 °C
Outdoor sound56 dB(A)
Line20 m in total, 10 m per head
The 2-zone page

Per the two AHRI certificates, the MPD 18,000 has the better seasonal efficiency (SEER 22 against 20; its certificate names the OCD 9,000 and 12,000 wall heads); the Commodore23 18,000 gives a little more heat at 8.3 °C (19,800 against 19,000 BTU/h) and its sheet publishes a lower limit (−25 against −20 °C). Neither has a NEEP or ENERGY STAR record.

03 · Did you know

Three details on ACD wall units, from the sheets and manuals

20 m

The Révolution 9,000 takes the longest line at its size

At 9,000 BTU, ACD’s manuals limit the Éclypse and the Commodore23 to 15 m of line, and the Révolution to 20 m.

ACD SED, OCD and UHD manuals

54 °C

The Révolution has the highest published cooling range

ACD’s sheets publish a cooling range up to 54 °C outdoors for the Révolution, against 46 °C for the Éclypse and the Commodore23.

ACD Éclypse, Commodore23 and Révolution sheets

22,000

The three 24,000 units share one nominal cooling figure

At nominal cooling, the three ACD 24,000 wall units come in at 22,000 BTU/h: per the Éclypse sheet, the Commodore23’s AHRI certificate 201863353 and the NEEP list (record 406804) for the Révolution.

Éclypse sheet, AHRI certificate, NEEP list

04 · Questions

Your questions about ACD wall heat pumps

Which ACD wall heat pump for a Montréal winter?

The published heating limits run from −20 °C for the Éclypse to −30 °C for the Révolution; the Commodore23 from 9,000 to 24,000 publishes −25 °C. Only the Révolution 12,000, 18,000 and 24,000 have NEEP records: the 18,000, for example, is listed at up to 23,000 BTU/h at −8.3 °C (record 406805). The choice is made at the on-site assessment, based on the room and the backup heat.

ACD sheets; NEEP list, record 406805
Which ACD wall units can be eligible for LogisVert?

Among the ACD wall units sold in the shop, only the Révolution 12,000 and 24,000 have a cold-climate ENERGY STAR record for the pairing sold: indicative amount of $1,236 and $2,400, calculated by AirGreen under Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C) on the 17 °F (−8.3 °C) capacity of those records. Only Hydro-Québec confirms the assistance granted.

ENERGY STAR list, records 2649621 and 2415080, November 5, 2026; Hydro-Québec notice on the November 26, 2025 list update (ENERGY STAR only); LogisVert guide 1.10
Is Wi-Fi included on an ACD wall unit?

On the Révolution, yes: it is built in. On the Éclypse and the Commodore23, it goes through an optional ACD Wi-Fi key.

ACD sheets; ACD Wi-Fi key product page
What ACD warranty comes with a wall heat pump?

ACD standard warranty: 10 years on parts and 10 years on the compressor, for residential use in Québec, on a unit installed on or after January 1, 2021 and maintained every year as the manual requires.

ACD R410 standard warranty
Which ACD wall unit size should I choose?

The size is decided at the on-site assessment of your heating needs: room, windows, insulation and backup heat. The three series come from 9,000 to 24,000 BTU; above that, only the Commodore23 offers 30,000 and 36,000.

What does an ACD wall heat pump cost?

Pricing is by quotation, installation included. We do the estimate at your home, free and without obligation.

AirGreen · Heating and cooling

Three series, one right fit for your room: we choose it with you, at your home

We look at the room, the wall and the line route to the outdoor unit, assess your heating needs on site, then send you the quote. The estimate is free.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Sold and installed by AirGreen.Montréal, Laval, Longueuil, the South Shore and the North Shore
Free estimateAt home, no obligation
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville

Sources checked on November 5, 2026

  • ACD Éclypse, Commodore23 and Révolution technical sheets (FR and EN, no date printed): sizes, SEER, HSPF, sound levels, widths, operating limits.
  • ACD manuals: Éclypse SED (INS576), Commodore23 9,000 to 24,000 (INS515), Commodore23 30,000 and 36,000, Révolution UHD (INS528): line lengths and limits.
  • AHRI certificates of the Commodore23: 201863350 to 201863353, 202110509 and 202110510, issued March 3, 2022.
  • AHRI certificate 202110494 (MPD 18,000, which names the OCD 9,000 and 12,000 wall heads) and the ACD multi-zone sheet (code MPD-22): sound, published limit and line lengths of the MPD 18,000.
  • NEEP cold-climate heat pump list, records 406804, 406805 and 406806 (Révolution 24,000, 18,000 and 12,000), read on November 5, 2026: ashp.neep.org.
  • ENERGY STAR certified air-source heat pumps (Canadian market), records 2649621 and 2415080, read on November 5, 2026.
  • Hydro-Québec, LogisVert participation guide, residential, version 1.10 (September 15, 2026), and Hydro-Québec notice on the November 26, 2025 list update (ENERGY STAR only): hydroquebec.com.
  • ACD R410 standard warranty (bilingual) and the ACD Wi-Fi key product page (SED and OCD compatible).