The air and cooling you pay for should reach the room, not the ceiling. Ducts and refrigerant piping in Montréal, Laval, Longueuil, the South Shore and the North Shore
A leaking duct makes the fan work harder, and its power climbs much faster than the airflow. See it in the lab, then put a price on it.
15% leakage is not 15% more on the fan bill.
Slide the leakage and watch the fan speed up. To deliver the same air to the rooms it must push more, and its power follows the cube of the airflow.
Make the duct leak
compared with a leak-free duct
Fan laws: power varies with the cube of airflow. Order of magnitude, to be confirmed on site.
Leaks are paid twice: at the fan, and in lost heat.
Enter your fan power and running hours. If ducts run through an attic or on the roof, add the heat that escapes outdoors.
Your numbers
The starting values are an example. Replace them with yours.
before taxes, order of magnitude
Fan: fan laws (power ∝ airflow³). Loss outside the envelope: 1.2 kJ/m³·°C × lost airflow × temperature gap × hours, at the electricity price chosen. Demand charge not included.
Inspect my ductsSix signs the air is getting lost on the way.
The rooms farthest from the fan are always the least comfortable.
Air escapes through a poorly sealed fitting or a loose section.
Grey streaks around a joint give away a long-standing leak.
A poorly insulated cold duct wets ceiling tiles in summer.
Often low refrigerant, so a leak to find.
Clogged drain, reversed slope or stopped pump.
Ducts, refrigerant piping and drains: what is ours, and what goes to a partner.
Supply and return networks for our ventilation and cooling systems.
15.8Moved diffusers, added branches, coordination with the general contractor.
15.8Sealed joints, insulated ducts outside the heated space, vapour barrier redone.
15.8Heat pumps, cassettes, VRF, walk-ins. Leak test before charging.
15.10Drains, slopes and condensate pumps of our equipment.
15.10Handled by a licensed partner, coordinated by us.
PartnerFrom inspection to start-up.
Walk of accessible ducts, equipment and the zones that complain.
What we saw, with photos, and what is outside our licence.
Final price confirmed before work.
Scheduled around your business hours and your contractor.
Operating checks and, for refrigerant, a leak test before charging.
Every pipe has its licence. We tell you who does what.
Ducts, grilles, diffusers, air exchangers, make-up air, duct-mounted humidifiers.
Heat pumps, air conditioning, VRF, walk-in coolers, refrigerant piping.
Equipment power, controls, thermostats, sensor wiring (CMEQ).
- Natural gas or propane piping15.2
- Hot-water heating, boilers15.4
- Plumbing, building drain connection15.5
AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8, 15.10 and 16. Anything outside those subclasses goes to a partner who holds the right licence, and we tell you before you sign.
What the law and physics require.
Tap a card for details.
The mistakes we see most often.
Prohibited in Québec, and the refrigerant escapes again.
It dries and peels off. The joint leaks again.
Every kink slows the air and makes the fan strain.
It steals air from nearby rooms without fixing the problem.
Heat lost in winter, condensation in summer.
Beyond the manufacturer’s limits, capacity drops and the warranty may be void.
What people ask us about ducts and piping.
How do we know if our ducts leak?+
The signs: poorly served rooms at the end of the run, whistling joints, dust around fittings, a fan that strains. An inspection of joints, fittings and accessible sections gives a first picture. If your engineer’s specification requires a leakage test, we cover it in the quote.
Do you do gas, hot-water or plumbing piping?+
No. Our piping is refrigerant (15.10) and the condensate drains of our equipment. Gas (15.2), hydronic heating (15.4) and plumbing (15.5) go to a licensed partner, and we tell you before you sign.
What does refrigerant piping include?+
The lines between indoor and outdoor units: wall heat pumps and cassettes, VRF systems, split rooftop units, walk-in coolers. The leak test is done before the refrigerant charge, as the Halocarbons Regulation requires (s. 9).
My system is low on refrigerant. Can you just recharge it?+
No, and nobody should: in Québec, a leak test is mandatory before any recharge (Halocarbons Regulation, s. 9). A system that is low on refrigerant has a leak. We find it, repair it, then recharge.
Must our units be tested every year?+
Units of 20 kW and up: yes, a leak test at least once a year, no more than 15 months apart. After a leak repair, a new test is done between day 30 and day 60 (s. 21.1).
Our ducts run through an attic or on the roof. Is that a problem?+
That is where leaks cost the most: heated or cooled air that escapes is lost outside. Sealed joints and continuous insulation limit the loss. The calculator in section 02 gives you an order of magnitude.
Why are some rooms too hot and others too cold?+
Often the ducts were laid out for an old floor plan. Added partitions, moved diffusers or closed dampers change the distribution. We look at the whole network before proposing a fix.
Can you modify the ducts during a fit-out?+
Yes, it is ventilation work (15.8). We coordinate with your general contractor on the sequence of work, especially before ceilings close.
Do you clean ducts?+
Yes, it is a separate service. See the air duct cleaning page.
The condensate drain overflows. What do we do?+
Switch the unit off if water nears anything electrical. The unit’s drain, slope or condensate pump are part of our work. If the connection to the building plumbing must change, a licensed plumber (15.5) handles it.
Are the calculator numbers exact?+
They are orders of magnitude, calculated with the fan laws and Hydro-Québec rates of April 1, 2026. The real numbers come from a visit and your bills.
No question matches. Call us at 514 316-2973, we will answer.
Your need often touches a neighbouring service.
The services most often combined with this one, plus the full needs search.
We find where the air is lost, then give you a firm price.
Free on-site estimate across Greater Montréal. Quote in 24 h, final price confirmed before work.
Sources checked on November 2, 2026.
- Halocarbons Regulation (CQLR, c. Q-2, r. 29), ss. 9 and 21.1, current to June 1, 2026.
- Hydro-Québec, Electricity rates in effect April 1, 2026: rates G and M.
- ASHRAE Handbook, HVAC Systems and Equipment, Fans chapter: fan laws.
- ASHRAE Handbook, Fundamentals, Psychrometrics chapter: air properties (ρ·cp ≈ 1.2 kJ/m³·°C).
- Régie du bâtiment du Québec, licence subclasses 15.2, 15.4, 15.5, 15.8 and 15.10.
Amounts shown are indicative estimates, before taxes. Only Hydro-Québec, Énergir and the responsible bodies confirm a rate or an approved incentive.