A.C.R. 45° Copper Elbow (C × C)

In stock

The 45° elbow to offset a refrigerant line without a sharp turn.

AirGreen codeAG-RC-00508

45°gentle direction change
1/4 to 2-5/8 in11 tube sizes
C × Cbrazed on both ends
ACR copperBrazed fitting
Diameter
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-RC-00508
MaterialCopper
ConnectionBraze, female × female
Angle45°
SoldEach

The A.C.R. 45° copper elbow changes the direction of a refrigerant line by half a right angle. Both ends are female (C × C): the tube slides in, then each joint is brazed. It is mostly used in pairs, to offset a line and route it around an obstacle.

The fitting for offsets and bypasses

When a beam, a ventilation duct or an existing pipe is in the way, two 45° elbows joined by a short piece of tube form an offset that goes around it, with a gentler change of direction than two 90° turns. The 45° elbow is also used to change levels along a wall or to enter a cabinet at an angle.

Eleven diameters, from 1/4 in to 2-5/8 in

It is available for tubes of 1/4, 3/8, 1/2, 5/8, 3/4, 7/8, 1-1/8, 1-3/8, 1-5/8, 2-1/8 and 2-5/8 in outside diameter, from small liquid lines up to commercial circuits.

Getting an offset right

  • Measure the gap to cross, then cut the piece of tube between the two elbows to suit.
  • Line up both elbows in the same plane before brazing, for a straight, clean line.
  • Cut square, deburr and clean each tube end.
  • Braze under a light flow of dry nitrogen to keep the inside of the joints clean.

Work on a refrigerant circuit is reserved for a qualified refrigeration technician.

Supplied and installed by AirGreen in Greater Montréal

Our refrigeration technicians install refrigerant piping in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. To check availability or get a quote, call us at 514 316-2973 or email sales@airgreen.ca with the diameter and quantity.

01 · What it is for

Going around an obstacle smoothly

Two 45° elbows make an offset around a beam, a duct or existing piping.

  • Offsets around a beam, a ventilation duct or an existing pipe
  • Changing a line’s level along a wall
  • Angled entry into a box or through a wall
  • Lines where you want to avoid back-to-back 90° turns
Gentle turnA 45° angle restricts the refrigerant less than a 90° turn.
Clean offsetTwo 45° elbows and a short piece of tube are enough to clear an obstacle.
Female × femaleThe tube slides into each end, then the joint is brazed.
02 · Sizes

11 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

DiameterAirGreen code
1/4 inAG-RC-00501
3/8 inAG-RC-00502
1/2 inAG-RC-00503
5/8 inAG-RC-00504
3/4 inAG-RC-00505
7/8 inAG-RC-00506
1-1/8 inAG-RC-00507
1-3/8 inAG-RC-00508
1-5/8 inAG-RC-00509
2-1/8 inAG-RC-00510
2-5/8 inAG-RC-00511

Outside diameter of the copper tube, in inches.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

Type45° elbow
ConnectionBraze, C × C (female × female)
MaterialCopper
UseRefrigerant circuits (ACR)
SoldEach
AirGreen codeAG-RC-00508
04 · Before installing

What to know before installing

  • The size is the outside diameter of the tube it connects.
  • For an offset, measure the distance to clear before cutting the tube between the two elbows.
  • Line up both elbows in the same plane before brazing.
  • Braze with a light flow of dry nitrogen; this work is reserved for a qualified technician.
05 · Goes with

You may also need

Same category
Copper fittings
See all
06 · Questions

Frequently asked questions

Why two 45° elbows instead of two 90° ones?

To clear an obstacle, two 45° elbows give a smoother offset: the refrigerant changes direction less abruptly and the assembly often takes less width.

Is the size the tube or the fitting?

The outside diameter of the tube. A 7/8 in elbow takes a tube with a 7/8 in outside diameter.

Is there a street version of the 45°?

We offer this 45° elbow as female × female (C × C). The street elbows in our range are 90° elbows.

Can you install it?

Yes. Our technicians run the refrigerant piping when they install your heat pump, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

45° elbows for well-routed lines

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.