Home / Comparisons / Water heaters
GIANT ECOPEAK and GIANT Standard, 60 gallons: three elements or two
Same 279 L tank, same dimensions, same listed standby loss. The difference is in the heating elements: three on the ECOPEAK, at 3,800, 3,000 and 800 W, against two 4,500 W elements on the Standard. GIANT says so itself: the ECOPEAK does not heat water faster. It draws less power at a time, and its full recovery takes longer.
Expert Plus ECOPEAK 172STPS
172STPS-3S8M · 240 V · 279 L
Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426, April 2026
See the product page
Standard 172STE
172STE-3F7M · 240 V · 279 L
Spec sheet GI-FT-RES-ELECT-STE-FR-0726, July 2026
See the product pageWhat each tank draws, hour by hour
A water heater does not know the time: its thermostats switch the elements on when the water cools or is drawn. Hydro-Québec, for its part, watches two periods on winter days, morning and evening. Move the time, then pick a type of draw: the elements that heat light up in each tank.
The bands are not measured running hours: no document gives any, and the thermostat stops each element once the water is at temperature. They show each element's wattage and the role the documents give it. Wattages: GIANT spec sheets of April and July 2026. Role of the elements: ECOPEAK sheet (note under the table), GIANT's “Advantages of ECOPEAK” page and Hydro-Québec's page on the ECOPEAK. On the Standard, the diagram lights the bottom element for a draw as an indication only: GIANT writes only that the two elements run alternately. Peak periods: Hydro-Québec, page on the ECOPEAK; the Rate Flex D page places peak events at the same hours, from December 1 to March 31. These hours can change.
As much hot water, a slower recovery
Both tanks hold 279 L. Per GIANT, the average user will see no difference in the amount of hot water. What changes is the time needed to reheat the whole tank once emptied: longer with three elements.
How many showers in one tank?
Basis: GIANT gives an average of 33 minutes of total showering for a 60-imperial-gallon water heater, with a 9.5 L/min showerhead, not counting recovery between showers. GIANT gives this figure for a 60-imperial-gallon water heater, the size of both tanks compared; the division is AirGreen's.When GIANT advises against the ECOPEAK
The manufacturer itself writes that an ECOPEAK should not be bought in four cases:
- a family of 5 or 6
- therapeutic baths
- several baths a day
- extra-long showers
Two product lines, not just one more element
The 60-gallon ECOPEAK belongs to the Expert Plus line; the 172STE compared here is from the Standard line. The spec sheets do not describe the tank, the anode or the drain valve the same way. Peak management, for its part, relies neither on hotter stored water nor on remote control: it comes down to the number of elements, their wattage and their wiring.
ECOPEAK 172STPSThree screw-in immersion elements, medium density, made by GIANT and CSA approved. GIANT describes the bottom one as very low density. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426; “Advantages of ECOPEAK” page
Standard 172STETwo square-flange immersion elements, made by GIANT and CSA approved. Brochure GI-PB019Fr-0726
ECOPEAK 172STPSTank lined with a coat of cobalt blue glass, enriched with zircon. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426
Standard 172STEGlass-lined tank; single internal anti-corrosion coating. Spec sheet GI-FT-RES-ELECT-STE-FR-0726; Brochure GI-PB019Fr-0726
ECOPEAK 172STPSOversized magnesium anode. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426
Standard 172STEMagnesium anode; the brochure calls it “normal”. Spec sheet GI-FT-RES-ELECT-STE-FR-0726; Brochure GI-PB019Fr-0726
ECOPEAK 172STPSBrass. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426
Standard 172STEPlastic. Brochure GI-PB019Fr-0726
ECOPEAK 172STPSThree thermostats, one per element; the top one is combined with the high-limit control. Factory setting: 60 °C on Canadian models. The ECOPEAK supplement describes no mixing valve, no electronic control and no link to the power grid. Supplement GI-IM028En-0825; manual GI-IM017En-0726
Standard 172STETwo thermostats; the top one is combined with the manual-reset high-limit control. Factory setting: 60 °C on Canadian models. Standard parts list, January 2025; manual GI-IM017En-0726
ECOPEAK 172STPS3/4 in NPT dielectric fittings and heat traps, factory installed. Spec sheet GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426
Standard 172STE3/4 in NPT dielectric fittings and heat traps, factory installed. Spec sheet GI-FT-RES-ELECT-STE-FR-0726
Same floor space, not the same circuit
Both tanks have the same dimensions and the same weight. The difference is on the electrical side: the ECOPEAK never draws more than 3,800 W, the Standard 4,500 W. GIANT writes that this lets a household go from a 40 to a 60-gallon ECOPEAK without changing the breaker or the wire size.


Manufacturer photos shown at the same height. Their width depends on the camera angle: for the diameter, rely on the listed dimensions.
| Measure | GIANT ECOPEAK 172STPS | GIANT Standard 172STE |
|---|---|---|
| Diameter × overall height | 24 in × 59 7/8 in61 cm diameter; for the height the sheet prints “(125)” cm, while 59 7/8 in is 152 cm | 24 in × 59 7/8 in61 × 152 cm |
| Shipping weight | 185 lb84 kg | 185 lb84 kg |
| Water connections | 3/4 in NPT, dielectric | 3/4 in NPT, dielectric |
| Voltages offered | 208 V or 240 V172STPS-2S8M and 172STPS-3S8M; April 2026 spec sheet | 120 V, 208 V or 240 Vbrochure GI-PB019Fr-0726: 1,500 W at 120 V, 4,500 W at 208 V and at 240 V |
| Recommended breaker at 240 V | 20 A, No. 12 wirefor 3,800 W; ECOPEAK supplement GI-IM028 | 25 A, No. 10 wirefor 4,500 W; manual GI-IM017, Table 1 |
| Drain pan | At least 2 in (5.0 cm) wider than the diameter, and 3 in (7.5 cm) deep | At least 2 in (5.0 cm) wider than the diameter, and 3 in (7.5 cm) deep |
What people ask about the ECOPEAK
Does a three-element water heater heat water faster?
No, and GIANT says so plainly. The ECOPEAK never draws more than 3,800 W, against 4,500 W for the 60-gallon Standard. Recovering the whole tank therefore takes longer than with two elements.
Does the ECOPEAK use less electricity?
GIANT writes that energy consumption is identical and that the bill does not change in Québec. A CanmetENERGY study in Sherbrooke even measured more energy on 12 three-element water heaters than on 110 two-element ones, without being able to explain it, and warning that the sample is small. What changes is the power drawn at a given moment.
What are Hydro-Québec's winter peak hours?
Its page on the ECOPEAK places peak periods in the morning, from 6 to 10 a.m., and in the evening, from 4 to 8 p.m. The Rate Flex D page puts peak events at the same hours, from December 1 to March 31, with a maximum of 30 events per winter. Pages consulted on November 10, 2026; these hours can change.
Does Hydro-Québec have a program tied to the ECOPEAK?
Hydro-Québec has a page on the ECOPEAK and mentions there a purchase offer at participating partners, under certain conditions, noting that it may end the offer at its discretion. The conditions and the list of partners are on its site. This information, noted on November 10, 2026, can change; AirGreen promises no amount.
Will I have less hot water with an ECOPEAK?
Both tanks hold 279 L. GIANT writes that the average user will see no difference, but advises against the ECOPEAK for families of 5 or 6 and for people who take therapeutic baths, several baths a day or extra-long showers.
Is a different breaker needed?
GIANT's manuals list 20 A and No. 12 wire for 3,800 W at 240 V, the ECOPEAK's maximum power, and 25 A and No. 10 wire for 4,500 W, the Standard's. It is up to an electrician to check the existing circuit.
Are the two tanks the same size?
Yes: 279 L, 24 in diameter, 59 7/8 in tall and 185 lb shipping weight, per both spec sheets. The listed standby loss is also the same, 78 W.
Why does this page not compare warranties?
A warranty has to be read in full, with its conditions and exclusions. Each unit's warranty documents are provided with the quote.
Every published value, side by side
| Measure | GIANT ECOPEAK 172STPS | GIANT Standard 172STE |
|---|---|---|
| Volume | ||
| Tank volume | 279 L61 imp. gal, 74 US gal | 279 L61 imp. gal, 74 US gal |
| Heating elements | ||
| Heating elements | 3, screw-in, medium density | 2, square flange |
| Top element | 3,800 W | 4,500 W |
| Middle element | 3,000 W | Not applicabletwo-element tank |
| Bottom element | 800 W | 4,500 W |
| Maximum power drawn | 3,800 Wthe top alone, or the middle and bottom together | 4,500 Wone element at a time |
| Losses | ||
| Standby loss | 78 W | 78 W |
| Construction | ||
| Tank and lining | Cobalt blue glass, enriched with zircon | Glass-lined tank, single internal coating |
| Anode | Magnesium, oversized | Magnesium |
| Drain valve | Brass | Plastic |
| Temperature and controls | ||
| Thermostats | 3one per element | 2one per element |
| Factory thermostat setting | 60 °C140 °F, Canadian models | 60 °C140 °F, Canadian models |
| Dimensions and installation | ||
| Diameter × overall height | 24 in × 59 7/8 in61 cm diameter; for the height the sheet prints “(125)” cm, while 59 7/8 in is 152 cm | 24 in × 59 7/8 in61 × 152 cm |
| Shipping weight | 185 lb84 kg | 185 lb84 kg |
| Recommended breaker at 240 V | 20 A, No. 12 wirefor 3,800 W; ECOPEAK supplement GI-IM028 | 25 A, No. 10 wirefor 4,500 W; manual GI-IM017, Table 1 |
| Documents | ||
| Spec sheet | GI-FT-RES-ELECT-STPS-EXPERT-PLUS-6-FR-0426April 2026 | GI-FT-RES-ELECT-STE-FR-0726July 2026 |
| Installation manual | GI-IM017En-0726 and supplement GI-IM028En-0825 | GI-IM017En-0726 |
Bars on the same row share the same scale. No value is highlighted: higher wattage reheats the tank faster, lower wattage asks less of the grid.
Both are on the AirGreen site.
To choose for your home, talk it over with our team: the number of people, your hot water habits and the existing electrical circuit matter as much as the figures.
Where each figure comes from
Data verified on November 10, 2026. Volumes, wattages, standby loss, dimensions and weight: GIANT spec sheets. How the elements operate and hot water available: ECOPEAK sheet, GIANT's “Advantages of ECOPEAK” page and Hydro-Québec's page on the ECOPEAK. Thermostat setting: owner's manual. The April 2026 ECOPEAK sheet lists models 172STPS-2S8M and 172STPS-3S8M; the July 2026 Standard sheet lists the 172STE-2F7M (208 V), with the brochure and parts list also giving the 172STE at 240 V.
Trademarks. GIANT, ECOPEAK and Expert Plus are trademarks of their owner. Hydro-Québec is cited as the source of the peak periods and of its description of the ECOPEAK. Logos are used only to identify the products compared. AirGreen is a dealer for the brand; this page is not produced, sponsored or approved by the manufacturer or by Hydro-Québec.
Photos: AirGreen and manufacturer, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca: every figure reported is checked again.