On their sheets, the 48,000 Regular leaves the factory with 4.2 kg of refrigerant, the 48,000 Max Performance with 4.3 kg.
Bosch, 48K Multi Zone Regular and Max Performance sheets, Gen 4, BTC 769208371 B and 769208370 C (01.2026)
BOSCH // Multi-zone 6 heads
Six rooms on a single unit: under what conditions?
Only the R-454B 48,000, Regular or Max Performance, takes six heads: wall units up to 36,000, cassettes and ducted units up to 24,000. The planner first shows the Regular 48,000 with six heads, from 12,000 down to 6,000, and flags any head too large for its type.
This page’s tool
Indicative LogisVert amount: our calculation, with the rates of Hydro-Québec’s participation guide (version 1.10 of September 15, 2026), $120 per 1,000 BTU/h for a cold-climate heat pump and $50 otherwise, applied to the capacity at 17 °F (-8.3 °C) certified by ENERGY STAR Canada, for an outdoor unit of at least 12,000 BTU/h nominal in cooling. The amount depends on the installation date. Only Hydro-Québec confirms the assistance granted.
The models
The comparison that matters
At 48,000 BTU/h on R-454B, the Max Performance weighs 111.8 kg (246 lb), the Regular 100.7 kg (222 lb), per the Bosch sheets.
Who brings what
Did you know
On their sheets, the 48,000 Regular leaves the factory with 4.2 kg of refrigerant, the 48,000 Max Performance with 4.3 kg.
Bosch, 48K Multi Zone Regular and Max Performance sheets, Gen 4, BTC 769208371 B and 769208370 C (01.2026)
The minimum room area depends on the refrigerant charge taken into account (on the 48,000, the releasable charge) and on the head height: for 5 kg, Bosch asks for 15.36 m² (166 ft²) with a head installed between 1.8 and 2.2 m, and 11.26 m² (121 ft²) at 3.0 m.
Bosch, Gen 4 multi-zone installation manual, BTC 769203312 D (04.2026), tables 3 and 5, pp. 6 and 7
To work out the releasable charge, the multi-zone manual starts from 204 g, then adds 393 g per 6,000 to 12,000 head, 482 g per 18,000 head and 1,025 g per 24,000 or 36,000 head; beyond 7.5 m of line, it adds 20 g per metre (6,000 to 18,000 heads) or 50 g per metre (24,000 and 36,000); the table has no row for a 30,000 head.
Bosch, Gen 4 multi-zone installation manual, BTC 769203312 D (04.2026), table 4, p. 7
Warranties
Sold and installed by AirGreen. In Montréal, Laval, Longueuil, on the South Shore and the North Shore.
RBQ licence 5645-9605-01: subclasses 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
The size is confirmed by an on-site assessment of heating needs, room by room, before any quote. Sold and installed by AirGreen.