SAMSUNG WindFree Standard and LG DUALCOOL R32, 12,000 BTU

Home / Comparisons / 12,000 BTU wall-mounted heat pumps

Comparison · wall-mounted heat pump · 12,000 BTU

SAMSUNG WindFree Standard and LG DUALCOOL R32: the essentials, line by line

Two 12,000 BTU R-32 wall-mounted heat pumps, one from SAMSUNG, the other from LG. This page lines up what the AHRI certificates published by NEEP and the two manufacturers' documents say, one line at a time, with no score and no total.

SAMSUNG WindFree Standard R32 12,000 BTU (AirGreen image) SAMSUNG

WindFree Standard R32 · 12,000 BTU

AR12DXFAMWKN / AR12DXFAMWKX · AHRI 215399297

See the product page
SEER224.0·22.5
HSPF2 Region V8.5·8.0
Max. at −15 °C, certified8,000·10,000
ENERGY STAR cold climateNo·Yes

SAMSUNG first, LG second. AHRI certificates published by NEEP; capacities in BTU/h.

LG DUALCOOL R32 12,000 BTU (AirGreen image) LG

DUALCOOL R32 · 12,000 BTU

KNUAB121A / KUSAB121A · AHRI 215413007

Same outdoor unit (KUSAB121A) and same AHRI and NEEP certified values as the LG ARTCOOL MIRROR R32 (KNUAK121A, AHRI certificate 215413008).

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal's design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards alike: a simplification that does not account for the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the value from the AHRI certificate published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat expected when the heat pump can no longer keep up. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, its insulation, the settings and how it is used; this amount is not a promise.

The essentials

Twenty lines, two columns, no score

Each line says what a document publishes: the AHRI certificate as carried by NEEP, or a manufacturer's document. When nothing is published, the line says that too. The table builds itself as you watch; the buttons filter the lines by source.

LineWindFree Standard R32DUALCOOL R32
NEEP certified value from the AHRI certificate Per the manufacturer manufacturer's document, outside the certificate Not published by the manufacturer nothing in the documents consulted: that does not mean the feature does not exist

The bars compare two values of the same measurement, under the same conditions, on the same scale. The “coldest certified point” and “indoor sound” lines have no bar: the temperatures or the methods differ. No line weighs more than another, and the page adds nothing up.

Extreme cold

Below −15 °C: two data sheets that stop near −20 °C

NEEP certifies the WindFree Standard at −15 and −20.6 °C, and the DUALCOOL at −15 and −20 °C. SAMSUNG's Technical Data Book adds average values at −15, −17.8, −20 and −20.6 °C. Both manufacturers state a heating range that stops near −20 °C and publish no colder capacity. Between two published values, we show the range; nothing is calculated.

At −15 °C, both units have a maximum certified by NEEP: this is the row that compares directly. At −20 °C, the SAMSUNG value is an average from its Technical Data Book and the LG value a certified maximum: two different methods, with no direct comparison. The certified maximum of the WindFree Standard is higher at −20.6 °C (10,000 BTU/h) than at −15 °C (8,000 BTU/h): we show both values as NEEP publishes them. Below −21 °C, we repeat the last published point for each.

Features

What each manufacturer writes, feature by feature

Only the features named in the documents consulted are listed. LG's DUALCOOL brochure is short; when it says nothing about a feature, we say so: that does not mean the feature does not exist.

Heating in extreme cold
SAMSUNG: stated heating range −20.6 to 24 °C; emergency heat and control of an external heat source with the optional MIM-B14U interface.LG: stated heating range −20 to 18 °C (wet bulb); heater built into the drain pan.

Both stated ranges stop near −20 °C; these are operating ranges, not capacities.

Air distribution and louver
SAMSUNG: WindFree mode, the louver closes and the air passes through micro-perforations, at under 0.15 m/s according to SAMSUNG; automatic vertical and horizontal louvers.LG: not stated in the brochure consulted.

Manufacturer's description; this page does not measure comfort.

Maintenance and cleaning
SAMSUNG: Auto Clean, Freeze Wash, washable main filter with cleaning reminder.LG: not stated in the brochure consulted.

A brochure's silence does not prove a feature is absent.

Wi-Fi app
SAMSUNG: built-in Wi-Fi adapter, SmartThings app.LG: ThinQ Wi-Fi per the NEEP record; not stated in the brochure.

For LG, the information comes from the model's NEEP record, filled in by the manufacturer.

Compressor
SAMSUNG: twin BLDC rotary, inverter.LG: twin rotary, inverter.

Both manufacturers describe a variable-speed twin rotary compressor.

Remote control
SAMSUNG: wireless, rechargeable by solar cell or USB-C, included.LG: not stated in the brochure consulted.

SAMSUNG describes it in its submittal.

Dehumidification
SAMSUNG: Dry mode and “Comfort Humidity Control” with a humidity sensor; rate not published.LG: 2.75 US pints per hour, or 1.3 L/h.

SAMSUNG names the feature, LG publishes a rate.

Operating modes
SAMSUNG: AI Auto, AI Energy, MAX, Good'sleep, Quiet, Eco.LG: not described in the brochure consulted.

Names given by SAMSUNG in its submittal.

Cooling in cold weather
SAMSUNG: stated cooling down to −10 °C.LG: down to −10 °C; down to −18 °C with the optional kit.

Useful for a room that needs cooling even in winter; these are stated ranges.

Documented featureWindFree Standard R32DUALCOOL R32
Base pan heaterNot published by the manufacturer neither the submittal nor the NEEP record lists oneYes built in; 90 W, on at 0 °C and below in heating mode per the NEEP record
Wi-Fi appYes SmartThings, built-in Wi-Fi adapterYes ThinQ, per NEEP record 389313
Filter and automatic cleaningYes Auto Clean, Freeze Wash, washable filterNot published by the manufacturer brochure 04_25
CompressorTwin BLDC rotary submittal 10072024ATwin rotary brochure 04_25
Remote controlYes wireless, solar cell or USB-CNot published by the manufacturer brochure 04_25
Backup heat in extreme coldYes emergency heat with the optional MIM-B14U interfaceNot published by the manufacturer brochure 04_25
Cooling in cold weatherDown to −10 °C stated rangeDown to −10 °C −18 °C with the optional kit
Sound

Indoor unit sound, fan speed by fan speed

Published indoor sound pressure

Each point is one fan speed published by the manufacturer.

dB

How to read these figures. The lower the decibel figure, the quieter the unit. Each point is one published fan speed. A rise of 10 dB(A) is heard as roughly twice as loud.

Why this is not a ranking. SAMSUNG publishes only the lowest and the highest speed; LG publishes four speeds in cooling. Neither document consulted states the measuring distance or the test room.

Measured by each manufacturer with its own method: different methods — not comparable point by point.

Installation

Five eighths of an inch apart on the wall

Both indoor units, widths at the same scale

WindFree Standard R3232 5/16 in · 821 mm
SAMSUNG WindFree Standard R32 indoor unit
32 5/16 in · 821 mm
DUALCOOL R3232 15/16 in · 837 mm
LG DUALCOOL R32 indoor unit
32 15/16 in · 837 mm
40 in
WindFree Standard R32

DUALCOOL R32

Width of the unit only, per the manufacturer (821 and 837 mm: conversions). The clearances around the indoor unit are given in each manufacturer's installation manual.

Installation, according to the manufacturers' documentsWindFree Standard R32DUALCOOL R32
Maximum piping length66 ft82 ft minimum 9.8 ft
Precharged length24.6 ft41 ft 0.16 oz per ft beyond
Maximum height difference49 ft49.2 ft
Liquid – gas line diameters1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight31 1/8 × 21 9/16 × 11 1/4 in, 69.2 lb30 5/16 × 21 15/32 × 11 11/32 in, 68.8 lb
Indoor unit, weight32 5/16 × 11 3/4 × 8 7/16 in, 20.3 lb32 15/16 × 12 1/8 × 7 7/16 in, 19.73 lb
Electrical protectionMCA 12 A · max. breaker 20 AMCA 12 A · MOCP 15 A
DehumidificationNot published by the manufacturer Dry mode named; rate not stated1.3 L/h 2.75 US pt/h according to LG
Stated heating / cooling range−20.6 to 24 °C / −10 to 46 °C−20 to 18 °C / −10 to 48 °C heating in wet bulb
Questions

Questions about this pair

Why do some lines say “Not published by the manufacturer”?

Because the documents consulted do not give the information. LG's DUALCOOL brochure is short and describes neither the remote nor the modes; the SAMSUNG submittal gives no dehumidification rate. A document's silence does not mean the feature does not exist.

Which one delivers more heat at −15 °C?

At −15 °C, same temperature and same source: 10,000 BTU/h maximum for the DUALCOOL R32 (COP of 1.99) and 8,000 BTU/h for the WindFree Standard (COP of 1.76), according to NEEP.

Why does the WindFree Standard show 10,000 BTU/h at −20.6 °C and 8,000 BTU/h at −15 °C?

These are the two values NEEP publishes with AHRI certificate 215399297: 8,000 BTU/h maximum at 5 °F and 10,000 BTU/h at the coldest point, −5 °F. We show them as they are. SAMSUNG's Technical Data Book, for its part, gives average values measured differently: 13,100 BTU/h at −15 °C and 9,200 BTU/h at −20.6 °C.

Are both ENERGY STAR certified for cold climates?

According to NEEP, on November 9, 2026: the DUALCOOL R32 is ENERGY STAR and ENERGY STAR Cold Climate certified; the WindFree Standard is ENERGY STAR certified, without the cold-climate designation.

Which one costs less to run?

With our method, the WindFree Standard needs slightly less electricity: Region V HSPF2 of 8.5 versus 8.0, SEER2 of 24.0 versus 22.5. The “Cost by season” module shows the exact difference for your hours of use.

Do the DUALCOOL and the ARTCOOL MIRROR have the same data sheet?

They have the same AHRI and NEEP certified values and the same KUSAB121A outdoor unit, under two certificates: 215413007 for the DUALCOOL R32 and 215413008 for the ARTCOOL MIRROR R32. The indoor unit and its finish differ.

What about the warranty?

Each manufacturer publishes its own terms. The warranty documents come with the quote.

Certified data

AHRI certificate values, as published by NEEP

Certified valueWindFree Standard R32DUALCOOL R32
Seasonal efficiencies
SEER224.022.5
EER213.2512.8
HSPF2 Region IV9.010.5
HSPF2 Region V8.58.0
Rated capacity at 35 °C (cooling)12,000 BTU/h12,000 BTU/h
Heating, min. / rated / max. capacity
Min. / rated / max. capacity at 8.3 °C2,200 / 12,000 / 15,0001,023 / 13,600 / 19,040
Min. / rated / max. capacity at −8.3 °C1,600 / 10,900 / 10,9001,877 / 8,500 / 12,400
Min. / rated / max. capacity at −15 °C2,400 / 8,000 / 8,0001,706 / 10,000 / 10,000
Min. / rated / max. COP at 8.3 °C4.61 / 3.82 / 2.841.50 / 3.83 / 2.83
Min. / rated / max. COP at −8.3 °C3.61 / 3.04 / 2.001.49 / 2.86 / 2.19
Min. / rated / max. COP at −15 °C2.93 / 1.76 / 1.761.43 / 1.99 / 1.99
Coldest point (different temperatures)
Test temperature−20.6 °C (−5 °F)−20 °C (−4 °F)
Max. capacity at the coldest point10,000 BTU/h8,010 BTU/h
Max. COP at the coldest point1.811.79
Certification
RefrigerantR-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)
ENERGY STARYes NEEP, Nov. 9, 2026Yes NEEP, Nov. 9, 2026
ENERGY STAR cold climateNo NEEP, Nov. 9, 2026Yes NEEP, Nov. 9, 2026
AHRI certificate · NEEP record215399297 · 389381215413007 · 389313

“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation.

Both are on the AirGreen site.

For an estimate visit or a quote on either of these units.

Sources

Documents consulted

NEEP, record 389381 (AHRI 215399297)SAMSUNG AR12DXFAMWKN / AR12DXFAMWKX · record updated Nov. 6, 2026 · accessed Nov. 9, 2026
NEEP, record 389313 (AHRI 215413007)LG KNUAB121A / KUSAB121A · record updated Nov. 6, 2026 · accessed Nov. 9, 2026
NEEP, record 389312 (AHRI 215413008)LG KNUAK121A / KUSAB121A (ARTCOOL MIRROR R32) · accessed Nov. 9, 2026
SAMSUNG, Submittal AR12DXFAMWKNCV / AR12DXFAMWKXCV, WindFree Standardversion 10072024A, file dated August 4, 2026 · accessed Nov. 9, 2026
SAMSUNG, Technical Data Book “2024 RAC for North America (R32, 60Hz, HP)”, v1.2heating table RNX12AMD + RXX12AMD, p. 35, 21.1 °C indoors, average values · accessed Nov. 9, 2026
LG, DUALCOOL, brochure (FR)PO_LG_R32_High_Efficiency_04_25_CA_FR (2025) · accessed Nov. 9, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, s. 2.5
NRCan, HOT2000 climate mapMontréal Intl: 4,167 degree-days, −23.1 °C