DETTSON AHV Air Handler | 4 Tons - 48000 BTU

In stock

Dettson’s 4-ton Duotec AHV air handler: 3/4 HP ECM motor, 540 to 2,000 CFM and EHIA backup heat up to 25 kW.

Model numberAHV160021

2,000 CFMmax. airflow (range from 540 CFM)
5 to 25 kWEHIA kits permitted
3/4 HPvariable-speed ECM motor
115/208/230 V · single phaseVariable-speed ECM motorBackup heat up to 25 kWFilter not suppliedCoil not included
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberAHV160021
ManufacturerDettson
SeriesDuotec AHV
Size4 tons (48,000 BTU)
MotorVariable-speed ECM, 3/4 HP
Airflow540 to 2,000 CFM
Backup heat5 to 25 kW EHIA kits

The 4-ton Duotec: 540 to 2,000 CFM and up to 25 kW of backup heat

An air handler for large homes

In a large home heated and cooled by a central heat pump, the indoor cabinet has to move a lot of air and hold backup heat for the winter. The Dettson AHV160021, from the Duotec series, covers both needs in the 4-ton (48,000 BTU) size: a 3/4 HP variable-speed ECM motor, a range of 540 to 2,000 CFM (255 to 944 L/s) and EHIA heat kits up to 25 kW.

The cabinet contains no coil: the coil goes in a separate cabinet, matched with the outdoor unit of the heat pump or air conditioner.

Six backup heat ratings

Dettson permits six EHIA kits for the AHV16: 5, 7, 10, 15 and 20 kW, set on motor tap D, and 25 kW, set on tap B. The kits are factory approved and installed in the field. Without electric heat, the EHIA00KN10 kit (0 kW) is used. The choice depends on the house and the electrical service: it is a decision we make with you, figures in hand.

Connection: 115, 208 or 230 V

Like the other Duotec AHV models, this cabinet is dual voltage. Without a heater, Dettson specifies a minimum ampacity of 9.5 A at 120 V, 5.5 A at 208 V and 4.8 A at 240 V. Maximum overcurrent protection is 20 A at 120 V and 15 A at 208 V and 240 V. With a heat kit, the supply is sized for the kit.

What to plan before installation

The filter is not supplied: Dettson requires a remote filter grille or other means of filtration. The cabinet installs upflow, downflow, horizontal left or horizontal right, which leaves room to manoeuvre in a crowded mechanical room.

Sold alone, it has no certified efficiency rating and does not qualify for the LogisVert grant, which follows the certified outdoor unit + air handler pair. Dettson warrants parts for 5 years in residential use; labour is not covered by the manufacturer.

Installed by AirGreen

AirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work: the same crew assesses your home free of charge, writes the quote, installs the cabinet, coil, EHIA kit and filter grille, makes the electrical and refrigerant connections, then sets the airflow at commissioning.

We serve homeowners in Montreal, Laval and Longueuil, as well as on the South Shore and the North Shore.

Ask for your free estimate and bring us your questions about financing your system.

01 · What it is for

A 4-ton Duotec for large homes heated by a heat pump

The AHV160021 moves the air of a 4-ton central heat pump or air conditioner with a 3/4 HP variable-speed ECM motor. The coil sits in a separate cabinet, and electric backup heat is added with a 5 to 25 kW EHIA kit.

  • Large homes and cottages with a 4-ton central heat pump
  • Electric backup heat chosen from six ratings, from 5 to 25 kW
  • Replacing an air handler on an extensive duct system
  • Buildings supplied with 115 V, 208 V or 230 V
540 to 2,000 CFMThe range of the 3/4 HP variable-speed ECM motor, or 255 to 944 L/s.
Six backup heat kits5, 7, 10, 15 and 20 kW (tap D) or 25 kW (tap B) EHIA kits, per Dettson’s table for the AHV16.
Dual voltage115, 208 or 230 V single phase; without heater, 20 A maximum overcurrent protection at 120 V and 15 A at 208 or 240 V.
Compatible with
EHIA05KNEHIA07KNEHIA10KNEHIA15KBEHIA20KBEHIA25KBEHIA00KN10
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesDuotec AHV
TypeDual-voltage air handler, no coil
MotorVariable-speed ECM, 3/4 HP
Power supply115/208/230 V, 1 ph (table: 120 / 208 / 240 V)
Airflow540 to 2,000 CFM (255 to 944 L/s)
Min. circuit ampacity (no heater)9.5 A (120 V) · 5.5 A (208 V) · 4.8 A (240 V)
Max. overcurrent protection (no heater)20 A (120 V) · 15 A (208 V) · 15 A (240 V)
Permitted EHIA kits5 to 20 kW (tap D) · 25 kW (tap B)
Without heatEHIA00KN10 kit (0 kW)
FilterNot supplied (remote filter grille required)
PositionsUpflow, downflow, horizontal left or right
CoilNot included (separate coil cabinet)
Model numberAHV160021
03 · Before installing

What to know before installing

  • Sold alone: the LogisVert grant follows the certified outdoor unit + air handler pair. Bought alone, this air handler does not qualify.
  • Without heater: minimum ampacity of 9.5 A at 120 V, 5.5 A at 208 V and 4.8 A at 240 V; maximum overcurrent protection of 20 A at 120 V and 15 A at 208 V and 240 V. With a kit, the supply is sized for the kit.
  • Only Dettson-approved EHIA kits are permitted, with the motor tap shown; the EHIA00KN10 kit means no electric heat (0 kW).
  • Filter not supplied: a remote filter grille or other means of filtration must be provided.
  • Coil not included: it goes in a separate coil cabinet.
  • Dettson warranty: parts 5 years in residential use. Labour is not covered by the manufacturer.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces – air handlers
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

Which backup heat ratings are possible?

For the AHV16, Dettson permits the EHIA05KN (5 kW), EHIA07KN (7 kW), EHIA10KN (10 kW), EHIA15KB (15 kW) and EHIA20KB (20 kW) kits on tap D, and the EHIA25KB (25 kW) on tap B. Without heat, the EHIA00KN10 kit is used.

Can it run on 115 V?

Yes. At 120 V, without a heater, Dettson specifies a minimum ampacity of 9.5 A and maximum overcurrent protection of 20 A. At 208 V and 240 V, minimum ampacity drops to 5.5 A and 4.8 A, with 15 A protection.

Is the filter supplied?

No. Dettson requires a remote filter grille or other means of filtration. We build it into the return air and show it in the quote.

Is the coil included?

No. The heat pump or air conditioner coil goes in a separate cabinet, chosen based on the outdoor unit.

Does it qualify for the LogisVert grant?

Not when bought alone: Hydro-Québec’s grant follows the certified outdoor unit + air handler pair. For a complete system, we check eligibility in the quote.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton Dettson Duotec air handler, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.