Cooling operating range: down to what temperature

Comparison · Guide · Cooling

Cooling operating range: down to what temperature

A server room, a sunroom in full sun, a restaurant kitchen: some rooms need cooling when it is cold outside. Each manufacturer documents an outdoor temperature range for cooling, as it does for heating. They are not the same.

4 12,000 BTU modelsLow limit from 14 to −20 °FSources: manufacturer documents
FUJITSU AIRSTAGE ORION XLTH 12,000 BTUFUJITSU AIRSTAGEORION XLTHASUH12KZAS / AOUH12KZAH1 · AHRI 214888802See the product page
GREE EXTRÊME R32 12,000 BTUGREEEXTRÊME R32GWH12AVDXE-D6DN***/I / GWH12AVDXE-D6DNA1B/O · AHRI 215386290See the product page
SAMSUNG WindFree MaxHeat 12,000 BTUSAMSUNGWindFree MaxHeatAR12DXDABWKN / AR12DXDACWKX · AHRI 215399291See the product page
HITACHI airHome 800 12,000 BTUHITACHIairHome 800RAK-XJ12PHAA / RAC-XJ12WHAA · AHRI 215911631See the product page

Four models AirGreen offers, used as examples. The page shows what each manufacturer documents; it ranks no model.

Cooling when it is cold outside

Pick an outdoor temperature

Each solid bar is the cooling range the manufacturer documents; the hatched band above it, its heating range. The yellow line follows your temperature.

−15 °C
documented cooling rangedocumented heating rangeyour temperature
Read this before drawing conclusions. A documented range says how far the manufacturer expects the unit to cool. None of the documents consulted gives the cooling capacity near the low limit, and the AHRI certificate measures cooling only at 95 °F and 82 °F.
What the certificate covers

In cooling, only two points, both in hot weather

Documented range and certified points

The NEEP records of the four examples publish cooling at 95 °F (35 °C) and 82 °F (27.8 °C). The manufacturers' ranges go much lower, from 14 to −20 °F. Between the low limit and 82 °F, there is no certified cooling capacity value.

SEER2 and EER2 come from these hot-weather tests. They do not describe cooling in cold weather.

Three rooms

What the documents let you check

Server room or equipment room

These rooms make heat all year. The documented range shows whether the manufacturer expects cooling on the coldest days; the documents consulted say nothing about continuous duty or redundancy.

Sunroom

Sun can warm a glassed-in room in late winter. Compare the outdoor temperature on those days with each model's low cooling limit.

Kitchen

Cooking and appliances give off heat even in the cold season. The range says whether cooling is expected at those temperatures; it does not say what capacity the room needs.

The values

The documented ranges, model by model

Ranges: manufacturer documents, cooling and heating columns, outdoor temperature. Capacity at 95 °F: certified rated value, NEEP record. Read each column on its own; no row is a ranking.

Frequently asked questions

What we get asked about cooling in cold weather

Can a wall heat pump cool when it is 14 °F outside?

According to the manufacturers' documents, all four examples expect cooling at 14 °F. Below that the limits differ: 0 °F (WindFree MaxHeat), −4 °F (airHome 800), −20 °F (EXTRÊME R32); the ORION XLTH stops at 14 °F.

Is the cooling range certified?

No. It comes from the manufacturer. The AHRI certificate, published by NEEP, measures cooling at 95 °F and 82 °F only.

Is an accessory needed for cold-weather cooling?

The documents consulted for these four models mention no low-ambient cooling accessory. The ranges shown are those of the sheets, with no accessory named.

Why isn't the cooling limit the same as the heating limit?

Manufacturers publish two separate ranges. The ORION XLTH, for example, heats down to −15 °F according to FUJITSU AIRSTAGE, but its cooling range stops at 14 °F.

And the high limit, in a heat wave?

The sheets give 122 °F for the ORION XLTH and the EXTRÊME R32, 115 °F for the WindFree MaxHeat and the airHome 800. All four cover Montréal summer temperatures.

A room to cool all year?