APRILAIRE 800 and HONEYWELL HM700, steam humidifiers

Home / Comparisons / Steam humidifiers

Comparison · Steam humidifiers · whole house

APRILAIRE 800 and HONEYWELL HM700, from litre to steam

Both boil tap water between two electrodes and send the steam into the ducts. What they produce depends mostly on how they are wired: 120, 208 or 240 V, and for the AprilAire, 11.5 or 16 A. Here is every published setting, in litres and kilowatt-hours.

Highest published output · 34.6 gal/day · 22 gal/day Published voltages · 120 / 208 / 240 V · 120 / 240 V How steam is made · electrodes, both
Honeywell HM700A1000 steam humidifier, AirGreen product card
Honeywell Home · Resideo

HONEYWELL HM700

HM700A1000/U · cylinder HM700ACYL2 · HumidiPRO H6062

See the product page
From litre to steam

What each one produces, depending on how it is wired

Pick the house voltage and, for the AprilAire, the current setting. Both documents give output in US gallons a day and power in kilowatts; the page converts them to litres and works out the electricity per litre of steam, formula shown.

No “Cost per season” block on this page: a humidifier has no HSPF2 or SEER2, so the cost method of our heat pump comparisons does not apply.

House voltage
AprilAire setting (DIP switch 1)

Electricity per litre of steam, at full output

Formula: kWh/L = kW × 24 h ÷ (gal/day × 3.785) · 1 US gallon = 3.785 litres. The kilowatts and gallons a day are those each manufacturer publishes for the chosen setting; the ratio is AirGreen's arithmetic on those rated values, not a measurement.

How they make steam

Two electrodes in a throwaway cylinder, in both

Current flows from one electrode to the other through the water. The water resists, heats and boils. The higher the water rises on the electrodes, the more current and steam; the unit fills until the current meets demand. The minerals stay in the cylinder, which is replaced whole.

Steam to the duct Cold water Drain (tempered water) Electrodes Throwaway cylinder Power

Diagram, not a photo. Principle described in both manuals; the real parts differ from one model to the other.

APRILAIRE 800

Model 80 canister for most installations, hard or softened water; Model 80LC for water below 300 µS/cm or a 120 V installation, never with softened water. It is replaced when the Service light flashes red.

HONEYWELL HM700

A single approved cylinder, the HM700ACYL2. Its life depends on the water and the use; when scale has worn it out, the yellow light flashes four times and the unit stops. Resideo advises keeping a spare during the season.

Same principle, different settings

The AprilAire is set by current (11.5 or 16 A) and by voltage with a jumper; it leaves the factory at 240 V and 11.5 A. The HM700 is set by voltage only (110/120 or 220/240 V) and draws 12 A either way, per its specification table.

The water they need

Tap water that conducts well enough, at the right pressure

An electrode humidifier needs the minerals in the water to carry the current. Both manuals rule out demineralized and reverse-osmosis water. Each bar shows the range written by the manufacturer, on the same scale for both.

Installation

On the wall, near the duct, with a drain and a circuit of its own

Steam output drops along the way: the longer the hose, the less reaches the duct. AprilAire puts numbers on that loss; Resideo states it without numbers.

Length of the steam hose or pipe

6 ft

AprilAire: Table 4 of the installation manual (supplied hose 6 ft at most; beyond that, 1 in. insulated pipe). The voltage and setting chosen above apply here too. Resideo: 5 ft hose in the HM700ADISTKIT kit, 15 ft kit optional, 20 ft at most “as a best practice”.

Both units at the same scale

AprilAire 800, cut-out photo
10 1/8 in.
APRILAIRE 800height 20 7/8 in.
Honeywell HM700A1000, cut-out photo
11.5 in.
HONEYWELL HM700height 21.5 in.

Photos scaled to the height each manufacturer publishes. The HM700 photo is a three-quarter view.

InstallationAPRILAIRE 800HONEYWELL HM700
Electrical
Power supply120, 208 or 240 V, 60 Hzshipped at 240 V, 11.5 A110/120 or 220/240 V, single phasefactory configured; Resideo advises against changing the jumpers
Electrical protectionDedicated circuit, 20 A minimum at 11.5 A; 25 A minimum at 16 AInstallation manual, pp. 13–14Dedicated 15 A breaker, ground-fault protected circuitInstructions 33-00118EFS, p. 10
Power at full output1.4 to 3.8 kWdepending on voltage and setting1.4 or 2.8 kWat 110/120 or 220/240 V
Water and drain
Supply water pressure25 to 120 psi30 to 100 psi
Water conductivity125 to 1,250 µS/cmspec sheet 01.26; the 2018 manual also writes 100 µS/cm on p. 7150 to 1,200 µS/cmrecommended value
Drain7/8 in. ID tubing supplied; water tempered below 60 °C (140 °F) by the cold inlet waterWater cooled to 60 °C (140 °F) on automatic drains; tubing and drain rated for 93 °C (200 °F)
Mounting
Steam hose, length6 ft hose supplied; beyond that, 1 in. insulated pipe; Table 4 goes to 20 ft5 ft in the HM700ADISTKIT kit; 20 ft at most
Maximum duct static pressure2 in. w.c.3.0 in. w.c.
Minimum duct airflowNot published by the manufacturer. The manual gives an absorption distance by air speed instead.115 CFM at 110/120 V; 230 CFM at 220/240 V
Clearances30 in. for service; 16 in. for the hose, wiring and drain (fig. 8)On the wall, at least 24 in. above the floor; service clearances in fig. 2
Dimensions W × H × D10 1/8 × 20 7/8 × 7 1/8 in.11.5 × 21.5 × 6.75 in.published L × W × H: 11.5 × 6.75 × 21.5 in.
Humidifier, weight23 lb empty, 27 lb operating15 lb empty, 20 lb full
Stated ambient rangeNot below freezing, not above 60 °C (140 °F)5 to 40 °C, 5 to 95 % RH
Features

What each manufacturer writes, line by line

Wall control supplied

AprilAire: Model 62 automatic digital control with outdoor sensor, setting 10 to 45 % or off, accuracy ±3 %.

Resideo: HumidiPRO H6062 humidistat supplied in the box.

AprilAireResideo
Blower operation

AprilAire: the control can run the blower to humidify while the furnace is idle (blower activation).

Resideo: no steam until the fan safety loop is closed; optional 50027910-001 air-proving switch, advised on every installation.

AprilAireResideo
Automatic drain

AprilAire: drain cycle of about 4 minutes; cold inlet water tempers the drain water.

Resideo: automatic drains keep the conductivity in range; water cooled to 60 °C.

AprilAireResideo
Cylinder upkeep

AprilAire: canister replaced, not cleaned; yearly care of the O-ring, drain valve and screen; electrode wires every 3 years.

Resideo: clean the drain valve at every cylinder change; only the HM700ACYL2 is approved.

AprilAireResideo
Start-up

AprilAire: it can take several days to reach rated output, depending on the water.

Resideo: 5 to 10 minutes to boil; with low-conductivity water, full output can take several hours.

AprilAireResideo
During cooling

AprilAire: running during cooling calls is not advised, because of condensation risk; lockout advised.

Resideo: if condensation appears, check supply air temperature and humidity (troubleshooting, p. 21).

AprilAireResideo
FAQ

Questions about these two humidifiers

Which one makes more steam?

It depends on the wiring. At 240 V, the AprilAire 800 publishes 23.3 gal/day at 11.5 A and 34.6 gal/day at 16 A; the HM700 publishes 22 gal/day. At 120 V, 11.5 or 16 gal/day against 11 gal/day. The selector at the top of the page gives each case, in litres too.

And at 208 V, common in many buildings?

AprilAire publishes 20.5 gal/day at 11.5 A and 30 gal/day at 16 A at 208 V. Resideo's HM700 document gives its values at 110/120 V and 220/240 V; it does not put a number on output at 208 V.

What size of house?

The two manufacturers do not measure the same way. AprilAire gives an area in sq ft for a tight, average or loose house with 8 ft ceilings: at 208 or 240 V and 16 A, up to 4,000 sq ft for an average house. Resideo asks for a calculation in cu ft and refers to the AHRI table: for 32,000 cu ft of average construction, 33 gal/day, which is two HM700 units at 240 V. The two tables do not compare line by line.

My water is softened: is that a problem?

AprilAire accepts softened water with the Model 80 canister, not with the 80LC. Resideo's HM700 document does not mention it; it requires water between 150 and 1,200 µS/cm and rules out demineralized and reverse-osmosis water.

Do these units work with a heat pump?

Neither document mentions heat pumps. AprilAire's manual asks that the absorption distance in the duct be based on the lowest temperature expected in that duct (p. 8). Its Table 3 gives, at 300 fpm and for 25 to 35 gal/day, 31 in. at 21 °C (70 °F) and 45 % humidity, against 60 in. at 7 °C (45 °F) and 45 %. Our steam versus evaporative comparison comes back to duct temperature.

Is the HM700 still made?

Resideo's documents for the HM700A1000 carry the note “legacy product… no longer manufactured”. AirGreen lists it on its site; ask our team about the availability of the unit and of HM700ACYL2 cylinders. Document checked November 10, 2026.

Why not compare the warranties?

Our comparisons do not compare warranties. Each manufacturer's warranty documents come with the quote.

Full spec sheet

Every published value, in one place

ValueAPRILAIRE 800HONEYWELL HM700
Published steam output
Steam output at 120 V11.5 gal/day at 11.5 A; 16 gal/day at 16 A11 gal/day (110/120 V)
Steam output at 208 V20.5 gal/day at 11.5 A; 30 gal/day at 16 ANot published by the manufacturer at 208 V
Steam output at 240 V23.3 gal/day at 11.5 A; 34.6 gal/day at 16 A22 gal/day (220/240 V)7.7 lb/h (3.5 kg/h), Table 6
Electrical
Power at 240 V2.8 kW at 11.5 A; 3.8 kW at 16 A2.8 kWthe wiring label on p. 2 shows 2.9 kW
Power at 120 V1.4 kW at 11.5 A; 1.9 kW at 16 A1.4 kW
Current11.5 or 16 A11.5 A ±10 %; size the circuit for 12.7 A12 A
Cylinder and control
Electrode cylinderModel 80 or 80LC depending on the waterHM700ACYL2
Humidistat suppliedModel 62, with outdoor sensorHumidiPRO H6062
Size
Dimensions W × H × D10 1/8 × 20 7/8 × 7 1/8 in.11.5 × 21.5 × 6.75 in.
Humidifier, weight23 lb empty, 27 lb operating15 lb empty, 20 lb full
Status with the manufacturerSpec sheet dated January 2026 (form 251, 01.26)Document marked “legacy product, no longer manufactured” by Resideo

US gallons. Values per the manufacturers' documents, cited below; none is certified by a third party the way heat pumps are.

Both are on AirGreen's site.

To choose, talk with our team: bring your panel voltage, the duct location and the distance to a drain.

Sources