DETTSON AHV Air Handler | 3 Tons - 36000 BTU

In stock

Dettson’s 3-ton Duotec AHV air handler: variable-speed ECM motor, dual voltage and 5 to 20 kW EHIA backup heat.

Model numberAHV120017

1,600 CFMmax. airflow (range from 415 CFM)
5 to 20 kWEHIA kits permitted
1/2 HPvariable-speed ECM motor
115/208/230 V · single phaseVariable-speed ECM motorBackup heat up to 20 kWFilter not suppliedCoil not included
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberAHV120017
ManufacturerDettson
SeriesDuotec AHV
Size3 tons (36,000 BTU)
MotorVariable-speed ECM, 1/2 HP
Airflow415 to 1,600 CFM
Backup heat5 to 20 kW EHIA kits

Up to 20 kW of backup heat and an ECM motor: the 3-ton Duotec

What the AHV120017 is for

A central heat pump needs an indoor cabinet to push air through the ducts and, in Quebec, backup heat for the deep cold. The Dettson AHV120017, from the Duotec series, combines both in a 3-ton (36,000 BTU) size: a 1/2 HP variable-speed ECM motor and the option of adding an EHIA electric heat kit. The heat pump coil goes in a separate cabinet.

It suits cottages and mid-sized homes switching to a central heat pump, or replacing an old air handler on existing ductwork.

Backup heat: what Dettson permits

For this size, Dettson permits 5, 10, 15 and 20 kW EHIA kits, each tied to a motor tap: D for 5 kW, C for 10 kW, B for 15 to 20 kW. The kits are factory approved and installed in the field. If you do not want electric backup heat, the EHIA00KN10 kit (0 kW) is provided for that purpose.

Power, airflow and installation

The cabinet is dual voltage: 115, 208 or 230 V, single phase. Without a heater, minimum ampacity is 6.5 A at 120 V, 3.8 A at 208 V and 3.3 A at 240 V, with 15 A maximum overcurrent protection. With a kit, the circuit is sized for the kit chosen.

The ECM motor covers a range of 415 to 1,600 CFM (196 to 755 L/s), which leaves room to set the airflow for the coil and the outdoor unit. The cabinet installs upflow, downflow, horizontal left or horizontal right. The filter is not supplied: Dettson requires a remote filter grille or other means of filtration.

Grant and warranty

Sold alone, this air handler has no certified efficiency rating and does not qualify for the LogisVert grant, which follows the certified outdoor unit + air handler pair. If you are replacing the complete system, we check that the pair qualifies before you sign. Dettson warrants parts for 5 years in residential use; labour is not covered by the manufacturer.

Installation by AirGreen

Our family business, established in Montreal for more than fifteen years, holds RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work. We therefore handle the project from start to finish: free on-site estimate, written quote, choice of EHIA kit and coil, installation of the cabinet and filter grille, connections, then commissioning with the airflow set.

Our technicians travel to Montreal, Laval, Longueuil, the South Shore and the North Shore.

Ask for a free estimate for your central heat pump, and find out about our financing options.

01 · What it is for

The Duotec air handler for 3-ton central heat pumps

The AHV120017 pushes the air of a central heat pump with a variable-speed ECM motor. The coil sits in a separate cabinet; backup heat, from 5 to 20 kW, is added with an EHIA kit.

  • Cottages and mid-sized homes with a 3-ton central heat pump
  • Projects that want 15 or 20 kW of electric backup heat in the cabinet
  • Buildings where the available supply is 115 V, 208 V or 230 V
  • Upflow, downflow or horizontal installation, depending on the mechanical room
5 to 20 kW of backup heatFor the AHV12, Dettson permits 5 kW (tap D), 10 kW (tap C) and 15 to 20 kW (tap B) EHIA kits.
415 to 1,600 CFMThe airflow range of the variable-speed ECM motor, or 196 to 755 L/s.
Dual voltageOne model for a 115, 208 or 230 V single-phase supply.
Compatible with
EHIA05KNEHIA10KNEHIA15KBEHIA20KBEHIA00KN10
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesDuotec AHV
TypeDual-voltage air handler, no coil
MotorVariable-speed ECM, 1/2 HP
Power supply115/208/230 V, 1 ph (table: 120 / 208 / 240 V)
Airflow415 to 1,600 CFM (196 to 755 L/s)
Min. circuit ampacity (no heater)6.5 A (120 V) · 3.8 A (208 V) · 3.3 A (240 V)
Max. overcurrent protection (no heater)15 A (120 V) · 15 A (208 V) · 15 A (240 V)
Permitted EHIA kits5 kW (tap D) · 10 kW (tap C) · 15 to 20 kW (tap B)
Without heatEHIA00KN10 kit (0 kW)
FilterNot supplied (remote filter grille required)
PositionsUpflow, downflow, horizontal left or right
CoilNot included (separate coil cabinet)
Model numberAHV120017
03 · Before installing

What to know before installing

  • Sold alone: the LogisVert grant follows the certified outdoor unit + air handler pair. Bought alone, this air handler does not qualify.
  • Only Dettson-approved EHIA kits are permitted, installed in the field with the motor tap shown for each rating; without heat, the EHIA00KN10 kit (0 kW) is used.
  • Without heater: minimum ampacity of 6.5 A at 120 V, 3.8 A at 208 V and 3.3 A at 240 V; 15 A maximum overcurrent protection. With a kit, the supply is sized for the kit.
  • Filter not supplied: plan for a remote filter grille or other means of filtration.
  • Coil not included: it goes in a separate coil cabinet.
  • Dettson warranty: parts 5 years in residential use. Labour is not covered by the manufacturer.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces – air handlers
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

How much backup heat can be installed?

For the AHV12, Dettson permits 5 kW (EHIA05KN), 10 kW (EHIA10KN), 15 kW (EHIA15KB) and 20 kW (EHIA20KB) EHIA kits. The rating is chosen based on the house and the available supply; we determine it during the estimate.

What does the ECM motor bring?

This cabinet’s variable-speed ECM motor covers a range of 415 to 1,600 CFM. The airflow is set to suit the coil and the outdoor unit, instead of being limited to a few fixed speeds.

Can it be connected to 115 V?

Yes. Dettson rates it for 115, 208 or 230 V, single phase. At 120 V, without a heater, minimum ampacity is 6.5 A and maximum overcurrent protection is 15 A. With a heat kit, we size the supply for the kit.

Are the filter and coil included?

No. The coil goes in a separate cabinet, and Dettson requires a remote filter grille or other means of filtration. We include both in the quote.

Does it qualify for the LogisVert grant?

Not when bought alone: Hydro-Québec’s grant follows the certified outdoor unit + air handler pair. For a complete system, we check eligibility in the quote.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your 3-ton Dettson Duotec air handler, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.