A.C.R. Copper 90° Elbow – Short Radius (C × C)

In stock

The compact copper elbow for a 90° turn where space is tight.

AirGreen codeAG-RC-00104

1/4 to 2-5/8 in11 tube sizes
Short radiustight turn, small footprint
C × Cbrazed on both ends
ACR copperBrazed fitting
Diameter
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-RC-00104
MaterialCopper
ConnectionBraze, female × female
Angle90°, short radius
SoldEach

The A.C.R. copper short-radius 90° elbow turns a refrigerant line at a right angle over a very short distance. Both ends are female (C × C): the tube fits into them, then each joint is brazed. It is the elbow for places where space is tight.

When to choose a short-radius elbow

We install it near the connections of an outdoor unit or a coil, between two joists, in a closet or behind a unit, in short anywhere a long-radius elbow or a bend would not fit. The line stays tight to the wall or the corner, which also makes for a neater installation.

Short radius or long radius?

  • Short radius: compact, for tight spaces.
  • Long radius: a wider curve, less pressure drop; preferred on a long suction line when space allows.
  • Bend: on soft tubing, bending with a tube bender avoids a joint when the available radius allows.

Eleven diameters, from 1/4 in to 2-5/8 in

The elbow is offered for tubes of 1/4, 3/8, 1/2, 5/8, 3/4, 7/8, 1-1/8, 1-3/8, 1-5/8, 2-1/8 and 2-5/8 in outside diameter. Each size has its own AirGreen code, shown when you select it.

Good practices

Cut the tube square, deburr it and clean it before fitting, then braze under a light flow of dry nitrogen. Work on a refrigerant circuit is reserved for a qualified refrigeration technician.

Supplied and installed by AirGreen across Greater Montréal

Our refrigeration technicians install the refrigerant piping on every installation in Montréal, Laval, Longueuil, the South Shore and the North Shore. RBQ licence 5645-9605-01. To check availability of a size or get a quote, call us at 514 316-2973 or email sales@airgreen.ca with the diameter and quantity.

01 · What it is for

A 90° turn in a tight space

The short radius turns as close as possible: the line stays tight to the wall, the corner or the unit.

  • Line exits close to an outdoor unit or a coil
  • Tight passages between joists, in a closet or behind equipment
  • Line returns hugging a wall or a corner
  • Small refrigeration circuits where every inch counts
Small footprintThe turn happens over a short distance, where a long radius would not fit.
Female × femaleThe tube slides into each end, then the joint is brazed.
Eleven sizesFrom 1/4 in small liquid lines to 2-5/8 in commercial circuits.
02 · Sizes

11 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

DiameterAirGreen code
1/4 inAG-RC-00101
3/8 inAG-RC-00102
1/2 inAG-RC-00103
5/8 inAG-RC-00104
3/4 inAG-RC-00105
7/8 inAG-RC-00106
1-1/8 inAG-RC-00107
1-3/8 inAG-RC-00108
1-5/8 inAG-RC-00109
2-1/8 inAG-RC-00110
2-5/8 inAG-RC-00111

Outside diameter of the copper tube, in inches.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

Type90° elbow, short radius
ConnectionBraze, C × C (female × female)
MaterialCopper
UseRefrigerant circuits (ACR)
SoldEach
AirGreen codeAG-RC-00104
04 · Before installing

What to know before installing

  • The size is the outside diameter of the tube it connects.
  • On a long suction line, use a long radius where space allows.
  • Cut the tube square, deburr it and clean it before fitting.
  • Braze with a light flow of dry nitrogen; refrigerant circuit work is reserved for a qualified technician.
05 · Goes with

You may also need

Same category
Copper fittings
See all
06 · Questions

Frequently asked questions

Short radius or long radius: which one?

Short radius when space is tight. Long radius when you can afford it, especially on a suction line, because its wider bend restricts the refrigerant less.

Is the size the tube or the fitting?

The outside diameter of the tube. A 3/8 in elbow takes a tube with a 3/8 in outside diameter.

Can I bend the tube instead?

On soft tube, yes, with a bender, if there is room for the bend radius. The elbow is the answer in a corner too tight to bend.

Can you install it?

Yes. Our technicians run the refrigerant piping when they install your heat pump, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Compact elbows for tight spots

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.