"Down to −22 °F": stated range and certified point
For the same heat pump, two figures circulate. The manufacturer states the outdoor temperature down to which it heats. The NEEP record certifies how much heat it delivers, and at what efficiency, at its coldest point. These are not the same questions.
The lowest outdoor temperature at which the manufacturer says the unit heats.
The heating capacity and COP measured at a given temperature, published on the NEEP record of the AHRI certificate.
Four models already shown on our comparison pages, used as examples. AirGreen offers all four; the page ranks none of them.
Four thermometers, two kinds of figures
Left of the tube, the heating range stated by the manufacturer. On the tube, the published points: solid dots for NEEP certified points, diamonds for manufacturer values. Tap a point to see its source.
NEEP values: maximum capacity published at each temperature, read November 10, 2026. The top of the ranges (75 to 86 °F) is beyond the scale and not drawn.
The range says how cold, the point says how much
How cold: the stated range
It comes from the manufacturer's spec sheet or website. It states an operating limit without saying how much heat comes out at that limit. Three of the four examples state −22 °F; the fourth, −15 °F.
How much: the certified point
It comes from the NEEP record of the AHRI certificate: a maximum capacity and a COP, at a precise temperature. At the four coldest published points, maximum capacity ranges from 6,000 to 12,200 BTU/h, and the temperatures are not all the same.
What each record publishes at its own limit
One row per question, one column per model. The percentage is an AirGreen calculation: maximum capacity at the coldest point, divided by the same model's certified rated capacity at 47 °F.
Read each column on its own: the coldest points are not all at the same temperature, and no row is a ranking.
Three documents, three answers
Look for "operating range", heating column. Note the temperature, the document date and any mention of an automatic shutdown.
Open the heating values and go down to the coldest row: temperature, maximum capacity, COP.
Some manufacturers publish their own capacities below 5 °F. HITACHI gives 13,500, 10,500 and 6,000 BTU/h at −4, −13 and −22 °F for the 12,000 BTU airHome 800.
Two values taken at different temperatures do not tell you which one heats more. Our NEEP record guide explains each column.
What we get asked about "down to −22 °F"
If the range goes down to −22 °F, does the heat pump heat as much as at 5 °F?
Not necessarily. For the three examples certified at −22 °F, the maximum capacity published there is lower than at 5 °F: 8,500 vs 12,200 BTU/h (EXTRÊME R32), 6,800 vs 9,000 (WindFree MaxHeat), 6,000 vs 15,200 (airHome 800).
Why isn't the coldest point at the same temperature for all of them?
The NEEP record publishes a point colder than 5 °F whose temperature varies from model to model: −15 °F for the ORION XLTH, −22 °F for the other three examples. That is why the page does not set them side by side as a ranking.
What happens below the stated limit?
FUJITSU AIRSTAGE states there is no lockout on the ORION XLTH, without giving a capacity below −15 °F. The documents consulted for the other three do not say.
Do the HITACHI sheet and the NEEP record agree at −22 °F?
For the 12,000 BTU airHome 800, yes: 6,000 BTU/h in both. At −4 and −13 °F, only the manufacturer's sheet publishes a value; it is marked as such.
Which figure should I look at for a home in Montréal?
Both, because they answer different questions. The design temperature used in our estimates for Montréal is −23.1 °C (−9.6 °F) (NRCan, HOT2000). Our sizing guide explains how these figures feed into choosing a capacity.
A product listing title says "−30 °C". Where does that figure come from?
It repeats the lower limit of the heating range stated by the manufacturer, as for the airHome 800 and the WindFree MaxHeat. The heat available at that temperature is on the NEEP record.
A question about a model's limit?
AirGreen offers the four heat pumps used as examples on this page.
Sources
Data verified November 10, 2026. Ranges come from the manufacturers' documents; certified points from the NEEP records of the AHRI certificates. The percentage of rated capacity is an AirGreen calculation.
FUJITSU AIRSTAGE, ORION, GREE, EXTRÊME, SAMSUNG, WindFree, Max Heat, HITACHI and airHome are trademarks of their respective owners. Names and images are used only to identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong to you? Write to us at sales@airgreen.ca.