KINGHOME POLARIS R32 and SHARP CHU R32, 12,000 BTU

Home / Comparisons / 12,000 BTU wall heat pumps

Comparison · Wall heat pump · 12,000 BTU

KINGHOME POLARIS R32 and SHARP CHU R32: how far each one slows down, how far it pushes

Two 12,000 BTU R-32 wall units, ENERGY STAR cold-climate certified, certified by NEEP down to −30 °C. A sheet often shows a single figure; NEEP publishes two at each temperature: the minimum and the maximum. In between, the heat pump modulates. This page compares those two bands, step by step.

At 8.3 °C : 3,070 to 17,060 and 3,100 to 22,850 BTU/hAt −30 °C : 2,000 to 7,300 and 1,350 to 9,700 BTU/hSEER2 25.5 and 25HSPF2 Region V 8 and 9
POLARIS CHU 24,000 BTU/h0

At 8.3 °C, from the minimum to the maximum certified by NEEP, same scale.

Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.

The modulation band

Does your room ask for more, or less, than each band?

A variable-speed heat pump adjusts its output between a minimum and a maximum. Below the minimum, it cannot slow down any further and has to stop and start again; above the maximum, it is no longer enough on its own. Slide the room’s heating (or cooling) load: at each certified temperature, the page shows where it falls in each band.

POLARIS R32: from certified minimum to maximumCHU R32: from certified minimum to maximumyellow tick: certified rated capacitychosen load

NEEP certified values, at each test temperature; nothing is drawn between two temperatures. At −30 °C, NEEP publishes the minimum and the maximum, with no rated value. A room’s real load is calculated for the house: the page does no sizing.

At low speed, efficiency changes too

NEEP publishes the COP measured at the minimum and the maximum of each band. A COP of 3 means 3 kWh of heat for 1 kWh of electricity. The bars start at 0 and use the same scale for both.

Reading: at 8.3 °C, both are more efficient at low speed than at full output. At −30 °C, the order flips for the CHU: COP 1.07 at minimum, 1.80 at maximum. The POLARIS keeps the usual order, 2.79 at minimum and 1.51 at maximum. NEEP, records 426104 and 507383.

What the two bands show. The CHU is certified higher at maximum at every heating temperature: 22,850 against 17,060 BTU/h at 8.3 °C, 9,700 against 7,300 at −30 °C. At minimum, the order changes with the point: at 8.3 °C, 3,070 for the POLARIS and 3,100 for the CHU; at −8.3 °C, 2,700 against 5,000; at −30 °C, 2,000 against 1,350. The KINGHOME sheet lists a heating range of 3,071 to 17,060 BTU/h, which matches the certified point at 8.3 °C.
Extreme cold

Below −15 °C: every published number, at its exact temperature

Both are certified at the same temperatures, −15 °C and −30 °C: 13,700 and 16,000 BTU/h maximum at −15 °C, 7,300 and 9,700 BTU/h at −30 °C. In between, SHARP publishes four points; KINGHOME publishes none.

What each manufacturer publishes below −15 °C. KINGHOME: the POLARIS sheet lists heating from −30 to 30 °C and repeats the certified points; it gives no capacity table lower down. The cells between −15 and −30 °C therefore show the two certified values on either side of each temperature. SHARP: the submittal gives the maximum capacity at −20, −25, −27.2 and −30 °C, and states that heating stops at −30 °C.
Documented features

What each manufacturer writes, group by group

KINGHOME: POLARIS R32 technical sheet (manufacturer documentation distributed by AirGreen). SHARP: brochure MNSPLT-CHUCU 1.1.1 and submittal AE-X12CHU_AY-XP12CHU-EN1.

Air distribution and louver

POLARIS : 3D airflow control, named without a description.

CHU : SHARP names four air-direction functions: an automatic louver that sweeps in four directions, the Coanda effect (warm air down, cool air up), Spot Air and Multi Space.

Fan and airflows

POLARIS : 182 to 424 CFM; airflow by speed not published.

CHU : five airflows published per season, with no speed names: from 212 to 636 CFM in heating, from 212 to 597 in cooling.

Modes

POLARIS : Turbo (fan at maximum); G-AI, an artificial-intelligence inverter control according to KINGHOME.

CHU : Full Power pushes the unit to maximum; Eco runs it with lower consumption than usual, according to SHARP; the 10 °C function keeps the room above freezing; OD Silent lowers the outdoor unit’s noise.

Controls and Wi-Fi

POLARIS : Wi-Fi and app control, named without an app name.

CHU : the submittal lists a built-in Wi-Fi adapter; the brochure shows a wireless remote.

Occupancy and humidity

POLARIS : humidity control, named without a description; occupancy sensor not published.

CHU : a motion sensor lowers heating or cooling when nobody moves in the room, then restores the setting on return, per the brochure; no humidity function published.

Maintenance and cleaning

POLARIS : smart cleaning: removes impurities and helps spot mechanical problems, according to KINGHOME.

CHU : After Care dries the inside of the unit after it stops, to limit mould and odours according to SHARP.

Extreme cold and outdoor unit

POLARIS : heating listed down to −30 °C; heated pan not mentioned in the sheet.

CHU : Hot Gas Pipe, which uses heat from the heating cycle so the outdoor unit does not freeze; heating stops at −30 °C per the submittal.

Restart and timer

POLARIS : not published in the sheet.

CHU : resumes its settings after a power cut; 24 h on/off timer, plus a quick off after 1, 2, 3 or 5 h.

Compressor

POLARIS : triple rotary.

CHU : a single rotor (Single Rotary), per the submittal.

Sound

Two extremes on one side, five speeds on the other

The modulation band also shows up for the ear: the KINGHOME sheet gives only the two ends, the lowest and highest level of the indoor unit, while SHARP publishes a level for each of its five airflows. Neither describes its test conditions.

dB(A)

How to read these numbers. dB(A) measures a noise level the way the ear perceives it: the lower the number, the quieter the unit. Each dot is a published value, from lowest to highest.

Why this is not a ranking. The methods are not described, and the airflows differ: 182 to 424 CFM for the POLARIS, 212 to 636 for the CHU in heating. A second KINGHOME document gives 37 to 57 dB(A) for the POLARIS; KINGHOME does not explain the gap.

Indoor unit

Published values

Outdoor unit, outside

Published values

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Installation

On the wall, outside and in between

Is your wall wide enough?

110 cm
Indoor unit KWP12R32C3I

Indoor unit AY-XP12CHU

0 cm160 cm, width of the strip

Photos scaled to the published width: 35.6 in (904 mm) for the POLARIS, 1,052 mm (41 7/16 in) for the CHU. The yellow band flags a wall narrower than the unit. Clearances around the indoor unit are not counted: SHARP publishes none online for this model.

InstallationPOLARIS R32CHU R32
Maximum piping length131 ftMinimum 10 ft66 ftMinimum 10 ft
Precharged length25 ft25 ftBeyond that: 0.16 oz per ft
Maximum height differenceNot published by the manufacturer33 ft
Liquid – gas diameters1/4 – 1/2 in1/4 – 3/8 in
Outdoor unit W × H × D, weight34 3/8 × 21 27/32 × 14 51/64 in, 81.6 lb30.7 × 21.3 × 10.6 in, 66.1 lb780 × 540 × 269 mm, 30 kg
Indoor unit, weight20.9 lb35.6 × 10.9 × 8.2 in30.9 lb14 kg; 1,052 × 316 × 249 mm
Electrical protectionMCA 13 A; maximum protection (MOCP) 15 AMCA 15 A; maximum fuse 20 A
Dehumidification1.4 L/h0.9 L/h1.9 pints/h per the submittal, converted
Advertised heating / cooling range−30 to 30 °C / −29 to 50 °C−30 to 24 °C / −10 to 46 °C

KINGHOME, POLARIS R32 technical sheet (12,000 BTU), undated. SHARP, submittal AE-X12CHU_AY-XP12CHU-EN1 (January 2026) and brochure MNSPLT-CHUCU 1.1.1; CHU dimensions published in millimetres, converted to inches.

Frequently asked questions

What people ask about these two wall units

What does the “minimum capacity” on a NEEP record mean?

It is the lowest output at which the unit was measured at that temperature, running continuously. When the room asks for less, the unit cannot slow down any further: it alternates between running and stopping.

The KINGHOME sheet lists 3,071 to 17,060 BTU/h: is that the same as the certified band?

Those two figures match the certified point at 8.3 °C, within one BTU/h at minimum (3,070 at NEEP). The colder it gets, the more the certified band changes: 2,000 to 7,300 BTU/h at −30 °C.

Why is the POLARIS rated value higher at −8.3 °C than at 8.3 °C?

At each temperature, NEEP publishes the rated capacity declared for the test. For the POLARIS, it is 12,000 BTU/h at 8.3 °C and 15,000 at −8.3 °C; for the CHU, 16,000 and 18,900. The maximum, for its part, drops with the temperature for both.

Which one goes lowest in extreme cold?

At −30 °C, NEEP certifies the CHU at 1,350 BTU/h minimum and the POLARIS at 2,000. At maximum, 9,700 and 7,300 BTU/h. At −15 °C, the minimums are 3,850 and 2,600 BTU/h: the order is reversed.

How far apart can the indoor and outdoor units be?

Up to 131 ft for the POLARIS and 66 ft for the CHU, according to their manufacturers, with 25 ft precharged in both cases. The gas line differs: 1/2 in for the POLARIS, 3/8 in for the CHU.

Does a heat pump use less at low speed?

In general, its efficiency is higher: at 8.3 °C, NEEP certifies a COP of 5.62 at minimum against 3.29 at maximum for the POLARIS, and 5.68 against 3.17 for the CHU. It is not always true in extreme cold: at −30 °C, the CHU is certified at 1.07 at minimum and 1.80 at maximum.

Are they eligible for grants?

Eligibility depends on the official list in effect on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.

Certified data

All AHRI and NEEP values

Certified valuePOLARIS R32CHU R32
Cooling
35 °C: min. / rated / max.BTU/h2,700 / 12,000 / 16,0003,500 / 12,000 / 14,000
SEER225.525.0
EER214.516.0
Heating, same conditions
HSPF2 Region IV / V10.0 / 8.011.0 / 9.0
8.3 °C: min. / rated / max.BTU/h3,070 / 12,000 / 17,0603,100 / 16,000 / 22,850
8.3 °C: COP min. / rated / max.5.62 / 4.19 / 3.295.68 / 4.26 / 3.17
−8.3 °C: min. / rated / max.BTU/h2,700 / 15,000 / 15,0005,000 / 18,900 / 18,900
−8.3 °C: COP min. / rated / max.3.04 / 2.14 / 2.002.93 / 2.22 / 2.22
−15 °C: min. / rated / max.BTU/h2,600 / 13,700 / 13,7003,850 / 16,000 / 16,000
−15 °C: COP min. / rated / max.3.17 / 1.80 / 1.802.35 / 2.10 / 2.10
Coldest point — not highlighted
Test temperature−30 °C (−22 °F)−30 °C (−22 °F)
Capacity min. / max.2,000 / 7,300 BTU/h1,350 / 9,700 BTU/h
COP at maximum capacity1.511.80
Certifications and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
AHRI certificate · NEEP record218451122 · 426104217512736 · 507383
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-32 · GWP 675 · A2L

higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted: the order changes depending on the point.

Both are on the AirGreen website.

To choose for your home, talk to our team: bring the size of the room, the width of the planned wall and the distance to the outdoor location.

Sources and documents