Fantech ERV FIT 120E-D Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$53.68
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 120E-D has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 25 in, versus 24 5/8 in for the FIT 120E.
8.5 inCore comes out with 8 1/2 in of clearance
Core, filters, fans and electronic panel are reached through the door, held by two latches under the unit. Fantech calls for 8 1/2 in (216 mm) free in front of the door to remove the core, and 2 3/8 in above the electrical box for wiring.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005017Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−19 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm.
55 WMeasured at the airflow it actually runs at
Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005017) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 127 cfm
- SRE at 0 °C (51 cfm)
- 74%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 81%
- Power draw
- 55 W
- Efficacy
- 0.9 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005017
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005017). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The 120 size of the FIT series, ready for a furnace
The Fantech FIT 120E-D is the large size of the FIT series, fitted with a motorized damper on the outdoor air. Its certified net airflow reaches 127 cfm at 0.4 in. and 146 cfm at 0.2 in., while the FIT 80 tops out at 78 cfm. This energy recovery ventilator (ERV) is aimed at multi-bedroom units and townhouses whose needs go beyond an 80 size, while keeping a cabinet 10.06 in. thick.
The -D suffix makes it the unit to choose when the air exchanger will be connected to the return of a furnace or an air handler.
Why a damper on the outdoor air
Connected to the return plenum, an ERV that is switched off becomes an open passage: the blower keeps drawing and pulls untempered outdoor air right into the house. Fantech recommends a unit with a damper for partially dedicated and simplified installations. The FIT 120E-D has one built in at the factory. On a model without the -D, an accessory damper would have to be added, with its motor sold separately, and plugged into the auxiliary connector on the electrical box.
More airflow, same logic
Compared with the FIT 80, the connections go up to 5 in. and the cabinet grows a little: 23.16 × 20.75 × 10.06 in., at 35 lb. The airflow range runs from 40 to 127 cfm. Sensible recovery efficiency is 74% at 0 °C (51 cfm) and 81% as an adjusted value. At −25 °C, it stays at 61% at the same airflow, well above the 54% threshold in section 9.32 of the Code for Greater Montreal. In summer, total recovery is 64% at 35 °C, a clear step up from the 80 size.
Power consumption
The AC motors draw 55 W at the 51 cfm test airflow, or 0.9 cfm/W, and 104 W at high speed according to Fantech's selection guide. The annual estimate in the spec sheet above is about 482 kWh. If your electricity bill is the priority, the FIT 120E-D-EC, with EC motors, drops to 23 W at the same airflow.
Choosing between the 80 size and the 120 size
We don't pick the size by eye. The ventilation calculation gives an airflow for each room; if it exceeds what a FIT 80 delivers at the pressure of your duct system, the FIT 120E-D takes over. The 120 size also gains in efficiency, with 74% versus 70% at 0 °C. The trade-off is that it needs 5 in. ducts and a little more space at the ceiling.
Controls
The FIT 120E-D works with Fantech wall controls. The EDF8, for example, offers four speed settings: low, medium, high and 20 minutes per hour. Its AUTO button lets the occupant choose a humidity level; above it, the unit switches to high speed, then returns to its original mode. Without a wall control, the MIN, AUTO, MAX selector near the electrical box is enough to run the unit. Fantech points out that a control the occupant can reach improves comfort and can significantly reduce the unit's energy use.
Installation
- Side connection, four round 5 in. ports.
- Width with the damper: 25 in., versus 24 5/8 in. without the damper.
- No drain required.
- 8 1/2 in. of clearance in front of the door, 2 3/8 in. above the electrical box.
- Furnace blower running continuously, or interlocked through the NO, C and NC terminals.
- Not to be installed with a multi-zone system or with several forced-air systems.
Filters
The unit comes with two washable electrostatic MERV 3 filters, 11 5/16 × 8 1/8 in. For finer filtration, Fantech offers MERV 8 (461674) and MERV 13 (461675) filters.
Warranty
Fantech warranty: 7 years on the fan motors; 5 years on the core, the electrical components and the damper motor.
Installation by AirGreen in Greater Montreal
In Montreal, Laval, Longueuil, on the North Shore or on the South Shore, we first calculate the airflow each room requires under the CSA F326 standard. That calculation is what tells us whether a 120 size is needed or an 80 size is enough. We then connect the FIT 120E-D to the furnace return and balance both fans to the calculated airflow, with the blower running.
The FIT 120E-D is listed in Section III of the HVI directory under no. 2005017, which makes its airflows and efficiencies verifiable by anyone. On the financial assistance side, the rule changed on October 1, 2026: Rénoclimat no longer funds HRVs and ERVs, except for files already open under the program's transition rules.
For a free quote, call 514 316-2973 or write to sales@airgreen.ca.