Home / Comparisons / Water heaters
GIANT 172STE and BRADFORD WHITE RE280T6, in litres rather than gallons
In Québec, a “60-gallon” tank is counted in imperial gallons. GIANT's spec sheet lists 279 L for the 172STE, or 61 imperial gallons. BRADFORD WHITE, which sizes its models in US gallons, lists 288 L for the RE280T6: 76 US gallons, or 63 imperial gallons. Two tanks 24 in across, within an inch of the same height. What sets them apart is inside, and in the documents.
Standard 172STE
172STE-3F7M · 240 V · 279 L
Spec sheet GI-FT-RES-ELECT-STE-FR-0726, July 2026
See the product page
RE280T6
RE280T6-1NCWW · 240 V · 288 L
Spec sheet C1201-0926 CANADA
See the product pageA 60-gallon tank: 273 litres or 227 litres, depending on the gallon
The imperial gallon, the one in Canadian law, is 4.546 L. The US gallon is 3.785 L. American manufacturers size their water heaters in US gallons; in Québec, people still talk in imperial gallons. So the same number on the label does not mean the same tank. Move the slider to see the gap.
- imperial gallons
- US gallons
- GIANT 172STE, 279 L
- BRADFORD WHITE RE280T6, 288 L
- BRADFORD WHITE RE265T6, 231 L
All three units are printed on both spec sheets; AirGreen converts nothing in these tiles. The RE265T6 is not compared on this page: it shows that a BRADFORD WHITE “61-gallon” holds 48 L less than a GIANT “60-gallon”.
Two 24-inch tanks, cut open
From the outside, the two tanks look alike. Pick a part: it lights up in both diagrams, with what each manufacturer writes about it.
Two square-flange immersion elements, made by GIANT and CSA approved: 4,500 W each at 240 V. Per the brochure, they can be replaced without special tools.
Brochure GI-PB019Fr-0726; Standard parts list, January 2025Magnesium anode, separate from the water connections. The manual asks for an inspection every two years and a replacement once more than half is consumed.
Standard parts list, January 2025; manual GI-IM017En-0726Dip tube with heat trap: cold water enters at the top and travels down toward the bottom of the tank.
Standard parts list, January 2025Glass-lined tank. The brochure table lists a single internal anti-corrosion coating for the Standard line.
Spec sheet GI-FT-RES-ELECT-STE-FR-0726; brochure GI-PB019Fr-0726Foam insulation of uniform thickness; the thickness is not published. Standby loss printed on the spec sheet: 78 W.
Spec sheet GI-FT-RES-ELECT-STE-FR-07263/4 in NPT dielectric fittings and heat traps, factory installed.
Spec sheet GI-FT-RES-ELECT-STE-FR-0726Plastic drain valve on the Standard line. Temperature and pressure relief valve installed; a 90° elbow discharge pipe is supplied.
Brochure GI-PB019Fr-0726; Standard parts list, January 2025Two screw-in copper immersion elements: 4,500 W each at 240 V. Unless specified otherwise when ordering, they are wired so only one heats at a time. INCOLOY-type element available on request.
Spec sheet C1201-0926 CANADASegmented magnesium anode, built into the hot water outlet fitting. Aluminum anodes are also in the parts list. The manual asks for an inspection every two years.
Parts book 238-54105-00G, June 2025; manual 238-44422-00ZPEX inlet tube with the Hydrojet system. The spec sheet describes it as a device that reduces sediment and increases the first hour rating.
Spec sheet C1201-0926 CANADA; parts book 238-54105-00GVitraglas lining, the brand's own enamel formula, with Microban antimicrobial protection on the lining surface. The spec sheet states that this protection does not protect people from disease-causing organisms. Test pressure 300 psi, working pressure 150 psi.
Spec sheet C1201-0926 CANADANon-CFC foam on the sides and top of the tank; the thickness is not published. Standby loss printed on the spec sheet: 84 W, with top water inlet.
Spec sheet C1201-0926 CANADAFactory-installed 3/4 in NPT dielectric fittings; flexible-disk heat traps, also factory installed.
Spec sheet C1201-0926 CANADABrass drain valve. Temperature and pressure relief valve installed.
Parts book 238-54105-00G; spec sheet C1201-0926 CANADAAirGreen diagrams, drawn to scale from the published dimensions (diameter and height). What each part is comes from the spec sheets, brochures and parts lists cited; their exact position inside is indicative, and neither manufacturer publishes the insulation thickness.
What the two manuals ask for
Six points both installation manuals cover. The intervals are the manufacturers' own.
GIANT60 °C (140 °F) on Canadian models. Manual GI-IM017En-0726
BRADFORD WHITE60 °C (140 °F) for every household electric water heater in Canada; the manual cites CSA C22.2 No. 110. Manual 238-44422-00Z, rev. 01/24
GIANTAdjustable thermostats; manual-reset high-limit control. Spec sheet GI-FT-RES-ELECT-STE-FR-0726; Standard parts list
BRADFORD WHITEFast-acting surface-mount thermostat with a manual-reset high-limit energy cut-off. Spec sheet C1201-0926 CANADA
GIANTEvery two years; replace once more than half is consumed. Manual GI-IM017En-0726
BRADFORD WHITEEvery two years; more often with softened water. Manual 238-44422-00Z, rev. 01/24
GIANTAbout a pail of water through the drain valve, once a year. Manual GI-IM017En-0726
BRADFORD WHITEAbout a gallon of water through the drain valve, every month. Manual 238-44422-00Z, rev. 01/24
GIANTOperate by hand at least once a year. Manual GI-IM017En-0726
BRADFORD WHITECheck at least once a year. Manual 238-44422-00Z, rev. 01/24
GIANT120 V (1,500 W), 208 V and 240 V (4,500 W). Brochure GI-PB019Fr-0726
BRADFORD WHITE120, 208, 240, 277 and 480 V depending on the order; 240 V and two 4,500 W elements by default. Spec sheet C1201-0926 CANADA
Same footprint, a wider pan for one
Both tanks are 24 in across. The difference comes from the drain pan each manual describes, and from service clearances, which only BRADFORD WHITE puts a number on.


Manufacturer photos shown at the same height scale. Their width depends on the camera angle: for the diameter, rely on the listed dimensions.
Top view, diagram. Solid circle: the 24 in tank. Dashed circle: the smallest drain pan the manual accepts. A pan is not required in every case: see the table.
| Measure | GIANT 172STE | BRADFORD WHITE RE280T6 |
|---|---|---|
| Diameter × overall height | 24 in × 59 7/8 in61 × 152 cm | 24 in × 59 1/4 in610 × 1,505 mm, to the top of the heater |
| Connection height, water fittings | Not published by the manufacturer | 60 1/4 in1,530 mm from the floor |
| Shipping weight | 185 lb84 kg | 183 lb83 kg, approximate |
| Water connections | 3/4 in NPT, dielectric | 3/4 in NPT, dielectric |
| Drain pan | At least 2 in (5.0 cm) wider than the diameter, and 3 in (7.5 cm) deeprequired where there is no floor drain next to the heater | At least 4 in (10.2 cm) larger than the diameter, in length and widthrequired where a leak could cause damage |
| Recommended clearances | Not published by the manufacturer | 18 in (45.7 cm) above and 24 in (61 cm) in front, for servicing0 in required to combustible material |
| Relief valve discharge pipe | Ends 6 to 12 in (15.2 to 30.5 cm) above the floor drain | Ends 6 in (15.3 cm) or less above the floor |
| Recommended breaker or fuse | 25 A, No. 10 wirefor 4,500 W at 240 V | 25 Afor 4,500 W at 240 V |
| Current draw at 240 V | 18.8 A | Not published by the manufacturer |
What people ask about these two water heaters
How many litres does a 60-gallon water heater hold?
It depends on the gallon. Sixty imperial gallons are 273 L; sixty US gallons are 227 L. The GIANT 172STE, sold as a 60-gallon in Québec, is listed at 279 L on its spec sheet. The BRADFORD WHITE RE280T6 is listed at 288 L, which its sheet gives as 76 US gallons or 63 imperial gallons.
Is the 61-gallon BRADFORD WHITE RE265T6 the equivalent of a GIANT 60-gallon?
No. Its 61 gallons are US gallons: the C1201 sheet lists it at 231 L, or 51 imperial gallons. GIANT's 172STE holds 279 L. In BRADFORD WHITE's upright line, the RE280T6, at 288 L, is the one closest to the 172STE.
Which of the two heats water faster?
Both carry 4,500 W elements at 240 V. BRADFORD WHITE publishes a recovery of 79 L per hour for a 50 °C rise and a first hour rating of 75 US gallons (284 L). GIANT's sheet publishes neither; a missing figure says nothing about the result.
Is there a difference in electricity use?
For heating the water, no: an immersed element turns all the electricity into heat, in one unit as in the other. The spec sheets list a standby loss of 78 W for the 172STE and 84 W for the RE280T6, without stating the test method. So this page puts no dollar figure on the gap.
Can one replace the other without redoing the installation?
Both are 24 in across, with 3/4 in NPT connections on top and 4,500 W elements at 240 V, for which both manuals recommend 25 A. The heights differ by less than an inch. The drain pan asked for is not the same: 26 in minimum for the GIANT, 28 in for the BRADFORD WHITE. Hooking it up remains work for a plumber and an electrician.
Why does this page not compare warranties?
A warranty has to be read in full, with its conditions and exclusions, and the two manufacturers do not write theirs the same way. Each unit's warranty documents are provided with the quote.
Does this page say which one to buy?
No. It sets side by side what the spec sheets, parts lists and manuals publish, with the source of each value. The number of people at home, the space available and the existing electrical installation weigh as much as these figures.
Every published value, side by side
| Measure | GIANT 172STE | BRADFORD WHITE RE280T6 |
|---|---|---|
| Volume | ||
| Tank volume, in litres | 279 L | 288 L |
| Volume in imperial gallons | 61 imp. gal | 63 imp. gal |
| Volume in US gallons | 74 US gal | 76 US gal |
| Heating the water | ||
| Heating elements | 2, immersed, square flange | 2, immersed, copper, screw-in |
| Element wattage at 240 V | 4,500 W each | 4,500 W eachnon-simultaneous operation by default |
| First hour rating | Not published by the manufacturer | 75 US gal284 L, with 4,500 W / 4,500 W |
| Recovery | Not published by the manufacturer | 79 L/hfor a 50 °C rise; 21 US gal/h for 90 °F |
| Losses | ||
| Standby loss | 78 W“perte de chaleur latente” on the sheet | 84 W“standby loss”, top water inlet |
| Construction | ||
| Tank and lining | Glass-lined tank, single internal coating | Vitraglas lining with Microban |
| Anode | Magnesium, separate from the fittings | Magnesium, segmented, on the hot water outlet |
| Cold water inlet | Dip tube with heat trap | PEX tube, Hydrojet system |
| Insulation | Foam, thickness not published | Non-CFC foam, thickness not published |
| Drain valve | Plastic | Brass |
| Test and working pressure | Not published by the manufacturer | 300 and 150 psi2,068 and 1,034 kPa |
| Dimensions and weight | ||
| Diameter × overall height | 24 in × 59 7/8 in61 × 152 cm | 24 in × 59 1/4 in610 × 1,505 mm, to the top of the heater |
| Shipping weight | 185 lb84 kg | 183 lb83 kg, approximate |
| Standards and documents | ||
| Standards cited | CSA 22.2 for construction; NRCan energy efficiency standards | UL 174; cUL to Canadian standard C22.2 No. 110 |
| Spec sheet | GI-FT-RES-ELECT-STE-FR-0726July 2026 | C1201-0926 CANADAFrench version: FC1201-0926 CANADA |
| Installation manual | GI-IM017En-0726 | 238-44422-00Zrev. 01/24 |
“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.
Both are on the AirGreen site.
To choose for your home, talk it over with our team: the number of people, the space available and the existing electrical installation matter as much as the figures.
Where each figure comes from
Data verified on November 9, 2026. Volumes, dimensions, weight, wattage and standby loss: manufacturers' spec sheets. Construction: brochure and parts lists. Installation and upkeep: manuals. GIANT's July 2026 sheet lists the 172STE-2F7M (208 V); GIANT's parts list and website also list the 172STE at 240 V, with the same dimensions.
Trademarks. GIANT, BRADFORD WHITE, Vitraglas, Hydrojet, Microban and INCOLOY are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer for both brands; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca: every figure reported is checked again.