SAMSUNG WindFree 4-way cassette and GREE ALL MATCH 360 cassette, 12,000 BTU

Home / Comparisons / 12,000 BTU ceiling cassettes

Comparison · Ceiling cassette · 12,000 BTU

SAMSUNG WindFree and GREE ALL MATCH 360: two 12,000 BTU cassettes, seen from below

A cassette hides above the ceiling; from the room, all you see is its panel. These two have almost the same square, about 620 mm a side, and panels that deliver air in very different ways. Each is certified as a single-zone system with its own outdoor unit. This page compares the panel, the fan, the certified values and what the electricity costs.

Panel : 619 mm and 620 mmFan speeds : 3 and 7SEER2 22 and 23HSPF2 Region V 8.3 and 8
SAMSUNG · 619 mmGREE · 620 mm 4 louvers360°

Drawing, to scale: both panels seen from below, published side length.

SAMSUNG WindFree 4-way cassette 12,000 BTU (AirGreen image)
SAMSUNG

WindFree 4-way cassette 12,000 BTU

AC012DNNDCG / AC012DXSCCG · AHRI 216441747

Also sold as LENNOX M22D (M22D012S6-1P / MMLD012S6S-1P, AHRI 216581327): same NEEP certified values.

View the product page
GREE ALL MATCH 360 cassette 12,000 BTU (AirGreen image)
GREE

ALL MATCH 360 cassette 12,000 BTU

CAS12HP230V1R32AH / VIR12HP230V1R32AO · AHRI 215415563

The GREE CLIVIA 8-way cassette (AHRI 216618212) carries the same NEEP certified values, except the rated COP at −8.3 °C. The same cassette is also certified with the SAPPHIRE and ENVO outdoor units, same SEER2 and HSPF2.

View the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.

Seen from below

The same square in the ceiling, two ways of blowing air

From the room, a cassette comes down to its panel. SAMSUNG publishes one 24 3/8 in a side, GREE one 24 13/32 in: 1 mm apart. What changes is how the air comes out. Pick a mode: both panels are drawn to scale in a 2 × 2 ft ceiling grid.

WindFree 4-way cassette SAMSUNG

ALL MATCH 360 cassette GREE

Drawing, to scale (8 px per inch). The grey lines are a 2 × 2 ft ceiling grid at its nominal 24 in pitch. The arrows show the outlet directions each manufacturer describes, not a measurement of air speed.

In the ceilingWindFree 4-way cassetteALL MATCH 360 cassette
Panel, width × depth × thickness24 3/8 × 24 3/8 × 2 3/8 in619 × 619 × 60 mm; PC4SUFMUNW panel, 6 lb24 13/32 × 24 13/32 × 1 7/8 in620 × 620 × 48 mm; GREETF05 grille, 6.6 lb
Cabinet, width × depth × height22 5/8 × 22 5/8 × 9 13/16 in575 × 575 × 249 mm22 7/16 × 22 7/16 × 10 7/16 in570 × 570 × 265 mm
2 × 2 ft ceiling gridPanel designed to fit a standard 2 × 2 ft grid without interfering with adjacent tiles, per SAMSUNG HVACNot published by the manufacturerThe documents read give the dimensions, not grid compatibility
Airflow direction4 motorized louvers; WindFree mode: louvers closed, air dispersed through thousands of micro-holes, under 0.15 m/s360° outlet; automatic vertical swingAutomatic horizontal swing: no, per the submittal

SAMSUNG: submittal AC012DNNDCG/AA, version 01012025A, and the SAMSUNG HVAC product page of the WindFree Mini 4-Way Cassette. GREE: submittal GREE_CAS12HP_230V_R32_SUB_03172025 and brochure GREE_360°_CASSETTE_ALL_MATCH_R32_031725.

Above the ceiling, 16 mm apart. The SAMSUNG cabinet is 249 mm high, the GREE one 265 mm. Below the ceiling, the SAMSUNG panel is thicker: 60 mm against 48 mm. The depth to plan for is confirmed on site with the installation manual of the unit chosen.
The fan, speed by speed

Three speeds on one side, seven on the other

SAMSUNG publishes three speeds, from 226 to 325 CFM. GREE publishes seven, from 206 to 330 CFM. The end points are close; GREE adds steps in between. Each bar gives the airflow and the sound pressure the manufacturer pairs with that speed.

WindFree 4-way cassette

Low226 CFM 25 dB(A)
Medium283 CFM 30 dB(A)
High325 CFM 34 dB(A)

ALL MATCH 360 cassette

Speed 1206 CFM 29 dB(A)
Speed 2224 CFM 31 dB(A)
Speed 3247 CFM 33 dB(A)
Speed 4265 CFM 34 dB(A)
Speed 5288 CFM 36 dB(A)
Speed 6318 CFM 39 dB(A)
Speed 7330 CFM 40 dB(A)

Same scale for both, from 0 to 330 CFM. SAMSUNG: submittal AC012DNNDCG/AA (01012025A), cooling and heating identical. GREE: service manual ALL-MATCH INVERTER SERIES_R32, 9K to 24K cassettes, which does not name the speeds. The two manufacturers do not describe their sound test conditions the same way: the “Sound” section below explains this.

Extreme cold

Below −15 °C: every published number, at its exact temperature

At −15 °C, NEEP certifies both at the same point: 11,200 BTU/h for the SAMSUNG, 10,000 BTU/h for the GREE, at maximum. Lower down, their last certified points are not at the same temperature: −25 °C for the SAMSUNG, −30 °C for the GREE.

What each manufacturer publishes below −15 °C. SAMSUNG: the AC012DXSCCG outdoor unit submittal states high heating capacity at −20 °C (−4 °F), without a figure, and a heating range down to −25 °C (−13 °F); the NEEP point at −25 °C is the last published number. GREE: the submittal lists heating from −30 to 30 °C (−22 to 86 °F) and gives capacity at 47, 17 and 5 °F; the NEEP point at −30 °C is the only published number lower down.
Documented features

What each manufacturer writes, group by group

SAMSUNG: submittal AC012DNNDCG/AA and the AC012DXSCCG outdoor unit submittal. GREE: submittal GREE_CAS12HP_230V_R32_SUB_03172025 and the 360 cassette brochure.

Louvers and air delivery

WindFree : motorized louvers; WindFree mode that closes the louvers in cooling and disperses air through micro-holes, under 0.15 m/s.

ALL MATCH 360 : 360° outlet; automatic vertical swing.

Fan

WindFree : three speeds and auto; turbo fan with a BLDC motor.

ALL MATCH 360 : centrifugal fan, seven speeds; quiet mode.

Condensate pump

WindFree : built-in pump, 29 in maximum lift, check valve and float switch that shuts the unit off on overflow.

ALL MATCH 360 : float switch, per the brochure; lift height not published in the documents read.

Controls and Wi-Fi

WindFree : Wi-Fi adapter built into the panel, SmartThings app; wired or wireless controllers sold separately.

ALL MATCH 360 : XE72-44/E wired controller and wireless remote included; Wi-Fi included: no, per the submittal.

Refrigerant sensor

WindFree : built-in R-32 leak detection; alarm output with the MIM-B14U accessory.

ALL MATCH 360 : refrigerant sensor, per the brochure.

Modes

WindFree : dual set temperature with compatible controllers; control of an external backup heat source with the MIM-B14U.

ALL MATCH 360 : Turbo, Sleep, I Feel, X-Fan, Freeze Guard, energy saving, timer.

Filter and fresh air

WindFree : washable filter; knock-out for an outside-air connection.

ALL MATCH 360 : outdoor-air ventilation: no, per the submittal; dirty filter alert: no.

Defrost and restart

WindFree : auto-restart after a power loss; fan operation adjustable during defrost.

ALL MATCH 360 : “intelligent” defrosting, preheating, power failure recovery.

Outdoor unit base pan

WindFree : base pan heater as standard; option that keeps snow from drifting against an idle unit.

ALL MATCH 360 : base pan with electric heater; anti-corrosion coated fins.

Sound

What each manufacturer publishes, read separately

SAMSUNG publishes three sound pressure levels for the cassette, GREE publishes seven. Neither of the documents read describes the distance or the test room.

dB(A)

How to read these numbers. dB(A) measures a noise level the way the ear perceives it: the lower the number, the quieter the unit. Each dot is a published fan speed, from slowest to fastest.

Why this is not a ranking. The test conditions are not published, and the airflows are not the same at each speed: 226 CFM at the SAMSUNG’s lowest, 206 at the GREE’s lowest. In the ceiling, what you hear also depends on the height and the room.

Cassette, in the room

Every published speed

Outdoor unit, outside

Published value

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Installation

The cassette in the ceiling, the unit outside, the piping in between

Both cassettes, photos at the same width scale

WindFree 4-way cassette24 3/8 in panel
AC012DNNDCG cassette with its panel
panel 24 3/8 in · 619 mm
ALL MATCH 360 cassette24 13/32 in panel
CAS12HP230V1R32AH cassette with its grille
panel 24 13/32 in · 620 mm

Three-quarter photos taken from AirGreen’s product cards: the dimension line gives each panel’s published width. The drawing under “Seen from below” is to scale.

InstallationWindFree 4-way cassetteALL MATCH 360 cassette
Maximum piping length66 ft66 ftMinimum 10 ft
Precharged length24.6 ft0.161 oz/ft added beyond25 ft0.2 oz/ft added beyond
Maximum height difference49 ft40 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 inOutdoor unit flare connections: 1/4 – 1/2 in
Outdoor unit W × H × D, weight31 1/8 × 21 5/8 × 11 3/16 in, 67.2 lb31 37/64 × 21 27/32 × 13 25/32 in, 67.3 lb
Indoor unit, weight with panel31.4 lbCabinet 25.4 lb and panel 6 lb44.1 lbCabinet 37.5 lb and grille 6.6 lb
Electrical protectionAccording to the manufacturer15 A maximum breaker (MCA 13.9 A)MOCP 15 A (MCA 10 A)
Condensate pump, lift29 in maximum, from the bottom of the unitNot published by the manufacturer
DehumidificationNot published by the manufacturer1.4 L/h2.96 pints/h per the submittal, converted
Advertised heating / cooling range−25 to 24 °C / −5 to 50 °CCooling down to −18 °C with a baffle−30 to 30 °C / −29 to 50 °C

SAMSUNG: AC012DXSCCG/AA outdoor unit submittal (version 02132025A, published with the AC012DNHDCG Duct S indoor unit; outdoor and piping values are the outdoor unit’s) and AC012DNNDCG/AA submittal (01012025A). GREE: submittal GREE_CAS12HP_230V_R32_SUB_03172025, values with the VIR12HP230V1R32AO outdoor unit; ranges published in °F: −22 to 86 °F and −20 to 122 °F.

Frequently asked questions

What people ask about these two cassettes

Do they fit a 2 × 2 ft suspended ceiling?

SAMSUNG HVAC writes that the WindFree Mini 4-Way Cassette panel is designed to fit a standard 2 × 2 ft grid without interfering with adjacent tiles. GREE publishes a 24 13/32 in grille and a 22 7/16 in cabinet, without mentioning a ceiling grid. Compatibility with your grid is checked on site.

What is WindFree mode?

According to SAMSUNG, in cooling, WindFree mode closes the louvers and sends the air through thousands of micro-holes in the panel, at under 0.15 m/s, which ASHRAE calls “still air”. The mode is turned on from a controller. GREE publishes no comparable mode for the 360 cassette.

Which one heats more at −15 °C?

According to NEEP, 11,200 BTU/h maximum for the SAMSUNG and 10,000 BTU/h for the GREE, with COPs of 1.79 and 1.90. It is the lowest temperature at which both are measured under the same conditions.

Why is one measured at −25 °C and the other at −30 °C?

Each manufacturer has its system measured at the bottom of its advertised range: −13 °F (−25 °C) for SAMSUNG, −22 °F (−30 °C) for GREE. The SAMSUNG’s 7,000 BTU/h at −25 °C and the GREE’s 6,500 BTU/h at −30 °C are therefore not directly comparable.

Seven speeds against three: what does it change?

The end points are close: 226 to 325 CFM for the SAMSUNG, 206 to 330 CFM for the GREE. The GREE’s seven speeds give intermediate steps; the SAMSUNG’s three come with the auto setting and WindFree mode.

Do they go by other names?

The NEEP record of the LENNOX M22D 12,000 BTU (AHRI 216581327) carries the same certified values as the SAMSUNG WindFree. For GREE, the CLIVIA 8-way cassette (AHRI 216618212) has the same NEEP certified values as the ALL MATCH 360 cassette, except the rated COP at −8.3 °C (1.99 against 2.79).

Are they eligible for grants?

Eligibility depends on the official list in effect on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.

Certified data

All AHRI and NEEP values

Certified valueWindFree 4-way cassetteALL MATCH 360 cassette
Cooling
35 °C: min. / rated / max.BTU/h3,500 / 12,000 / 15,0002,700 / 12,000 / 16,000
SEER222.023.0
EER212.613.0
Heating, same conditions
HSPF2 Region IV / V10.4 / 8.39.0 / 8.0
8.3 °C: min. / rated / max.BTU/h3,000 / 14,000 / 16,0003,070 / 12,000 / 14,000
8.3 °C: COP at min., rated, max.5.86 / 3.80 / 2.615.29 / 3.78 / 3.57
−8.3 °C: min. / rated / max.BTU/h5,800 / 10,700 / 14,9002,700 / 10,000 / 12,000
−8.3 °C: COP at min., rated, max.2.62 / 2.61 / 2.513.04 / 2.79 / 2.17
−15 °C: min. / rated / max.BTU/h5,200 / 11,200 / 11,2002,600 / 10,000 / 10,000
−15 °C: COP at min., rated, max.1.79 / 1.80 / 1.792.54 / 1.90 / 1.90
Coldest point — different temperatures, not highlighted
Test temperature−25 °C (−13 °F)−30 °C (−22 °F)
Capacity min. / max.3,300 / 7,000 BTU/h2,000 / 6,500 BTU/h
COP at maximum output1.921.42
Certifications and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
Certificate type (NEEP)Single-zone, non-ducted, ceilingSingle-zone, non-ducted, ceiling
AHRI certificate · NEEP record216441747 · 406919215415563 · 388978
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-32 · GWP 675 · A2L

higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted: the order changes depending on the point.

Both are on the AirGreen website.

To choose for your room, talk to our team: bring the type of ceiling, the free height above it and the planned outdoor location.

Sources and documents

Where each number comes from