GIANT Standard 172STE and BRADFORD WHITE RE280T6, 60 gallons

Home / Comparisons / Water heaters

Comparison · Electric water heater · 60 imperial gallons

GIANT 172STE and BRADFORD WHITE RE280T6, in litres rather than gallons

In Québec, a “60-gallon” tank is counted in imperial gallons. GIANT's spec sheet lists 279 L for the 172STE, or 61 imperial gallons. BRADFORD WHITE, which sizes its models in US gallons, lists 288 L for the RE280T6: 76 US gallons, or 63 imperial gallons. Two tanks 24 in across, within an inch of the same height. What sets them apart is inside, and in the documents.

Volume: 279 L and 288 LElements: 2 × 4,500 W and 2 × 4,500 W, at 240 VListed standby loss: 78 W and 84 WDiameter: 24 in and 24 in
GIANT Standard 172STE (AirGreen image)
GIANT

Standard 172STE

172STE-3F7M · 240 V · 279 L

Spec sheet GI-FT-RES-ELECT-STE-FR-0726, July 2026

See the product page
BRADFORD WHITE RE280T6 (AirGreen image)
BRADFORD WHITE

RE280T6

RE280T6-1NCWW · 240 V · 288 L

Spec sheet C1201-0926 CANADA

See the product page
Gallons

A 60-gallon tank: 273 litres or 227 litres, depending on the gallon

The imperial gallon, the one in Canadian law, is 4.546 L. The US gallon is 3.785 L. American manufacturers size their water heaters in US gallons; in Québec, people still talk in imperial gallons. So the same number on the label does not mean the same tank. Move the slider to see the gap.

…in imperial gallons273 L
…in US gallons227 L
Gap between the two46 L
100 L170 L240 L310 L380 L
  • imperial gallons
  • US gallons
  • GIANT 172STE, 279 L
  • BRADFORD WHITE RE280T6, 288 L
  • BRADFORD WHITE RE265T6, 231 L
GIANT 172STE “60 gallons” in Québec
279L
Spec sheet GI-FT-RES-ELECT-STE-FR-0726: 74 US gal, 279 L, 61 imp. gal
BRADFORD WHITE RE280T6 76 US gallons on the sheet
288L
Spec sheet C1201-0926 CANADA: 76 US gal, 63 imp. gal, 288 L
BRADFORD WHITE RE265T6 reference, not compared
231L
Spec sheet C1201-0926 CANADA: 61 US gal, 51 imp. gal, 231 L

All three units are printed on both spec sheets; AirGreen converts nothing in these tiles. The RE265T6 is not compared on this page: it shows that a BRADFORD WHITE “61-gallon” holds 48 L less than a GIANT “60-gallon”.

No “Cost per season” section on this page. Both units heat water with immersed elements: one kilowatt-hour of electricity gives one kilowatt-hour of heat in the water, whatever the model. Their consumption depends on how much hot water the household uses. The only efficiency figure both spec sheets publish is standby loss, 78 W and 84 W; neither states its test method.
Tank cutaway

Two 24-inch tanks, cut open

From the outside, the two tanks look alike. Pick a part: it lights up in both diagrams, with what each manufacturer writes about it.

GIANT 172STEDiagram
59 7/8 in24 in
Heating elements

Two square-flange immersion elements, made by GIANT and CSA approved: 4,500 W each at 240 V. Per the brochure, they can be replaced without special tools.

Brochure GI-PB019Fr-0726; Standard parts list, January 2025
BRADFORD WHITE RE280T6Diagram
59 1/4 in24 in
Heating elements

Two screw-in copper immersion elements: 4,500 W each at 240 V. Unless specified otherwise when ordering, they are wired so only one heats at a time. INCOLOY-type element available on request.

Spec sheet C1201-0926 CANADA

AirGreen diagrams, drawn to scale from the published dimensions (diameter and height). What each part is comes from the spec sheets, brochures and parts lists cited; their exact position inside is indicative, and neither manufacturer publishes the insulation thickness.

Settings and upkeep

What the two manuals ask for

Six points both installation manuals cover. The intervals are the manufacturers' own.

Thermostat factory setting

GIANT60 °C (140 °F) on Canadian models. Manual GI-IM017En-0726

BRADFORD WHITE60 °C (140 °F) for every household electric water heater in Canada; the manual cites CSA C22.2 No. 110. Manual 238-44422-00Z, rev. 01/24

Thermostats and high-limit control

GIANTAdjustable thermostats; manual-reset high-limit control. Spec sheet GI-FT-RES-ELECT-STE-FR-0726; Standard parts list

BRADFORD WHITEFast-acting surface-mount thermostat with a manual-reset high-limit energy cut-off. Spec sheet C1201-0926 CANADA

Anode: inspection

GIANTEvery two years; replace once more than half is consumed. Manual GI-IM017En-0726

BRADFORD WHITEEvery two years; more often with softened water. Manual 238-44422-00Z, rev. 01/24

Draining sediment

GIANTAbout a pail of water through the drain valve, once a year. Manual GI-IM017En-0726

BRADFORD WHITEAbout a gallon of water through the drain valve, every month. Manual 238-44422-00Z, rev. 01/24

Relief valve: test

GIANTOperate by hand at least once a year. Manual GI-IM017En-0726

BRADFORD WHITECheck at least once a year. Manual 238-44422-00Z, rev. 01/24

Voltages offered

GIANT120 V (1,500 W), 208 V and 240 V (4,500 W). Brochure GI-PB019Fr-0726

BRADFORD WHITE120, 208, 240, 277 and 480 V depending on the order; 240 V and two 4,500 W elements by default. Spec sheet C1201-0926 CANADA

Installation

Same footprint, a wider pan for one

Both tanks are 24 in across. The difference comes from the drain pan each manual describes, and from service clearances, which only BRADFORD WHITE puts a number on.

GIANT Standard 172STE, manufacturer photo, cut out
GIANT 172STE59 7/8 in tall152 cm · 24 in diameter
BRADFORD WHITE RE280T6, manufacturer photo, cut out
BRADFORD WHITE RE280T659 1/4 in tall1,505 mm to the top · connections at 60 1/4 in · 24 in diameter

Manufacturer photos shown at the same height scale. Their width depends on the camera angle: for the diameter, rely on the listed dimensions.

30 in
GIANT 172STE

Pan: at least 2 in wider than the diameter (manual GI-IM017En-0726)
BRADFORD WHITE RE280T6

Pan: at least 4 in larger than the diameter (manual 238-44422-00Z)

Top view, diagram. Solid circle: the 24 in tank. Dashed circle: the smallest drain pan the manual accepts. A pan is not required in every case: see the table.

MeasureGIANT 172STEBRADFORD WHITE RE280T6
Diameter × overall height24 in × 59 7/8 in61 × 152 cm24 in × 59 1/4 in610 × 1,505 mm, to the top of the heater
Connection height, water fittingsNot published by the manufacturer60 1/4 in1,530 mm from the floor
Shipping weight185 lb84 kg183 lb83 kg, approximate
Water connections3/4 in NPT, dielectric3/4 in NPT, dielectric
Drain panAt least 2 in (5.0 cm) wider than the diameter, and 3 in (7.5 cm) deeprequired where there is no floor drain next to the heaterAt least 4 in (10.2 cm) larger than the diameter, in length and widthrequired where a leak could cause damage
Recommended clearancesNot published by the manufacturer18 in (45.7 cm) above and 24 in (61 cm) in front, for servicing0 in required to combustible material
Relief valve discharge pipeEnds 6 to 12 in (15.2 to 30.5 cm) above the floor drainEnds 6 in (15.3 cm) or less above the floor
Recommended breaker or fuse25 A, No. 10 wirefor 4,500 W at 240 V25 Afor 4,500 W at 240 V
Current draw at 240 V18.8 ANot published by the manufacturer
Licensed work. Wiring and plumbing a water heater is work for licensed trades. The values above are those of the manuals; they replace neither the unit's rating plate nor the codes in force.
Questions

What people ask about these two water heaters

How many litres does a 60-gallon water heater hold?

It depends on the gallon. Sixty imperial gallons are 273 L; sixty US gallons are 227 L. The GIANT 172STE, sold as a 60-gallon in Québec, is listed at 279 L on its spec sheet. The BRADFORD WHITE RE280T6 is listed at 288 L, which its sheet gives as 76 US gallons or 63 imperial gallons.

Is the 61-gallon BRADFORD WHITE RE265T6 the equivalent of a GIANT 60-gallon?

No. Its 61 gallons are US gallons: the C1201 sheet lists it at 231 L, or 51 imperial gallons. GIANT's 172STE holds 279 L. In BRADFORD WHITE's upright line, the RE280T6, at 288 L, is the one closest to the 172STE.

Which of the two heats water faster?

Both carry 4,500 W elements at 240 V. BRADFORD WHITE publishes a recovery of 79 L per hour for a 50 °C rise and a first hour rating of 75 US gallons (284 L). GIANT's sheet publishes neither; a missing figure says nothing about the result.

Is there a difference in electricity use?

For heating the water, no: an immersed element turns all the electricity into heat, in one unit as in the other. The spec sheets list a standby loss of 78 W for the 172STE and 84 W for the RE280T6, without stating the test method. So this page puts no dollar figure on the gap.

Can one replace the other without redoing the installation?

Both are 24 in across, with 3/4 in NPT connections on top and 4,500 W elements at 240 V, for which both manuals recommend 25 A. The heights differ by less than an inch. The drain pan asked for is not the same: 26 in minimum for the GIANT, 28 in for the BRADFORD WHITE. Hooking it up remains work for a plumber and an electrician.

Why does this page not compare warranties?

A warranty has to be read in full, with its conditions and exclusions, and the two manufacturers do not write theirs the same way. Each unit's warranty documents are provided with the quote.

Does this page say which one to buy?

No. It sets side by side what the spec sheets, parts lists and manuals publish, with the source of each value. The number of people at home, the space available and the existing electrical installation weigh as much as these figures.

All values

Every published value, side by side

MeasureGIANT 172STEBRADFORD WHITE RE280T6
Volume
Tank volume, in litres279 L288 L
Volume in imperial gallons61 imp. gal63 imp. gal
Volume in US gallons74 US gal76 US gal
Heating the water
Heating elements2, immersed, square flange2, immersed, copper, screw-in
Element wattage at 240 V4,500 W each4,500 W eachnon-simultaneous operation by default
First hour ratingNot published by the manufacturer75 US gal284 L, with 4,500 W / 4,500 W
RecoveryNot published by the manufacturer79 L/hfor a 50 °C rise; 21 US gal/h for 90 °F
Losses
Standby loss78 W“perte de chaleur latente” on the sheet84 W“standby loss”, top water inlet
Construction
Tank and liningGlass-lined tank, single internal coatingVitraglas lining with Microban
AnodeMagnesium, separate from the fittingsMagnesium, segmented, on the hot water outlet
Cold water inletDip tube with heat trapPEX tube, Hydrojet system
InsulationFoam, thickness not publishedNon-CFC foam, thickness not published
Drain valvePlasticBrass
Test and working pressureNot published by the manufacturer300 and 150 psi2,068 and 1,034 kPa
Dimensions and weight
Diameter × overall height24 in × 59 7/8 in61 × 152 cm24 in × 59 1/4 in610 × 1,505 mm, to the top of the heater
Shipping weight185 lb84 kg183 lb83 kg, approximate
Standards and documents
Standards citedCSA 22.2 for construction; NRCan energy efficiency standardsUL 174; cUL to Canadian standard C22.2 No. 110
Spec sheetGI-FT-RES-ELECT-STE-FR-0726July 2026C1201-0926 CANADAFrench version: FC1201-0926 CANADA
Installation manualGI-IM017En-0726238-44422-00Zrev. 01/24

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.

Both are on the AirGreen site.

To choose for your home, talk it over with our team: the number of people, the space available and the existing electrical installation matter as much as the figures.

Sources and documents

Where each figure comes from

GIANT spec sheet, “Modèles standards”GI-FT-RES-ELECT-STE-FR-0726, July 2026 · volumes, wattage, standby loss, dimensions, weight · consulted on November 9, 2026
GIANT brochure, Standard, Cascade and Super CascadeGI-PB019Fr-0726, July 2026 · elements, current at 240 V, coating, drain valve · consulted on November 9, 2026
GIANT parts list, Standard, top inletGiant-Parts-DT016, January 2025 · models 172STE-2F7M and 172STE-3F7M · consulted on November 9, 2026
GIANT owner's manual, residential electric water heaterGI-IM017En-0726 · pan, relief valve, thermostat, anode, Table 1 · consulted on November 9, 2026
GIANT page, Standard, Cascade and Super Cascadegiantinc.com · “STANDARD 172STE, 60 gallons imp., 208 V | 240 V” · consulted on November 9, 2026
BRADFORD WHITE spec sheet, “Upright Electric Residential Water Heater”C1201-0926 CANADA and FC1201-0926 CANADA · volumes, standby loss, first hour rating, dimensions, weight · consulted on November 9, 2026
BRADFORD WHITE replacement parts book, Canada238-54105-00G, effective June 2025 · anode, inlet tube, drain valve · consulted on November 9, 2026
BRADFORD WHITE installation and operation manual238-44422-00Z, rev. 01/24 · pan, clearances, recommended fuse, upkeep · consulted on November 9, 2026
Weights and Measures Act (Canada)R.S.C. 1985, c. W-6, Schedule II: gallon = 454,609/100,000,000 cubic metre · current to October 19, 2026
NIST Special Publication 811, Appendix B.8US gallon = 3.785412 L · consulted on November 10, 2026