ENERGY STAR Cold Climate: what the designation says, and what it doesn't

Comparison · Guide · ENERGY STAR Cold Climate

ENERGY STAR Cold Climate: what the designation says, and what it doesn't

Many people read "cold climate" as "heats down to −30 °C (−22 °F)". The ENERGY STAR specification in force checks something else: efficiency and capacity at a single temperature, 5 °F (−15 °C). Here are the criteria, where they are measured, and two real heat pumps taken through them one by one.

Specification v6.2, rev. February 2026Test at 5 °F (−15 °C)COP ≥ 1.75Capacity ≥ 70% of that at 47 °F

Cold Climate criteria of the ENERGY STAR v6.2 specification (rev. February 2026), pp. 4–5: COP and capacity measured at 5 °F, H4₂ test of Appendix M1.

Example FUJITSU AIRSTAGE ORION XLTH 12,000 BTU FUJITSU AIRSTAGE ORION XLTH

ORION XLTH, 12,000 BTU

ASUH12KZAS / AOUH12KZAH1 · AHRI 214888802 Cold Climate designation: yes (ENERGY STAR directory) See the product page
Example SAMSUNG WindFree Standard 12,000 BTU SAMSUNG WindFree Standard

WindFree Standard, 12,000 BTU

AR12DXFAMWKN / AR12DXFAMWKX · AHRI 215399297 Cold Climate designation: no (ENERGY STAR directory) See the product page

Two examples taken from the models AirGreen offers, to illustrate the criteria. Both are ENERGY STAR certified; the page makes no judgment on either.

The criteria in force

Two levels: the label, then the Cold Climate designation

The ENERGY STAR v6.2 heat pump specification (revision of February 2, 2026) first sets thresholds for the label. A model can then receive the Cold Climate designation if it clears other thresholds, plus a test at 5 °F. For a ductless wall unit, here are both lists.

ENERGY STAR label, split system

Table 1, p. 4

SEER2seasonal cooling efficiency≥ 15.2
EER2cooling efficiency at 95 °F≥ 11.0
HSPF2seasonal heating efficiency, Region IV≥ 7.8

Cold Climate designation, ductless split

Table 2 and low-ambient performance, pp. 4–5

SEER2same threshold as the label≥ 15.2
HSPF2Region IV; 8.1 for a ducted system≥ 8.5
COP at 5 °F (−15 °C)Appendix M1 H4₂ test≥ 1.75
Capacity at 5 °F ÷ capacity at 47 °F47 °F: nominal capacity, compressor at the maximum speed its controls use at 47 °F≥ 70%
Controls verification (CVP)the 5 °F values must be reached by the native controls, as in a homeperformed

Source: ENERGY STAR Program Requirements for Heat Pumps, Version 6.2 (rev. February 2026), Tables 1 and 2, p. 4; low-ambient performance and CVP, pp. 4–5; HSPF2 definition (Region IV), p. 2. Criteria can change: check the version in force.

The conditions of the designation

Two real heat pumps, one criterion at a time

Each bar starts at zero and stops at the value published in the ENERGY STAR directory; the dark tick marks the threshold. Choose the list to check.

FUJITSU AIRSTAGE ORION XLTH 12,000 BTU · exampleSAMSUNG WindFree Standard 12,000 BTU · example
Read this before drawing conclusions. Both models carry the ENERGY STAR label. On the Cold Climate list, the WindFree Standard clears SEER2, HSPF2 and the COP at 5 °F; its capacity ratio, calculated from the directory values (8,000 ÷ 12,000 BTU/h), comes to 67%, below the 70% threshold. ENERGY STAR does not publish a reason per model: this calculation is ours, made with its own figures.
The test temperature

What each document says, degree by degree

The Cold Climate criteria stop at 5 °F. The NEEP records of the two examples go lower, each at its own temperature. Pick a point: you see what the criteria say, then the published value for each heat pump.

NEEP values: maximum capacity and matching COP, records 392122 and 389381, read November 10, 2026. Between two published points nothing is measured: the page shows the two values on either side, each with its own temperature.

What it doesn't say

Six things the designation does not promise

1Anything colder than 5 °F

COP and capacity are checked at 5 °F. The specification has no criterion at −4, −13 or −22 °F.

2An operating limit

No minimum temperature is set. Each manufacturer publishes its own: −15 °F with no lockout for the ORION XLTH, −5 °F for the WindFree Standard.

3Montréal's climate

The HSPF2 threshold is defined in Region IV. HSPF2 Region V, closer to our winters, is not part of the criteria; our cost estimates use it.

4A ranking

It is a yes or a no. Two designated models can have very different capacities at 5 °F, and a model without it remains ENERGY STAR certified.

5Sound, defrost, installation

The criteria do not cover sound levels, defrost, snow or where the outdoor unit goes.

6That the rules stay the same

Version 6.2 was revised in February 2026. In the U.S., management of the program is moving from the EPA to the DOE in 2026; in Canada, NRCan administers it. Criteria can change.

The published values

The two examples, as the directory publishes them

ValueFUJITSU AIRSTAGE ORION XLTHSAMSUNG WindFree Standard
ENERGY STAR directory
ENERGY STAR Cold Climate designationYesNo
SEER230.524
EER21613.25
HSPF2 (Region IV)12.79
Heating capacity at 47 °F (8.3 °C)16,000 BTU/h12,000 BTU/h
Heating capacity at 5 °F (−15 °C)16,600 BTU/h8,000 BTU/h
Capacity at 5 °F, as a % of that at 47 °FAirGreen calculation from the two rows above104%67%
COP at 5 °F (−15 °C)2.161.76
Controls verification (CVP)ENERGY STAR CVP TestENERGY STAR CVP Test
RefrigerantR-32R-32
AHRI certificate · NEEP record214888802 · 392122215399297 · 389381
ENERGY STAR certification dateApril 17, 2026January 7, 2026
NEEP: coldest published point
Coldest published point−15 °F (−26.1 °C): 12,200 BTU/h max., COP 1.81−5 °F (−20.6 °C): 10,000 BTU/h max., COP 1.81

higher marks the higher value of the same measure under the same conditions. It is not a recommendation. No row is marked here: the page illustrates criteria, it does not compare the two models.

Frequently asked questions

What we get asked about the designation

Does "cold climate" mean the heat pump heats at −22 °F?

No. The criteria check COP and capacity at 5 °F, nothing colder. The temperature down to which a heat pump runs comes from the manufacturer, and colder certified points, when there are any, come from the model's NEEP record.

Why doesn't the WindFree Standard have the designation, with a COP of 1.76 at 5 °F?

COP is only one of the criteria. Using the values published in the directory, its capacity at 5 °F is 67% of the capacity at 47 °F, and the threshold is 70%. ENERGY STAR does not state a reason for a given model; this calculation is ours.

Is a heat pump without the designation less efficient?

The designation does not measure overall efficiency. Both examples carry the ENERGY STAR label, and the WindFree Standard clears the SEER2 and HSPF2 thresholds of the Cold Climate list. To compare efficiency, compare the same measures under the same conditions, on the certificates.

Where can I check a model's designation?

In the public ENERGY STAR directory, using the AHRI certificate number or the model numbers. The NEEP record of the same certificate also shows an "ENERGY STAR Cold Climate" field; for both examples it matched the directory on November 10, 2026.

Is the 8.5 HSPF2 threshold measured for Québec?

The specification defines HSPF2 in Region IV. NEEP records also publish HSPF2 Region V, a colder region; it is not part of the ENERGY STAR criteria. Our guide to Regions IV and V explains the difference.

Can the criteria change?

Yes. Version 6.2 was revised on February 2, 2026, and management of the program in the U.S. is moving from the EPA to the DOE in 2026. This page cites the version read on November 10, 2026.