Heat pump or electric water heater in Québec
An electric water heater heats water with elements immersed in the tank. A heat pump water heater first takes heat from the air of the room it stands in, and keeps elements as backup. This guide shows where that heat comes from, what it changes in a Québec basement in winter, and what the unit needs: space, a volume of air and a drain.
BRADFORD WHITE AeroTherm RE2H50S10
RE2H50S10-1NCTT · 240 V · 189 L
Spec sheet C1902-0725 CANADA, July 2025
See the product page
BRADFORD WHITE RE250T6
RE250T6-1NCPP · 240 V · 178 L
Spec sheet C1201-0926 CANADA, September 2026
See the product pageWhere the heat comes from, and where the cooled air goes
In both cases the water heats in a tank. The difference is where the heat comes from. Pick the type of unit and the season, then move the room air temperature.
Heat pump example: what its manual prints
BRADFORD WHITE AeroTherm RE2H50S10
- Room air enters through the top of the unit, across a washable filter.Manual 238-52169-00C
- At least 20.3 cm (8 in) clear above, to remove the filter.Manual 238-52169-00C
- The air leaves at the rear, cooled. If the room air drops by more than 8 °C (15 °F) during heating, the manual considers air circulation insufficient and points to a ducting kit.Manual 238-52169-00C
- Condensate leaves through a 3/4 in fitting to a drain no higher than 91.4 cm (36 in) above the floor. With no drain, a condensate pump of at least 3.8 L per day.Manual 238-52169-00C
- Room of 19.8 m³ (700 ft³) or more. Otherwise: a louvered door with 0.15 m² (240 in²) of open area, or a ducting kit.Manual 238-52169-00C
- The heat pump runs when room air is between 2 and 49 °C. Outside that range, the electric elements take over.Spec sheet C1902-0725 CANADA; Manual 238-52169-00C
- 17.5 cm (7 in) recommended at the rear and on the right side; the rear must not discharge against a wall.Manual 238-52169-00C
Electric example: what its manual prints
BRADFORD WHITE RE250T6
- Two 4,500 W immersed elements heat the water, one at a time.Spec sheet C1201-0926 CANADA
- 45.7 cm (18 in) recommended above and 61 cm (24 in) in front, for servicing. Minimum clearance to combustible material: 0 in.Manual 238-44422-00Z
- The manual asks for neither an air volume nor a condensate drain: the unit does not exchange air with the room to heat.Manual 238-44422-00Z
- Where a leak would cause damage: a drain pan at least 10.2 cm (4 in) wider than the diameter, piped to a drain.Manual 238-44422-00Z
- Level floor, protected from freezing, close to a power supply and the water lines.Manual 238-44422-00Z
Diagram drawn to scale for the heights and diameters of the two examples (spec sheets); the room itself is illustrative. Operation and requirements: BRADFORD WHITE manuals 238-52169-00C and 238-44422-00Z. Context: Natural Resources Canada, “Guide sur les chauffe-eau” (Water Heater Guide), p. 15.
Space, air and a drain
The electric example's manual asks for no air volume. A heat pump water heater, for its part, needs air around it: that is its heat source. The example's manual gives a figure for the room volume; check yours.
Does your room have the required volume?
Heat pump example19.8 m³ (700 ft³) or more. Below that: a louvered door or two louvered sections, with 0.15 m² (240 in²) of open area, or a ducting kit (23 m of duct at most, inlet and outlet combined). Manual 238-52169-00C; Spec sheet C1902-0725 CANADA
Electric exampleNo air volume asked for by the manual. Manual 238-44422-00Z
Heat pump example17.5 cm (7 in) recommended at the rear and on the right side; 20.3 cm (8 in) above for the filter; clear front. A confined space increases the use of the elements, per the manual. Manual 238-52169-00C
Electric exampleMinimum clearance of 0 in to combustible material; 45.7 cm (18 in) above and 61 cm (24 in) in front recommended for servicing. Manual 238-44422-00Z
Heat pump example3/4 in condensate fitting; a floor drain or one no higher than 91.4 cm (36 in), with a continuous slope. With no drain: a condensate pump of at least 3.8 L per day. Manual 238-52169-00C
Electric exampleNo condensate: the unit does not remove humidity from the air. Manual 238-44422-00Z
Heat pump example2 to 49 °C (35 to 120 °F). Outside that range, the heat pump stops and the elements heat until the air is back within range. Spec sheet C1902-0725 CANADA; Manual 238-52169-00C
Electric exampleNo ambient air range for heating; the unit and its piping must stay protected from freezing. Manual 238-44422-00Z
Heat pump exampleWashable filter on top; a light and an alarm signal when to clean it. If it gets too dirty, the unit switches to Electric (Only) mode. Manual 238-52169-00C
Electric exampleNo air filter. Manual 238-44422-00Z
Heat pump exampleWhere a leak would cause damage: a pan at least 10.2 cm (4 in) larger than the base diameter. Manual 238-52169-00C
Electric exampleSame requirement: at least 10.2 cm (4 in) wider than the diameter, piped to a drain. Manual 238-44422-00Z
A comparable first hour, a slower recovery on the compressor alone
The two examples have tanks in the same class: 189 L and 178 L. Their first-hour ratings are close, 246 L and 242 L. The gap is in recovery: on the compressor alone, the heat pump example reheats 23 L per hour; the electric example, 79 L per hour.
Litres reheated per hour, for a 50 °C rise
The modes of the heat pump example
The unit picks its heat source according to the mode. The electric example has only one way of heating.
One certified figure, and the conditions under which it is measured
The heat pump of a heat pump water heater does not turn electricity into heat: it uses it to move heat from the air to the water. Its efficiency is expressed by the Uniform Energy Factor (UEF). In Canada, that of an electric storage water heater is instead expressed by its standby loss, in watts.
UEF of 3.44: for 1 part of electricity, 3.44 parts of heat in the water delivered
Standby loss of 63 W; UEF not published on the Canadian spec sheet
Two units of the same brand, side by side
To compare types rather than brands, both examples come from the same manufacturer and the same tank class, known as 50 US gallons. They are almost the same height; the heat pump example also asks for 20.3 cm clear above it. Both are sold by AirGreen. Other models exist in each type.


Manufacturer photos shown at the same height scale. Their width depends on the camera angle: for the diameter, rely on the listed dimensions.
| Measure | Heat pump example · AeroTherm RE2H50S10 | Electric example · RE250T6 |
|---|---|---|
| Tank | ||
| Tank volume | 189 L50 US gal, 42 imp. gal | 178 L47 US gal, 39 imp. gal |
| Diameter × overall height | 21 3/4 in × 59 3/16 in552 × 1,503 mm | 20 in × 59 in508 × 1,499 mm |
| Shipping weight | 195 lb88 kg | 130 lb59 kg |
| What heats | ||
| Compressor | 500 W | Not applicableno heat pump |
| Heating elements | 2 × 4,000 W at 240 V3,000 W at 208 V; one at a time | 2 × 4,500 W at 240 Vone at a time |
| Refrigerant | R-134a29.1 oz | Not applicable |
| Hot water | ||
| First-hour rating | 246 L65 US gal | 242 L64 US gal |
| Recovery at a 50 °C rise | 23 L/h, compressor only91 L/h, compressor and element | 79 L/h |
| Efficiency | ||
| Uniform Energy Factor (UEF) | 3.44 | Not published by the manufacturerCanadian spec sheet |
| Standby loss | Not published by the manufacturer | 63 W |
| Settings and sound | ||
| Factory temperature setting | 49 °C120 °F, Hybrid mode; adjustable from 38 to 60 °C | 60 °C140 °F, in Canada |
| Sound level | Not published by the manufacturerthe manual mentions a fan that can be heard when running | Not published by the manufacturer |
| Electrical and plumbing | ||
| Voltage | 240 V or 208 V | 240 Vfactory wiring; other voltages to order |
| Recommended breaker | 25 A minimum | 25 Arecommended fuse for 4,500 W at 240 V |
| Water connections | 3/4 in NPT | 3/4 in NPT |
| Documents | ||
| Spec sheet | C1902-0725 CANADAJuly 2025 | C1201-0926 CANADASeptember 2026 |
| Installation manual | 238-52169-00CFebruary 2022 | 238-44422-00ZJanuary 2024 |
What people ask before choosing
Does a heat pump water heater cool the basement?
Yes, when the heat pump runs: it takes heat from the air and discharges cooled air. The example's manual states that if the room air drops by more than 8 °C during heating, air circulation is insufficient and a ducting kit can direct the cold air elsewhere.
Does it work in a cold basement?
The example's heat pump runs when room air is between 2 and 49 °C. Outside that range it stops and the electric elements heat the water until the air is back within range.
Is it advantageous in winter in Québec?
Natural Resources Canada writes that heat pump water heaters are less advantageous in winter, when rooms have to be heated, and that they can be cost-effective in milder climates. This page puts no figure on it: the documents consulted do not measure that case for a Québec home.
Is a drain needed?
Yes for the heat pump example: the humidity removed from the air runs through a 3/4 in fitting to a drain no higher than 91.4 cm above the floor. With no drain, the manual calls for a condensate pump of at least 3.8 L per day. The electric example produces no condensate.
How big a room is needed?
The example's manual asks for 19.8 m³ (700 ft³), that is a 10 ft by 10 ft room with a 7 ft ceiling. In a smaller room, it calls for a louvered door with 0.15 m² of open area, two louvered sections, or a ducting kit.
Will I have less hot water?
The first-hour ratings of the two examples are close: 246 L for the heat pump unit, 242 L for the electric one. Recovery differs: 23 L per hour on the compressor alone, 91 L per hour with the compressor and an element, 79 L per hour for the electric example.
Is it noisy?
The heat pump example's manual says a fan can be heard when the heat pump runs; it publishes no sound level. The electric example has no fan.
Why does this page not compare warranties?
A warranty has to be read in full, with its conditions and exclusions. Each unit's warranty documents are provided with the quote.
Both are on the AirGreen site.
To find out which one suits your home, talk it over with our team: the room, the drain, the electrical circuit and your hot water habits matter as much as the figures.
Where each figure comes from
Data verified on November 10, 2026. This guide compares two types of units; the two models named are examples, chosen among those AirGreen sells, from the same manufacturer and in the same tank class. It names no type as preferable. Information drawn from codes and government pages is cited as of its date and can change.
Trademarks. BRADFORD WHITE and AeroTherm are trademarks of their owner. ENERGY STAR is a trademark of its owner. Logos are used only to identify the products given as examples. AirGreen is a dealer for the brand; this page is not produced, sponsored or approved by the manufacturer, by Natural Resources Canada or by the Régie du bâtiment du Québec.