A.C.R. Copper 90° Elbow – Short Radius (C × C)
The compact copper elbow for a 90° turn where space is tight.
AirGreen codeAG-RC-00105
514 316-2973 · sales@airgreen.ca
Quick facts
The A.C.R. copper short-radius 90° elbow turns a refrigerant line at a right angle over a very short distance. Both ends are female (C × C): the tube fits into them, then each joint is brazed. It is the elbow for places where space is tight.
When to choose a short-radius elbow
We install it near the connections of an outdoor unit or a coil, between two joists, in a closet or behind a unit, in short anywhere a long-radius elbow or a bend would not fit. The line stays tight to the wall or the corner, which also makes for a neater installation.
Short radius or long radius?
- Short radius: compact, for tight spaces.
- Long radius: a wider curve, less pressure drop; preferred on a long suction line when space allows.
- Bend: on soft tubing, bending with a tube bender avoids a joint when the available radius allows.
Eleven diameters, from 1/4 in to 2-5/8 in
The elbow is offered for tubes of 1/4, 3/8, 1/2, 5/8, 3/4, 7/8, 1-1/8, 1-3/8, 1-5/8, 2-1/8 and 2-5/8 in outside diameter. Each size has its own AirGreen code, shown when you select it.
Good practices
Cut the tube square, deburr it and clean it before fitting, then braze under a light flow of dry nitrogen. Work on a refrigerant circuit is reserved for a qualified refrigeration technician.
Supplied and installed by AirGreen across Greater Montréal
Our refrigeration technicians install the refrigerant piping on every installation in Montréal, Laval, Longueuil, the South Shore and the North Shore. RBQ licence 5645-9605-01. To check availability of a size or get a quote, call us at 514 316-2973 or email sales@airgreen.ca with the diameter and quantity.
A 90° turn in a tight space
The short radius turns as close as possible: the line stays tight to the wall, the corner or the unit.
- Line exits close to an outdoor unit or a coil
- Tight passages between joists, in a closet or behind equipment
- Line returns hugging a wall or a corner
- Small refrigeration circuits where every inch counts
11 sizes, one page
Each size has its own AirGreen code. Tap a row to select it.
| Diameter | AirGreen code |
|---|---|
| 1/4 in | AG-RC-00101 |
| 3/8 in | AG-RC-00102 |
| 1/2 in | AG-RC-00103 |
| 5/8 in | AG-RC-00104 |
| 3/4 in | AG-RC-00105 |
| 7/8 in | AG-RC-00106 |
| 1-1/8 in | AG-RC-00107 |
| 1-3/8 in | AG-RC-00108 |
| 1-5/8 in | AG-RC-00109 |
| 2-1/8 in | AG-RC-00110 |
| 2-5/8 in | AG-RC-00111 |
Outside diameter of the copper tube, in inches.
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- The size is the outside diameter of the tube it connects.
- On a long suction line, use a long radius where space allows.
- Cut the tube square, deburr it and clean it before fitting.
- Braze with a light flow of dry nitrogen; refrigerant circuit work is reserved for a qualified technician.
You may also need
A.C.R. Copper 90° Elbow – Long Radius (C × C)
A.C.R. Copper 90° Elbow – Short Radius, Male × Female (Street)
A.C.R. 45° Copper Elbow (C × C)
A.C.R. Soft Copper Tube – 50 ft Coil
Silver Brazing Rods
Abrasive Cloth for Copper (Plumber’s Sand Cloth)
A.C.R. Copper Cap
A.C.R. Copper 90° Elbow – Long Radius, Male × Female (Street)Copper fittingsSee all
Frequently asked questions
Short radius or long radius: which one?
Short radius when space is tight. Long radius when you can afford it, especially on a suction line, because its wider bend restricts the refrigerant less.
Is the size the tube or the fitting?
The outside diameter of the tube. A 3/8 in elbow takes a tube with a 3/8 in outside diameter.
Can I bend the tube instead?
On soft tube, yes, with a bender, if there is room for the bend radius. The elbow is the answer in a corner too tight to bend.
Can you install it?
Yes. Our technicians run the refrigerant piping when they install your heat pump, everywhere in Greater Montréal.
Compact elbows for tight spots
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 7, 2026.