Potable water safety
Two nested copper tubes with vented leak ports separate potable water from boiler water, so a leak shows at the fittings instead of contaminating the water.
A tank rarely runs out over a day. It runs out over an hour. Describe your busiest hour.
An indirect’s first-hour rating depends on the boiler; the test conditions are in the spec sheet. Method: the first-hour rating should equal or exceed the hot water of your busiest hour (Natural Resources Canada). CAA-Québec rule of thumb: 40 gal for 1 or 2 people, 60 gal for 3 or 4, 80 to 100 gal for 5 or more. Volumes: Québec.ca.
Two nested copper tubes with vented leak ports separate potable water from boiler water, so a leak shows at the fittings instead of contaminating the water.
As with the TurboMax, potable water is heated on demand in the coils; the 80 gal tank holds boiler water.
The 80-5 has 30.9 sq ft of exchange and 15 gpm maximum flow, for 454 gal first hour at 140 °F at full capacity.
Thermo 2000 covers the tank and coils for 15 years residential (10 years commercial) and parts for 2 years.
It travels upright. Measure the ceiling at the spot and the narrowest door on the way.
Unit: 73.75 in tall (1873 mm), 24 in across (610 mm), about 355 lb shipping weight. The clearances the manufacturer requires are checked on site.
The year it was made is on the tank’s rating plate. Enter it.
Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.
AirGreenFree visit and quote, coordination of the work.
HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).
PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).
YouA photo of the rating plate, the spot and the stairs saves us a trip.
Manufacturer data. Detailed sources at the bottom of the page.
No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.
Yes. An indirect water heater has no element: it is heated by water from a boiler. The boiler connection is done by a hydronic heating contractor (RBQ 15.4) and the water connections by a master pipe-mechanic (CMMTQ).
To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.
Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.
It delivers 1,718 L of hot water in the first hour, with the boiler stated in the spec sheet. CAA-Québec’s rule of thumb suggests 40 gal for 1 or 2 people, 60 gal for 3 or 4 and 80 to 100 gal for 5 or more; the “Your home” tool above accounts for your busiest hour.
AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ) and the boiler connection by a hydronic heating contractor (RBQ 15.4).
Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.
Book my free estimateCosts shown are indicative estimates before tax.
A large home heated with hot water often has hot water needs to match its size: three bathrooms, a deep tub, sometimes a multigenerational unit on the ground floor. The Thermo 2000 DoubleMax 80-5 indirect water heater relies on the home’s electric boiler to heat an 80 US gallon tank through a 30.9 sq. ft. double-wall copper heat exchanger. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.
The DoubleMax 80-5 comes into its own when several people use hot water at the same hour. In a home where two generations live under one roof, morning showers, the dishwasher and the washing machine add up. A family of five with a large freestanding tub is another typical example. For a more modest home, a smaller tank from the same series is often enough; we make the comparison with you during the visit.
This tank works with an electric boiler already in place or installed at the same time, as part of a radiant floor project or the replacement of an old heating system.
Thermo 2000’s values read as first hour / continuous, in US gallons per hour, with cold water at 40 °F and boiler water at 180 °F. The gap between the two figures shows the role of the tank. With a 50,000 BTU/h (15 kW) boiler, the DoubleMax 80-5 delivers 166 / 86 US gallons at 110 °F: the first hour is much more generous than the continuous rate, because the 80 US gallons already hot add to what the boiler produces during that time.
That is exactly what a large tub needs. It fills from the stored water, in a few minutes, without waiting for the boiler. Once the reserve is drawn down, continuous production takes over, then the tank rebuilds while the household sleeps or is at work.
The same tank produces much more with a stronger boiler. Here are three lines from the manufacturer’s table, at 110 °F, 140 °F and 160 °F (first hour / continuous):
An electric boiler is first sized to heat the house. We start from that capacity to tell you what the DoubleMax 80-5 will really deliver, rather than quoting the most flattering line of the table. If a gap remains between your needs and the expected output, we discuss it before ordering.
The DoubleMax exchanger is made of double-wall copper pipes, wound in parallel helicoidal lines. Two thicknesses of metal separate the boiler water from the potable water. This design is valued when the heating water contains an additive such as antifreeze, or when the inspection requires double separation. The copper components meet the NSF 61 standard and the low lead requirements for potable water.
The DoubleMax 80-5 is 73 3/4 in high and 24 in in diameter. It is a slender format that takes little floor space but requires enough free height under the joists, ducts and piping, not forgetting the space needed above for the fittings. We measure the mechanical room or basement before confirming the model. The tank weighs 355 lb, plus the weight of the water: it must sit on a solid, level floor, near a drain.
The tank control is connected to the electric boiler, usually with hot water priority. The boiler connection is 1 1/2 in NPT male; the size of the potable water connections is confirmed with the manufacturer’s sheet at the quote stage. If you choose to store water at 140 °F or more, a thermostatic mixing valve brings the water delivered to the taps back to a safe temperature. According to Thermo 2000, the 15 gpm maximum flow must be reduced for high-temperature and continuous-flow applications; we take this into account when choosing the piping.
In residential use, Thermo 2000 provides a 15-year warranty on the tank and copper coils. In commercial use, this warranty is 10 years. Mechanical parts are warranted for 2 years. The applicable terms are confirmed in writing with the quote.
AirGreen is a family business established in Montreal, active in heating, ventilation and air conditioning for more than fifteen years and holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Our work includes:
We serve Montreal, Laval, Longueuil, Boucherville, Saint-Bruno, Vaudreuil-Dorion, Mirabel, Terrebonne and the entire South Shore and North Shore. The on-site estimate is free, the quote is written and financing is available.
Request your free quote for the Thermo 2000 DoubleMax 80-5. Send us a photo of your electric boiler and the height of your basement: we will confirm the right format before ordering.