-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
Zephyr R-454B central heat pump: series 6, four tonnages.
Four Zephyr pairs, from 2 to 5 tons: the ZE-6xxHPA outdoor unit and the AH-6xxA air handler of the same tonnage. R-454B, variable-speed compressor, leak sensor in the air handler, heating down to -30 °C. All ENERGY STAR cold-climate certified.
LogisVert amount of each pair, checked by AHRI number.
ENERGY STAR (Oct. 8, 2026); Hydro-Québec LogisVert tool (Oct. 6, 2026).
Four pairs, same tonnage inside and out.
Each certified Zephyr pair matches the ZE-6xxHPA with the AH-6xxA air handler of the same tonnage, as the manual requires in test mode. Tap a tonnage: certified heat at +8.3, -8.3 and -15 °C compares with certified cooling (red mark).
In its ENERGY STAR record, the 2-ton gives more heat at -15 °C (20,800 BTU/h) than at -8.3 °C (20,400 BTU/h): the two values are separate test points, shown as published.Source: ENERGY STAR, AHRI 215381145.
Certified figures, pair by pair.
All four Zephyr pairs are cold-climate certified and meet the “Most Efficient” criteria. The cased coil pairings are compared in section 06.
| 2 tonsZE-624HPA | 3 tonsZE-636HPA | 4 tonsZE-648HPA | 5 tonsZE-660HPA | |
|---|---|---|---|---|
| Zephyr pair: outdoor unit and air handler of the same tonnage | ||||
| AHRI | 215381145 | 215381146 | 215381147 | 215381148 |
| Certified cooling | 24,000 | 32,000 | 48,000 | 57,000 |
| SEER2 | 20 | 19.5 | 19 | 19 |
| EER2 | 12 | 11.7 | 12 | 11 |
| HSPF2 | 10 | 10.5 | 9 | 9 |
| Heat at +8.3 / -8.3 / -15 °C | 24,000 / 20,400 / 20,800 | 32,000 / 32,000 / 31,000 | 48,000 / 36,600 / 37,000 | 57,000 / 37,000 / 42,000 |
| COP at -15 °C | 2.3 | 2.15 | 2.52 | 2.46 |
| LogisVert | $2,448 | $3,840 | $4,392 | $4,440 |
| Status | Cold climate · Most Efficient criteria | Cold climate · Most Efficient criteria | Cold climate · Most Efficient criteria | Cold climate · Most Efficient criteria |
Swipe the table.
ENERGY STAR w7cv-9xjt, Oct. 8, 2026. Each Zephyr pair also has a second AHRI number (215434507 to 215434510, air handler entered as “AH- 6xxA”) with the same SEER2 and HSPF2.
The 2-ton and the 4-ton have the series’ best EER2, 12.0; the 3-ton is at 11.7 and the 5-ton, at 11.0.Source: ENERGY STAR, AHRI 215381145 to 215381148.
One amount per AHRI number, checked in Hydro-Québec’s tool.
Hydro-Québec lists the four AH-6xxA air handler pairs by AHRI number (215381145 to 215381148). Tap a pair: the math, the number and your application deadline appear.
- An air handler or ducts installed outside the insulated envelope, for example in the attic.
- Replacing a single coil, or a single indoor or outdoor unit.
- A central unit in a home with a geothermal system.
ZE-660HPA + AH-660A
July 8, 2027deadline passed
Source: Hydro-Québec, residential LogisVert participation guide v1.10 (Sept. 15, 2026) and eligible heat pump search tool (Oct. 6, 2026). ENERGY STAR required since Nov. 26, 2025; outdoor unit of at least 12,000 BTU/h; capped at 100% of the cost before taxes; apply no later than 9 months after installation; paid by mail 10 to 12 weeks after a complete application. Indicative amounts: Hydro-Québec sets them when you apply. Our LogisVert guide
The 4-ton ($4,392) and the 5-ton ($4,440) differ by only $48: their heat at -8 °C is almost the same, 36,600 and 37,000 BTU/h.Source: Hydro-Québec, LogisVert tool (Oct. 6, 2026), AHRI 215381147 and 215381148.
Simulate a leak: the air handler reacts on its own.
R-454B is an A2L, mildly flammable refrigerant. The AH-6xxA air handler has a refrigerant detection system: tap “Leak detected” to see what the Zephyr manual specifies.
The refrigerant detection sensor (No. 18 in the manual) watches for leaks in the air handler. The indoor unit must stay powered, except for service.
Per UL Solutions, an A2L refrigerant detection system must call for mitigation (such as starting the indoor fan) within 15 seconds and hold it for at least 5 minutes.Source: UL Solutions, “Inspecting refrigerant detection systems in HVAC equipment”, Oct. 21, 2024.
Winter in COP, summer in SEER2.
The first panel gives each pair’s COP at -15 °C per ENERGY STAR; the second, the electricity needed to cool a season based on each pair’s SEER2: slide the heat to remove.
COP at -15 °C (5 °F), ENERGY STAR; resistance: 100% (US DOE).
Illustrative math: SEER2 is, by definition (DOE, Appendix M1), the heat removed over the season divided by the electricity used, in BTU per watt-hour. Cost at Hydro-Québec’s Rate D second-tier price (11.142¢/kWh since April 1, 2026), which applies if use exceeds the first tier (40 kWh per day, times the number of days in the period); below it, a kWh costs 7.065¢. Before taxes and access fees. Your home will have its own numbers.
The 3-ton has the series’ lowest COP at -15 °C (2.15), but the highest HSPF2 (10.5): COP measures a single test point, HSPF2 a whole heating season.Source: ENERGY STAR, AHRI 215381146.
Zephyr air handler or existing furnace: two certified pairings.
The same ZE-6xxHPA is certified two ways: with the Zephyr AH-6xxA air handler of the same tonnage, or with a cased coil installed on an existing furnace. Pick a tonnage and compare.
AH-6xxA air handler
ZE-636HPA + AH-636A · AHRI 215381146
DC cased coil
ZE-636HPA + DC37D3J · AHRI 218160014
ENERGY STAR w7cv-9xjt (Oct. 8, 2026): ZE-6xxHPA + AH-6xxA pairs (“Ultra” series) and ZE-6xxHPA + DC coil pairs (“Ultra-Coil” series, on the market since March 6, 2026, certified May 1, 2026). ENERGY STAR does not name the coil brand; TTI publishes a “Case coil Aspen avec Zephyr centrale” document. Scales: SEER2 0 to 22, HSPF2 0 to 11, BTU/h 0 to 58,000, COP 0 to 3.
If the coil pairs are eligible, the same math (heat at -8 °C × $120 per 1,000 BTU/h) would give $2,040, $3,120, $3,960 and $4,080: $360 to $720 less than the air handler pairs, depending on tonnage. AirGreen calculation, to be confirmed by Hydro-Québec.Source: ENERGY STAR, AHRI 215381145 to 215381148 and 218160013 to 218160016; Hydro-Québec, LogisVert tool (Oct. 6, 2026); AirGreen math.
What the Zephyr manual asks of the technician.
A few requirements from the R-454B outdoor unit manual. They explain why start-up is done in test mode, with units of the same tonnage.
Zephyr series 6 R-454B manual, p. 13: charging by subcooling only applies in test mode.
- In test mode, the indoor and outdoor units must have the same tonnage.
- Add no more than 3/8 lb (6 oz) of refrigerant at a time.
- Operating range: heating down to -30 °C, cooling from -15 to 52 °C (outdoors).
The Zephyr manual tells installers to add no more than 6 oz (3/8 lb) of refrigerant at a time when charging by subcooling.Source: TTI, “Zephyr R454b 6 series centrale” (No. 20) and “Zephyr AH-6__A” (No. 22) manuals, readable parts, checked Oct. 8, 2026: operating range, subcooling, leak detection.
Series 6 R-454B, molecule by molecule.
R-454B has a GWP of 470 and class A2L. That class is why the air handler includes a leak sensor. In Canada, no GWP limit applies to residential heat pumps.
EPA SNAP, March 19, 2026.
R-454B is a blend: 68.9% R-32 and 31.1% R-1234yf, per ASHRAE designations. Its GWP of 470 is 77.5% lower than R-410A’s (2,090).Source: ASHRAE designations; EPA SNAP (March 19, 2026); AirGreen math.
Series 6, date by date.
Swipe left to right. In red: Zephyr; in green: rules.
- Series 6 R-454B
Market date of the four ZE-6xxHPA + AH-6xxA pairs, on the same day, per ENERGY STAR.
Zephyr - US: GWP under 700
Residential systems installed must use a refrigerant with a GWP under 700, unless their components were made or imported before 2025.
Rule - LogisVert requires ENERGY STAR
Only certified heat pumps remain eligible.
Rule - Cased coils
Market date of the ZE-6xxHPA with a DC cased coil (Aspen, per TTI).
Zephyr - Certification date
ENERGY STAR certification date listed for the 2, 4 and 5-ton (3-ton: April 9).
Zephyr - Coil pairs certified
ENERGY STAR certification of the “Ultra-Coil” pairs (AHRI 218160013 to 218160016).
Zephyr - EPA: deadline removed
Pre-2025 components can still be installed in the US.
Rule - 6-year legal warranty
For heat pumps bought new from that date (OPC).
Rule
The four pairs of series 6 reached the market on the same day, August 27, 2024, and share the “Ultra” series at ENERGY STAR.Source: ENERGY STAR w7cv-9xjt (Oct. 8, 2026).
A ZEPHYR series 6, started up per the manual.
ZEPHYR supplies the ZE-6xxHPA and the AH-6xxA air handler of the same tonnage, with its refrigerant sensor. AirGreen checks the ducts, starts the system up in test mode and writes the exact AHRI number on the quote.
What ZEPHYR brings
- Test modeCharging by subcooling, same tonnage inside and out.
- Sensor No. 18In the AH-6xxA air handler, per the manual.
- Down to -30 °CPer the series 6 manual.
- “Most Efficient” criteriaAll four pairs, per ENERGY STAR.
What AirGreen brings
- Sold and installed by AirGreenMontreal, Laval, Longueuil, the South Shore and the North Shore.
- Free home estimateWe look at the rooms, where the units go and the line set route.
- Warranty registered for youWith TTI, free of charge: serial numbers, date, photos.
- RBQ 5645-9605-01Subclasses 15.8 (ventilation), 15.10 (refrigeration) and 16 (electrical).
The result: a well-matched series 6, charged per the manual, with the right AHRI number.
What is written, and what the law says.
TTI does not publish a warranty term for the series 6 central unit online; we put it on your quote. For a heat pump bought new on or after October 5, 2026, the law adds a 6-year warranty of good working order, counted from delivery.
TTI does not publish a warranty term for this product online (checked Oct. 8, 2026). We write it down on your quote.
For a heat pump or air conditioner bought new from a merchant on or after October 5, 2026, Quebec law adds a free, automatic 6-year warranty of good working order, counted from delivery (Office de la protection du consommateur). Under TTI’s parts policy (v3.4, July 17, 2026), labour to replace a part during that period falls on the installing contractor.
Service or repair by anyone not certified and authorized by TTI (or Kinghome) ends the manufacturer’s conventional warranty (TTI, s. 4.4).
If something breaks, you call the contractor who installed it; they file the claim with TTI.
TTI’s policy asks owners to clean the indoor unit filters at least once a month (s. 6.3).
We look at the rooms, where the units go and the line set route.
The exact model, the AHRI number, the indicative LogisVert amount when it applies.
Vacuum, refrigerant charge, heating and cooling tests.
We register the units with TTI for you: nameplate, serial numbers, invoice.
Our Zephyr central projects, all generations.
Each blog post shows one installation: the unit, the place, how it was done.




What people ask us about Zephyr central units.
No question matches. Call us at 514-316-2973.
The certified Zephyr pairs match the same tonnage, and the manual requires the same tonnage in test mode. The ZE-6xxHPA is also certified with DC cased coils (Aspen, per TTI), at lower ratings.
R-454B is an A2L refrigerant. The AH-6xxA air handler has a detection system: on a leak, the fan must run and the compressor must stop, per the Zephyr manual.
ENERGY STAR lists each Zephyr pair under two numbers: 215381145 to 215381148, and 215434507 to 215434510 (air handler entered as “AH- 6xxA”), with the same SEER2 and HSPF2. The LogisVert amounts on this page were checked with numbers 215381145 to 215381148: those are the ones we put on the quote and invoice.
The series 6 manual states that charging by subcooling only applies in test mode, with indoor and outdoor units of the same tonnage. Target subcooling (± 1 °F): 2 tons: 8 °F, 3 tons: 9 °F, 4 tons: 9 °F, 5 tons: 8 °F. We add no more than 6 oz of refrigerant at a time.
Heating down to -30 °C and cooling from -15 to 52 °C (outdoors), per the manual. ENERGY STAR certifies heat at -15 °C: 20,800 (2 tons), 31,000 (3), 37,000 (4) and 42,000 BTU/h (5).
Yes: Hydro-Québec lists pairs by AHRI number. The AH-6xxA air handler pairs (215381145 to 215381148) qualify for $2,448, $3,840, $4,392 and $4,440 per Hydro-Québec’s tool (Oct. 6, 2026). The amount for the cased coil pairs has not been verified.
It is the indoor coil installed on an existing furnace, instead of the Zephyr air handler. With the ZE-6xxHPA, ENERGY STAR certifies the DC coils (Aspen, per TTI; AHRI 218160013 to 218160016) at 16 to 16.5 SEER2 and 8.2 to 8.3 HSPF2, without meeting the “Most Efficient” criteria.
ENERGY STAR certifies it at 32,000 BTU/h of cooling, and the 5-ton at 57,000. We always give you the certified figure.
TTI does not publish a warranty term online for the series 6 central unit and air handler: we put it on the quote. For a heat pump bought new on or after October 5, 2026, Quebec law adds a 6-year warranty of good working order, counted from delivery.
Nine months after installation. Hydro-Québec pays by mail, 10 to 12 weeks after a complete application. The invoice must show the RBQ licence and the AHRI or ENERGY STAR number.
Your Zephyr central unit, on your ducts, installed by AirGreen.
We come and see the ducts, choose the tonnage and backup with you, and hand you a clear quote with the AHRI number and the indicative LogisVert amount.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.
Sources checked October 6 to 9, 2026
- ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt, updated Oct. 8, 2026), checked Oct. 8, 2026: SEER2, EER2, HSPF2, capacities at 47, 17 and 5 °F, COP at 5 °F, cold-climate status, market date, by AHRI number.
- TTI, “Zephyr R454b 6 series centrale” (No. 20) and “Zephyr AH-6__A” (No. 22) manuals, readable parts, checked Oct. 8, 2026: operating range, subcooling, leak detection.
- TTI, “Case coil Aspen avec Zephyr centrale” (No. 19) and Aspen DC coil brochure (No. 35), tticlimatisation.com/manuels, checked Oct. 8, 2026; ENERGY STAR, AHRI 218160013 to 218160016 (“Ultra-Coil” series).
- Hydro-Québec, residential LogisVert participation guide, version 1.10, Sept. 15, 2026 (2026G448F), and eligible heat pump search tool, checked Oct. 6, 2026.
- Hydro-Québec, Electricity rate grid as of April 1, 2026 (2026G028-2F) and Rate D page, accessed Oct. 8, 2026.
- TTI, parts availability policy, version 3.4, July 17, 2026 (ss. 4.3, 4.4 and 6.3: labour during the legal warranty, certified and authorized technician, filter cleaning).
- US EPA, SNAP, “Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps”, updated March 19, 2026 (GWP and ASHRAE classes); ASHRAE refrigerant designations (R-454B = R-32/R-1234yf 68.9/31.1) and Addendum g to Standard 34-2016 (class 2L).
- US eCFR, 40 CFR 84.54 (current to Oct. 5, 2026) and EPA fact sheet of May 21, 2026 on the Technology Transitions rule.
- Ozone-depleting Substances and Halocarbon Alternatives Regulations (SOR/2016-137), Schedule 1.1, current to Apr. 28, 2026.
- UL Solutions, “Inspecting refrigerant detection systems in HVAC equipment”, Oct. 21, 2024.
- US DOE, 10 CFR 430, Subpart B, Appendices M and M1 (SEER, HSPF, COP definitions); DOE Energy Saver, “Electric Resistance Heating”.
- TTI Climatisation Chauffage, home page and FAQ (tticlimatisation.com), checked Oct. 8, 2026.
- AirGreen: airgreen.ca product pages and “Nos réalisations” blog, as of Oct. 8, 2026.
- Office de la protection du consommateur, warranty of good working order (opc.gouv.qc.ca) and legal warranty notice, checked Oct. 9, 2026; Order in Council 1459-2025, Gazette officielle du Québec (s. 79.21 of the regulation under the Consumer Protection Act, in force Oct. 5, 2026): air conditioner and heat pump, 6 years.
- Hydro-Québec, residential LogisVert program page and fraud prevention page (hydroquebec.com), checked Oct. 9, 2026: no telephone or door-to-door solicitation for LogisVert.
LogisVert amounts are indicative: Hydro-Québec sets them when you apply.
Zephyr central units, right below.
Each product page matches a tonnage. Prices on quote. Free home estimate.

