ZEPHYR CB25 and HAXXAIR V2D: the same certified values
Two brands, two AHRI certificates, two model numbers. When the two NEEP records are lined up, the figures are the same at every test temperature. This page shows what is shared, what is not, and where each piece of information comes from.
ZEPHYR
CB25 R-454B · 12,000 BTU
ind. ZE-12CB25I · out. ZE-12CB25O · AHRI 215414830 · NEEP 418302
See the product page
HAXXAIR
V2D R-454B · 12,000 BTU
ind. HAHZ-12V2D · out. HVHZ-12V2D · AHRI 216012011 · NEEP 203876
See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; since their certified efficiencies are identical, so are their amounts. Electric baseboards serve as the reference.
How this amount is calculated
- Heat needed in winter: 12,000 BTU/h (3.52 kW) × 24 h × 4,167 degree-days (base 18 °C) ÷ (18 − (−23.1 °C)), prorated to the heating hours chosen. Degree-days and design temperature: Natural Resources Canada, HOT2000 climate map, Montréal International station. At 24 h a day: 8,558 kWh of heat.
- Heat pump electricity: heat × 3.412 ÷ HSPF2 Region V from the AHRI certificate (9.0 for both). Region V accounts for the electric backup the standard provides for.
- Electric baseboards: 1 kWh of electricity per kWh of heat.
- Cooling: 12,000 BTU/h ÷ SEER2 (23 for both) × hours a day × 60 days ÷ 1,000, the method of Hydro-Québec's air-conditioning calculator.
- Price: Hydro-Québec Rate D in effect April 1, 2026, taxes (GST and QST) included; system access charge excluded.
Two simplifications: fewer heating hours reduce the heat pro rata, without counting the recovery after a setback; 24 h of cooling assume rated capacity all day, which is a maximum, since a variable-speed unit slows down. The result is an estimate, not a bill.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
The two NEEP records, lined up row by row
Each row comes from the NEEP record of each AHRI certificate, read November 10, 2026. The counter checks the values one by one, live.
Same certified figures, but not quite the same file
An AHRI certificate measures performance. It says nothing about the indoor unit's design, the remote, the documents that come with the unit or the warranty. What follows comes from the documents found for each brand.
Numbers and certificates
ZEPHYR ZE-12CB25I / ZE-12CB25O · AHRI 215414830 · NEEP series "HiULTRA" · ENERGY STAR 3624587, certified January 20, 2025.
HAXXAIR HAHZ-12V2D / HVHZ-12V2D · AHRI 216012011 · NEEP series "Hi UNI" · ENERGY STAR 3723080, certified February 17, 2025.
Manufacturer documents
ZEPHYR CB25 brochure (code BRO_2606): deep-cold capacities, sound, dimensions, piping, features.
HAXXAIR 2026 catalogue of the distributor RBL A/C, p. 10: "HAHZ-12V2D, 12,000 Btu/h, 23 SEER". No technical sheet for the V2D wall unit found on haxxair.com on November 10, 2026.
Indoor units


Real photos, same display width, not to scale: HAXXAIR does not publish the V2D's dimensions in the documents found. ZEPHYR: 33 7/16 × 11 9/16 × 8 1/16 in.
Remotes


Two branded remotes, from the product card photos. The ZEPHYR brochure names an LED wireless remote with "ifeel" mode.
Features described
ZEPHYR Heated outdoor base, automatic defrost, automatic 8 °C heating, sleep and quiet modes, self-cleaning, five fan speeds.
HAXXAIR The RBL catalogue describes, for HAXXAIR heat pumps in general, a heating element in the outdoor unit's condensate pan; no list specific to the V2D.
Warranty
Each manufacturer sets its own terms. This page does not compare them; the warranty documents come with the quote.
Below −15 °C, each one's published points
The certified points land on top of each other. The only extra points come from the ZEPHYR brochure, which also publishes −20 °C; HAXXAIR publishes none in the documents found.
The AHRI values, as NEEP publishes them
| Certified value | ZEPHYR CB25 | HAXXAIR V2D |
|---|---|---|
| Seasonal efficiency | ||
| SEER2 | 23 | 23 |
| EER2 | 12.25 | 12.25 |
| HSPF2 Region IV | 10 | 10 |
| HSPF2 Region V | 9 | 9 |
| Heating at 8.3 °C (47 °F) | ||
| Capacity min. / rated / max., BTU/h | 3,000 / 12,000 / 13,000 | 3,000 / 12,000 / 13,000 |
| COP min. / rated / max. | 4 / 3.91 / 3.17 | 4 / 3.91 / 3.17 |
| Heating at −8.3 °C (17 °F) | ||
| Capacity min. / rated / max., BTU/h | 2,550 / 10,800 / 12,000 | 2,550 / 10,800 / 12,000 |
| COP min. / rated / max. | 3.74 / 2.4 / 2.51 | 3.74 / 2.4 / 2.51 |
| Heating at −15 °C (5 °F) | ||
| Capacity min. / rated / max., BTU/h | 2,000 / 11,000 / 11,000 | 2,000 / 11,000 / 11,000 |
| COP min. / rated / max. | 1.47 / 2 / 2 | 1.47 / 2 / 2 |
| Coldest published point | ||
| Test temperature | −25 °C (−13 °F) | −25 °C (−13 °F) |
| Capacity min. / max., BTU/h | 1,000 / 6,100 | 1,000 / 6,100 |
| COP min. / max. | 0.81 / 1.38 | 0.81 / 1.38 |
| Cooling | ||
| Capacity min. / rated / max. at 35 °C, BTU/h | 3,000 / 12,000 / 13,000 | 3,000 / 12,000 / 13,000 |
| Certification and refrigerant | ||
| AHRI certificate · NEEP record | 215414830 · 418302 | 216012011 · 203876 |
| ENERGY STAR, cold climate | Yes; cold climate: yes | Yes; cold climate: yes |
| Refrigerant | R-454B · GWP 466 · class A2L | R-454B · GWP 466 · class A2L |
No value is marked "higher": they are all equal. Values: NEEP records 418302 and 203876, consulted November 10, 2026. GWP: IPCC Fourth Assessment Report (AR4); safety class: ASHRAE 34.
Questions about these two names
How can two brands have the same figures?
The AHRI directory lists each combination under the name of the brand that sells it. When two listings give the same values at every test temperature, they have the same AHRI and NEEP certified values. The model numbers and certificates stay separate; this page does not say who makes either one, since no document consulted states it.
Is there any difference at all in the NEEP records?
Only one, in presentation: at the −25 °C point, the HAXXAIR record also shows a rated COP of 2, with no rated capacity attached; the ZEPHYR record leaves that field empty. All capacities and all minimum and maximum COPs are identical.
Which one costs less to run?
With the same certified HSPF2 and SEER2, the AirGreen estimate gives exactly the same amount for both, winter and summer.
Down to what temperature do they heat?
The coldest point on both certificates is −25 °C, with a maximum of 6,100 BTU/h. The ZEPHYR brochure states a heating range down to −30 °C; no HAXXAIR document found publishes a range for the V2D.
How do you choose between the two?
The certified figures do not separate these two units. What remains: the look of the indoor unit, the remote, the documents provided and each manufacturer's warranty terms. AirGreen offers both.
Are they eligible for Hydro-Québec programs?
Both are ENERGY STAR cold-climate certified. LogisVert eligibility is checked against Hydro-Québec's official list, which can change; this page states no amount.
Both are on the AirGreen site.
A question about the CB25 or the V2D for your home? Talk it over with our team.
Documents consulted
Data verified November 10, 2026. Certified values: AHRI certificates published by NEEP. Declared values: the documents cited above. The cost is an estimate using the AirGreen method v1.1 described in the "Cost by season" section.
ZEPHYR, HAXXAIR, ENERGY STAR and AHRI are trademarks of their respective owners. Logos and images are used only to identify the products. AirGreen is a dealer of these products; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong to you? Write to us at sales@airgreen.ca.