GIANT ECOPEAK 172STPS and GIANT Standard 172STE, 60 gallons

Home / Comparisons / Water heaters

Comparison · GIANT electric water heater · 60 imperial gallons

GIANT ECOPEAK and GIANT Standard, 60 gallons: three elements or two

Same 279 L tank, same dimensions, same listed standby loss. The difference is in the heating elements: three on the ECOPEAK, at 3,800, 3,000 and 800 W, against two 4,500 W elements on the Standard. GIANT says so itself: the ECOPEAK does not heat water faster. It draws less power at a time, and its full recovery takes longer.

Elements: 3 and 2Maximum power drawn: 3,800 W and 4,500 WSmall draw: 800 W and 4,500 WVolume: 279 L and 279 L
GIANT Expert Plus ECOPEAK 172STPS (AirGreen image)
GIANT

Expert Plus ECOPEAK 172STPS

172STPS-3S8M · 240 V · 279 L

Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426, April 2026

See the product page
GIANT Standard 172STE (AirGreen image)
GIANT

Standard 172STE

172STE-3F7M · 240 V · 279 L

Spec sheet GI-FT-RES-ELECT-STE-FR-0726, July 2026

See the product page
The wattage of each element, at 240 V
ECOPEAK 172STPS
Top
3,800 W
Middle
3,000 W
Bottom
800 W
Standard 172STE
Top
4,500 W
Bottom
4,500 W
A winter day

What each tank draws, hour by hour

A water heater does not know the time: its thermostats switch the elements on when the water cools or is drawn. Hydro-Québec, for its part, watches two periods on winter days, morning and evening. Move the time, then pick a type of draw: the elements that heat light up in each tank.

7 h 00
Peak periods per Hydro-Québec: mornings 6 to 10 a.m., evenings 4 to 8 p.m. (pages consulted on November 10, 2026)Solid band: on almost all the time, Hydro-Québec writesHatched band: heats as needed, with no fixed hours
ECOPEAK 172STPSDiagram
Top3,800 WMiddle3,000 WBottom800 W
0W

Standard 172STEDiagram
Top4,500 WBottom4,500 W
0W

The bands are not measured running hours: no document gives any, and the thermostat stops each element once the water is at temperature. They show each element's wattage and the role the documents give it. Wattages: GIANT spec sheets of April and July 2026. Role of the elements: ECOPEAK sheet (note under the table), GIANT's “Advantages of ECOPEAK” page and Hydro-Québec's page on the ECOPEAK. On the Standard, the diagram lights the bottom element for a draw as an indication only: GIANT writes only that the two elements run alternately. Peak periods: Hydro-Québec, page on the ECOPEAK; the Rate Flex D page places peak events at the same hours, from December 1 to March 31. These hours can change.

What about the bill? GIANT writes that energy consumption is identical and that billing does not change in Québec. That is why this page has no “Cost per season” section: the two tanks have the same volume and the same listed standby loss (78 W), and GIANT states no difference in consumption between them.
What a field study observed. CanmetENERGY (Natural Resources Canada) monitored water heaters in Sherbrooke, including 110 two-element and 12 three-element 60-gallon units. In that sample, the three-element units flattened and reduced the morning peak; they also used more at night and more energy overall, and the report cannot say why. The authors warn that 12 units may not represent a larger number.
Hot water

As much hot water, a slower recovery

Both tanks hold 279 L. Per GIANT, the average user will see no difference in the amount of hot water. What changes is the time needed to reheat the whole tank once emptied: longer with three elements.

How many showers in one tank?

Basis: GIANT gives an average of 33 minutes of total showering for a 60-imperial-gallon water heater, with a 9.5 L/min showerhead, not counting recovery between showers. GIANT gives this figure for a 60-imperial-gallon water heater, the size of both tanks compared; the division is AirGreen's.

When GIANT advises against the ECOPEAK

The manufacturer itself writes that an ECOPEAK should not be bought in four cases:

  • a family of 5 or 6
  • therapeutic baths
  • several baths a day
  • extra-long showers
GIANT, “Advantages of ECOPEAK” page, giantinc.com, consulted on November 9, 2026. GIANT also notes there that long showers taken close together are slightly more affected than with two elements.
Construction

Two product lines, not just one more element

The 60-gallon ECOPEAK belongs to the Expert Plus line; the 172STE compared here is from the Standard line. The spec sheets do not describe the tank, the anode or the drain valve the same way. Peak management, for its part, relies neither on hotter stored water nor on remote control: it comes down to the number of elements, their wattage and their wiring.

Heating elements

ECOPEAK 172STPSThree screw-in immersion elements, medium density, made by GIANT and CSA approved. GIANT describes the bottom one as very low density. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426; “Advantages of ECOPEAK” page

Standard 172STETwo square-flange immersion elements, made by GIANT and CSA approved. Brochure GI-PB019Fr-0726

Tank and lining

ECOPEAK 172STPSTank lined with a coat of cobalt blue glass, enriched with zircon. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426

Standard 172STEGlass-lined tank; single internal anti-corrosion coating. Spec sheet GI-FT-RES-ELECT-STE-FR-0726; Brochure GI-PB019Fr-0726

Anode

ECOPEAK 172STPSOversized magnesium anode. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426

Standard 172STEMagnesium anode; the brochure calls it “normal”. Spec sheet GI-FT-RES-ELECT-STE-FR-0726; Brochure GI-PB019Fr-0726

Drain valve

ECOPEAK 172STPSBrass. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426

Standard 172STEPlastic. Brochure GI-PB019Fr-0726

Thermostats, temperature and controls

ECOPEAK 172STPSThree thermostats, one per element; the top one is combined with the high-limit control. Factory setting: 60 °C on Canadian models. The ECOPEAK supplement describes no mixing valve, no electronic control and no link to the power grid. Supplement GI-IM028En-0825; manual GI-IM017En-0726

Standard 172STETwo thermostats; the top one is combined with the manual-reset high-limit control. Factory setting: 60 °C on Canadian models. Standard parts list, January 2025; manual GI-IM017En-0726

Water connections and heat traps

ECOPEAK 172STPS3/4 in NPT dielectric fittings and heat traps, factory installed. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426

Standard 172STE3/4 in NPT dielectric fittings and heat traps, factory installed. Spec sheet GI-FT-RES-ELECT-STE-FR-0726

Installation

Same floor space, not the same circuit

Both tanks have the same dimensions and the same weight. The difference is on the electrical side: the ECOPEAK never draws more than 3,800 W, the Standard 4,500 W. GIANT writes that this lets a household go from a 40 to a 60-gallon ECOPEAK without changing the breaker or the wire size.

GIANT Expert Plus ECOPEAK 172STPS, manufacturer photo, cut out
ECOPEAK 172STPS59 7/8 in tall24 in diameter · 185 lb (84 kg)
GIANT Standard 172STE, manufacturer photo, cut out
Standard 172STE59 7/8 in tall24 in diameter · 185 lb (84 kg)

Manufacturer photos shown at the same height. Their width depends on the camera angle: for the diameter, rely on the listed dimensions.

MeasureGIANT ECOPEAK 172STPSGIANT Standard 172STE
Diameter × overall height24 in × 59 7/8 in61 cm diameter; for the height the sheet prints “(125)” cm, while 59 7/8 in is 152 cm24 in × 59 7/8 in61 × 152 cm
Shipping weight185 lb84 kg185 lb84 kg
Water connections3/4 in NPT, dielectric3/4 in NPT, dielectric
Voltages offered208 V or 240 V172STPS-2S8M and 172STPS-3S8M; April 2026 spec sheet120 V, 208 V or 240 Vbrochure GI-PB019Fr-0726: 1,500 W at 120 V, 4,500 W at 208 V and at 240 V
Recommended breaker at 240 V20 A, No. 12 wirefor 3,800 W; ECOPEAK supplement GI-IM02825 A, No. 10 wirefor 4,500 W; manual GI-IM017, Table 1
Drain panAt least 2 in (5.0 cm) wider than the diameter, and 3 in (7.5 cm) deepAt least 2 in (5.0 cm) wider than the diameter, and 3 in (7.5 cm) deep
Licensed work. Wiring and plumbing a water heater is work for licensed trades. Only an electrician can confirm that the existing circuit is suitable; the values above are those of the manuals and replace neither the rating plate nor the codes in force.
Questions

What people ask about the ECOPEAK

Does a three-element water heater heat water faster?

No, and GIANT says so plainly. The ECOPEAK never draws more than 3,800 W, against 4,500 W for the 60-gallon Standard. Recovering the whole tank therefore takes longer than with two elements.

Does the ECOPEAK use less electricity?

GIANT writes that energy consumption is identical and that the bill does not change in Québec. A CanmetENERGY study in Sherbrooke even measured more energy on 12 three-element water heaters than on 110 two-element ones, without being able to explain it, and warning that the sample is small. What changes is the power drawn at a given moment.

What are Hydro-Québec's winter peak hours?

Its page on the ECOPEAK places peak periods in the morning, from 6 to 10 a.m., and in the evening, from 4 to 8 p.m. The Rate Flex D page puts peak events at the same hours, from December 1 to March 31, with a maximum of 30 events per winter. Pages consulted on November 10, 2026; these hours can change.

Does Hydro-Québec have a program tied to the ECOPEAK?

Hydro-Québec has a page on the ECOPEAK and mentions there a purchase offer at participating partners, under certain conditions, noting that it may end the offer at its discretion. The conditions and the list of partners are on its site. This information, noted on November 10, 2026, can change; AirGreen promises no amount.

Will I have less hot water with an ECOPEAK?

Both tanks hold 279 L. GIANT writes that the average user will see no difference, but advises against the ECOPEAK for families of 5 or 6 and for people who take therapeutic baths, several baths a day or extra-long showers.

Is a different breaker needed?

GIANT's manuals list 20 A and No. 12 wire for 3,800 W at 240 V, the ECOPEAK's maximum power, and 25 A and No. 10 wire for 4,500 W, the Standard's. It is up to an electrician to check the existing circuit.

Are the two tanks the same size?

Yes: 279 L, 24 in diameter, 59 7/8 in tall and 185 lb shipping weight, per both spec sheets. The listed standby loss is also the same, 78 W.

Why does this page not compare warranties?

A warranty has to be read in full, with its conditions and exclusions. Each unit's warranty documents are provided with the quote.

All values

Every published value, side by side

MeasureGIANT ECOPEAK 172STPSGIANT Standard 172STE
Volume
Tank volume279 L61 imp. gal, 74 US gal279 L61 imp. gal, 74 US gal
Heating elements
Heating elements3, screw-in, medium density2, square flange
Top element3,800 W4,500 W
Middle element3,000 WNot applicabletwo-element tank
Bottom element800 W4,500 W
Maximum power drawn3,800 Wthe top alone, or the middle and bottom together4,500 Wone element at a time
Losses
Standby loss78 W78 W
Construction
Tank and liningCobalt blue glass, enriched with zirconGlass-lined tank, single internal coating
AnodeMagnesium, oversizedMagnesium
Drain valveBrassPlastic
Temperature and controls
Thermostats3one per element2one per element
Factory thermostat setting60 °C140 °F, Canadian models60 °C140 °F, Canadian models
Dimensions and installation
Diameter × overall height24 in × 59 7/8 in61 cm diameter; for the height the sheet prints “(125)” cm, while 59 7/8 in is 152 cm24 in × 59 7/8 in61 × 152 cm
Shipping weight185 lb84 kg185 lb84 kg
Recommended breaker at 240 V20 A, No. 12 wirefor 3,800 W; ECOPEAK supplement GI-IM02825 A, No. 10 wirefor 4,500 W; manual GI-IM017, Table 1
Documents
Spec sheetGI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426April 2026GI-FT-RES-ELECT-STE-FR-0726July 2026
Installation manualGI-IM017En-0726 and supplement GI-IM028En-0825GI-IM017En-0726

Bars on the same row share the same scale. No value is highlighted: higher wattage reheats the tank faster, lower wattage asks less of the grid.

Both are on the AirGreen site.

To choose for your home, talk it over with our team: the number of people, your hot water habits and the existing electrical circuit matter as much as the figures.

Sources and documents

Where each figure comes from

GIANT spec sheet, “Modèles standards ECOPEAK, Expert Plus”GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426, April 2026 · three elements, maximum power, standby loss, dimensions · consulted on November 9, 2026
GIANT spec sheet, “Modèles standards”GI-FT-RES-ELECT-STE-FR-0726, July 2026 · consulted on November 9, 2026
GIANT brochure, Standard, Cascade and Super CascadeGI-PB019Fr-0726, July 2026 · 172STE wattage at 240 V, elements, coating, drain valve · consulted on November 9, 2026
GIANT, “Advantages of ECOPEAK” pagegiantinc.com · how the elements operate, hot water, cases advised against, billing · consulted on November 9, 2026
GIANT owner's manual supplement, “ECOPEAK Technology”GI-IM028En-0825, August 2025 · wiring, recommended wire and breaker, parts · consulted on November 9, 2026
GIANT owner's manualGI-IM017En-0726 · Table 1, drain pan, factory thermostat setting · consulted on November 9, 2026
Hydro-Québec, “Discover the water heater with ECOPEAK technology” pagehydroquebec.com, Energy Wise section · role of each element, peak periods 6 to 10 a.m. and 4 to 8 p.m., offer at participating partners · consulted on November 10, 2026
Hydro-Québec, Rate Flex D pagehydroquebec.com · peak events from 6 to 10 a.m. or 4 to 8 p.m., December 1 to March 31, 30 events at most · consulted on November 10, 2026
CanmetENERGY, Natural Resources Canada“Analyse du fonctionnement de chauffe-eau installés à Sherbrooke, Québec”, August 5, 2021 · 110 two-element and 12 three-element water heaters · consulted on November 9, 2026