ZEPHYR CB25 R-454B and SENVILLE AURA R454B, 12,000 BTU

Comparison · wall heat pump · 12,000 BTU

ZEPHYR CB25 R-454B and SENVILLE AURA R454B, number by number

Two 12,000 BTU wall heat pumps on R-454B, both ENERGY STAR cold-climate certified. Their AHRI certificates do not stop at the same temperature: the last published point is −25 °C for one and −30 °C for the other. This page shows what each one publishes, where, and from which source.

Refrigerant R-454B for both SEER2 23 · 25.4 HSPF2 Region V 9 · 8 Coldest certified point −25 °C · −30 °C
AirGreen product card of the ZEPHYR CB25 R-454B 12,000 BTU wall heat pump ZEPHYR

CB25 R-454B · 12,000 BTU

ind. ZE-12CB25I · out. ZE-12CB25O · AHRI 215414830

Also sold as HAXXAIR V2D R-454B 12,000: same NEEP-certified values, separate certificate (AHRI 216012011).

See the product page
AirGreen product card of the SENVILLE AURA R454B 12,000 BTU wall heat pump SENVILLE

AURA R454B · 12,000 BTU

ind. SENA-12HF-IGG · out. SENA-12HF-OG · AHRI 215735296

Also sold as MIDEA28, DIRECT AIR Heat Xtreme Pro R-454B and BOSCH MAX PERFORMANCE R-454B: same NEEP-certified values, separate certificates.

See the product page
11,000·11,500
max. BTU/h certified at −15 °C, same temperature for both
2·1.8
COP certified at −15 °C (maximum capacity)
1,000·2,000
min. BTU/h at the coldest point, at −25 °C and at −30 °C
13,000·16,000
max. BTU/h certified at 8.3 °C
Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference.

How this amount is calculated
  1. Heat needed in winter: 12,000 BTU/h (3.52 kW) × 24 h × 4,167 degree-days (base 18 °C) ÷ (18 − (−23.1 °C)), prorated to the heating hours chosen. Degree-days and design temperature: Natural Resources Canada, HOT2000 climate map, Montréal International station. At 24 h a day: 8,558 kWh of heat.
  2. Heat pump electricity: heat × 3.412 ÷ HSPF2 Region V from the AHRI certificate (9.0 for the CB25, 8.0 for the AURA). Region V accounts for the electric backup the standard provides for.
  3. Electric baseboards: 1 kWh of electricity per kWh of heat.
  4. Cooling: 12,000 BTU/h ÷ SEER2 (23 and 25.4) × hours a day × 60 days ÷ 1,000, the method of Hydro-Québec's air-conditioning calculator.
  5. Price: Hydro-Québec Rate D in effect April 1, 2026, taxes (GST and QST) included; system access charge excluded.

Two simplifications: fewer heating hours reduce the heat pro rata, without counting the recovery after a setback; 24 h of cooling assume rated capacity all day, which is a maximum, since a variable-speed unit slows down. The result is an estimate, not a bill.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Each one's last point

Where each certificate stops, and what it says there

NEEP publishes the AHRI values at 8.3, −8.3 and −15 °C, then a single colder point chosen by the manufacturer. For the CB25 that point is at −25 °C; for the AURA, at −30 °C. The two columns below each show their own point, at their own temperature.

Same temperature for both. At −15 °C, both certificates give a value measured under the same test conditions: this is where the direct comparison is made.

Different temperatures. 6,100 BTU/h at −25 °C and 5,900 BTU/h at −30 °C do not compare with each other: five degrees separate them, and neither certificate gives the other unit's value at that temperature. The "Deep cold" table further down shows, for each one, what is published at −20, −25 and −30 °C.

Output range

How far down each one can slow, and how far up it can go

A variable-speed heat pump spends most of its time between its minimum and maximum capacity. The certificates publish both ends at each test temperature. The lower the bottom end, the more the unit can slow down instead of stopping and restarting; the higher the top end, the more reserve it has.

ZEPHYR CB25SENVILLE AURAcertified rated capacity, where published

Deep cold

Below −15 °C, what each manufacturer publishes

Each point comes from a NEEP certificate or a manufacturer document, with its temperature. Between two published points, the page gives the range of the two values on either side of the temperature, without calculating anything in between.

At −15 °C, the ZEPHYR brochure (BRO_2606) gives 10,600 BTU/h and the AHRI certificate 11,000 BTU/h. The page shows both; the certificate prevails in any comparison. Below −25 °C, ZEPHYR states a heating range down to −30 °C without publishing a capacity figure. SENVILLE publishes a certified capacity at −15 °C and then at −30 °C, and nothing in between: at −20 and −25 °C, the page gives the range of those two values.

Features

What each manufacturer writes, line by line

The features come from the ZEPHYR CB25 brochure (BRO_2606) and the SENVILLE AURA SENA-12HF product page on senville.ca. A feature missing from a document is not necessarily missing from the unit: the document simply does not mention it.

Outdoor unit base pan heater

CB25 "Heated base chassis (outdoor)" and "Base heating".

AURA PTC heat belt and heated pan.

Automatic defrost

CB25 "Automatic defrost".

AURA Not mentioned on the page consulted.

Wi-Fi and app

CB25 Not mentioned in the brochure.

AURA Voice control and Alexa app with the included USB kit.

Remote with built-in temperature sensor

CB25 LED wireless remote, "ifeel" mode.

AURA "Follow Me" remote with built-in thermostat.

Indoor fan speeds

CB25 Five speeds, plus a Turbo function.

AURA Four published speeds: Turbo, high, medium, low.

Airflow direction (louvers)

CB25 Automatic swing, louver position memory, "4D MODE".

AURA Vertical swing.

Self-cleaning and filter

CB25 "Automatic cleaning".

AURA Self-cleaning mode; silver-ion filter.

Refrigerant leak detection

CB25 Not mentioned in the brochure.

AURA Refrigerant leak detection.

Sleep, quiet and 8 °C heat modes

CB25 Sleep mode, quiet mode, automatic 8 °C (46 °F) heating, 24 h timer.

AURA 8 °C (46 °F) heating in the SENVILLE series brochure; self-diagnosis.

Compressor and expansion device

CB25 GMCC rotary compressor, electronic expansion valve (EEV).

AURA Not specified on the page consulted.

Sound

The published decibels, speed by speed

dB

How to read these numbers. Each dot is a fan speed published by the manufacturer, in dB(A); the lower the number, the quieter the unit at that speed.

Why this is not a ranking. Neither the ZEPHYR brochure nor the SENVILLE page states the distance or the measuring method, and the speeds do not carry the same names. Each set of numbers is read on its own.

Measurements taken by each manufacturer with its own method: different method — not comparable.

Installation

What goes on the wall, what goes outside

The two indoor units are almost the same width, within four hundredths of an inch. The AURA is a little deeper; the CB25 has a taller outdoor unit. Real photos, set to the same width scale.

Indoor units, to scale

Is your wall wide enough?

36 po
048 in

Unit width only. The side and top clearances required by each manufacturer's installation manual come on top.

Outdoor units, to scale

InstallationZEPHYR CB25SENVILLE AURA
Pre-charged length25 ftBrochure BRO_260625 ftsenville.ca, SENA-12HF
Maximum piping length10 to 98 ftBrochure BRO_2606Not published by the manufactureron the product page consulted
Maximum height difference50 ftindoor unit higher, brochure BRO_2606Not published by the manufactureron the product page consulted
Liquid – gas diameters1/4 – 3/8 inBrochure BRO_2606Not published by the manufactureron the product page consulted
R-454B refrigerant charge38.10 ozBrochure BRO_260640.92 ozsenville.ca, SENA-12HF
Indoor unit W × H × D, weight33 7/16 × 11 9/16 × 8 1/16 in; weight not publishedBrochure BRO_260633.4 × 11.76 × 9.18 in; 24.25 lbsenville.ca, SENA-12HF
Outdoor unit W × H × D, weight31 7/8 × 23 × 11 in; weight not publishedBrochure BRO_260630.31 × 21.65 × 12.20 in; 82.67 lbsenville.ca, SENA-12HF
Electrical protection208/230 V; MCA 10.5 A; MOP 15 ABrochure BRO_2606208/230 V; MCA 12 A; max. fuse 15 Asenville.ca, SENA-12HF
DehumidificationNot published by the manufacturerin brochure BRO_26061.4 L/hsenville.ca, SENA-12HF
Indoor fan speeds5 speeds · 253 to 394 CFMBrochure BRO_26064 speeds · 240 to 530 CFMsenville.ca, SENA-12HF
Stated heating / cooling range−30 to 24 °C / −15 to 48 °CBrochure BRO_2606Heating down to −30 °C; cooling range not publishedsenville.ca, SENA-12HF
Certified sheet

The AHRI values, as NEEP publishes them

Certified valueZEPHYR CB25SENVILLE AURA
Seasonal efficiency
SEER22325.4
EER212.2513.4
HSPF2 Region IV1010.5
HSPF2 Region V98
Heating at 8.3 °C (47 °F)
Capacity min. / rated / max., BTU/h3,000 / 12,000 / 13,0003,800 / 12,000 / 16,000
COP min. / rated / max.4 / 3.91 / 3.174.84 / 3.74 / 3.35
Heating at −8.3 °C (17 °F)
Capacity min. / rated / max., BTU/h2,550 / 10,800 / 12,0005,300 / 12,000 / 12,800
COP min. / rated / max.3.74 / 2.4 / 2.512.22 / 2.51 / 1.75
Heating at −15 °C (5 °F)
Capacity min. / rated / max., BTU/h2,000 / 11,000 / 11,0004,100 / 11,500 / 11,500
COP min. / rated / max.1.47 / 2 / 21.72 / 1.8 / 1.8
Coldest published point (different temperatures)
Test temperature−25 °C (−13 °F)−30 °C (−22 °F)
Capacity min. / max., BTU/h1,000 / 6,1002,000 / 5,900
COP min. / max.0.81 / 1.381.17 / 1.25
Cooling
Rated capacity at 35 °C (95 °F), BTU/h12,00012,000
Capacity min. / rated / max. at 35 °C, BTU/h3,000 / 12,000 / 13,0003,800 / 12,000 / 13,500
Certification and refrigerant
AHRI certificate · NEEP record215414830 · 418302215735296 · 385685
ENERGY STAR, cold climateYes; cold climate: yesYes; cold climate: yes
RefrigerantR-454B · GWP 466 · class A2LR-454B · GWP 466 · class A2L

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Values: NEEP records 418302 and 385685, consulted November 10, 2026. GWP: IPCC Fourth Assessment Report (AR4); safety class: ASHRAE 34.

Questions

Questions about these two heat pumps

Which one heats more in deep cold?

At −15 °C, the only cold temperature where both certificates give a value, the CB25 is certified at 11,000 BTU/h (COP 2) and the AURA at 11,500 BTU/h (COP 1.8). Further down, the published temperatures are no longer the same: 6,100 BTU/h at −25 °C for the CB25, 5,900 BTU/h at −30 °C for the AURA. These last two figures do not compare directly.

Why does the CB25 cost less to heat in the estimate, when the AURA has the higher SEER2?

Heating is calculated with HSPF2 Region V, the cold region of the standard: 9 for the CB25, 8 for the AURA. SEER2 is only used for cooling, where the AURA (25.4) is ahead of the CB25 (23). In Region IV, which is milder, the order reverses: 10.5 for the AURA, 10 for the CB25.

Is the HAXXAIR V2D the same as the CB25?

The HAXXAIR V2D R-454B 12,000 BTU (AHRI 216012011) has the same NEEP-certified values as the ZEPHYR CB25 (AHRI 215414830), point by point. The certificates, model numbers and indoor units are separate. Everything this page says about the CB25's certified figures therefore applies to the V2D; the features and documents may differ.

What about the MIDEA28, the DIRECT AIR Heat Xtreme Pro and the BOSCH MAX PERFORMANCE?

At 12,000 BTU, these three units have the same NEEP-certified values as the SENVILLE AURA R454B, with separate AHRI certificates (215471381, 216571373 and 215223282). Our page "MIDEA28 and MIDEA35: their other names" puts them side by side.

Why two figures for the CB25 at −15 °C?

The ZEPHYR brochure (BRO_2606) prints 10,600 BTU/h at −15 °C; the AHRI certificate, published by NEEP, gives 11,000 BTU/h. The page shows both and relies on the certificate for any comparison, since it is the value measured under the standard.

Which one is quieter?

Both manufacturers publish sound levels without stating the distance or the method: 28 to 46 dB(A) indoors for the CB25, 24 to 47 dB(A) for the AURA; 53 and 57 dB(A) outdoors. Possibly measured in different ways, these figures do not allow a ranking.

Are they eligible for Hydro-Québec programs?

Both are ENERGY STAR cold-climate certified. LogisVert eligibility is checked against Hydro-Québec's official list, which can change; this page states no amount.

Both are on the AirGreen site.

A question about the CB25 or the AURA for your home? Talk it over with our team.

Sources

Documents consulted

NEEP, record 418302 (AHRI 215414830)ZEPHYR ZE-12CB25I / ZE-12CB25O · consulted November 10, 2026
NEEP, record 385685 (AHRI 215735296)SENVILLE SENA-12HF-IGG / SENA-12HF-OG · consulted November 10, 2026
NEEP, records of the twin unitsHAXXAIR 203876 (AHRI 216012011); MIDEA 387358; DIRECT AIR 382480; BOSCH 392021 · consulted November 10, 2026
ENERGY STAR, heat pump directoryZEPHYR 3624587 (certified Jan. 20, 2025); SENVILLE ES_1127750 (certified May 6, 2026); cold climate: yes for both · consulted November 10, 2026
ZEPHYR CB25 brochure, code BRO_2606French, one page, undated · consulted November 10, 2026
SENVILLE, SENA-12HF (AURA) product pagesenville.ca, specification sheet · consulted November 10, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5
NRCan, HOT2000 climate mapMontréal Intl: 4,167 degree-days (base 18 °C), design temperature −23.1 °C
IPCC AR4 and ASHRAE 34R-454B: GWP 466; safety class A2L