Home / Comparisons / 24,000 BTU ceiling cassettes
FUJITSU AIRSTAGE CENTAURI and MIDEA: two 24,000 BTU cassettes, from the ceiling to the yard
Two large cassettes for an open area or a commercial space, each certified as a single-zone system with its own outdoor unit. What sets them apart shows mostly in between: the piping, the refrigerant, the charge already in the unit. This page also compares the fan, the NEEP certified values and what the electricity costs.
To scale: the dark part is the length already charged at the factory, the pale part runs to the published maximum.
CENTAURI large cassette 24,000 BTU
AUUH24KUAS / AOUH24KUAS1 · AHRI 215434553
The same cassette is also certified with the AOUH24KUAH1 outdoor unit (AHRI 218814798): same SEER2, HSPF2 Region V of 8.7. That is not the system compared here.
View the product page
4-way cassette 24,000 BTU
MCDHU-H24B-2A / MO1HS-H24B-2A · AHRI 215471398
The same cassette is also certified with the MO1ES-H24B-2A outdoor unit (AHRI 215471392): SEER2 22, HSPF2 Region V of 8.1. That is not the system compared here.
View the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 24,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. The AHRI certificates give the FUJITSU AIRSTAGE 24,000 BTU/h of rated cooling and the MIDEA 23,400; the same 24,000 BTU/h zone is used here for both. Electric baseboards serve as the point of reference.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 24,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 24,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.
Up to 66 ft with nothing added on one side, 25 ft on the other
Both manufacturers publish the same maximum length, 164 ft. The difference is in the refrigerant charge put in at the factory: FUJITSU AIRSTAGE plans it for 66 ft, MIDEA for 25 ft. Beyond that, the technician adds refrigerant, at a published rate per foot. Move the slider to place the outdoor unit closer or farther.
Diagram. The lengths, add rates and maximums are those of the submittals; the charge to add is calculated here from those rates. The actual amount is set by the installer, according to the route and the installation manual.
| The line set | CENTAURI large cassette | 4-way cassette |
|---|---|---|
| Maximum piping length | 164 ftMinimum 16 ft | 164 ftMinimum not published in the submittal read |
| Precharged length | 66 ft0.22 oz/ft added beyond | 25 ft0.32 oz/ft added beyond |
| Maximum height difference | 98 ft | 82 ft |
| Liquid – gas diameters | 1/4 – 1/2 in | 3/8 – 5/8 in |
| RefrigerantGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2L | R-454B · GWP 466 · A2L |
FUJITSU AIRSTAGE: submittal of the 24KUAS1U system (AUUH24KUAS / AOUH24KUAS1), version 20250409A. MIDEA: submittal of the “4-Way Cassette Xtreme Heat” series MCDHU-H24B-2A / MO1HS-H24B-2A. Diameters are those of the published connections.
Four published speeds on one side, five on the other
FUJITSU AIRSTAGE publishes four speeds, from 512 to 677 CFM. MIDEA publishes five, from 547 to 765 CFM, and two of them carry the same values. Each bar gives the airflow and the sound pressure the manufacturer pairs with that speed.
CENTAURI large cassette
4-way cassette
Same scale for both, from 0 to 765 CFM. FUJITSU AIRSTAGE: submittal 24KUAS1U (20250409A). MIDEA: submittal MCDHU-H24B-2A / MO1HS-H24B-2A; MIDEA also mentions a fan setting from 1 to 100 %, with no airflow attached. Neither manufacturer describes its sound test conditions: the “Sound” section below explains this.
Below −15 °C: every published number, at its exact temperature
At −15 °C, NEEP certifies both at the same point: 23,600 BTU/h for the FUJITSU AIRSTAGE, 23,800 BTU/h for the MIDEA, at maximum. Lower down, their last certified points are not at the same temperature: −20.6 °C for the FUJITSU AIRSTAGE, −30 °C for the MIDEA.
What each manufacturer writes, group by group
FUJITSU AIRSTAGE: submittal of the 24KUAS1U system. MIDEA: submittal of the “4-Way Cassette Xtreme Heat” series. A feature missing from a document is not necessarily missing from the unit.
CENTAURI : circular-flow outlet, all around the grille.
MIDEA : 360° outlet.
CENTAURI : four speeds (high, medium, low, quiet) and auto.
MIDEA : five published speeds, from silent to turbo; setting from 1 to 100 %.
CENTAURI : built-in drain pump.
MIDEA : built-in pump.
CENTAURI : optional occupancy sensor (UTY-SHZXC).
MIDEA : humidity sensor; optional refrigerant leak sensor.
CENTAURI : optional Wi-Fi (UTY-TFSXJ4); BACnet and Modbus gateways.
MIDEA : Wi-Fi dongle or wired controller with Wi-Fi; 24 V thermostat interface.
CENTAURI : optional fresh air kit (UTZ-VXRA); outlet shutter plate (UTR-YDZK); white or black grille.
MIDEA : not stated by the manufacturer in the submittal read.
What each manufacturer publishes, read separately
FUJITSU AIRSTAGE publishes four sound pressure levels for the cassette, MIDEA publishes five. Neither of the documents read describes the distance or the test room.
How to read these numbers. dB(A) measures a noise level the way the ear perceives it: the lower the number, the quieter the unit. Each dot is a published fan speed, from slowest to fastest.
Why this is not a ranking. The test conditions are not published, and the airflows are not the same at each speed: 677 CFM at the FUJITSU AIRSTAGE’s highest, 765 at the MIDEA’s turbo. Moving more air generally makes more noise.
Cassette, in the room
Every published speed
Outdoor unit, outside
Published values
Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.
The cassette in the ceiling, the unit outside, the electrical panel
Both cassettes, photos at the same width scale


Three-quarter photos taken from AirGreen’s product cards: the dimension line gives the indoor unit’s published width in each submittal. Neither submittal read says whether this is the cabinet or the grille.
| Installation | CENTAURI large cassette | 4-way cassette |
|---|---|---|
| Indoor unit, published dimensions | 33 1/16 × 33 1/16 × 9 11/16 in840 × 840 × 246 mm | 32 5/8 × 32 5/8 × 8 1/8 in830 × 830 × 205 mm |
| Indoor unit, weight | 53 lb | 47 lb |
| Outdoor unit, dimensions and weight | 37 × 31 × 12 5/8 in, 115 lbWidth × height × depth | 37 1/4 × 31 7/8 × 16 1/8 in, 130 lbWidth × height × depth |
| Electrical protectionAccording to the manufacturer | 20 A maximum breaker (MCA 15.9 A) | MOCP 25 A (MCA 24.9 A) |
| Dehumidification | 2.9 L/h6.1 pints/h per the submittal | 2.36 L/h |
| Advertised heating / cooling range | −21 to 24 °C / −21 to 50 °C | Heating NEEP certified down to −30 °CSubmittal ranges to be confirmed with MIDEA |
FUJITSU AIRSTAGE: submittal 24KUAS1U, version 20250409A; the outdoor unit is published as 31 × 37 × 12 5/8 in (height × width × depth). MIDEA: submittal MCDHU-H24B-2A / MO1HS-H24B-2A; outdoor unit published as 37 1/4 × 16 1/8 × 31 7/8 in (width × depth × height). Breaker and wire size are confirmed with the nameplate and the code in force.
What people ask about these two cassettes
What does “precharged for 66 ft” mean?
The outdoor unit leaves the factory with enough refrigerant for a line set of that length. According to the submittals, the FUJITSU AIRSTAGE is charged for 66 ft and the MIDEA for 25 ft; beyond that, the installer adds 0.22 oz/ft of R-32 or 0.32 oz/ft of R-454B.
Why two different refrigerants?
The FUJITSU AIRSTAGE uses R-32 (GWP of 675 per the IPCC, AR4), the MIDEA R-454B (GWP of 466). Both are classed A2L, mildly flammable, in the ASHRAE 34 standard. The installer works with the tools and cylinders specific to each.
Which one heats more at −15 °C?
According to NEEP, 23,600 BTU/h maximum for the FUJITSU AIRSTAGE and 23,800 BTU/h for the MIDEA, with COPs of 2.12 and 2.23. It is the lowest temperature at which both are measured under the same conditions.
Why is one measured at −20.6 °C and the other at −30 °C?
Each manufacturer has its system measured at its own coldest point: −5 °F (−20.6 °C) for FUJITSU AIRSTAGE, −22 °F (−30 °C) for MIDEA. The 21,000 BTU/h of one and the 9,500 BTU/h of the other are therefore not directly comparable.
Why 24,000 BTU on one side and 23,400 on the other?
These are the AHRI certified rated cooling capacities at 35 °C. Both are sold as 24,000 BTU units; the estimated cost above uses the same 24,000 BTU/h zone for both.
Does one need a bigger breaker?
According to the submittals, the FUJITSU AIRSTAGE calls for a 20 A maximum breaker (MCA 15.9 A) and the MIDEA a 25 A protection (MCA 24.9 A). Free space in the panel is checked during the visit.
Are they eligible for grants?
Eligibility depends on the official list in effect on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.
All AHRI and NEEP values
| Certified value | CENTAURI large cassette | 4-way cassette |
|---|---|---|
| Cooling | ||
| Rated capacity at 35 °CBTU/h | 24,000 | 23,400 |
| SEER2 | 23.2 | 20.7 |
| EER2 | 13.1 | 12.0 |
| Heating, same conditions | ||
| HSPF2 Region IV / V | 11.0 / 8.5 | 11.6 / 9.2 |
| 8.3 °C: min. / rated / max.BTU/h | 5,400 / 27,000 / 32,000 | 11,500 / 25,000 / 30,700 |
| 8.3 °C: COP at min., rated, max. | 3.52 / 3.90 / 3.23 | 4.88 / 3.54 / 3.61 |
| −8.3 °C: min. / rated / max.BTU/h | 6,400 / 17,800 / 26,000 | 9,100 / 20,400 / 23,900 |
| −8.3 °C: COP at min., rated, max. | 5.07 / 3.22 / 2.41 | 2.47 / 2.78 / 2.48 |
| −15 °C: min. / rated / max.BTU/h | 5,900 / 23,600 / 23,600 | 7,200 / 23,800 / 23,800 |
| −15 °C: COP at min., rated, max. | 4.80 / 2.12 / 2.12 | 2.07 / 2.23 / 2.23 |
| Coldest point — different temperatures, not highlighted | ||
| Test temperature | −20.6 °C (−5 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 5,500 / 21,000 BTU/h | 3,800 / 9,500 BTU/h |
| COP at maximum output | 1.89 | 1.16 |
| Certifications and refrigerant | ||
| ENERGY STAR / cold climate (NEEP) | Yes / Yes | Yes / Yes |
| Certificate type (NEEP) | Single-zone, non-ducted, ceiling | Single-zone, non-ducted, ceiling |
| AHRI certificate · NEEP record | 215434553 · 388260 | 215471398 · 387341 |
| RefrigerantGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2L | R-454B · GWP 466 · A2L |
higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted: the order changes depending on the point.
Both are on the AirGreen website.
To choose for your space, talk to our team: bring the type of ceiling, the free height above it, the distance to the planned outdoor location and the free space in the electrical panel.
Where each number comes from
Data verified on November 10, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, airflows, sound, piping and features: according to the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.