GREE FREEMATCH R32, 2 to 5 zones

Home / Comparisons / Multi-zone, 2 to 5 zones

Comparison · One family · 2 to 5 zones

GREE FREEMATCH R32: 2 to 5 zones, on the same principle

One family, five outdoor units, from 18,000 to 42,000 BTU/h. Each size accepts a different number of heads, has its own AHRI certificate and its own combination table. This page shows what changes when a room is added: the outdoor unit, the certified values and the sets GREE provides for.

SEER2 21 for all five sizesHSPF2 IV / V 10 / 8 for all five2 to 5 heads

Also sold as GREE MULTI R32 (MUL18HP230V1R32AO to MUL42HP230V1R32AO): same AHRI and NEEP certified values, size for size, with separate certificates.

GREE FREEMATCH R32, 2 zones (AirGreen image)
GREE

FREEMATCH R32 · 2 zones, 18,000 BTU

GWHD(18)ND6MO + non-ducted indoor units · AHRI 214931586

See the product page
GREE FREEMATCH R32, 5 zones (AirGreen image)
GREE

FREEMATCH R32 · 5 zones, 42,000 BTU

GWHD(42)ND6MO + non-ducted indoor units · AHRI 214931590

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 36,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point. All five FREEMATCH R32 sizes have the same SEER2 (21) and the same HSPF2 Region V (8) with wall-mounted heads, so the amount changes mainly with the size. This calculation takes the 36,000 BTU/h unit and compares its two certificates, wall-mounted heads (non-ducted) and ducted heads. With ducted heads, the certificate states 32,000 BTU/h in cooling at 35 °C: the calculation uses the common nominal size, 36,000 BTU/h.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 36,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 36,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Add a head

Pick an outdoor unit, then add the heads one by one

Each size has its own combination table, published by GREE: the sets of heads allowed and the capacity each head receives. Add heads, in thousands of BTU/h; the page checks the set against the table of the chosen unit and shows the connected total against its size.

Outdoor unit

Add a head

Heads chosen (tap a head to remove it)

Total connected: 33,000 BTU/h

“Allowable combinations capacities” tables from the GREE Canada submittals Multi-R32-GWHD(18)ND6MO to GWHD(42)ND6MO-Submittal (March 2025). Capacities per head in BTU/h, with non-ducted heads. GREE states that a 5,000 or 7,000 BTU/h wall unit may replace a 9,000 head, with capacities published in a separate table. The 36,000 table also includes a 21,000 BTU/h head (21 + 24 and 9 + 21 + 24). The heads sold and their layout are confirmed with the quote.

Five sizes

What changes from one outdoor unit to the next

The five units have the same SEER2 and the same HSPF2 with wall-mounted heads. What changes: the number of heads, the certified capacity, the capacity in extreme cold, the allowed piping, the cabinet and the electrical connection. Each bar uses the same scale for all five sizes.

Certified values: AHRI certificates published by NEEP, non-ducted heads. Piping, weight, electrical and sound: GREE Canada submittals (March 2025) for the first four sizes; FREEMATCH R32 brochure X610068B (May 2025) for the 42,000 and for the total piping of the 30,000.

Extreme cold

Below −15 °C: what GREE publishes, at its exact temperature

NEEP certifies each size at −15 °C and at −30 °C. The chart shows the 36,000 BTU/h unit with its two certificates: wall-mounted heads and ducted heads. Between −15 and −30 °C, no point is published: the page shows the range between the two values, with nothing calculated between them.

The five sizes at −30 °C, maximum capacity certified by NEEP (non-ducted heads). 18,000: 10,200 BTU/h (COP 1.51) · 24,000: 17,400 BTU/h (COP 1.50) · 30,000: 21,000 BTU/h (COP 1.45) · 36,000: 26,200 BTU/h (COP 1.51) · 42,000: 28,400 BTU/h (COP 1.50). The heating range GREE publishes runs from −22 to 75 °F (−30 to 24 °C) for all five sizes: −30 °C is its lower end.
Documented features

What GREE writes for all five sizes

GREE Canada submittals, FREEMATCH R32 brochure X610068B and the product page at GREE Canada. These documents describe the outdoor unit: several comfort features depend on the head chosen.

Extreme cold

All five sizes: heating listed from −22 to 75 °F (−30 to 24 °C).

Cooling in cold weather

All five sizes: cooling listed from −22 to 118 °F; “Low Ambient Cooling” stated.

Base pan heater

All five sizes: base pan heater as standard (“Chassis With Electric Heater”); 96 W on the 30,000 and 36,000.

Power to the heads

All five sizes: the indoor units are powered by the outdoor unit, according to brochure X610068B.

Leak detection

All five sizes: A2L refrigerant leak sensor included, according to brochure X610068B.

Defrost

All five sizes: intelligent defrost.

Restart after a power outage

All five sizes: “Auto Restart”.

Electrical protection

All five sizes: low-voltage start-up; wide voltage range; self-diagnosis.

Number of indoor units

By size: two for the 18,000, three for the 24,000, four for the 30,000 and 36,000, five for the 42,000.

Sound

How loud each outdoor unit is, according to GREE

Outside, a single unit serves all the rooms: this is the figure that matters for the neighbours. It rises with the size. Inside, the sound depends on each head chosen; its sheet comes with the quote.

dB(A)

How to read these figures. The dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is the sound pressure GREE publishes for one size.

What to keep in mind. GREE publishes a single value per unit, without stating the measuring distance. The five values come from the same manufacturer and the same documents: read them against each other, not against another brand’s.

Outdoor unit, outside

Published sound pressure, one value per size

One value per size, published by GREE: from 54 dB(A) for the 18,000 to 63 dB(A) for the 36,000 and 42,000.

Sources: GREE Canada submittals GWHD(18) to GWHD(36)ND6MO (March 2025) and brochure X610068B for the GWHD(42)ND6MO.

Installation

Three cabinets, one way of connecting

Outdoor units, at the same scale

32 23/64 × 21 42/64 in
13 55/64 in · 75 lb

37 61/64 × 25 63/64 in
15 53/64 in · 112.5 lb

40 10/64 × 32 33/64 in
16 52/64 in · 145.5 to 176.4 lb

Diagram: published width and height, at the same scale; depth and weight below. GREE Canada submittals; weight of the 42,000: 79 kg according to brochure X610068B.

What stays the same from one size to the next

  • One line per head. Each indoor unit has its own pair of pipes to the outdoor unit, 1/4 – 3/8 in. GREE states that the line is sized to the head’s connection.
  • Refrigerant to add. 0.2 oz per foot beyond each size’s pre-charged length.
  • Power to the heads. The indoor units are powered by the outdoor unit, according to brochure X610068B.
  • R-32 refrigerant. GREE states that R-32 heads connect only to an R-32 outdoor unit.

Lengths, height differences and electrical data for each size: see “Five sizes”. The location of the unit and the line routing are decided during the assessment visit.

Clearances around the outdoor unit: figures in the installation manuals, not reproduced on this page.

Questions

What people ask us about the FREEMATCH R32 family

FREEMATCH R32 or MULTI R32: is it the same family?

The GWHD(18)ND6MO to GWHD(42)ND6MO units are called FREEMATCH R32 in GREE brochure X610068B and Multi R32 in GREE Canada’s submittals. AirGreen also offers the GREE MULTI R32 under model numbers MUL18HP230V1R32AO to MUL42HP230V1R32AO: its AHRI certificates are separate (215218913 to 215218917), and NEEP publishes the same certified values for them, size for size.

Why does each head get less when more are added?

Because the outdoor unit shares its capacity. GREE’s table puts figures on it: on the 24,000, three 9,000 heads receive 8,000 BTU/h each; on the 42,000, five 9,000 heads receive 8,400 BTU/h each. The Add a head builder shows these values for every set in the table.

Can you connect more than the size of the outdoor unit?

Yes, within the sets the table provides for. They go up to 150% of the nominal size (133% for the 18,000), but the unit does not produce more: its capacity is shared among the heads, as the table shows.

Do the five sizes have the same efficiency?

With wall-mounted heads, yes for seasonal efficiency: SEER2 21 and HSPF2 10 in Region IV, 8 in Region V, on all five certificates. EER2, measured at 35 °C, ranges from 12 to 13.6.

Does the certificate change with ducted units?

Yes. A multi-zone AHRI certificate covers a set: one outdoor unit and one type of indoor unit. For the 36,000, the ducted certificate (214931595) states SEER2 18 and HSPF2 8.1 / 7; in a mixed combination (214931599), SEER2 19 and HSPF2 9 / 7.4.

How many rooms can one unit heat?

Two to five, depending on the size: two for the 18,000, three for the 24,000, four for the 30,000 and 36,000, five for the 42,000. The number of rooms is not enough to choose: the heat loss of each room and the combination table decide.

Certified data

The 36,000 BTU/h unit: its two certificates, every value

Certified valueWall-mounted headsDucted heads
Cooling
Rated capacity at 35 °C36,000 BTU/h32,000 BTU/h
35 °C: min. / rated / max.BTU/h8,870 / 36,000 / 38,0008,870 / 32,000 / 38,000
SEER221.018.0
EER212.011.0
Heating, same conditions
HSPF2 Region IV / V10.0 / 8.08.1 / 7.0
8.3 °C: min. / rated / max.BTU/h8,870 / 36,000 / 43,2008,870 / 36,000 / 43,200
8.3 °C: COP min. / rated / max.3.94 / 3.56 / 3.173.56 / 3.26 / 2.75
−8.3 °C: min. / rated / max.BTU/h9,000 / 36,000 / 37,7209,000 / 36,000 / 37,720
−8.3 °C: COP min. / rated / max.2.90 / 2.30 / 2.002.64 / 2.10 / 2.00
−15 °C: min. / rated / max.BTU/h9,000 / 36,000 / 36,0009,000 / 33,000 / 33,000
−15 °C: COP min. / rated / max.2.16 / 2.10 / 2.101.97 / 1.90 / 1.90
Coldest point of both certificates (same temperature)
Test temperature−30 °C (−22 °F)−30 °C (−22 °F)
Capacity min. / max.BTU/h8,000 / 26,2008,000 / 26,200
COP min. / max.1.55 / 1.511.41 / 1.40
Certification
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
AHRI certificate · NEEP record214931589 · 392109214931595 · 392103
RefrigerantR-32 (GWP 675, IPCC AR4; class A2L)R-32 (GWP 675, IPCC AR4; class A2L)

“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation. AHRI certificate values of the GWHD(36)ND6MO published by NEEP, retrieved November 10, 2026; capacities in BTU/h at 21.1 °C indoors in heating and 26.7 °C in cooling. The values of the other four sizes are in the “Five sizes” section.

All five sizes are on AirGreen’s website.

To choose the size and the heads, talk it over with our team: bring the list of rooms, their dimensions, the floor of each one, the planned outdoor location and your current heating.

Sources and documents

Where each figure comes from