AirGreenACD

AirGreen × ACD · 5 zones

Five rooms on one MPD outdoor unit: the 75 m budget

Sold and installed by AirGreen. Montréal, Laval, Longueuil, the South Shore and the North Shore.

The whole ACD space
  1. Home
  2. ACD
  3. Multi-zone
  4. 5 zones

ACD · MPD multi-zone · 5 heads

ACD five-head heat pump: 75 m of line set, is it enough?

Two MPD outdoor units have five ports: the MPD 36,000 and the MPD 42,000. Both take 75 m of line set in total, and 25 m at most for the longest line. Enter the length of each line: the tool adds them up and checks the published combinations.

Updated November 5, 2026 · ACD MPD sheets and manuals, AHRI certificates, ENERGY STAR

ACD MPD-22 and English multi-zone sheets

Five-head combinations published, outdoor unit by outdoor unit

MPD 36,0005 portsnone
MPD 42,0005 ports12

Both outdoor units have five ports; both ACD sheets publish five-head combinations only for the MPD 42,000.

2five-head ACD MPD systems in the shop: MPD 36,000 and 42,000
5ports on the MPD 36,000 and 42,000, the largest MPD outdoor units (ACD sheets)
75 mof line set in total on both, and 25 m at most for the longest line (MPD-22 sheet)
39,000BTU/h of nominal cooling for the MPD 42,000 per its MPD-22 sheet; the English sheet gives 36,000

This page answers

Five ACD heads: does the line set fit the budget?

The ACD shop · 5 zones

The five-head ACD MPD systems, right below

Two outdoor units, the MPD 36,000 and the MPD 42,000, each sold with five heads. Price on quotation.

01 · The 75 m budget

Five heads: does the line set fit the 75 m published?

Enter the line length of each head, from the outdoor unit to the room. The tool adds them up, finds the longest and compares them with the limits of the MPD 36,000 and 42,000.

The length of each line (m)

Limits: MPD-22 sheet and MPD manual (INS527), p. 14 and 15, the same for the MPD 36,000 and 42,000: 75 m in total, 25 m at most for the longest line, pre-charge for 40 m (yellow mark on the bar). The MPD-22 sheet calls for at least 3 m of line set: each field starts at 3 m. Combinations: ACD’s table, printed in both the MPD-22 sheet and the English multi-zone sheet.

Your five lines against the published budget

Total line set50 m of the 75 m published

Longest line14 m of the 25 m published

10 m beyond the 40 m covered by the pre-charge: the MPD-22 sheet calls for 0.2 oz of refrigerant per added foot (18.6 g/m), about 186 g here.

The two five-port MPD outdoor units
Outdoor unitLine-set budgetFive-head combinations published
MPD 36,000MPD36KCH21S-OProduct pagewithin75 m · 25 mnonein ACD’s sheets
MPD 42,000MPD42KCH21S-OProduct pagewithin75 m · 25 m12 combinationsin ACD’s sheets

50 m in total, within the 75 m published, and 14 m for the longest line, within the 25 m: the line set fits the published budget, the same for the MPD 36,000 and 42,000. With five heads, only the MPD 42,000 has published combinations.

02 · MPD 36,000: 4 heads yes, 5 no

MPD 36,000: 10 four-head combinations, none with five

Same outdoor unit, same AHRI certificate 202110503, same five ports: only the published list differs.

4 heads · AHRI certificate 202110503

MPD 36,000, 4 heads

Combinations published10, from 09 + 09 + 09 + 09 to 12 + 12 + 12 + 12
Ports left1
Largest head published24,000, in 09 + 09 + 09 + 24
Line set75 m in total, 25 m max. per line
Heating at 8.3 °C36,000 BTU/h
The 4-zone page

5 heads · AHRI certificate 202110503

MPD 36,000, 5 heads

Combinations publishednone
Ports left0
Largest head publishedno combination published
Line set75 m in total, 25 m max. per line
Heating at 8.3 °C36,000 BTU/h

03 · Did you know

Three details on five-head ACD systems, from ACD’s sheets and manuals

0

The MPD 36,000 has five ports, but no published five-head combination

The MPD-22 sheet gives it 2 to 5 connectable units and the English sheet 5 ports, but their table stops at four heads for it. An MPD 36,000 five-head system is also listed in the shop.

ACD MPD-22 sheet, p. 2 and 4; English ACD multi-zone sheet

5 types

ACD’s ordering example brings five head types together

The MPD-22 sheet’s ordering example uses an MPD 42,000 with 09 + 09 + 12 + 12 + 18: a wall head, a console, a ducted unit, a floor-ceiling unit and a cassette.

ACD MPD-22 sheet, p. 4

63,000

With five heads, the MPD 42,000 goes up to 150% of its size

The largest published five-head combinations, 09 + 09 + 09 + 18 + 18 and 09 + 12 + 12 + 12 + 18, add up to 63,000 BTU/h of heads: 150% of the 42,000 size, the ceiling ACD’s SMD and CCD manuals set for the sum of the heads running at once (AirGreen calculation on the size, not on the nominal capacity).

ACD MPD-22 sheet, p. 4; ACD SMD (X62411) and CCD (X62410) manuals, p. 4; AirGreen calculation

04 · Questions

Your questions about five-head ACD heat pumps

Which ACD outdoor unit for five rooms?

The MPD 42,000: it is the only outdoor unit for which ACD’s sheets publish five-head combinations, 12 in all, from 09 + 09 + 09 + 09 + 09 to 12 + 12 + 12 + 12 + 12. The MPD 36,000 also has five ports, but no published five-head combination. The choice is made at the on-site assessment of your heating needs.

ACD MPD-22 and English multi-zone sheets
Does the MPD 42,000 cool at 42,000 BTU/h?

The size is called 42,000, but the table of its MPD-22 sheet gives 39,000 BTU/h of nominal cooling, and ACD’s English sheet 36,000. No AHRI certificate is published for the MPD42KCH21S-O.

ACD MPD-22 sheet, p. 2; English ACD multi-zone sheet
A 24,000 head in a five-head system?

Only one combination allows it: 09 + 09 + 09 + 09 + 24, on the MPD 42,000. The 11 other five-head combinations stop at heads of 18,000 or less.

ACD MPD-22 sheet, p. 4; English ACD multi-zone sheet
Are the MPD 36,000 and 42,000 sold here ENERGY STAR?

Not on the ENERGY STAR list: neither the MPD36KCH21S-O nor the MPD42KCH21S-O is on the ENERGY STAR list (Canadian market) read on November 5, 2026. Since November 26, 2025, Hydro-Québec’s LogisVert program only covers ENERGY STAR heat pumps, so these five-head systems are not eligible.

ENERGY STAR list, November 5, 2026; Hydro-Québec notice on the November 26, 2025 list update (ENERGY STAR only)
What does a five-head ACD heat pump cost?

Pricing is by quotation, installation included: it depends on the MPD outdoor unit, the five heads and the route of the five lines. The home estimate is free and without obligation.

AirGreen · Heating and cooling

Five rooms, five lines: we measure them at your home

We map the route of the five lines to the outdoor unit, check the combination of the five heads, assess your heating needs on site, then send you the quote. The estimate is free.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Sold and installed by AirGreen.Montréal, Laval, Longueuil, the South Shore and the North Shore
Free estimateAt home, no obligation
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville

Sources checked on November 5, 2026

  • ACD multi-zone sheet (code MPD-22, 4 pages, 2018) and the English ACD multi-zone sheet: ports, combination table, ordering example, line lengths, pre-charge.
  • ACD MPD user manual (INS527), p. 14 and 15: line lengths and pre-charge.
  • ACD SMD ducted unit (X62411) and CCD cassette (X62410) manuals, p. 4: capacity of the heads running at once (150%).
  • AHRI certificate 202110503 of the MPD 36,000, issued August 9, 2022; no certificate published for the MPD42KCH21S-O.
  • ENERGY STAR list of certified air-source heat pumps (Canadian market), read on November 5, 2026: no record for the MPD36KCH21S-O and MPD42KCH21S-O.
  • Hydro-Québec, LogisVert residential participation guide, version 1.10 (September 15, 2026), and the Hydro-Québec notice on the November 26, 2025 list update (ENERGY STAR only): hydroquebec.com.

Price on quotation; free home estimate.