Fantech ERV FIT 120E-D-EC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 129 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 129 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$22.45
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 23 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
ECMEC motors: 2.2 cfm/W instead of 0.9
The -EC suffix replaces the AC motors with electronically commutated motors. Fantech's selection guide lists 2.2 cfm/W fan efficacy at 0 °C, versus 0.9 for the FIT 120E-D, and a 40 to 129 cfm range at 0.4 in. Every -EC version also includes the -D motorized damper.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 120E-D-EC has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 25 in, versus 24 5/8 in for the FIT 120E.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2004961Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−17 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 129 cfm.
23 WMeasured at the airflow it actually runs at
Its 77% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 23 W, or about 201 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2004961) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 129 cfm
- SRE at 0 °C (51 cfm)
- 77%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 80%
- Power draw
- 23 W
- Efficacy
- 2.2 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2004961
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2004961). Annual consumption calculated at 23 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
EC motors: the most frugal version of the FIT series
The Fantech FIT 120E-D-EC replaces the AC motors of the FIT 120E with electronically commutated motors. At the 51 cfm test airflow, this energy recovery ventilator (ERV) draws 23 W, versus 55 W for the FIT 120E-D. Its fan efficiency goes from 0.9 to 2.2 cfm/W. Its certified net airflow is 129 cfm at 0.4 in.
All -EC versions also include the -D motorized damper: the unit is ready to be connected to a furnace return.
What EC motors change in practice
An air exchanger runs all year, often non-stop. The spec sheet above estimates the FIT 120E-D-EC's consumption at 201 kWh per year, versus 482 kWh for the AC motor version. At high speed, Fantech's guide gives 74 W, versus 104 W. The airflow range extends from 40 to 129 cfm.
Fantech adds a useful piece of advice. To keep electricity use to a minimum, the manufacturer recommends a fully dedicated installation. If the unit is instead connected to the furnace to distribute the air, a furnace with a variable-speed EC blower limits the consumption of the whole system. A wall control the occupant can reach can also reduce the unit's consumption.
Who it is for
An ERV runs almost all year; the more it runs, the more the gap between AC and EC motors shows on the bill. The FIT 120E-D-EC is therefore aimed at homes where ventilation runs continuously, owners looking for the lowest possible consumption, and projects where every watt counts in the energy balance.
Recovery
Sensible recovery efficiency reaches 77% at 0 °C (51 cfm), the best in the FIT series, and 80% as an adjusted value. At −25 °C, it is 61% at 51 cfm, above the 54% threshold in section 9.32 of the Code for Greater Montreal. In cooling mode, total recovery is 70% at 35 °C.
The motorized damper
Connected to the return plenum, an ERV that is stopped would let the furnace blower draw in untreated outdoor air. The FIT 120E-D-EC damper closes in that case. It brings the overall width to 25 in., versus 24 5/8 in. for the FIT 120E.
Installation
- 23.16 × 20.75 × 10.06 in., 35 lb.
- Side connection, four round 5 in. ports.
- No drain.
- 120 V power by cord.
- 8 1/2 in. in front of the door for maintenance.
For a quiet unit, Fantech calls for short ducts, few elbows, 45° elbows rather than 90° ones and Y fittings rather than T fittings. We apply these rules on every job.
Location
Fantech recommends a mechanical room, the furnace room or a basement, in a space that stays above 10 °C. The unit must remain accessible for maintenance and close to an exterior wall. It mounts on the ceiling or on the wall, with the included bracket.
Commissioning
Before the first start-up, we check that the ducts are insulated and connected, that no debris is left in the unit and that the air inlets and outlets are clear. At start-up, the exhaust fan runs alone for ten seconds. We then balance both fans with a Fantech touchscreen control and a manometer. An airflow set to the calculation avoids running the motors faster than necessary, and that is where EC motors deliver their full efficiency.
Filters
Two washable electrostatic MERV 3 filters, 11 5/16 × 8 1/8 in.; MERV 8 (461674) and MERV 13 (461675) options. Inspection every three months.
Warranty
EC motors: 7 years. Core, electrical components and damper motor: 5 years. The nameplate carries the serial number to provide for any replacement part, whether a motor, the control board or the core.
Installation by AirGreen in Greater Montreal
For a FIT 120E-D-EC, our work starts with a room-by-room ventilation calculation under the CSA F326 standard. We then choose between a dedicated installation and a furnace connection, taking into account Fantech's advice on consumption, then balance the unit to the calculated airflow. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.
In the HVI directory, the FIT 120E-D-EC is certified in Section III (no. 2004961): anyone can check its airflows and efficiencies there. Note that since October 1, 2026, installing an HRV or an ERV is no longer eligible for Rénoclimat assistance, except for files opened before that date under the transition rules.
Free quote: 514 316-2973 or sales@airgreen.ca.