Broan-NuTone HRV V160H80RT Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: V160H80RT
150 cfm net70% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 10 years
01 · Your home

Is it the right size for your home?

It delivers 150 cfm net. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 150 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
70%
At −25 °CCode: 55% minimum
82%
At 0 °CCertified at 36 cfm
Net airflowThe ducts cost it 9 cfm
0.2 in · test bench159 cfm
0.4 in · with ducts150 cfm

$17.57

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

18W
Running continuously
158kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 55% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that; 54% is still accepted for work started before October 17, 2027. This unit is rated at 70% at 65 cfm.

Airflow and efficiency at 0 °C: HVI directory, Section III. Efficiency at −25 °C: NRCan ENERGY STAR list. Cost: 18 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

+9 ptsMore efficient than the V160H65RT at the same airflow

This model and the V160H65RT deliver the same airflow (35 to 159 cfm at 0.2 in). Per the spec sheets, at 64 cfm and 0 °C its sensible recovery efficiency is 77% versus 68%; at −25 °C, NRCan's ENERGY STAR list gives 70.0% (65 cfm) versus 64.6% (69.1 cfm).

SeparateFresh-air and exhaust flows can be set separately

According to the manufacturer, the fresh-air and stale-air flows can be set separately; we set them at commissioning, room by room, following the CSA F326 standard.

70%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 65 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. The core transfers heat only.

2505434Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−9 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 159 to 150 cfm. Most spec sheets show only the first number, precisely because it looks better.

18 WMeasured at the airflow it actually runs at

Its 82% at 0 °C is certified at 36 cfm, the continuous airflow of a typical home. At that setting it draws 18 W, or about 158 kWh a year.

10 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

6 inWhat it needs on site

6 in ducts, top connection and a condensate drain. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.

04 · Installation

What it needs on site

6 in ductsCollar diameter
Top connectionTop ports
Condensate drainRequired
35 lbUnit weight
21 × 16.13 × 21.5 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
159 cfm
Net airflow at 0.4 in. w.g.
150 cfm
SRE at 0 °C (36 cfm)
82%
SRE at −25 °C (65 cfm)
70%
ASE at 0 °C
88%
Power draw
18 W
Efficacy
2.0 cfm/W
Type
HRV
Connection
Top ports
Duct collars
6 in
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
Dimensions (L × D × H)
21 × 16.13 × 21.5 in
Weight
35 lb
Power supply
120 V
HVI certification (Section III)
2505434
Warranty — core
10 years
Warranty — motors
5 years
Warranty — parts
5 years

Net airflow, efficiency at 0 °C and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505434). Efficiency at −25 °C: Natural Resources Canada's ENERGY STAR list, checked November 12, 2026. Annual consumption calculated at 18 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

On site, we set the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Broan-NuTone V160H80RT: the compact cabinet’s ceiling, with 82% at 36 cfm

In the 21 × 16.13 × 21.5 in. cabinet, the AI Series does not go beyond 159 cfm at 0.2 in. and 150 cfm at 0.4 in. The V160H80RT reaches that ceiling with a high-recovery core: according to its HVI file (Section III, No. 2505434), its sensible recovery efficiency is 82% at 36 cfm and 0 °C, and NRCan’s ENERGY STAR list (Nov. 12, 2026) gives it 70.0% at 65 cfm and −25 °C. It connects on top, with 6 in. ducts.

Same airflow as the V160H65RT, not the same core

The V160H65RT shares its cabinet and its airflow range, 35 to 159 cfm at 0.2 in. The gap is in heat recovery. According to both units’ spec sheets, at 64 cfm and 0 °C, the V160H80RT reaches 77%, versus 68% for the V160H65RT. In deep cold, on the same ENERGY STAR list: 70.0% at 65 cfm for the V160H80RT, 64.6% at 69.1 cfm for the V160H65RT.

Same difference on the Novoclimat list of July 13, 2026: the V160H80RT is listed everywhere in Quebec, the V160H65RT only for areas below 6,000 degree-days. For both, the spec sheet states that Novoclimat requirements are met with the Advanced Touchscreen wall control.

Ports on top or on the sides

If the ducts come in from the side instead, the V160H75RS shows the same figures: 159 cfm at 0.2 in. and 150 cfm at 0.4 in., 82% at 36 cfm and 0 °C (HVI), 70.0% at 65 cfm and −25 °C (NRCan). Its 6 in. ports exit on the sides, in a lower, wider cabinet of 23.38 × 16.13 × 19.13 in. Between the two, the location and the duct routing decide.

Setup and installation

At commissioning, we set the airflows room by room, following the CSA F326 standard; according to the manufacturer, the fresh-air and stale-air flows can be set separately. The unit requires a drain nearby, plugs into 120 V and defrosts by recirculation, using a motorized damper. It ships with a washable MERV 8 filter; optional upgrades are a disposable MERV 13 filter (V242851) or a HEPA-type media filter (V25000). And if you need more than 159 cfm, the V180H75RT takes over with 199 cfm at 0.2 in., in a larger 24.81 × 21 × 21.69 in. cabinet.

Specifications

  • Type: HRV (heat recovery ventilator), Broan-NuTone AI Series
  • ENERGY STAR (Canada): Yes, on NRCan’s ENERGY STAR list
  • Novoclimat: on the July 13, 2026 list, everywhere in Quebec, with the Advanced Touchscreen wall control (spec sheet condition)
  • Net airflow: 159 cfm at 0.2 in.; 150 cfm at 0.4 in.
  • Sensible recovery efficiency: 77% at 64 cfm and 0 °C (spec sheet); 82% at 36 cfm and 0 °C (HVI); 70.0% at 65 cfm and −25 °C (NRCan ENERGY STAR list, Nov. 12, 2026)
  • Voltage: 120 V, 60 Hz
  • Dimensions (W × D × H): 21 × 16.13 × 21.5 in.
  • Weight: 35 lb
  • Ducts: 6 in. diameter
  • Connection: top ports
  • Drain: required
  • Defrost: recirculation (motorized damper)
  • Washable MERV 8 filter included; optional disposable MERV 13 filter (V242851) or HEPA-type media filter (V25000)
  • HVI listing (Section III): No. 2505434
  • Manufacturer’s limited warranty, parts only: 5 years on parts, provided the core is maintained; 10 years on the core. Labour and shipping not covered. Residential use; original invoice required.

Sold and installed by AirGreen.

We install in Montreal, Laval, Longueuil, the North Shore and the South Shore. Call us at 514 316-2973 or write to sales@airgreen.ca.