DURASTAR · Central ADD-ON systems · Advanced R-454BDURASTAR Advanced R-454B central ADD-ON systems at AirGreenSold and installed by AirGreen across Montreal, Laval, Longueuil, the South Shore and the North Shore.
Find my DURASTAR
AirGreen × DURASTARSold and installed by AirGreenAdvanced: two-stageR-454B “Low GWP”6 units in this collectionMontreal · Laval · Longueuil · South Shore · North Shore
01 · The DURASTAR selector

Pick a size. Every card is a real DURASTAR listing on our site.

Heat at -8 °C and -15 °C from each listing, the cold limit DURASTAR publishes for the family, and the LogisVert amount when the listing has an AHRI number.

Size

6 units shown

Thermopompe Centrale ADD-ON DURASTAR Advanced | 3 Tonnes - 36000 BTU (Serpentin 17,5 po) - R454B — installée par AirGreen à Montréal, Laval, Longueuil, Rive-Sud et Rive-Nord
AdvancedR-454B

36,000 BTU/h

Coil 17.5 inDRHP15B36AJ2ANANo AHRI number

Heat at -8 °C
23,400 BTU/h
Heat at -15 °C
—
Heats down to
Not published
SEER2 · HSPF2
15.2 · 7.8
LogisVertOn quote
Thermopompe Centrale ADD-ON DURASTAR Advanced | 3 Tonnes - 36000 BTU (Serpentin 21 po) - R454B — installée par AirGreen à Montréal, Laval, Longueuil, Rive-Sud et Rive-Nord
AdvancedR-454B

36,000 BTU/h

Coil 21 inDRHP15B36AJ2ANANo AHRI number

Heat at -8 °C
23,400 BTU/h
Heat at -15 °C
—
Heats down to
Not published
SEER2 · HSPF2
15.2 · 7.8
LogisVertOn quote
Thermopompe Centrale ADD-ON DURASTAR Advanced | 3.5 Tonnes - 42000 BTU (Serpentin 21 po) - R454B — installée par AirGreen à Montréal, Laval, Longueuil, Rive-Sud et Rive-Nord
AdvancedR-454B

42,000 BTU/h

Coil 21 inDRHP15B42AJ2ANANo AHRI number

Heat at -8 °C
27,000 BTU/h
Heat at -15 °C
—
Heats down to
Not published
SEER2 · HSPF2
15.2 · 7.8
LogisVertOn quote
Thermopompe Centrale ADD-ON DURASTAR Advanced | 3.5 Tonnes - 42000 BTU (Serpentin 24,5 po) - R454B — installée par AirGreen à Montréal, Laval, Longueuil, Rive-Sud et Rive-Nord
AdvancedR-454B

42,000 BTU/h

Coil 24.5 inDRHP15B42AJ2ANANo AHRI number

Heat at -8 °C
27,000 BTU/h
Heat at -15 °C
—
Heats down to
Not published
SEER2 · HSPF2
15.2 · 7.8
LogisVertOn quote
Thermopompe Centrale ADD-ON DURASTAR Advanced | 5 Tonnes - 60000 BTU (Serpentin 21 po) - R454B — installée par AirGreen à Montréal, Laval, Longueuil, Rive-Sud et Rive-Nord
AdvancedR-454B

60,000 BTU/h

Coil 21 inDRHP15B60AJ2ANANo AHRI number

Heat at -8 °C
35,400 BTU/h
Heat at -15 °C
—
Heats down to
Not published
SEER2 · HSPF2
15.2 · 7.8
LogisVertOn quote
Thermopompe Centrale ADD-ON DURASTAR Advanced | 5 Tonnes - 60000 BTU (Serpentin 24,5 po) - R454B — installée par AirGreen à Montréal, Laval, Longueuil, Rive-Sud et Rive-Nord
AdvancedR-454B

60,000 BTU/h

Coil 24.5 inDRHP15B60AJ2ANANo AHRI number

Heat at -8 °C
35,400 BTU/h
Heat at -15 °C
—
Heats down to
Not published
SEER2 · HSPF2
15.2 · 7.8
LogisVertOn quote

Heat at -8 °C and -15 °C: values from each product listing; when the listing has an AHRI number, they are the ENERGY STAR (or NEEP) figures for that number. Cold limit: operating range published by DURASTAR for the family. “Standard” is our name for DURASTAR’s non-Sirius range.

AirGreen × DURASTAR

DURASTAR on the unit. A local team to install it.

DURASTAR puts its name and its spec sheet on the unit. AirGreen picks it with you, installs it and checks your LogisVert amount. Each does what it does best.

DURASTAR

What DURASTAR brings

  • Coils from 14.5 to 24.5 inThe width follows your furnace’s.
  • Advanced: two-stageDRHP15, from 1.5 to 5 tons.
  • R-454B “Low GWP”With leak detection, per DURASTAR’s spec sheets.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenMontreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free on-site estimateWe look at your home and choose the family and the size.
  • LogisVert checked by AHRI numberThe amount for the exact AHRI number, in Hydro-Québec’s tool.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.

The result: the right DURASTAR, chosen with you and installed by AirGreen, with the LogisVert amount checked.

02 · How it works

Your furnace stays. The heat pump joins it.

Tap a step to see it on the diagram.

BasementDURASTARFurnace1234

Heating: heat from outside comes into the home.

03 · This collection in numbers

What these 6 listings say, once you line them up.

Every number below is read live from the product listings in this collection. Change a listing and the page follows.

SEER215.2the same on every listing here. Seasonal cooling efficiency across these listings: higher means less electricity for the same cooling
Outdoor models3different DURASTAR outdoor units behind these 6 listings: DRHP15B36AJ2ANA, DRHP15B42AJ2ANA, DRHP15B60AJ2ANA
Wi-Fi6/6listings where Wi-Fi control is offered as an option

SEER2, listing by listing

Tap a bar to open its listing.
04 · The cold

How much heat is left when it gets cold, listing by listing.

Dark bar: heat at -8 °C. Light bar: at -15 °C. On the right, the limit DURASTAR publishes for each family.

The cold limit, by family

Advanced
Not published

“Down to”: heating operating range from DURASTAR’s spec sheets (Sirius Heat: -22 °F / -30 °C; non-Sirius: -13 °F / -25 °C; 115 V: -4 °F / -20 °C). Sirius Heat keeps 100% of its rated heating capacity down to 0 °F (-18 °C). DURASTAR publishes no minimum for Advanced and Core.

Why the light bar is sometimes longer: in ENERGY STAR’s listing, the -8 °C (17 °F) figure is the capacity at the certification test point, while the -15 °C (5 °F) figure is the maximum capacity. Both come from the same AHRI number.

Slide the thermometer

-20 °C
Advancedno limit publishedNot published

Move the slider: we count how many of the 6 units in this collection are still inside the heating range DURASTAR publishes.

05 · The coil matcher

How wide is your furnace? Tap it.

The coil sits on top of your furnace, so its width follows the furnace. We measure it during the free estimate; here you can already see which listings match.

3 coil widths in this collection.

AirGreen installs the heat pump and the coil (RBQ 15.8, 15.10 and 16).

See the matching listings
06 · Did you know?

6 facts about these DURASTAR units and how they work. Flip the cards.

07 · Good to know

What to know before choosing.

01

The coil width

Each ADD-ON listing gives the coil width (14.5, 17.5, 21, 21.5 or 24.5 in). We measure it on your furnace during the estimate.

02

One AHRI number per pairing

With an ADD-ON, the same coil is certified several times, once per combination with the furnace. So the Advanced and Core listings show none: we find the right number, and the LogisVert amount that goes with it, during the quote.

03

Gas or oil furnace

AirGreen installs the heat pump and the coil (RBQ 15.8, 15.10 and 16). Any work on the furnace’s gas or oil supply goes to a contractor licensed for gas or oil.

04

The furnace blower does the work

With an ADD-ON, your furnace’s blower pushes the air through the coil, then into your existing ducts.

08 · The DURASTAR range at AirGreen

The neighbouring DURASTAR collections.

Number of units on our site, live.

09 · LogisVert

The LogisVert amount is confirmed in the quote.

Hydro-Québec pays $120 per 1,000 BTU/h of heat at -8 °C for an ENERGY STAR cold-climate heat pump, $50 for a standard ENERGY STAR one, if the outdoor unit is at least 12,000 BTU/h. With an ADD-ON, each certified combination has its own AHRI number, and the furnace the coil sits on is part of it: that is why some listings say “on quote”.

Listings with a LogisVert amountAHRI number on the listing
0
Listings “on quote”no AHRI number, or an amount we still have to confirm
6
Under 12,000 BTU/h outsidenot eligible
$0

Amounts come from each product listing, by AHRI number, from Hydro-Québec’s LogisVert tool. Only Hydro-Québec confirms the aid granted.

10 · Warranty

Advanced and Core: register it, and the parts warranty doubles.

10 years on parts

  • Register within 90 days of installation to go from 5 to 10 years.
  • No labour included by the manufacturer.
  • Original owner only, non-transferable; valid in Canada.

Source: limited warranty for DRHP heat pumps and DRAH air handlers (document 92-26150, warrantor Rheem Sales Company) and durastar.com, checked October 6, 2026.

Where we install

4,632 installs published on our blog, all brands.

Count of published “Nos réalisations” articles by region, October 6, 2026. 343 articles with no recognized city are not in the bars.

See our installs
Montreal2,403
Longueuil and South Shore614
Laval487
North Shore401
West Island343
Vaudreuil-Soulanges41
11 · Questions

What people ask us about these DURASTAR units.

What is a central ADD-ON?

An outdoor heat pump and a coil added to your existing furnace, which you keep. “ADD-ON” is our name for this setup.

Which coil width?

Your furnace’s: from 14.5 to 24.5 in depending on the listing. We measure it during the free estimate.

And LogisVert?

The amount shown comes from the listing’s AHRI number. When the listing has none (Advanced and Core ADD-ON, where each pairing with the furnace has its own number), it is confirmed in the quote.

Does my gas or oil furnace work with it?

We measure the space for the coil during the estimate. Any work on the gas or oil supply goes to a licensed gas or oil contractor.

How much is an installed DURASTAR?

Every installation is different: the estimate is free and the price comes with the quote.

Who makes DURASTAR?

DURASTAR is the house brand of Ferguson, a large North American heating and cooling distributor; in Canada, Ferguson does business as Wolseley. The Advanced and Core central systems are warranted by Rheem Sales Company. DURASTAR does not publish who makes its mini-splits.

AirGreen × DURASTARSold and installed by AirGreenAdvanced: two-stageR-454B “Low GWP”RBQ 5645-9605-01
Sources

Sources checked on October 8, 2026

  1. DURASTAR product pages and spec sheets (Sirius Heat and non-Sirius mini-splits, R-454B V1.1 Jan. 2025 and R-410A; Elite central V1.3 May 2026; Advanced PDS-848 and Core PDS-846, 2025), durastar.com.
  2. DURASTAR submittal DRA4U28M2A (form V1.0_10.24, © 2024 Ferguson Enterprises): heating operating range -13 to 75 °F (-25 to 24 °C).
  3. DRHP heat pump and DRAH air handler limited warranty (document 92-26150, Rheem Sales Company).
  4. ENERGY STAR certified air-source heat pumps (data.energystar.gov, dataset w7cv-9xjt) and NEEP, by AHRI number, as carried on each product listing.
  5. Hydro-Québec, LogisVert heat pump search tool and residential participation guide v1.10, September 15, 2026.
  6. AirGreen: DURASTAR catalogue on airgreen.ca, read live from this collection.

LogisVert amounts come from Hydro-Québec’s tool; only Hydro-Québec confirms the aid granted.

Price on quoteEvery installation is different: the estimate is free and the price comes with the quote.

The DURASTAR shop

The 6 units of this collection, right below.

Filter by capacity, then compare the product listings. When a listing has an AHRI number, its LogisVert amount is shown.

DURASTAR