Fantech ERV FIT 120E-D-EC-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 129 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 129 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$22.45
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 23 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
ECMEC motors: 2.2 cfm/W instead of 0.9
The -EC suffix replaces the AC motors with electronically commutated motors. Fantech's selection guide lists 2.2 cfm/W fan efficacy at 0 °C, versus 0.9 for the FIT 120E-D, and a 40 to 129 cfm range at 0.4 in. Every -EC version also includes the -D motorized damper.
-HCHard-connect version shipped without a cord
The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 120E-D-EC-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005123Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−17 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 129 cfm.
23 WMeasured at the airflow it actually runs at
Its 77% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 23 W, or about 201 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005123) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 129 cfm
- SRE at 0 °C (51 cfm)
- 77%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 80%
- Power draw
- 23 W
- Efficacy
- 2.2 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005123
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005123). Annual consumption calculated at 23 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Low consumption and permanent wiring
The Fantech FIT 120E-D-EC-HC brings three things together: electronically commutated motors, a motorized damper on the outdoor air and a power supply with no cord. It is the air exchanger to consider for a major renovation or a project where the code calls for a fixed connection, and where power consumption counts in the choice. Its certified net airflow is 129 cfm at 0.4 in.
The connections serving the home are on the right side, as on the standard version. For a unit with the reverse orientation, there is a left-hand version: the FIT 120E-D-EC-M-HC.
EC motors: the numbers
At the 51 cfm test airflow, this energy recovery ventilator (ERV) draws 23 W, or 2.2 cfm/W. The AC motor version, the FIT 120E-D-HC, draws 55 at the same airflow. At high speed, the gap is 74 W versus 104 W. Over a year, the spec sheet above estimates 201 kWh. The maximum current listed in Fantech's guide is 2.3 A.
The hard-wired connection
The electrician prepares a circuit; at installation, the wires enter the electrical box through a 3/8 in. cable clamp and connect to the unit's wires and grounding screw. The cover closes without pinching the wires, then the unit is powered up at the panel. A clearance of 2 3/8 in. above the electrical box is enough room to work.
The damper and the furnace connection
The -D damper comes standard with the EC motors. It closes when the unit is not ventilating, which prevents the furnace blower from pulling untreated outdoor air into the return plenum. Fantech recommends this type of unit for partially dedicated and simplified installations. The blower is interlocked with the unit's NO, C, NC relay, or left running continuously.
Winter and summer recovery
Sensible recovery efficiency is 77% at 0 °C and 51 cfm (80% adjusted). At −25 °C, it is 61% at the same airflow: the 54% threshold in section 9.32 of the Code for Greater Montreal is comfortably met. In summer, at 35 °C, total recovery reaches 70%. Defrost works by stopping the supply fan, with no drain.
Dimensions and installation
- 23.16 × 20.75 × 10.06 in., 35 lb; 25 in. wide with the damper.
- Four round 5 in. side connections.
- No drain.
- 8 1/2 in. of clearance in front of the door.
The ducts are fastened to the collars with a clamp, insulated, then covered with the vapour barrier and sealed with tape. On the hood side, the insulated flexible duct is kept taut and as short as possible.
Compatible controls
The low-voltage terminal block accepts a main control and auxiliary controls. Fantech's main controls with a VOC sensor, the ECO-Touch Auto IAQ and the ECO-Feel Auto IAQ, are wired with the correct polarity, and only one main control is allowed per unit. Bathroom timers and the MDEH1 dehumidistat can be added. The S+ and S- terminals are used for remote shutdown: when they are connected, the unit stays on standby until the contact opens.
Location
We install it in a mechanical room or in the basement, in a space that stays above 10 °C, near an exterior wall and away from the bedrooms.
Filters
Two washable electrostatic MERV 3 filters, 11 5/16 × 8 1/8 in. Options: MERV 8 (461674) and MERV 13 (461675).
Routine maintenance
The filters are inspected every three months and washed in warm soapy water. The core is checked every six months and rinsed with clean water. Once a year, Fantech recommends vacuuming the inside of the cabinet, cleaning the hoods and ducts, and having a qualified contractor do a general check-up.
Warranty
Seven years on the EC motors; five years on the core, the electrical components and the damper motor.
Installation by AirGreen
AirGreen installs and commissions this ERV in Montreal, Laval, Longueuil, the North Shore and the South Shore. We determine the required airflow with a room-by-room calculation under CSA F326, coordinate the circuit with the electrician, then balance the unit to the calculated airflow with the blower running.
The FIT 120E-D-EC-HC is listed in Section III of the HVI directory under no. 2005123, which makes its airflows and efficiencies verifiable by anyone. Since October 1, 2026, Rénoclimat no longer funds the installation of an HRV or an ERV; only files already open under the program's transition rules remain eligible.
Free quote: 514 316-2973 or sales@airgreen.ca.