SAMSUNG WindFree MaxHeat and SHARP CHU R32, 12,000 BTU

Home / Comparisons / 12,000 BTU wall heat pumps

Comparison · Wall heat pump · 12,000 BTU

SAMSUNG WindFree MaxHeat and SHARP CHU R32: two ways of blowing air

Two 12,000 BTU R-32 wall units, both ENERGY STAR cold-climate certified and certified by NEEP down to −30 °C. What sets them apart first shows in the room: the way each one pushes the air, and the amount of air each manufacturer publishes. This page puts those documents side by side, then the certified points.

Max. heating airflow : 463 CFM and 636 CFMAt −30 °C (NEEP) : 6,800 and 9,700 BTU/hSEER2 24 and 25HSPF2 Region V 8.5 and 9
WindFree MaxHeat SHARP CHU

Drawing, in heating. Unit widths to scale: 889 mm and 1,052 mm. Each mode is detailed further down.

SAMSUNG WindFree MaxHeat R32 12,000 BTU (AirGreen image)
SAMSUNG

WindFree MaxHeat R32 12,000 BTU

AR12DXDABWKN / AR12DXDACWKX · AHRI 215399291

View the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.

Two ways of blowing

Where the air goes, and how much each manufacturer publishes

SAMSUNG relies on a WindFree mode that closes the louver in cooling and lets the air pass through micro-holes. SHARP describes a four-way automatic louver and a Coanda effect that sends warm air down and cool air up. Pick the season: the drawings and the airflows follow.

Season
WindFree MaxHeat SAMSUNG

Airflows: SAMSUNG Technical Data Book “RAC for North America R32”, version 1.2, AR12DXDABWKNCV sheet; four speeds, T / H / M / L. WindFree: SAMSUNG submittal 10072024A and the series page on samsunghvac.com.

CHU R32 SHARP

Airflows and features: SHARP “CHU/CU Series” brochure, MNSPLT-CHUCU 1.1.1 (January 2026); five values per mode, with no speed names.

Drawings, not measurements in a room: the length and speed of the arrows follow the highest airflow published for the season chosen, on the same scale for both. Neither manufacturer publishes the throw of the air jet for these models.

Why the airflows differ so much. At the top, the CHU publishes 636 CFM in heating, against 463 for the WindFree MaxHeat. Its lowest speed is also slower: 212 CFM against 286. The CHU indoor unit is wider, 1,052 mm against 889 mm. A higher airflow says nothing, on its own, about comfort or noise in your room: it says how much air the fan can move.
Extreme cold

Below −15 °C: every published number, at its exact temperature

Both are certified at the same temperatures, −15 °C and −30 °C: 9,000 and 16,000 BTU/h maximum at −15 °C, 6,800 and 9,700 BTU/h at −30 °C. In between, each manufacturer publishes its own points, with its own method.

Two manufacturer tables, two methods. In its Technical Data Book, SAMSUNG gives an “average value” for each condition: 14,400 BTU/h at −15 °C, while the certificate gives 9,000 BTU/h maximum. The page follows the certificate in every comparison. SHARP publishes, in its submittal, the maximum capacity at −20, −25, −27.2 and −30 °C; its two ends, 16,000 and 9,700 BTU/h, match the certificate. SAMSUNG lists heating down to −30 °C; SHARP states that heating stops at −30 °C.
Documented features

What each manufacturer writes, group by group

SAMSUNG: submittal 10072024A, Technical Data Book version 1.2 and the series page. SHARP: brochure MNSPLT-CHUCU 1.1.1 and submittal AE-X12CHU_AY-XP12CHU-EN1.

Air distribution and louver

WindFree MaxHeat : WindFree mode: louver closed in cooling, air spread through micro-holes in the front panel.

CHU : four-way automatic louver, Coanda effect, Spot Air and Multi Space.

Fan and airflows

WindFree MaxHeat : 4 speeds; 286 to 463 CFM in heating, 251 to 427 in cooling.

CHU : 5 values; 212 to 636 CFM in heating, 212 to 597 in cooling.

Modes

WindFree MaxHeat : AI Auto, AI Energy, Eco, Quiet, Good'sleep.

CHU : Full Power, Eco, 10 °C function (frost protection), OD Silent for the outdoor unit.

Controls and Wi-Fi

WindFree MaxHeat : built-in Wi-Fi, SmartThings app; remote rechargeable by solar cell or USB-C.

CHU : built-in Wi-Fi adapter per the submittal; wireless remote.

Occupancy and economy

WindFree MaxHeat : AI Energy and Eco modes; occupancy sensor not published in the documents read.

CHU : motion sensor that reduces heating or cooling when the room is empty, per the brochure; Eco mode.

Maintenance and drying

WindFree MaxHeat : Auto Clean.

CHU : After Care: dries the inside of the unit after it stops.

Extreme cold and outdoor unit

WindFree MaxHeat : base pan heater as standard; control of an external heat source with the MIM-B14U accessory.

CHU : Hot Gas Pipe: uses heat from heating to keep the outdoor unit from freezing.

Restart and timer

WindFree MaxHeat : not published in the documents read.

CHU : auto-restart; 24 h timer and off after 1, 2, 3 or 5 h.

Compressor

WindFree MaxHeat : twin rotary, BLDC.

CHU : single rotary.

Sound

Two published levels on one side, five on the other

SAMSUNG publishes two levels for the indoor unit, measured in an anechoic room. SHARP publishes five per season, without describing its test conditions.

dB(A)

How to read these numbers. dB(A) measures a noise level the way the ear perceives it: the lower the number, the quieter the unit. Each dot is a published fan speed, from slowest to fastest.

Why this is not a ranking. The methods are not the same, and neither are the airflows: at its highest speed, the CHU moves 636 CFM in heating, the WindFree MaxHeat 463. Both units read 22 dB(A) at their lowest, but not at the same speed or by the same method.

Indoor unit, in heating

Every published speed

Outdoor unit, outside

Published values

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Installation

On the wall, outside and in between

Is your wall wide enough?

110 cm
Indoor unit AR12DXDABWKN

Indoor unit AY-XP12CHU

0 cm160 cm, width of the strip

Photos scaled to the published width: 889 mm (35 in) for the WindFree MaxHeat, 1,052 mm (41 7/16 in) for the CHU. The yellow band flags a wall narrower than the unit. Clearances around the indoor unit are not counted: SHARP publishes none online for this model, and the installation manual settles it during the visit.

InstallationWindFree MaxHeatCHU R32
Maximum piping length66 ft66 ftMinimum 10 ft per the submittal
Precharged length24.6 ft25 ftBeyond that: 0.16 oz per ft
Maximum height difference49 ft33 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight31 1/8 × 21 9/16 × 11 1/4 in, 71 lb30.7 × 21.3 × 10.6 in, 66.1 lb780 × 540 × 269 mm, 30 kg
Indoor unit, weight23.1 lb35 × 11 3/4 × 8 7/16 in30.9 lb14 kg; 1,052 × 316 × 249 mm
Electrical protectionMCA 12 A; maximum breaker 20 AMCA 15 A; maximum fuse 20 A
Heated base panYes, as standardNEEP record 389387: 150 W, on from −8 °C in heatingNot published by the manufacturerSHARP describes its Hot Gas Pipe function instead, which uses heat from the circuit
DehumidificationNot published by the manufacturer0.9 L/h1.9 pints/h per the submittal, converted
Advertised heating / cooling range−30 to 24 °C / −18 to 46 °C−30 to 24 °C / −10 to 46 °C

SAMSUNG, submittal 10072024A (AR12DXDABWKNCV / AR12DXDACWKXCV). SHARP, submittal AE-X12CHU_AY-XP12CHU-EN1 (January 2026) and brochure MNSPLT-CHUCU 1.1.1; CHU dimensions published in millimetres, converted to inches.

Frequently asked questions

What people ask about these two wall units

What is WindFree mode?

According to SAMSUNG, in cooling, WindFree mode closes the louver and spreads the air through micro-holes in the front panel, to avoid a direct cold draft. SAMSUNG publishes neither the number of holes nor a measurement of the air in the room for this model. In heating, the air leaves through the louver.

What does “Coanda effect” mean at SHARP?

SHARP describes the Coanda effect as a way to direct warm air downward and cool air upward, so it does not blow in your face. The four-way automatic louver and the Spot Air function, which aims the air at a chosen spot, complete the list.

SAMSUNG publishes 14,400 BTU/h at −15 °C: why does the page put 9,000 forward?

SAMSUNG’s Technical Data Book states that its table gives an average value for each condition. The AHRI certificate, published by NEEP, gives 9,000 BTU/h maximum at −15 °C. When two sources differ, the page follows the certificate and shows the other value with its source.

Why does the CHU show a rated 16,000 BTU/h at 8.3 °C?

The “12,000” figure is the rated cooling capacity, the same for both. In heating at 8.3 °C, the CHU certificate gives 16,000 BTU/h rated and 22,850 maximum; the WindFree MaxHeat’s gives 12,000 and 15,500.

Which one takes more wall space?

The CHU: 1,052 mm wide, 316 mm high and 249 mm deep, for 14 kg. The WindFree MaxHeat measures 35 × 11 3/4 × 8 7/16 in (about 889 × 298 × 214 mm), for 23.1 lb.

And below −30 °C?

Both published heating ranges stop at −30 °C, and SHARP states that heating stops at that temperature. At −30 °C, NEEP certifies 6,800 BTU/h maximum for the WindFree MaxHeat and 9,700 BTU/h for the CHU.

Are they eligible for grants?

Eligibility depends on the official list in effect on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.

Certified data

All AHRI and NEEP values

Certified valueWindFree MaxHeatCHU R32
Cooling
35 °C: min. / rated / max.BTU/h3,000 / 12,000 / 16,0003,500 / 12,000 / 14,000
SEER224.025.0
EER214.116.0
Heating, same conditions
HSPF2 Region IV / V10.5 / 8.511.0 / 9.0
8.3 °C: min. / rated / max.BTU/h2,600 / 12,000 / 15,5003,100 / 16,000 / 22,850
8.3 °C: COP min. / rated / max.4.76 / 4.34 / 3.365.68 / 4.26 / 3.17
−8.3 °C: min. / rated / max.BTU/h1,600 / 10,600 / 10,6005,000 / 18,900 / 18,900
−8.3 °C: COP min. / rated / max.3.61 / 2.82 / 2.272.93 / 2.22 / 2.22
−15 °C: min. / rated / max.BTU/h2,400 / 9,000 / 9,0003,850 / 16,000 / 16,000
−15 °C: COP min. / rated / max.2.93 / 2.09 / 2.092.35 / 2.10 / 2.10
Coldest point — not highlighted
Test temperature−30 °C (−22 °F)−30 °C (−22 °F)
Capacity min. / max.1,200 / 6,800 BTU/h1,350 / 9,700 BTU/h
COP at maximum capacity1.731.80
Certifications and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
AHRI certificate · NEEP record215399291 · 389387217512736 · 507383
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-32 · GWP 675 · A2L

higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted: the order changes depending on the point.

Both are on the AirGreen website.

To choose for your home, talk to our team: bring the width of the planned wall, the distance to the outdoor location and how the room is used.

Sources and documents

Where each number comes from