Home / Comparisons / 12,000 BTU wall-mounted heat pumps
SAMSUNG WindFree Standard and LG DUALCOOL R32: the essentials, line by line
Two 12,000 BTU R-32 wall-mounted heat pumps, one from SAMSUNG, the other from LG. This page lines up what the AHRI certificates published by NEEP and the two manufacturers' documents say, one line at a time, with no score and no total.
SAMSUNGWindFree Standard R32 · 12,000 BTU
AR12DXFAMWKN / AR12DXFAMWKX · AHRI 215399297
See the product pageSAMSUNG first, LG second. AHRI certificates published by NEEP; capacities in BTU/h.
LGDUALCOOL R32 · 12,000 BTU
KNUAB121A / KUSAB121A · AHRI 215413007
Same outdoor unit (KUSAB121A) and same AHRI and NEEP certified values as the LG ARTCOOL MIRROR R32 (KNUAK121A, AHRI certificate 215413008).
See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal's design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards alike: a simplification that does not account for the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the value from the AHRI certificate published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat expected when the heat pump can no longer keep up. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, its insulation, the settings and how it is used; this amount is not a promise.
Twenty lines, two columns, no score
Each line says what a document publishes: the AHRI certificate as carried by NEEP, or a manufacturer's document. When nothing is published, the line says that too. The table builds itself as you watch; the buttons filter the lines by source.
The bars compare two values of the same measurement, under the same conditions, on the same scale. The “coldest certified point” and “indoor sound” lines have no bar: the temperatures or the methods differ. No line weighs more than another, and the page adds nothing up.
Below −15 °C: two data sheets that stop near −20 °C
NEEP certifies the WindFree Standard at −15 and −20.6 °C, and the DUALCOOL at −15 and −20 °C. SAMSUNG's Technical Data Book adds average values at −15, −17.8, −20 and −20.6 °C. Both manufacturers state a heating range that stops near −20 °C and publish no colder capacity. Between two published values, we show the range; nothing is calculated.
At −15 °C, both units have a maximum certified by NEEP: this is the row that compares directly. At −20 °C, the SAMSUNG value is an average from its Technical Data Book and the LG value a certified maximum: two different methods, with no direct comparison. The certified maximum of the WindFree Standard is higher at −20.6 °C (10,000 BTU/h) than at −15 °C (8,000 BTU/h): we show both values as NEEP publishes them. Below −21 °C, we repeat the last published point for each.
What each manufacturer writes, feature by feature
Only the features named in the documents consulted are listed. LG's DUALCOOL brochure is short; when it says nothing about a feature, we say so: that does not mean the feature does not exist.
Both stated ranges stop near −20 °C; these are operating ranges, not capacities.
Manufacturer's description; this page does not measure comfort.
A brochure's silence does not prove a feature is absent.
For LG, the information comes from the model's NEEP record, filled in by the manufacturer.
Both manufacturers describe a variable-speed twin rotary compressor.
SAMSUNG describes it in its submittal.
SAMSUNG names the feature, LG publishes a rate.
Names given by SAMSUNG in its submittal.
Useful for a room that needs cooling even in winter; these are stated ranges.
| Documented feature | WindFree Standard R32 | DUALCOOL R32 |
|---|---|---|
| Base pan heater | Not published by the manufacturer neither the submittal nor the NEEP record lists one | Yes built in; 90 W, on at 0 °C and below in heating mode per the NEEP record |
| Wi-Fi app | Yes SmartThings, built-in Wi-Fi adapter | Yes ThinQ, per NEEP record 389313 |
| Filter and automatic cleaning | Yes Auto Clean, Freeze Wash, washable filter | Not published by the manufacturer brochure 04_25 |
| Compressor | Twin BLDC rotary submittal 10072024A | Twin rotary brochure 04_25 |
| Remote control | Yes wireless, solar cell or USB-C | Not published by the manufacturer brochure 04_25 |
| Backup heat in extreme cold | Yes emergency heat with the optional MIM-B14U interface | Not published by the manufacturer brochure 04_25 |
| Cooling in cold weather | Down to −10 °C stated range | Down to −10 °C −18 °C with the optional kit |
Indoor unit sound, fan speed by fan speed
Published indoor sound pressure
Each point is one fan speed published by the manufacturer.
How to read these figures. The lower the decibel figure, the quieter the unit. Each point is one published fan speed. A rise of 10 dB(A) is heard as roughly twice as loud.
Why this is not a ranking. SAMSUNG publishes only the lowest and the highest speed; LG publishes four speeds in cooling. Neither document consulted states the measuring distance or the test room.
Measured by each manufacturer with its own method: different methods — not comparable point by point.
Five eighths of an inch apart on the wall
Both indoor units, widths at the same scale




Width of the unit only, per the manufacturer (821 and 837 mm: conversions). The clearances around the indoor unit are given in each manufacturer's installation manual.
| Installation, according to the manufacturers' documents | WindFree Standard R32 | DUALCOOL R32 |
|---|---|---|
| Maximum piping length | 66 ft | 82 ft minimum 9.8 ft |
| Precharged length | 24.6 ft | 41 ft 0.16 oz per ft beyond |
| Maximum height difference | 49 ft | 49.2 ft |
| Liquid – gas line diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 31 1/8 × 21 9/16 × 11 1/4 in, 69.2 lb | 30 5/16 × 21 15/32 × 11 11/32 in, 68.8 lb |
| Indoor unit, weight | 32 5/16 × 11 3/4 × 8 7/16 in, 20.3 lb | 32 15/16 × 12 1/8 × 7 7/16 in, 19.73 lb |
| Electrical protection | MCA 12 A · max. breaker 20 A | MCA 12 A · MOCP 15 A |
| Dehumidification | Not published by the manufacturer Dry mode named; rate not stated | 1.3 L/h 2.75 US pt/h according to LG |
| Stated heating / cooling range | −20.6 to 24 °C / −10 to 46 °C | −20 to 18 °C / −10 to 48 °C heating in wet bulb |
Questions about this pair
Why do some lines say “Not published by the manufacturer”?
Because the documents consulted do not give the information. LG's DUALCOOL brochure is short and describes neither the remote nor the modes; the SAMSUNG submittal gives no dehumidification rate. A document's silence does not mean the feature does not exist.
Which one delivers more heat at −15 °C?
At −15 °C, same temperature and same source: 10,000 BTU/h maximum for the DUALCOOL R32 (COP of 1.99) and 8,000 BTU/h for the WindFree Standard (COP of 1.76), according to NEEP.
Why does the WindFree Standard show 10,000 BTU/h at −20.6 °C and 8,000 BTU/h at −15 °C?
These are the two values NEEP publishes with AHRI certificate 215399297: 8,000 BTU/h maximum at 5 °F and 10,000 BTU/h at the coldest point, −5 °F. We show them as they are. SAMSUNG's Technical Data Book, for its part, gives average values measured differently: 13,100 BTU/h at −15 °C and 9,200 BTU/h at −20.6 °C.
Are both ENERGY STAR certified for cold climates?
According to NEEP, on November 9, 2026: the DUALCOOL R32 is ENERGY STAR and ENERGY STAR Cold Climate certified; the WindFree Standard is ENERGY STAR certified, without the cold-climate designation.
Which one costs less to run?
With our method, the WindFree Standard needs slightly less electricity: Region V HSPF2 of 8.5 versus 8.0, SEER2 of 24.0 versus 22.5. The “Cost by season” module shows the exact difference for your hours of use.
Do the DUALCOOL and the ARTCOOL MIRROR have the same data sheet?
They have the same AHRI and NEEP certified values and the same KUSAB121A outdoor unit, under two certificates: 215413007 for the DUALCOOL R32 and 215413008 for the ARTCOOL MIRROR R32. The indoor unit and its finish differ.
What about the warranty?
Each manufacturer publishes its own terms. The warranty documents come with the quote.
AHRI certificate values, as published by NEEP
| Certified value | WindFree Standard R32 | DUALCOOL R32 |
|---|---|---|
| Seasonal efficiencies | ||
| SEER2 | 24.0 | 22.5 |
| EER2 | 13.25 | 12.8 |
| HSPF2 Region IV | 9.0 | 10.5 |
| HSPF2 Region V | 8.5 | 8.0 |
| Rated capacity at 35 °C (cooling) | 12,000 BTU/h | 12,000 BTU/h |
| Heating, min. / rated / max. capacity | ||
| Min. / rated / max. capacity at 8.3 °C | 2,200 / 12,000 / 15,000 | 1,023 / 13,600 / 19,040 |
| Min. / rated / max. capacity at −8.3 °C | 1,600 / 10,900 / 10,900 | 1,877 / 8,500 / 12,400 |
| Min. / rated / max. capacity at −15 °C | 2,400 / 8,000 / 8,000 | 1,706 / 10,000 / 10,000 |
| Min. / rated / max. COP at 8.3 °C | 4.61 / 3.82 / 2.84 | 1.50 / 3.83 / 2.83 |
| Min. / rated / max. COP at −8.3 °C | 3.61 / 3.04 / 2.00 | 1.49 / 2.86 / 2.19 |
| Min. / rated / max. COP at −15 °C | 2.93 / 1.76 / 1.76 | 1.43 / 1.99 / 1.99 |
| Coldest point (different temperatures) | ||
| Test temperature | −20.6 °C (−5 °F) | −20 °C (−4 °F) |
| Max. capacity at the coldest point | 10,000 BTU/h | 8,010 BTU/h |
| Max. COP at the coldest point | 1.81 | 1.79 |
| Certification | ||
| Refrigerant | R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34) | R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34) |
| ENERGY STAR | Yes NEEP, Nov. 9, 2026 | Yes NEEP, Nov. 9, 2026 |
| ENERGY STAR cold climate | No NEEP, Nov. 9, 2026 | Yes NEEP, Nov. 9, 2026 |
| AHRI certificate · NEEP record | 215399297 · 389381 | 215413007 · 389313 |
“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation.
Both are on the AirGreen site.
For an estimate visit or a quote on either of these units.
Documents consulted
Data verified on November 9, 2026. Certified values: AHRI certificates published by NEEP. Declared values (sound, dimensions, piping, features): the manufacturers' documents cited above. When two sources differ, the AHRI certificate prevails.
SAMSUNG, WindFree, LG, DUALCOOL and ARTCOOL are trademarks of their respective owners. Logos are used only to identify the products. AirGreen is a retailer of these brands; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.